Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Angled Injection: Turbulent Flow Hybrid Bearings Comparison to Test Results

Hydrostatic/hydrodynamic (hybrid) journal bearings handling process liquids have limited dynamic stability characteristics and their application as support elements to high speed flexible rotating systems is severely restricted. Measurements on water hybrid bearings with angled orifice injection have demonstrated improved rotordynamic performance with virtual elimination of cross-coupled stiffness coefficients and null or negative whirl frequency ratios. A bulk-flow model for prediction of the static performance and force coefficients of hybrid bearings with angled orifice injection is advanced. The analysis reveals that the fluid momentum exchange at the orifice discharge produces a pressure rise in the hydrostatic recess retards the shear flow induced by journal rotation, and thus, reduces cross-coupling forces. The predictions from the model are compared with experimental measurements for a 45 deg. angled orifice injection, 5 recess water hybrid bearing operating at 10.2, 17.4, and 24.6 krpm and with supply pressures of 4, 5.5, and 7 MPa. The correlations include recess pressures, flow rates, and rotordynamic force coefficients at the journal centered position.

SanAndres, Luis↗

Experimental study of three exit pressure distortions on turbine performance

A cold flow air test of the Space Shuttle Main Engine (SSME) High Pressure Fuel Turbopump (HPFTP) turbine was conducted with a circumferential pressure distortion at the turbine exit. The effects of three circumferential exit pressure distortions on turbine efficiency and pressure ratio, are presented. Circumferential and radial total pressure, total temperature, static pressure, and flow angle distributions at the turbine exit are also presented. Efficiency and total-to-total pressure ratio are shown to have a circumferential variation as high as 13.7 percent (or points of efficiency) and 7.1 percent, respectively. A slight pressure distortion was measured downstream of the first stage nozzle and the distortion increased across subsequent blade rows to a maximum downstream of the second stage rotor for all three plates. A brief discussion of the test facility, model, instrumentation, and test plan is given for completeness.

Gaddis, Stephen W.↗

A new technique for reducing test section noise in supersonic wind tunnels

A new technique is presented for obtaining a low-noise test environment in a high-speed wind tunnel. This technique utilizes the fact that the primary noise source for high supersonic/hypersonic wind tunnels is radiated noise from the turbulent, tunnel-wall boundary layer. Because of the high directionality of sound in supersonic flows this test section noise originates far upstream on the walls of the nozzle at the 'acoustic origin'. It is shown that tailoring the nozzle contour to reduce the acoustic origin Mach number significantly reduces the noise level in the upstream half of the nozzle test rhombus. Experimental noise measurements are presented from a conventional, Mach 5 nozzle and are compared with measurements from a rapid-expansion, Mach 5 nozzle.

Anders, J. B.↗

Investigation of ALEGRA shock hydrocode algorithms using an exact free surface jet flow solution.

Computational testing of the arbitrary Lagrangian-Eulerian shock physics code, ALEGRA, is presented using an exact solution that is very similar to a shaped charge jet flow. The solution is a steady, isentropic, subsonic free surface flow with significant compression and release and is provided as a steady state initial condition. There should be no shocks and no entropy production throughout the problem. The purpose of this test problem is to present a detailed and challenging computation in order to provide evidence for algorithmic strengths and weaknesses in ALEGRA which should be examined further. The results of this work are intended to be used to guide future algorithmic improvements in the spirit of test-driven development processes.

Hanks, Bradley Wright.↗

Flight Tests of a Supersonic Natural Laminar Flow Airfoil

IR thermography was used to characterize the transition front on a S-NLF test article at chord Reynolds numbers in excess of 30 million Changes in transition due to Mach number, Reynolds number, and surface roughness were investigated - Regions of laminar flow in excess of 80% chord at chord Reynolds numbers greater than 14 million IR thermography clearly showed the transition front and other flow features such as shock waves impinging upon the surface A series of parallel oblique shocks, of yet unknown origin, were found to cause premature transition at higher Reynolds numbers. NASA has a current goal to eliminate barriers to the development of practical supersonic transport aircraft Drag reduction through the use of supersonic natural laminar flow (S-NLF) is currently being explored as a means of increasing aerodynamic efficiency - Tradeoffs work best for business jet class at M<2 Conventional high-speed designs minimize inviscid drag at the expense of viscous drag - Existence of strong spanwise pressure gradient leads to crossflow (CF) while adverse chordwise pressure gradients amplifies and Tollmien-Schlichting (TS) instabilities Aerion Corporation has patented a S-NLF wing design (US Patent No. 5322242) - Low sweep to control CF - dp/dx < 0 on both wing surfaces to stabilize TS - Thin wing with sharp leading edge to minimize wave drag increase due to reduction in sweep NASA and Aerion have partnered to study S-NLF since 1999 Series of S-NLF experiments flown on the NASA F-15B research test bed airplane Infrared (IR) thermography used to characterize transition - Non-intrusive, global, good spatial resolution - Captures significant flow features well

