Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Spatially Resolved Imaging at 350 Micrometers of Cold Dust in Nearby Elliptical Galaxies

Continuum observations at 350 micrometers of seven nearby elliptical galaxies for which CO gas disks have recently been resolved with interferometry mapping are presented. These SHARC II mapping results provide the first clearly resolved far-infrared (FIR)-to-submillimeter continuum emission from cold dust (with temperatures 31 K is approximately greater than T approximately greater than 23 K) of any elliptical galaxy at a distance greater than 40 Mpc. The measured FIR excess shows that the most likely and dominant heating source of this dust is not dilute stellar radiation or cooling flows, but rather star formation that could have been triggered by an accretion or merger event and fueled by dust-rich material that has settled in a dense region cospatial with the central CO gas disks. The dust is detected even in two cluster ellipticals that are deficient in H (sub I), showing that, unlike H (sub I), cold dust and CO in ellipticals can survive in the presence of hot X-ray gas, even in galaxy clusters. No dust cooler than 20 K, either distributed outside the CO disks or cospatial with and heated by the entire dilute stellar optical galaxy (or very extended H (sub I)), is currently evident.

photometry↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures

Alignment of two-element telescopes is a classic problem. During recent integration and test of the Space Interferometry Mission s (SIM s) Astrometric Beam Combiner (ABC), the innovators were faced with aligning two such telescope subsystems in the presence of a further complication: only two small subapertures in each telescope s pupil were accessible for measuring the wavefront with a Fizeau interferometer. This meant that the familiar aberrations that might be interpreted to infer system misalignments could be viewed only over small sub-regions of the pupil, making them hard to recognize. Further, there was no contiguous surface of the pupil connecting these two subapertures, so relative phase piston information was lost; the underlying full-aperture aberrations therefore had an additional degree of ambiguity. The solution presented here is to recognize that, in the absence of phase piston, the Zygo measurements primarily provide phase tilt in the subaperture windows of interest. Because these windows are small and situated far from the center of the (inaccessible) unobscured full aperture, any aberrations that are higher-order than tilt will be extremely high-order on the full aperture, and so not necessary or helpful to the alignment. Knowledge of the telescope s optical prescription allows straightforward evaluation of sensitivities (subap mode strength per unit full-aperture aberration), and these can be used in a predictive matrix approach to move with assurance to an aligned state. The technique is novel in every operational way compared to the standard approach of alignment based on full-aperture aberrations or searching for best rms wavefront. This approach is closely grounded in the observable quantities most appropriate to the problem. It is also more intuitive than inverting full phase maps (or subaperture Zernike spectra) with a ray-tracing program, which must certainly work in principle, but in practice met with limited success. Even if such classical alignment techniques became practical, the techniques reported here form a reassuringly transparent and intuitive check on the course of the alignment with very little computational effort.

Bloemhof, Eric E.↗

Quantum Correlated Multi-Fragment Reaction Imaging

This grant supported research in basic atomic, molecular and optical physics related to the interactions of atoms with particles and fields. This report will focus on the 12 year period from 2004 to 2017, although the DOE–BES has supported my research every year since 1986. All of the support from the grant was used to pay summer salaries of the PI and students and travel to conferences and meetings. The results were in the form of publications in peer reviewed journals as well as conference invited talks and colloquiums. There were 12 peer reviewed publications in these 12+ years. Innovations in few-body science at molecular and nano levels are a critical component of on- going efforts to establish sustainable environmental and energy resources. The varied research paths taken will require the development of basic science on broad fronts with increasing flexi- bility to crossover technologies. We thus worked to extract understanding and quantum control of few-body microscopic systems based on our long-time experience with more conventional studies of correlated electrons and ions. Given the enormous advances over the past 20 years to our understanding of quantum cor- relations with photon interferometry, AMO collision science generally is ready to move beyond the one-particle, single-port momentum detection that has dominated collision physics since Rutherford. Nevertheless, our familiar theoretical tools for collision theory need to be up- graded to incorporate these more generalized measurement formalisms and ultimately to give incentive for a new generation of experiments. Our interest in these topics remains motivated by the recent surge in and success of exper- iments involving few-body atomic and molecular fragmentation and the detection of all the fragments. The research described here thus involved two parallel efforts with (i) emphasis on reaction imaging while (ii) pursuing longtime work on quantum correlated collective excitations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low Temperature Growth of Nanostructured Diamond Films on Metals

