Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

An investigation of kV CBCT image quality and dose reduction for volume-of-interest imaging using dynamic collimation

Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kilovoltage-cone beam CT (CBCT) using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of 1D translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian On-Board Imager system. CBCT and planar image quality were investigated as a function of aperture radius, while maintaining the same dose to the VOI, for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various sizes VOI were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 to 2.4 cm (at isocenter). Depending upon VOI location and size, dose was reduced to 16%–90% of the full-field value along the central axis plane and down to 4% along the axis of rotation, while maintaining the same dose to the VOI compared to full-field techniques. When maintaining constant dose to the VOI, this change in iris diameter corresponds to a factor increase of approximately 1.6 in image contrast and a factor decrease in image noise of approximately 1.2. This results in a measured gain in contrast-to-noise ratio by a factor of approximately 2.0. Conclusions: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.

60 APPLIED LIFE SCIENCES↗

Measurement of a cross-sectional profile of a thread gauge using a sinusoidally vibrating interference pattern

A sinusoidally vibrating interference pattern (SVIP) is used as an exact spatial scale in order to measure a cross-sectional profile of a thread gauge. The SVIP is projected on the thread gauge surface, and lights diffracted and reflected from the end points of the thread gauge surface are extracted by spatial frequency filtering in an imaging system to make an image of the end points whose positions are decided by the peak positions of amplitude distributions in the image. The coordinates of the end points or the cross-sectional profile of the thread gauge is obtained from the phases measured at the positions of the end points, phase distribution of the SVIP on a CCD image sensor, and the pixel positions of the CCD image sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum Super-resolution Bioimaging using Massively Entangled Multimode Squeezed Light

This report presents a new method for realizing a super-resolution quantum imaging using massively entangled multimode squeezed light (MEMSL). Each branch of the entangled multimode light interacts with the sample and bears the spatially varying optical phase delay. When imaging optics with finite pupil sizes are used, information is lost. Thanks to the analyticity in the Fourier plane, a noiseless measurement would recover the lost information and accomplish super resolution imaging beating the Rayleigh diffraction limit. I proved rigorously in a fully quantum formalism and presented that (1) such information recovery is possible and (2) the information recovery can be accomplished with much less resources when MEMSL is used than those needed in any non-entangled or non-squeezed classical imaging method. Furthermore, the action of the optical loss in the imaging system that degrades the imaging performance is also rigorously analyzed and presented. Several bioimaging applications that can benefit tremendously from the proposed quantum imaging scheme are also suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VICAR-DIGITAL image processing system

Computer program corrects various photometic, geometric and frequency response distortions in pictures. The program converts pictures to a number of elements, with each elements optical density quantized to a numerical value. The translated picture is recorded on magnetic tape in digital form for subsequent processing and enhancement by computer.

Billingsley, F.↗

Virtual-image display system for flight simulators

Dual TV monitor and collimated lens system in windscreens of standard aircraft cockpit simulator permits both pilot and copilot to simultaneously view three dimensional presentation. Proper design of complete system permits depth and viewpoint of visual displays to be accurately presented.

Chase, W. D.↗

The ERTS wideband image communication system.

The ERTS payload includes a three camera return beam vidicon (RBV) television system and a four channel multispectral scanner system (MSS). The communications system described includes spacecraft wideband equipment plus unique payload processing equipment located at three NASA tracking stations. The RBV information, transmitted as analog FM with a baseband response of dc to 3.2 MHz, is telemetered, processed and recorded on a wideband video recorder. The MSS data, consisting of 24 analog sensor outputs, is digitized and encoded as 15 megabit per second PCM. The MSS data is then transmitted as analog FM, demultiplexed, and recorded on a 25 channel recorder. It is shown that bit error rate is an excellent indicator of MSS link performance while signal-to-noise ratio and distortion vs frequency adequately define RBV link performance.

