Large-area radiation counters for low-level detection
Technology of multiwire proportional radiation counters is adapted to detection of low-level beta and X ray emitters such as in tracers and leak detection systems.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Technology of multiwire proportional radiation counters is adapted to detection of low-level beta and X ray emitters such as in tracers and leak detection systems.
Poppet-and-seat combination is useful in fluid-control system that has to operate at high temperatures with low leak rates. Contaminants in flow stream are removed before they reach sealing surfaces by altering direction of flow several times before it enters poppet-and-seat flow passage. Particles are separated and deposited on surfaces not affecting sealing performance.
Results of the effort of designing, fabricating, and testing of a 40 joules/lb (88.2 joules/Kg) high voltage energy storage capacitor suitable for operating a pulsed plasma thruster in a vacuum environment for millions of pulses are presented. Using vacuum brazing and heli-arc welding techniques followed by vacuum and high pressure helium leak tests it was possible to produce a hermetically sealed relatively light weight enclosure for the dielectric system. An energy density of 40 joules/lb was realized with a KF-polyvinylidene fluoride dielectric system. One capacitor was D.C. life tested at 4 KV (107.8 joules/lb) for 2,000 hours before it failed. Another exceeded 2,670 hours without failure at 38.3 joules/lb. Pulse life testing in a vacuum exceeded 300,000 discharges with testing still in progress. The D.C. life test data shows a small decrease in capacitance and an increase in dissipation factor with time. Heat transfer from the load to the capacitor must also be considered besides the self-heat generated by the capacitor.
A method for making a glass-to-metal seal is described. A domed metal enclosure having a machined seal ring is fitted to a glass post machined to a slight taper and to a desired surface finish. The metal part is then heated by induction in a vacuum. As the metal part heats and expands relative to the glass post, the metal seal ring, possessing a higher coefficient of expansion than the glass post, slides down the tapered post. Upon cooling, the seal ring crushes against the glass post forming the seal. The method results in a glass-to-metal seal possessing extremely good leak resistance, while the parts are kept clean and free of the contaminants.
Rain attenuation and depolarization data collected on the communications technology satellite 11.7 GHz downlink, and changes made in equipment following rain leak damage to the parametric amplifier are discussed. A 15 GHz radar system is described.
An inlet leak is described for sampling gases, more specifically, for selectively sampling multiple fluids. This fluid sampling device includes a support frame. A plurality of fluid inlet devices extend through the support frame and each of the fluid inlet devices include a longitudinal aperture. An opening device that is responsive to a control signal selectively opens the aperture to allow fluid passage. A closing device that is responsive to another control signal selectively closes the aperture for terminating further fluid flow.
The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.
A solar thermal power plant with a field of collectors, each locally heating some transport fluid, requires a pipe network system for eventual delivery of energy power generation equipment. For a given collector distribution and pipe network geometry, a technique is herein developed which manipulates basic cost information and physical data in order to design an energy transport system consistent with minimized cost constrained by a calculated technical performance. For a given transport fluid and collector conditions, the method determines the network pipe diameter and pipe thickness distribution and also insulation thickness distribution associated with minimum system cost; these relative distributions are unique. Transport losses, including pump work and heat leak, are calculated operating expenses and impact the total system cost. The minimum cost system is readily selected. The technique is demonstrated on six candidate transport fluids to emphasize which parameters dominate the system cost and to provide basic decision data. Three different power plant output sizes are evaluated in each case to determine severity of diseconomy of scale.
This paper describes analytical techniques, fabrication development, and test results for composite tubing that has many applications in aerospace and commercial cryogenic installations. Metal liner fabrication is discussed in detail with attention given to resistance-welded liners, fusion-welded liners, chem-milled tubing liners, joining tube liners and end fittings, heat treatment and leak checks. Composite overwrapping, a second method of tubing fabrication, is also discussed. Test programs and analytical correlation are considered along with composite tubing advantages such as minimum weight, thermal efficiency and safety and reliability.