The field of nanocrystalline diamond and tetrahedral amorphous carbon films has been the focus of intense experimental activity in the last few years for applications in field emission display devices, optical windows, and tribological coatings, The choice of substrate used in most studies has typically been silicon. For metals, however, the thermal expansion mismatch between the diamond film and substrate gives rise to thermal stress that often results in delamination of the film. To avoid this problem in conventional CVD deposition low substrate temperatures (less than 700 C) have been used, often with the incorporation of oxygen or carbon monoxide to the feedgas mixture. Conventionally grown CVD diamond films are also rough and would require post-deposition polishing for most applications. Therefore, there is an obvious need to develop techniques for deposition of well-adhered, smooth nano-structured diamond films on metals for various tribological applications. In our work, nanostructured diamond films are grown on a titanium alloy substrate using a two-step deposition process. The first step is performed at elevated temperature (820 C) for 30 minutes using a H2/CH4/N2 gas mixture in order to grow a thin (approx. 600 nm) nanostructured diamond layer and improve film adhesion. The remainder of the deposition involves growth at low temperature (less than 600 C) in a H2/CH4/O2 gas mixture. Laser reflectance Interferometry (LRI) pattern during growth of a nanostructured diamond film on Ti-6Al-4V alloy. The first 30 minutes are at a high temperature of 820 C and the rest of the film is grown at a low temperature of 580 T. The fringe pattern is observed till the very end due to extremely low surface roughness of 40 nm. The continuation of the smooth nanostructured diamond film growth during low temperature deposition is confirmed by in-situ laser reflectance interferometry and by post-deposition micro-Raman spectroscopy and surface profilometry. Similar experiments performed without the starting nanostructured diamond layer resulted in poorly adhered films with a more crystalline appearance and a higher surface roughness. This low temperature deposition of nanostructured diamond films on metals offers advantages in cases where high residual thermal stress leads to delamination at high temperatures.

Baker, Paul A.↗

Interferometric constraints on quantum geometrical shear noise correlations

Final measurements and analysis are reported from the first-generation Holometer, the first instrument capable of measuring correlated variations in space-time position at strain noise power spectral densities smaller than a Planck time. The apparatus consists of two co-located, but independent and isolated, 40 m power-recycled Michelson interferometers, whose outputs are cross-correlated to 25 MHz. The data are sensitive to correlations of differential position across the apparatus over a broad band of frequencies up to and exceeding the inverse light crossing time, 7.6 MHz. By measuring with Planck precision the correlation of position variations at spacelike separations, the Holometer searches for faint, irreducible correlated position noise backgrounds predicted by some models of quantum space-time geometry. The first-generation optical layout is sensitive to quantum geometrical noise correlations with shear symmetry---those that can be interpreted as a fundamental noncommutativity of space-time position in orthogonal directions. General experimental constraints are placed on parameters of a set of models of spatial shear noise correlations, with a sensitivity that exceeds the Planck-scale holographic information bound on position states by a large factor. Furthermore, this result significantly extends the upper limits placed on models of directional noncommutativity by currently operating gravitational wave observatories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Event Horizon Telescope imaging of the archetypal blazar 3C 279 at an extreme 20 microarcsecond resolution

