Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Controlled shear/tension fixture

A test fixture for simultaneously testing two material test samples is provided. The fixture provides substantially equal shear and tensile stresses in each test specimens. By gradually applying a load force to the fixture only one of the two specimens fractures. Upon fracture of the one specimen, the fixture and the load train lose contact and the second specimen is preserved in a state of upset just prior to fracture. Particular advantages of the fixture are (1) to control the tensile to shear load on the specimen for understanding the effect of these stresses on the deformation behavior of advanced materials, (2) to control the location of fracture for accessing localized material properties including the variation of the mechanical properties and residual stresses across the thickness of advanced materials, (3) to yield a fractured specimen for strength measurement and an unfractured specimen for examining the microstructure just prior to fracture.

36 MATERIALS SCIENCE↗

Nondestructive Examination for Nuclear Power Plant Cable Aging Management Programs

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program (AMP) to justify cable performance under normal operation as well as accident conditions. This paper addresses various NDE technologies that constitute the essence of an acceptable aging management program.

cable aging inspection↗

Mechanical Response of Cr-Coated Zircaloy-4 Cladding to Pellet-Cladding Interactions

Chromium-coated zircaloy is a promising accident tolerant fuel (ATF) cladding design which can help mitigate high temperature oxidation. The mechanical response of the cladding during and after loading may be altered by the Cr coating throughout anticipated operational and accident occurrences such as a pellet-cladding interaction (PCI). In this work, the mechanical behavior of Cr-coated and uncoated cold worked stress-relieved (CWSR) Zircaloy-4 (Zry-4) cladding to PCI loading conditions are studied. Stress relaxation tests are performed on CWSR Zry-4 cladding using full-tube axial tension and internal pressurization to investigate mechanical anisotropy and rate-limiting deformation mechanisms of the uncoated Zry-4. These results are compared to internal pressure testing results of similar cladding with physical vapor deposition (PVD) Cr-coating to reveal how the Cr-coating affects the cladding mechanical response. Findings are discussed in the context of ATF cladding performance during operation and storage.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

NETEC COLD CRUCIBLE INDUCTION MELTER DEMONSTRATION FOR SRNL WITH SIMULATED SLUDGE BATCH 4 DWPF WASTE

Cold Crucible Induction Melter (CCIM) Technology is being considered as a possible next generation melter for the Defense Waste Processing Facility (DWPF). Initial and baseline demonstrations that vitrified a Sludge Batch 4 (SB4) simulant at a waste loading of 50 weight percent (versus about 38 weight percent in the current DWPF Melter) were performed by the Nuclear Engineering and Technology Institute (NETEC) in South Korea via a subcontract from the Washington Savannah River Company (WSRC). This higher waste loading was achieved by using a CCIM which can run at higher glass processing temperatures (1250 C and higher) than the current DWPF Melter (1150 C). Higher waste loadings would result in less canisters being filled and faster waste throughput at the DWPF. The main demonstration objectives were to determine the maximum melt rate/waste throughput for the NETEC CCIM with a Sludge Batch 4 simulant as well as determine the viability of this technology for use in the DWPF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reference (Axially Graded) Low Enriched Uranium Fuel Design for the High Flux Isotope Reactor (HFIR)

During the past five years, staff at the Oak Ridge National Laboratory (ORNL) have studied the issue of whether the HFIR could be converted to low enriched uranium (LEU) fuel without degrading the performance of the reactor. Using state-of-the-art reactor physics methods and behind-the-state-of-the-art thermal hydraulics methods, the staff have developed fuel plate designs (HFIR uses two types of fuel plates) that are believed to meet physics and thermal hydraulic criteria provided the reactor power is increased from 85 to 100 MW. The paper will present a defense of the results by explaining the design and validation process. A discussion of the requirements for showing applicability of analyses to approval for loading the fuel to HFIR lead test core irradiation currently scheduled for 2016 will be provided. Finally, the potential benefits of upgrading thermal hydraulics methods will be discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of Blending and In-Tank Pretreatment on Direct Feed Hanford High Level Waste Vitrification - 18434