Module, consisting of transparent plastic cylinder containing separate suction and calibration chambers, allows static-pressure orifices to be calibrated, and rapidly checked for leaks. Device is compact, saves time, and improves accuracy, and reliability of pressure measurements.
Beta alumina tubes having walls 700 microns, 300 microns, and 140 microns were processed by extrusion and sintering utilizing Ford proprietary binder and fabrication systems. Tubes prepared by this method have properties similar to tubes prepared by isostatic pressing and sintering, i.e. density greater than 98% of theoretical and a helium leak rate less than 3 x 10 to the -9th power cc/sq cm/sec. Ford ultrasonic bonding techniques were used for bonding beta alumina end caps to open ended beta -alumina tubes prior to sintering. After sintering, the bond was hermetic, and the integrity of the bonded area was comparable to the body of the tube.
Attempts are made to provide a total design of a Microbial Load Monitor (MLM) system flight engineering model. Activities include assembly and testing of Sample Receiving and Card Loading Devices (SRCLDs), operator related software, and testing of biological samples in the MLM. Progress was made in assembling SRCLDs with minimal leaks and which operate reliably in the Sample Loading System. Seven operator commands are used to control various aspects of the MLM such as calibrating and reading the incubating reading head, setting the clock and reading time, and status of Card. Testing of the instrument, both in hardware and biologically, was performed. Hardware testing concentrated on SRCLDs. Biological testing covered 66 clinical and seeded samples. Tentative thresholds were set and media performance listed.
A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.
A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.
The background data obtained from an actively shielded Ge(Li) spectrometer flown on a balloon were analyzed and a preliminary model was developed to explain background features including the intensity and time profile of line emission. These features can be explained by a combination of secondary radiation originating in the CsI shield and atmospheric secondary radiation leaking through it.
A simplified analytical model of leakage into a wing-elevon cove under high speed external flow conditions is presented. The model accounts for convection from the high temperature gas stream leaking into the cove, radiation exchanges between walls and with the environment, and axial conduction within the channel walls. Comparisons are made of predicted and measured wall temperatures of an experimental wing-elevon-cove model that was tested in a hypersonic wind tunnel. Analytically determined Nusselt numbers for laminar flow entrance conditions are compared with those calculated from experimentally measured gas temperatures, wall temperatures and wall heating rates. Although reasonable agreement appears to be indicated, testing times much larger than those of the present test program (5 seconds) would be desirable in evaluating the reliability and accuracy of the simplified model.
Jet noise is modeled by particle-attached quadrupoles convected with the velocity of the actual fluid but positioned near a hypothetical instability-free vortex sheet. The strength of each quadrupole is Lighthill's stress tensor per unit mass. The work of Mani (1976) has shown that this type of model agrees well with experiment, and the present work establishes some of the equivalent sources needed for an exact analogy. The instability waves of the shear layer, as they grow into turbulence, are heard as sound that builds up as a precursor of the main turbulence-driven field. The circular compact jet is examined in some detail, and it is found that when the jet is very light it can provide a waveguide in which the effects of source activity persist for some time but eventually leak out as sound. This interaction greatly distorts the free field characteristics of the turbulent sources, so that Reynolds-stress-induced waves have an intensity that scales with the fourth power of jet velocity.
An experimental LOX heat-transfer study and a LOX-cooled thrust-chamber demonstration program are summarized. Heat transfer to supercritical oxygen was investigated at 17 to 34.5 MPa (2460 to 5000 psia), and heat fluxes up to 90 MW/sq m (55 Btu/sq in.-sec). Experimental data obtained previously were correlated along with these recent data, and a design equation was derived which correlates 95% of the data within + or - 30%. Liquid-oxygen-cooled thrust chambers have been designed using this correlation and are currently being fabricated. A test program is planned for evaluating the LOX-cooled design concept using NASA test facilities. The purpose of these tests is to verify the LOX cooling correlation in a high-pressure liquid rocket engine and to determine the effects of a LOX coolant leak.