3C 279 is an archetypal blazar with a prominent radio jet that show broadband flux density variability across the entire electromagnetic spectrum. We use an ultra-high angular resolution technique – global Very Long Baseline Interferometry (VLBI) at 1.3 mm (230 GHz) – to resolve the innermost jet of 3C 279 in order to study its fine-scale morphology close to the jet base where highly variable γ-ray emission is thought to originate, according to various models. The source was observed during four days in April 2017 with the Event Horizon Telescope at 230 GHz, including the phased Atacama Large Millimeter/submillimeter Array (ALMA), at an angular resolution of ∼20 μas (at a redshift of z = 0.536 this corresponds to ∼0.13 pc ∼ 1700 Schwarzschild radii with a black hole mass MBH = 8 × 108 M⊙). Imaging and model-fitting techniques were applied to the data to parameterize the fine-scale source structure and its variation. We find a multicomponent inner jet morphology with the northernmost component elongated perpendicular to the direction of the jet, as imaged at longer wavelengths. The elongated nuclear structure is consistent on all four observing days and across different imaging methods and model-fitting techniques, and therefore appears robust. Owing to its compactness and brightness, we associate the northern nuclear structure as the VLBI “core”. This morphology can be interpreted as either a broad resolved jet base or a spatially bent jet. We also find significant day-to-day variations in the closure phases, which appear most pronounced on the triangles with the longest baselines. Our analysis shows that this variation is related to a systematic change of the source structure. Two inner jet components move non-radially at apparent speeds of ∼15 c and ∼20 c (∼1.3 and ∼1.7 μas day−1, respectively), which more strongly supports the scenario of traveling shocks or instabilities in a bent, possibly rotating jet. The observed apparent speeds are also coincident with the 3C 279 large-scale jet kinematics observed at longer (cm) wavelengths, suggesting no significant jet acceleration between the 1.3 mm core and the outer jet. The intrinsic brightness temperature of the jet components are ≲1010 K, a magnitude or more lower than typical values seen at ≥7 mm wavelengths. The low brightness temperature and morphological complexity suggest that the core region of 3C 279 becomes optically thin at short (mm) wavelengths.Key words: galaxies: active / galaxies: jets / galaxies: individual: 3C 279 / techniques: interferometric⋆ The data are only available at the CDS via anonymous ftp to cdsarc.u-strasbg.fr (130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/cat/J/A+A/640/A69 and at https://eventhorizontelescope.org/for-astronomers/data⋆⋆ Deceased.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for Planets with the Space Interferometry Mission

The Space Interferometry Mission (SIM) will be the first space-based long baseline Michelson interferometer designed for precision astrometry. It will address a wide range of problems in stellar astrophysics and Galactic structure, delivering precision astrometry of stars down to 20 magnitude throughout the entire Galaxy. SIM uses a 10-m Michelson interferometer in Earth-trailing solar orbit to provide 4 microarcsecond (gas) precision astrometry. With a 5-year mission lifetime, SIM will be a powerful tool for discovering planets around nearby stars, through detection of the stellar reflex motion. The astrometric method complements the radial velocity technique which as already yielded many new planets, with an important benefit of directly measuring planetary masses. SIM will have a single-measurement precision of 1 microarcsecond in a frame defined by nearby reference stars, enabling searches for planets with masses as small as a few earth masses around the nearest stars. More massive planets will be detectable to much larger distances. In addition to precision astrometry SIM will also serve an important role as a technology precursor for future astrophysics missions using interferometers. Two technologies demonstrated will be high dynamic-range aperture synthesis imaging at 10-milliarcsec resolution in the optical, and fringe nulling to 10 (exp -4).

Unwin, Stephen↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

Study of the prebreakdown stage of a gas discharge in a diode with point cathode by laser probing

The prebreakdown stage of a gas discharge in a diode with strongly overloaded cathode is studied by laser methods (by simultaneous use of multiframe interferometry and shadow and schlieren photographing) at atmospheric pressure. The spatial resolution of the methods is about 20 μm. A probing pulse of a laser (LS-2151 Nd: YAG laser with a half amplitude duration of 70 ps and a pulse energy of up to 40 mJ) is synchronized with a voltage pulse with accuracy of about 1 ns. High field strength at the cathode is achieved due to the use of thin individual metal tips on the electrodes. It is shown that the initial stage of breakdown of a discharge gap is accompanied by the emergence of a dense plasma cloud at the end of a tip with electron density of about 5 × 10{sup 19} cm{sup –3} with a size of tens of microns, as well as by a sharp increase in the total current through the diode. After the emergence of a dense plasma cloud at the end of a cathode tip, a similar cloud is formed on the surface of the anode; sometime later, these clouds join together and form a tubular current channel. The dynamics of the breakdown, as well as the parameters of the plasma are studied by the abovementioned techniques in three independent optical channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for monopole-dipole interactions with atom interferometry

