Apollo precision frequency source and time standard
Apollo precision frequency source and time standard
Study of the accuracy of the double-precision arithmetic operations on the IBM 7094 computer
Accuracy of double-precision arithmetic operations on IBM 7094 computer
The Vacuum Optical Bench and Precision Measurement of Angles
Vacuum optical bench and precision measurement of angles
Observational Model for Precision Astrometry with the Space Interferometry Mission
The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain. Over a narrow field of view SIM is expected to achieve a mission accuracy of 1 microarcsecond. In this mode SIM will search for planetary companions to nearby stars by detecting the astrometric "wobble" relative to a nearby reference star. In its wide-angle mode, SIM will provide 4 microarcsecond precision absolute position measurements of stars, with parallaxes to comparable accuracy, at the end of its 5-year mission. The expected proper motion accuracy is around 3 microarcsecond/year, corresponding to a transverse velocity of 10 m/ s at a distance of 1 kpc. The basic astrometric observable of the SIM instrument is the pathlength delay. This measurement is made by a combination of internal metrology measurements that determine the distance the starlight travels through the two arms of the interferometer, and a measurement of the white light stellar fringe to find the point of equal pathlength. Because this operation requires a non-negligible integration time, the interferometer baseline vector is not stationary over this time period, as its absolute length and orientation are time varying. This paper addresses how the time varying baseline can be "regularized" so that it may act as a single baseline vector for multiple stars, as required for the solution of the astrometric equations.
Benefits of Model Updating: A Case Study Using the Micro-Precision Interferometer Testbed
This paper presents a case study on the benefits of model updating using the Micro-Precision Interferometer (MPI) testbed, a full-scale model of a future spaceborne optical interferometer located at JPL.
Precision Density Measurements Near the Helium Lambda Transition Using High-Q Microwave Cavities
A new experimental approach for high-precision density measurements of liquid helium near the lambda transition is proposed.
(abstract) Precision Time and Frequency Transfer Utilizing SONET OC-3
An innovative method of distributing precise time and reference frequency to users located several kilometers from a frequency standard and master clock has been developed by the Timing Solutions Corporation of Boulder, CO. The Optical Two-Way Time Transfer System (OTWTTS) utilizes a commercial SONET OC-3 facility interface to physically connect a master unit to multiple slave units at remote locations. Optical fiber is a viable alternative to standard copper cable and microwave transmission. This paper discusses measurements of frequency and timing stability over the OTWTTS.
Micro-Precision Interferometer: Pointing Control System
This paper describes the development of the wavefront tilt (pointing) control system for the JPL Micro-Precision Interferometer (MPI). This control system employs piezo-electric actuators and a digital imaging sensor with feedback compensation to reject errors in instrument pointing. Stringent performance goals require large feedback, however, several characteristics of the plant tend to restrict the available bandwidth. A robust 7th-order wavefront tilt control system was successfully implemented on the MPI instrument, providing sufficient disturbance rejection performance to satisfy the established interference fringe visibility.
Dynamics of Large Precision Space Structures for Structural Control
This paper presents an overview of the challenges encountered in the prediction and ground test verification of structural dynamics for on-orbit control of large precision space structures.
Structural and Optical Pathlength Control Experiments on a Precision Truss
An experimental implementation of a nanometer level optical pathlength controller for long baseline space interferometry is presented. The pathlength compensation system is tested on a large precision truss structure and thus structural dynamics play a dominant role in the control system design.
A network architecture for precision formation flying using the IEEE 802.11 MAC Protocol
Precision Formation Flying missions involve the tracking and maintenance of spacecraft in a desired geometric formation. The strong coupling of spacecraft in formation flying control requires inter-spacecraft communication to exchange information. In this paper, we present a network architecture that supports PFF control, from the initial random deployment phase to the final formation. We show that a suitable MAC layer for the application protocol is IEEE's 802.11 MAC protocol. IEEE 802.11 MAC has two modes of operations: DCF and PCF. We show that DCF is suitable for the initial deployment phase while switching to PCF when the spacecraft are in formation improves jitter and throughput. We also consider the effect of routing on protocol performance and suggest when it is profitable to turn off route discovery to achieve better network performance.