A direct feed high level waste (DFHLW) option is under consideration for early operations of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). In this option, the Pretreatment Facility would be bypassed in order to support an earlier start-up of the HLW Vitrification Facility. For HLW, this would mean that ultrafiltration and caustic leaching that would otherwise have been performed either would not be performed or would be replaced by interim pretreatment functions such as in-tank washings. These changes could result in higher aluminum contents, higher chromium contents, higher fractions of supernate, and lower solids contents in the HLW feed. As a result, glass formulations and downstream vitrification operations will be impacted. In the present work, we investigate the effects of various waste blending and in-tank pretreatment scenarios on DFHLW glass waste loadings, canister counts, and processing rates. Eleven source tanks and five waste groups were selected for the studies of waste blending. In addition, the five waste groups selected were the subjects of an in-tank pretreatment study. Glass property-composition models and melter test data were used to calculate waste loadings, canister counts, processing rates, and treatment durations for a range of DFHLW scenarios. The processing scenarios were defined by the types of waste blending and in-tank pretreatment that were assumed. Blending cases were evaluated that ranged between the 'No Blend' and 'Total Blend' extremes and included pairwise blending (blending of two source tanks, either completely or in various proportions) and macro-batches formed from various combinations of the source tanks. Over 36,000 possible pairwise blending scenarios were evaluated and an optimal retrieval/blending sequence was identified. The waste loading of this optimal sequence is within 0.03 wt% of the 'Total Blend' case. Further, a total of 38 retrieval sequences were identified that have waste loadings within 0.1 wt% of the 'Total Blend' case. To evaluate the effects of in-tank pretreatment, an in-tank wash/settle/decant process was assumed and tank-specific wash factors were employed. Washing of the macro-batch blends gave a general increase in HLW loading, decrease in canister count, and decrease in glass yield. Glass yields are towards the low end of the values expected for the WTP, which could lead to lower than nominal glass production rates. The waste loading increases and canister count reductions with washing were small for two of the wastes indicating that direct treatment of the unwashed waste may be practical. For wastes that are relatively low in sulfate and halides, excessive washing is counterproductive. The results highlight the importance of maintaining high solids content in the HLW feed to maintain glass production rates. The results also illustrate that the optimum washing strategy will need to be evaluated on a tank-to-tank basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Validation of the Earthquake Resistance of a Full-Scale Model of RBMK-1000 Graphite Stack with Post-Repair Characteristics

In providing justification for the operational safety of RBMK-1000 power units with graphite stack distortion, earthquake resistance tests were performed on a full-scale model of RBMK graphite stack under seismic platform conditions. The tests were performed for three mutually perpendicular axes of the model successively for seismic loads corresponding to magnitudes 6, 7 and 8 on the MSK-64 scale. The tests confirmed the earthquake resistance of the graphite stack for prescribed loads. The results were used to verify the FEMGR code (Kurchatov Institute) and the LEGAK-DF finite-element software system (RFYaTs – VNIIEF) for purposes of computational validation of the earthquake resistance of the post-repair restored RMBK-1000 core.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Effective Compression Ratio on Gasoline-Diesel Dual-Fuel Combustion in a Heavy-Duty Engine Using Variable Valve Actuation

Dual-fuel combustion using port-injected gasoline with a direct diesel injection has been shown to achieve low-temperature combustion with moderate peak pressure rise rates, low engine-out soot and NOx emissions, and high indicated thermal efficiency. A key requirement for extending high-load operation is moderating the reactivity of the premixed charge prior to the diesel injection. Reducing compression ratio, in conjunction with a higher expansion ratio using alternative valve timings, decreases compressed charge reactivity while maintain a high expansion ratio for maximum work extraction. Experimental testing was conducted on a 13L multi-cylinder heavy-duty diesel engine modified to operate dual-fuel combustion with port gasoline injection to supplement the direct diesel injection. The engine employs intake variable valve actuation (VVA) for early (EIVC) or late (LIVC) intake valve closing to yield reduced effective compression ratio. Testing was conducted at a mid-load operating condition using a gasoline-diesel dual-fuel operating strategy. The impact on dual-fuel engine performance and emissions with respect to varying effective compression ratio is quantified within this study. As effective compression ratio is reduced, overall massflow through the engine decreases, yielding both higher gas exchange efficiencies and increased heat transfer losses. With constant combustion phasing gasoline/diesel fueling fraction, and NOx emissions held constant, overall brake thermal efficiency remains relatively constant across effective compression ratios.

Ickes, Andrew↗

Helium Release During Fracture and Granular Fragmentation of Rocks

Geogenic Helium-4 ( 4 He) in-situ increases locally in regions of large deformation generated naturally or anthropogenically. This gas release by deformation is a potential geochemical precursor signal for subsurface deformation. To evaluate the applicability of 4 He degassing for correlating deformation in different lithologies, we conducted high force crush tests, up to 97,800 N axial load, to assess the total 4 He released during fragmentation of the rocks. We observed that the highest 4 He released occurred in the sedimentary rocks and that release correlated strongly with lithologic age and U/Th content. Microstructural changes of the pre- and post-test rocks indicate that the degree of grain size reduction relates directly to the total 4 He released during crushing. The range of in-place 4 He was calculated based XRF measurements of uranium and thorium in each lithology, with the results indicating that the majority of the trapped 4 He was not released. However, the 4 He released by deformation depended upon how the each rock deformed during deformation and the degree of grain size reduction. We postulate that 4 He precursor signals can be used to understand subsurface deformation only if geomechanical and geochemical conditions for 4 He enrichment in a lithology are met.