Light, weakly coupled bosonic particles such as axions can mediate long range monopole-dipole interactions between matter and spins. We propose a new experimental method to detect such a force exerted by the spin of electrons on a freely falling atom using atom interferometry. The intrinsic advantages of atom interferometry, such as the freely falling nature of the atom and the well-defined response of the atom to external magnetic fields, should enable the proposed method to overcome systematic effects induced by vibrations, magnetic fields, and gravity. This approach is most suited to probe forces with a range ≳ 10 cm. With current technology, our proposed setup could potentially extend probes of such forces by an order of magnitude beyond present laboratory limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mitigation of Angle Tracking Errors Due to Color Dependent Centroid Shifts in SIM-Lite

The SIM-Lite astrometric interferometer will search for Earth-size planets in the habitable zones of nearby stars. In this search the interferometer will monitor the astrometric position of candidate stars relative to nearby reference stars over the course of a 5 year mission. The elemental measurement is the angle between a target star and a reference star. This is a two-step process, in which the interferometer will each time need to use its controllable optics to align the starlight in the two arms with each other and with the metrology beams. The sensor for this alignment is an angle tracking CCD camera. Various constraints in the design of the camera subject it to systematic alignment errors when observing a star of one spectrum compared with a start of a different spectrum. This effect is called a Color Dependent Centroid Shift (CDCS) and has been studied extensively with SIM-Lite's SCDU testbed. Here we describe results from the simulation and testing of this error in the SCDU testbed, as well as effective ways that it can be reduced to acceptable levels.

Spectral↗

Sensor Noise in LISA Pathfinder: In-Flight Performance of the Optical Test Mass Readout

We report on the first subpicometer interferometer flown in space. It was part of ESA’s Laser Interferometer Space Antenna (LISA) Pathfinder mission and performed the fundamental measurement of the positional and angular motion of two free-falling test masses. The interferometer worked immediately, stably, and reliably from switch on until the end of the mission with exceptionally low residual noise of 32.0 (+2.4, −1.7) fm/(√Hz), significantly better than required. We present an upper limit for the sensor performance at millihertz frequencies and a model for the measured sensitivity above 200 mHz.

Gravitational Waves,↗

Overview of SIM wide angle astrometric system calibration strategies

This paper summarizes two very different strategies envisioned for calibrating the systematic field dependent biases present in the Space Interferometry Mission (SIM) instrument. The Internal Calibration strategy is based on pre-launch measurements combined with a set of on orbit measurements generated by a source internal to the instrument. The External Calibration strategy uses stars as an external source for generating the calibration function. Both approaches demand a significant amount of innovation given that SIM's calibration strategy requires a post-calibration error of 100picometers over a 15 degree field of regard while the uncalibrated instrument introduces 10's-100's of nanometers of error. The calibration strategies are discussed in the context of the Wide Angle Astrometric mode of the instrument, although variations on the Internal Calibration Strategy may be used for doing Narrow Angle Astrometry.

calibration SIM optical modeling↗

Transitional Disks Associated with Intermediate-Mass Stars: Results of the SEEDS YSO Survey