A Precision Deployable Aperture System Facility
This paper describes an overview of the precision environment test enclosure for testing the structures, a metrology system for absolute measurement at the micron level and the formulation of a modeling methodology that integrates the measurement of aperture components or subsystems w1th models for direct validation.
Field Demonstrations of Active Laser Ranging with Sub-mm Precision
Precision ranging between planets will provide valuable information for scientific studies of the solar system and fundamental physics. Current passive ranging techniques using retro-reflectors are limited to the Earth-Moon distance due to the 1/R? losses. We report on a laboratory realization and field implementation of active laser ranging in real-time with two terminals, emulating interplanetary distance. Sub-millimeter accuracy is demonstrated.
High Precision Thermal, Structural and Optical Analysis of an External Occulter Using a Common Model and the General Purpose Multi-Physics Analysis Tool Cielo
The efficient simulation of multidisciplinary thermo-opto-mechanical effects in precision deployable systems has for years been limited by numerical toolsets that do not necessarily share the same finite element basis, level of mesh discretization, data formats, or compute platforms. Cielo, a general purpose integrated modeling tool funded by the Jet Propulsion Laboratory and the Exoplanet Exploration Program, addresses shortcomings in the current state of the art via features that enable the use of a single, common model for thermal, structural and optical aberration analysis, producing results of greater accuracy, without the need for results interpolation or mapping. This paper will highlight some of these advances, and will demonstrate them within the context of detailed external occulter analyses, focusing on in-plane deformations of the petal edges for both steady-state and transient conditions, with subsequent optical performance metrics including intensity distributions at the pupil and image plane.
SmallSat Precision Navigation with Low-Cost MEMS IMU Swarms
The continued advancement of small satellite-based science missions requires the solution to a number of important technical challenges. Of particular note is that small satellite missions are characterized by tight constraints on cost, mass, power, and volume that make them unable to fly the high-quality Inertial Measurement Units (IMUs) required for orbital missions demanding precise orientation and positioning. Instead, small satellite missions typically fly low-cost Micro-Electro-Mechanical System (MEMS) IMUs. Unfortunately, the performance characteristics of these MEMS IMUs make them ineffectual in many spaceflight applications when employed in a single IMU system configuration.
Precision Epoch of Reionization Studies with Next-Generation CMB Experiments
Future arcminute resolution polarization data from ground-based Cosmic Microwave Background (CMB) observations can be used to estimate the contribution to the temperature power spectrum from the primary anisotropies and to uncover the signature of reionization near l = 1500 in the small angular-scale temperature measurements. Our projections are based on combining expected small-scale E-mode polarization measurements from Advanced ACTPol in the range 300 < l < 3000 with simulated temperature data from the full Planck mission in the low and intermediate l region, 2 < l < 2000. We show that the six basic cosmological parameters determined from this combination of data will predict the underlying primordial temperature spectrum at high multipoles to better than 1% accuracy. Assuming an efficient cleaning from multi-frequency channels of most foregrounds in the temperature data, we investigate the sensitivity to the only residual secondary component, the kinematic Sunyaev-Zel'dovich (kSZ) term. The CMB polarization is used to break degeneracies between primordial and secondary terms present in temperature and, in effect, to remove from the temperature data all but the residual kSZ term. We estimate a 15 sigma detection of the di use homogeneous kSZ signal from expected AdvACT temperature data at l > 1500, leading to a measurement of the amplitude of matter density fluctuations, sigma 8, at 1% precision.
Degradation of Precision Reference Devices in Space Environments
This paper presents radiation test results for several different precision voltage devices. Their degradation is compared to that expected for the basic bandgap reference circuit, which is used as a theoretical benchmark, and uses only npn transistorss.