laminar flow↗

3-D laser anemometer measurements in a labyrinth seal

The flow field inside a seven cavity labyrinth seal with a 0.00127 m clearance was measured using a 3-D laser Doppler anemometer system. Through the use of this system, the mean velocity vector and the entire Reynolds stress tensor distributions were measured for the first, third, fifth, and seventh cavities of the seal. There was one large recirculation region present in the cavity for the flow condition tested, Re = 28,000 and Ta = 7,000. The axial and radial mean velocities as well as all of the Reynolds stress term became cavity independent by the third cavity. The azimuthal mean velocity varied from cavity to cavity with its magnitude increasing as the flow progressed downstream.

Morrison, G. L.↗

Current Efforts in Immobilized Low-Activity Waste Glass Testing to Support the Hanford Site Integrated Disposal Facility - 17119

Cleanup plans for Hanford site high-level radioactive mixed tank waste calls for separating the waste into high-level waste (HLW) and low-activity waste (LAW) fractions. The fractions will be vitrified separately at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The HLW glass will be sent to an offsite geological disposal facility while the immobilized low-activity waste (ILAW) glass will be disposed at the onsite Integrated Disposal Facility (IDF). In order to inform models used to predict the performance of ILAW glass at IDF, it is necessary to understand the corrosion behavior of the glass. In this paper, we discuss tests that account for the effects of 1) solution chemistry, 2) the ion exchange reaction, and 3) secondary phase formation on the glass dissolution rate. To quantify the effects of solution chemistry, specifically changes in pH, T, and Si concentration, the single-pass flow-through (SPFT) test method is applied. A designed set of these tests results in a set of kinetic rate law parameters that are used in a glass dissolution rate law based on transition-state theory. Furthermore, for SPFT tests with relatively high concentrations of Si, an ion exchange rate is provided. Additionally, through tests such as the pressurized unsaturated flow (PUF) test method, a suite of secondary phases can be compiled. The collection of kinetic rate law parameters, the ion exchange term, and the suite of secondary phases are provided to IDF performance assessment (PA) modelers. Lastly, we present a description of the efforts made to verify and validate the use of these parameters and secondary phases through the use of a field lysimeter present at the Hanford site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Loss reduction in axial-flow compressors through low-speed model testing

A systematic procedure for reducing losses in axial-flow compressors is presented. In this procedure, a large, low-speed, aerodynamic model of a high-speed core compressor is designed and fabricated based on aerodynamic similarity principles. This model is then tested at low speed where high-loss regions associated with three-dimensional endwall boundary layers flow separation, leakage, and secondary flows can be located, detailed measurements made, and loss mechanisms determined with much greater accuracy and much lower cost and risk than is possible in small, high-speed compressors. Design modifications are made by using custom-tailored airfoils and vector diagrams, airfoil endbends, and modified wall geometries in the high-loss regions. The design improvements resulting in reduced loss or increased stall margin are then scaled to high speed. This paper describes the procedure and presents experimental results to show that in some cases endwall loss has been reduced by as much as 10 percent, flow separation has been reduced or eliminated, and stall margin has been substantially improved by using these techniques.

Wisler, D. C.↗

Comparison of Node-Centered and Cell-Centered Unstructured Finite-Volume Discretizations: Viscous Fluxes

Discretization of the viscous terms in current finite-volume unstructured-grid schemes are compared using node-centered and cell-centered approaches in two dimensions. Accuracy and complexity are studied for four nominally second-order accurate schemes: a node-centered scheme and three cell-centered schemes - a node-averaging scheme and two schemes with nearest-neighbor and adaptive compact stencils for least-square face gradient reconstruction. The grids considered range from structured (regular) grids to irregular grids composed of arbitrary mixtures of triangles and quadrilaterals, including random perturbations of the grid points to bring out the worst possible behavior of the solution. Two classes of tests are considered. The first class of tests involves smooth manufactured solutions on both isotropic and highly anisotropic grids with discontinuous metrics, typical of those encountered in grid adaptation. The second class concerns solutions and grids varying strongly anisotropically over a curved body, typical of those encountered in high-Reynolds number turbulent flow simulations. Tests from the first class indicate the face least-square methods, the node-averaging method without clipping, and the node-centered method demonstrate second-order convergence of discretization errors with very similar accuracies per degree of freedom. The tests of the second class are more discriminating. The node-centered scheme is always second order with an accuracy and complexity in linearization comparable to the best of the cell-centered schemes. In comparison, the cell-centered node-averaging schemes may degenerate on mixed grids, have a higher complexity in linearization, and can fail to converge to the exact solution when clipping of the node-averaged values is used. The cell-centered schemes using least-square face gradient reconstruction have more compact stencils with a complexity similar to that of the node-centered scheme. For simulations on highly anisotropic curved grids, the least-square methods have to be amended either by introducing a local mapping based on a distance function commonly available in practical schemes or modifying the scheme stencil to reflect the direction of strong coupling. The major conclusion is that accuracies of the node centered and the best cell-centered schemes are comparable at equivalent number of degrees of freedom.

