Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical detectability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

Future Lightning Instruments for Weather and Climate Monitoring From LEO

Lightning is not only a natural hazard, but it also holds information about physical processes at work in deep convection and influences atmospheric oxidants that modulate ozone and methane. Hence, spaceborne lightning observations are essential for monitoring extreme events and feedbacks in Earth’s climate system. Low-Earth orbiting (LEO) lightning mapping instruments established a 25-year record of global lightning activity and resulted in a wealth of studies that motivated its designation as an Essential Climate Variable by the World Meteorological Organization. Although geostationary observations of lightning have become increasingly available since 2017, LEO lightning mappers continue to serve critical needs given their unique vantage point and acceptance as a unifying reference for geostationary lightning mapper and ground-based global lightning datasets. At the close of 2023, the Lightning Imaging Sensor (LIS) will cease operations on the International Space Station, which introduces a critical gap in LEO-based monitoring of global lightning activity. To address this need, NASA is developing new lightning mapping technology that enables future LEO-based satellite missions. Existing LEO-based lightning mappers rely on narrowband optical emissions centered on 777.4-nm and detectors that capture 500 images per second to detect lightning both day and night. Lightning can also produce optical emissions in a narrowband centered on 337-nm without any corresponding emissions at the traditionally used near-infrared (NIR) wavelength. These near-ultraviolet (UV) emissions are associated with earlier stage electrical breakdown (e.g., streamers), may frequent intense regions of deep convective storms, and may be a significant source of nitrogen oxide production in the upper atmosphere. A new lightning mapping instrument called the CubeSat Lightning Imaging and Detection Experiment (CLIDE) is being designed at NASA Marshall Space Flight Center to use high-speed, scientific CMOS image sensors capable of detecting lightning’s transient optical emissions in the near-UV and NIR during both daylit and nighttime scenes. This will extend the record of global lightning activity and help pave the way for future small satellite missions that combine radio and optical lightning detectors to obtain novel three-dimensional maps of lightning on a global scale, which can revolutionize the way lightning is used to monitor weather and understand changes in climate.

lightning↗

Optical and X-Ray Early Follow-Up of ANTARES Neutrino Alerts

High-energy neutrinos could be produced in the interaction of charged cosmic rays with matter or radiation surrounding astrophysical sources. Even with the recent detection of extraterrestrial high-energy neutrinos by the IceCube experiment, no astrophysical neutrinosource has yet been discovered. Transient sources, such as gamma-ray bursts, core-collapse supernovae, or active galactic nuclei are promising candidates. Multi-messenger programs offer a unique opportunity to detect these transient sources. By combining the information provided by the ANTARES neutrino telescope with information coming from other observatories, the probability of detecting a source is enhanced, allowing the possibility of identifyinga neutrino progenitor from a single detected event. A method based on optical and X-ray follow-ups of high-energy neutrino alerts has been developed within the ANTARES collaboration. This method does not require any assumptions on the relation between neutrino and photon spectra other than time-correlation. This program, denoted as TAToO, triggers a network of robotic optical telescopes (TAROTand ROTSE) and the Swift-XRT with a delay of only a few seconds after a neutrino detection, and is therefore well-suited to search for fast transient sources. To identify an optical or Xraycounterpart to a neutrino signal, the images provided by the follow-up observations areanalysed with dedicated pipelines. A total of 42 alerts with optical and 7 alerts with X-ray images taken with a maximum delay of 24 hours after the neutrino trigger have been analyzed. No optical or X-ray counterparts associated to the neutrino triggers have been found, and upper limits on transient source magnitudes have been derived. The probability to reject the gamma-ray burst origin hypothesis has been computed for each alert.

X-ray telescopes↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

Optical zero-differential pressure switch and its evaluation in a multiple pressure measuring system

The design of a clamped-diaphragm pressure switch is described in which diaphragm motion is detected by a simple fiber-optic displacement sensor. The switch was evaluated in a pressure measurement system where it detected the zero crossing of the differential pressure between a static test pressure and a tank pressure that was periodically ramped from near zero to fullscale gage pressure. With a ramping frequency of 1 hertz and a full-scale tank pressure of 69 N/sq cm gage (100 psig), the switch delay was as long as 2 milliseconds. Pressure measurement accuracies were 0.25 to 0.75 percent of full scale. Factors affecting switch performance are also discussed.

Powell, J. A.↗

Holographic Airborne Rotating Lidar Instrument Experiment (HARLIE)

Scanning holographic lidar receivers are currently in use in two operational lidar systems, PHASERS (Prototype Holographic Atmospheric Scanner for Environmental Remote Sensing) and now HARLIE (Holographic Airborne Rotating Lidar Instrument Experiment). These systems are based on volume phase holograms made in dichromated gelatin (DCG) sandwiched between 2 layers of high quality float glass. They have demonstrated the practical application of this technology to compact scanning lidar systems at 532 and 1064 nm wavelengths, the ability to withstand moderately high laser power and energy loading, sufficient optical quality for most direct detection systems, overall efficiencies rivaling conventional receivers, and the stability to last several years under typical lidar system environments. Their size and weight are approximately half of similar performing scanning systems using reflective optics. The cost of holographic systems will eventually be lower than the reflective optical systems depending on their degree of commercialization. There are a number of applications that require or can greatly benefit from a scanning capability. Several of these are airborne systems, which either use focal plane scanning, as in the Laser Vegetation Imaging System or use primary aperture scanning, as in the Airborne Oceanographic Lidar or the Large Aperture Scanning Airborne Lidar. The latter class requires a large clear aperture opening or window in the aircraft. This type of system can greatly benefit from the use of scanning transmission holograms of the HARLIE type because the clear aperture required is only about 25% larger than the collecting aperture as opposed to 200-300% larger for scan angles of 45 degrees off nadir.