Protoplanetary disks are where planets form, grow, and migrate to produce the diversity of exoplanet systems we observe in mature systems. Disks where this process has advanced to the stage of gap opening, and in some cases central cavity formation, have been termed pre-transitional and transitional disks in the hope that they represent intermediate steps toward planetary system formation. Recent reviews have focussed on disks where the star is of solar or sub-solar mass. In contrast to the sub-millimeter where cleared central cavities predominate, at H-band some T Tauri star transitional disks resemble primordial disks in having no indication of clearing, some show a break in the radial surface brightness profile at the inner edge of the outer disk, while others have partially to fully cleared gaps or central cavities. Recently, the Meeus Group I Herbig stars, intermediate-mass PMS stars with IR spectral energy distributions often interpreted as flared disks, have been proposed to have transitional and pre-transitional disks similar to those associated with solar-mass PMS stars, based on thermal-IR imaging, and sub-millimeter interferometry. We have investigated their appearance in scattered light as part of the Strategic Exploration of Exoplanets and Disks with Subaru (SEEDS), obtaining H-band polarimetric imagery of 10 intermediate-mass stars with Meeus Group I disks. Augmented by other disks with imagery in the literature, the sample is now sufficiently large to explore how these disks are similar to and differ from T Tauri star disks. The disk morphologies seen in the Tauri disks are also found for the intermediate-mass star disks, but additional phenomena are found; a hallmark of these disks is remarkable individuality and diversity which does not simply correlate with disk mass or stellar properties, including age, including spiral arms in remnant envelopes, arms in the disk, asymmetrically and potentially variably shadowed outer disks, gaps, and one disk where only half of the disk is seen in scattered light at H. We will discuss our survey results in terms of spiral arm theory, dust trapping vortices, and systematic differences in the relative scale height of these disks compared to those around Solar-mass stars. For the disks with spiral arms we discuss the planet-hosting potential, and limits on where giant planets can be located. We also discuss the implications for imaging with extreme adaptive optics instruments. Grady is supported under NSF AST 1008440 and through the NASA Origins of Solar Systems program on NNG13PB64P. JPW is supported NSF AST 100314. 0) in marked contrast to protoplanetary disks, transitional disks exhibit wide range of structural features1) arm visibility correlated with relative scale height in disk2) asymmetric and possibly variable shadowing of outer portions some transitional disks3) confirm pre-transitional disk nature of Oph IRS 48, MWC 758, HD 169142, etc.

Protoplanetary disks↗

SIM Lite: Ground Alignment of the Instrument

We present the start of the ground alignment plan for the SIM Lite Instrument. We outline the integration and alignment of the individual benches on which all the optics are mounted, and then the alignment of the benches to form the Science and Guide interferometers. The Instrument has a guide interferometer with only a 40 arc-seconds field of regard, and 200 arc-seconds of alignment adjustability. This requires each sides of the interferometer to be aligned to a fraction of that, while at the same time be orthogonal to the baseline defined by the External Metrology Truss. The baselines of the Science and Guide interferometers must also be aligned to be parallel. The start of these alignment plans is captured in a SysML Instrument System model, in the form of activity diagrams. These activity diagrams are then related to the hardware design and requirements. We finish with future plans for the alignment and integration activities and requirements.

Alignment plan↗

NEAT: A Microarcsec Astrometric Telescope

NEAT, Nearby Exo-Earth Astrometric Telescope is a medium-small telescope ~ 1m in diameter that is designed to make ultra precise < 1 uas (microarcsec) astrometric measurements of nearby stars in a ~ 1hr observation. Four major error sources prevent normal space telescopes from obtaining accuracies close to 1 uas. Even with a small 1m telescope, photon noise is usually not a problem for the bright nearby target stars. But in general, the reference stars are much fainter. Typically a field of view of ~0.5 deg dia is needed to obtain enough bright reference stars. The NEAT concept uses a very simple but unusual design to avoid optically induced astrometric errors. The third source of error is the accuracy and stability of the focal plane. A 1uas error over a ~2000 arcsec field of view implies the focal plane is accurate or at least stable to 5 parts in 1010 over the lifetime of the mission (~5yrs). The 4th class of error has to do with our knowledge of the PSF and how that PSF is sampled by an imperfect detector. A Nyquist sampled focal plane would have > 2 pixels per ?/D, and centroiding to 1uas means centroiding to 10-5 pixels. This paper describes the mission concept, and an overview of the technology needed to perform 1uas astrometry with a small telescope, and how we overcome problems 1 and 2. A companion paper will describe the technical progress we've made in solving problems 3 and 4.

interferometry↗

Absolute calibration of Doppler coherence imaging velocity images

Here, a new technique has been developed for absolutely calibrating a Doppler Coherence Imaging Spectroscopy interferometer for measuring plasma ion and neutral velocities. An optical model of the interferometer is used to generate zero-velocity reference images for the plasma spectral line of interest from a calibration source some spectral distance away. Validation of this technique using a tunable diode laser demonstrated an accuracy better than 0.2 km/s over an extrapolation range of 3.5 nm; a two order of magnitude improvement over linear approaches. While a well-characterized and very stable interferometer is required, this technique opens up the possibility of calibrated velocity measurements in difficult viewing geometries and for complex spectral line-shapes.

spectroscopy and imaging↗