Pandelides, J.↗

Digital image-rectification system

System removes spatial distortions from data and brings data into conformance with Universal Transverse Mercator map projection, produces digital output products suitable for further machine processing and analysis, and fills need for geometrically corrected Landsat multispectral scanner digital data in several remote sensing application areas.

Van Wie, P. H.↗

One-third scale model of an offset fed scanning antenna for the shuttle imaging microwave system

An experimental study is reported, involving the design, fabrication, and measurement of a one-third scale model of the 4m diameter parabolic torus reflector with a Gregorian feed for the SIMS application. Antenna pattern measurements of the model at 60 and 30 GHz are presented to verify the predictions of a geometrical optics analysis upon which the antenna design was based. It is shown that the antenna measurements bear out the geometrical optics analysis in every respect and that the Gregorian subreflector feed is usable at all frequencies above at least 10 Ghz in the full size SIMS antenna. The fabrication of the model antenna is discussed, including a computerized technique for fabricating the transcendental subreflector shape with a numerically controlled machine.

Gustincic, J. H.↗

The Shuttle imaging microwave system experiment

The purpose of the Shuttle microwave system experiment (SIMS) is to utilize the capabilities of the Space Shuttle to perform passive microwave measurements of thermal emission from the earth's atmosphere and surface, which can be interpreted in terms of meaningful atmospheric and geophysical parameters. The paper is a status report of an ongoing definition phase study of SIMS. The wavelengths and observable parameters for the SIMS channels are identified. The SIMS instrument is discussed with particular reference to the antenna system. A system consisting of a parabolic torus reflector offset fed by a number of feeds and radiometers on a rotating wheel is determined to be the best antenna configuration for SIMS. A tentative data flow diagram for SIMS is also provided.

Waters, J. W.↗

Inconsistencies in tape read and tape write programs on the I-100 image analysis system

The author has identified the following significant results. The tape read and write programs currently available on the 1-100 perform their intended functions of reading and writing tapes, but are difficult to use because they contain a number of inconsistencies. These inconsistencies can often be overcome by the use of work-around procedures and by trial and error, which is an inefficient use of expensive computer systems that should not be necessary.

Hocutt, W. T.↗

Visual imaging control systems of the Mariner to Jupiter and Saturn spacecraft

Design and fabrication of optical systems for the Mariner Jupiter Saturn (Voyager) mission is described. Because of the long distances of these planets from the sun, the spacecraft was designed without solar panels with the electricity generated on-board by radio-isotope thermal generators (RTG). The presence of RTG's and Jupiter radiation environment required that the optical systems be fabricated out of radiation stabilized materials. A narrow angle and a wide angle camera are located on the spacecraft scan platform, with the narrow angle lens a modification of the Mariner 10 lens. The optical system is described, noting that the lens was modified by moving the aperture correctors forward and placing a spider mounted secondary mirror in the original back surface of the second aperture corrector. The wide angle lens was made out of cerium doped, radiation stabilized optical glass with greatest blue transmittance, which would be resistant to RTG and Jupiter radiation.

Larks, L.↗

A computer algorithm for performing interactive algebraic computation on the GE Image-100 system

A subroutine which performs specialized algebraic computations upon ocean color scanner multispectral data is presented. The computed results are displayed on a video display. The subroutine exists as a component of the aircraft sensor analysis package. The user specifies the parameters of the computations by directly interacting with the computer. A description of the conversational options is also given.

Hart, W. D.↗

Image display system 511

The experience of the Idaho Department of Water Resources Remote Sensing Unit in bringing on line their System 511 is described. The system 511 is run on a PDP minicomputer. The minimum system hardware configuration is an 11/34 with a minimum core of 128 K word, 10 megabytes of direct access disk and a floating point processor. The required software configuration is an RSX 11M V 3.2 operating system with a FORTRAN IV plus compiler. The structure of System 511 is a series of hierarchical modular software units. Problems occurring during the systems installation are discussed, and the system operating and error detection capabilities and documentation evaluated.

Gross, M.↗