Schwemmer, Geary K.↗

Polarization Angle Swings in Blazars Detected in the Millimeter-wave with the South Pole Telescope

We present the first systematic search for electric vector position angle (EVPA) swings in the millimeter-wave (mm-wave) emission of blazars, using five years of observations from the South Pole Telescope SPT-3G camera at 95 and 150 GHz, and investigate their connection to gamma-ray flares. Of the 168 bright sources in the ~1500 square degrees SPT-3G Main Field, eight have sufficient polarization signal-to-noise for reliable EVPA measurement, four of which have continuous Fermi LAT gamma-ray detections. We detect EVPA swings in all four gamma-ray-active blazars and in none of the remaining four, consistent with the established connection between EVPA swings and high-energy emission seen at optical wavelengths. The observed swing amplitudes and rotation rates are smaller than those found in optical studies, consistent with mm-wave EVPA variability being slower than at shorter wavelengths. Random walk simulations of the polarization angle using a multi-cell model fail to reproduce both the number, amplitude, and duration of the observed swings, suggesting that this mechanism is insufficient to explain the observed swing population. Analysis of EVPA variability on one-week timescales is consistent with the anti-correlation between polarization degree and EVPA rotation rate previously observed at optical wavelengths. Of the 14 detected swings, eight are within 30 days of a gamma-ray flare. While many individual swing-flare associations are found to have a very low probability of happening by chance, the full ensembles of 95 and 150 GHz swing time lags with respect to gamma-ray flares are found to be consistent with random coincidence.

Simpson, A. [Chicago U., Astron. Astrophys. Ctr.; ↗

A Wide and Deep Exploration of Radio Galaxies with Subaru HSC (WERGS). III. Discovery of a z = 4.72 Radio Galaxy with the Lyman Break Technique

We report a discovery of a z = 4.72 radio galaxy, HSC J083913.17+011308.1, using the Lyman break technique with the Hyper Suprime-Cam Subaru Strategic Survey (HSC-SSP) catalog for Very Large Array Faint Images of the Radio Sky at Twenty centimeter radio sources. The number of known high-z radio galaxies (HzRGs) at z > 3 is quite small to constrain the evolution of HzRGs so far. The deep and wide-area optical survey by HSC-SSP enables us to apply the Lyman break technique to a large search for HzRGs. For an HzRG candidate among pre-selected r-band dropouts with a radio detection, a follow-up optical spectroscopy with the Gemini Multi-Object Spectrographs (GMOS)/Gemini has been performed. The obtained spectrum presents a clear Lyα emission line redshifted to z = 4.72. The spectral energy distribution fitting analysis with the rest-frame UV and optical photometries suggests the massive nature of this HzRG with logM{sub ∗}/M{sub ⊙}=11.4. The small equivalent width of Lyα and the moderately red UV colors indicate its dusty host galaxy, implying a chemically evolved and dusty system. The radio spectral index does not meet a criterion for an ultra-steep spectrum, α{sub 1400}{sup 325} of −1.1 and α{sub 1400}{sup 150} of −0.9, demonstrating that the HSC-SSP survey compensates for a subpopulation of HzRGs that are missed in surveys focusing on an ultra-steep spectral index.

79 ASTRONOMY AND ASTROPHYSICS↗

THOR: Cloud Thickness from Off beam Lidar Returns

Conventional wisdom is that lidar pulses do not significantly penetrate clouds having optical thickness exceeding about tau = 2, and that no returns are detectable from more than a shallow skin depth. Yet optically thicker clouds of tau much greater than 2 reflect a larger fraction of visible photons, and account for much of Earth s global average albedo. As cloud layer thickness grows, an increasing fraction of reflected photons are scattered multiple times within the cloud, and return from a diffuse concentric halo that grows around the incident pulse, increasing in horizontal area with layer physical thickness. The reflected halo is largely undetected by narrow field-of-view (FoV) receivers commonly used in lidar applications. THOR - Thickness from Off-beam Returns - is an airborne wide-angle detection system with multiple FoVs, capable of observing the diffuse halo, detecting wide-angle signal from which physical thickness of optically thick clouds can be retrieved. In this paper we describe the THOR system, demonstrate that the halo signal is stronger for thicker clouds, and validate physical thickness retrievals for clouds having z > 20, from NASA P-3B flights over the Department of Energy/Atmospheric Radiation Measurement/Southern Great Plains site, using the lidar, radar and other ancillary ground-based data.