Deformation signals↗

Enhancing Autonomous Control of Microreactors Using Multi-Agent Reinforcement Learning

In order for microreactors to be economically competitive, operation costs will need to be minimized through some degree of autonomous control. Previous work has demonstrated the effectiveness of reinforcement learning (RL) for load-following control in a drum-controlled microreactor. This study extends that work by exploring the potential of RL to independently control each of the reactor’s drums. We compare a single-agent RL approach with a multi-agent RL (MARL) framework, testing them for generalization across different load-following power profiles and control timescales, and for robustness in cases of randomly disabled control drums. Since the point kinetics simulation environment used in this study cannot resolve spatial effects, we assume that in the absence of spatially localized disturbances, optimal drum movements should be symmetrical. We demonstrate that single-agent RL is able to achieve accurate performance only when symmetric actions are ignored; otherwise, it fails to train a useful controller. Meanwhile, the MARL framework performs symmetric actions by design and trains a robust, accurate agent, as evidenced by mean absolute errors in power matching of 0.41% for the training power profile, 0.68% for a profile with half the drums disabled, and 0.21% for a profile on a realistic load-following time horizon.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Improved Processing of High Alloy Steels for Wear Components in Energy Generation Systems, Transportation and Manufacturing Systems

Oak Ridge National Laboratory (ORNL), in Partnership with Avure Technologies Inc. and Carpenter Technology Corporation, explored methods to improve durability of steels considered essential to bearings in wind turbine applications by using hot isostatic pressing of steel alloy powders as a manufacturing method. The objective of the project was to evaluate the wear mechanism of selected high alloy tool steels, 440C, 440XH, and M62, fabricated by powder metallurgy (PM) techniques via the hot isostatic press (HIP) process, and compare these results to two conventionally produced wrought alloys, 52100 and M50. Samples from the five candidate metals were characterized microstructurally via optical and scanning microscopy methods. A micro-pit wear testing machine was purchased and used to simulate bearing loads in a wind turbine gear box The candidate samples were subsequently heat treated in accordance with industrial protocols and machined into wear test specimens suitable for the micro-pit wear testing machine. Wear testing produced surfaces that were subsequently analyzed for wear and damage using both optical microscopy and scanning electron microscopy methods. Optimized rolling-sliding experiments with a relatively small slip ratio (5%) and higher load (650N) exhibited signs of abrasive wear on all specimens, but not all specimens had the same degree of micro-pitting damage. The conventional wrought 52100 steel had the most severe micro-pitting, consisting of distorted craters, many of which were connected by micro-cracks. Cross-sectional examination showed multiple micro-cracks extending into the alloy microstructure from the same pit. The depth of the cracks was several times the depth of the micro-pit. Type 440XH had the least amount of micro-pitting damage under similar test conditions. Micro-pits on 440HX were more localized and the micro-cracks associated with them tended to avoid carbides during propagation. Abrasive processes were observed on all the test specimens and were produced by debris from mico-pitting. The combination of micro-pitting in conjunction with abrasive processes could work together to worsen the surface damage, diminishing bearing service life. The results suggest that there is a potential advantage of PM consolidated high alloy tool steels, such as 440XH produced via hot isostatic pressing to better resist micro-pitting when compared to other alloy types and wrought processing methods.

Peter, William H.↗

Cracking Behavior of Irradiated Ex-Plant Materials

The cracking behavior of reactor core internal materials is a key factor for the long-term safety and availability of light water reactors. Subject to high-temperature coolant, thermal and mechanical loading, and neutron irradiation, reactor core internal materials are susceptible to several degradation mechanisms during power operation. To understand the long-term effects of neutron irradiation, irradiated materials harvested from a decommissioned reactor were studied for their cracking susceptibility and fracture resistance. Small compact-tension specimens were machined from different locations on the baffle plates with irradiation doses ranging from 0.06 to 48.5 dpa. Crack growth rate and fracture toughness J-resistance (J-R) curve tests were performed on these specimens in a simulated light water reactor environment, and the fracture morphologies of the tested samples were examined with a scanning electron microscope. All samples behaved similarly under cyclic loading, and no deteriorated corrosion-fatigue behavior was observed in the test environments. Under constant load, no elevated cracking susceptibility was observed either in these samples at low stress intensity factors. However, a rapid cracking behavior featuring very high crack growth rates was observed in several high-dose samples. This rapid crack growth behavior was activated when the applied stress intensity factor, K, was sufficiently high. Once activated, the rapid crack growth remained steady even when the K was lowered to the pre-activation level and stopped only when the K was reduced drastically. Yet, the rapid crack growth could be re-activated repeatedly in these samples by raising the K above the initial activation level. This rapid cracking response may be related to the severe irradiation embrittlement experienced by these samples. The J-R curve tests performed with these samples showed a significant decline in fracture toughness with increasing neutron irradiation. Local cracking at the crack tip facilitated by the severe irradiation embrittlement of this material may be responsible for the rapid crack growth behavior demonstrated by this decommissioned material.

36 MATERIALS SCIENCE↗