Cahalan, Robert F.↗

R.F Microphotonics for NASA Space Communications Applications

An RF microphotonic receiver has-been developed at Ka-band. The receiver consists of a lithium niobate micro-disk that enables RF-optical coupling to occur. The modulated optical signal (- 200 THz) is detected by the high-speed photonic signal processing electronics. When compared with an electronic approach, the microphotonic receiver technology offers 10 times smaller volume, smaller weight, and smaller power consumption; greater sensitivity; and optical isolation for use in extreme environments. The status of the technology development will be summarized, and the potential application of the receiver to NASA space communications systems will be described.

Pouch, John↗

Spatially resolved microlensing time-scale distributions across the Galactic bulge with the VVV survey

ABSTRACT We analyse 1602 microlensing events found in the VISTA Variables in the Via Lactea (VVV) near-infrared (NIR) survey data. We obtain spatially resolved, efficiency-corrected time-scale distributions across the Galactic bulge (|ℓ| < 10°, |b| < 5°), using a Bayesian hierarchical model. Spatially resolved peaks and means of the time-scale distributions, along with their marginal distributions in strips of longitude and latitude, are in agreement at a 1σ level with predictions based on the Besançon model of the Galaxy. We find that the event time-scales in the central bulge fields (|ℓ| < 5°) are on average shorter than the non-central (|ℓ| > 5°) fields, with the average peak of the lognormal time-scale distribution at 23.6 ± 1.9 d for the central fields and 29.0 ± 3.0 d for the non-central fields. Our ability to probe the structure of the bulge with this sample of NIR microlensing events is limited by the VVV survey’s sparse cadence and relatively small number of detected microlensing events compared to dedicated optical surveys. Looking forward to future surveys, we investigate the capability of the Roman telescope to detect spatially resolved asymmetries in the time-scale distributions. We propose two pairs of Roman fields, centred on (ℓ = ±9, 5°, b = −0.125°) and (ℓ = −5°, b = ±1.375°) as good targets to measure the asymmetry in longitude and latitude, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid solution for high-speed target acquisition and identification systems

A typical hierarchy for a general object recognition problem consists of object detection, classification and identification. This paper establishes necessary building blocks required for high-speed object recognition applications. An architecture that combines digital and optical processing, exploiting current image processing techniques for detection and classification, and optical processing hardware is described. An optical processing scheme is suggested for the identification aspect. Numerical results of each proposed concept are presented.

Udomkesmalee, Suraphol↗

Fiber optic and laser sensors X; Proceedings of the Meeting, Boston, MA, Sept. 8-11, 1992

Topics addressed include acoustic and pressure sensors; fiber optic gyros; electric and magnetic field sensors; bend, strain, and temperature sensors; industrial applications of sensors; and processing techniques. Particular attention is given to fiber optic interferometric acoustic sensors for wind tunnel applications, polished coupler and resonator fabrication, second-harmonic detection for rotation sensing in fiber optic gyros, simplified control theory in closed-loop fiber optic gyroscopes, and a Fabry-Perot sensor with digital signal processing for the measurement of magnetostriction. Also discussed are a Bragg fiber laser sensor, commercialization of fiber optic strain gauge systems, thermal ignition in hazardous environments due to stray light from optical fibers, a system for absolute measurements by interferometric sensors, and high-performance interferometric demodulation techniques.

Udd, Eric↗

A semi-Lagrangian method for detecting and tracking deep convective clouds in geostationary satellite observations

Automated methods for the detection and tracking of deep convective clouds in geostationary satellite imagery have a vital role in both the forecasting of severe storms and research into their behaviour. Studying the interactions and feedbacks between multiple deep convective clouds (DCC), however, poses a challenge for existing algorithms due to the necessary compromise between false detection and missed detection errors. We utilise an optical flow method to determine the motion of deep convective clouds in GOES-16 ABI imagery in order to construct a semi-Lagrangian framework for the motion of the cloud field, independently of the detection and tracking of cloud objects. The semi-Lagrangian framework allows severe storms to be simultaneously detected and tracked in both spatial and temporal dimensions. For the purpose of this framework we have developed a novel Lagrangian convolution method and a number of novel implementations of morphological image operations that account for the motion of observed objects. These novel methods allow the accurate extension of computer vision techniques to the temporal domain for moving objects such as DCCs. By combining this framework with existing methods for detecting DCCs (including detection of growing cores through cloud top cooling and detection of anvil clouds using brightness temperature), we show that the novel framework enables reductions in errors due to both false and missed detections compared to any of the individual methods, reducing the need to compromise when compared with existing frameworks. The novel framework enables the continuous tracking of anvil clouds associated with detected deep convection after convective activity has stopped, enabling the study of the entire life cycle of DCCs and their associated anvils. Furthermore, we expect this framework to be applicable to a wide range of cases including the detection and tracking of low-level clouds and other atmospheric phenomena. In addition, this framework may be used to combine observations from multiple sources, including satellite observations, weather radar and reanalysis model data.

54 ENVIRONMENTAL SCIENCES↗

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