Diskin, Boris↗

Aero-thermal Calibration of the NASA Glenn Icing Research Tunnel (2000 Tests)

Aerothermal calibration measurements and flow quality surveys were made in the test section of the Icing Research Tunnel at the NASA Glenn Research Center. These surveys were made following major facility modifications including widening of the heat exchanger tunnel section, replacement of the heat exchanger, installation of new turning vanes, and installation of new fan exit guide vanes. Standard practice at NASA Glenn requires that test section calibration and flow quality surveys be performed following such major facility modifications. A single horizontally oriented rake was used to survey the flow field at several vertical positions within a single cross-sectional plane of the test section. These surveys provided a detailed mapping of the total and static pressure, total temperature, Mach number, velocity, flow angle and turbulence intensity. Data were acquired over the entire velocity and total temperature range of the facility. No icing conditions were tested; however, the effects of air sprayed through the water injecting spray bars were assessed. All data indicate good flow quality. Mach number standard deviations were less than 0.0017, flow angle standard deviations were between 0.3 deg and 0.8 deg, total temperature standard deviations were between 0.5 and 1.8 F for subfreezing conditions, axial turbulence intensities varied between 0.3 and 1.0 percent, and transverse turbulence intensities varied between 0.3 and 1.5 percent. Measurement uncertainties were also quantified.

Gonsalez, Jose C.↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RHEOLOGICAL AND ELEMENTAL ANALYSES OF SIMULANT SB5 SLURRY MIX EVAPORATOR-MELTER FEED TANK SLURRIES

The Defense Waste Processing Facility (DWPF) will complete Sludge Batch 5 (SB5) processing in fiscal year 2010. DWPF has experienced multiple feed stoppages for the SB5 Melter Feed Tank (MFT) due to clogs. Melter throughput is decreased not only due to the feed stoppage, but also because dilution of the feed by addition of prime water (about 60 gallons), which is required to restart the MFT pump. SB5 conditions are different from previous batches in one respect: pH of the Slurry Mix Evaporator (SME) product (9 for SB5 vs. 7 for SB4). Since a higher pH could cause gel formation, due in part to greater leaching from the glass frit into the supernate, SRNL studies were undertaken to check this hypothesis. The clogging issue is addressed by this simulant work, requested via a technical task request from DWPF. The experiments were conducted at Aiken County Technology Laboratory (ACTL) wherein a non-radioactive simulant consisting of SB5 Sludge Receipt and Adjustment Tank (SRAT) product simulant and frit was subjected to a 30 hour SME cycle at two different pH levels, 7.5 and 10; the boiling was completed over a period of six days. Rheology and supernate elemental composition measurements were conducted. The caustic run exhibited foaming once, after 30 minutes of boiling. It was expected that caustic boiling would exhibit a greater leaching rate, which could cause formation of sodium aluminosilicate and would allow gel formation to increase the thickness of the simulant. Xray Diffraction (XRD) measurements of the simulant did not detect crystalline sodium aluminosilicate, a possible gel formation species. Instead, it was observed that caustic conditions, but not necessarily boiling time, induced greater thickness, but lowered the leach rate. Leaching consists of the formation of metal hydroxides from the oxides, formation of boric acid from the boron oxide, and dissolution of SiO{sub 2}, the major frit component. It is likely that the observed precipitation of Mg(OH){sub 2} and Mn(OH){sub 2} caused the increase in yield stress. The low pH run exhibited as much as an order of magnitude greater B and Li (frit components) leachate concentrations in the supernate. At high pH a decrease of B leaching was found and this was attributed to adsorption onto Mg(OH){sub 2}. A second leaching experiment was performed without any sludge to deconvolute the leach rate behavior of Frit 418 from those of the SB5 sludge-Frit 418 system. At high pH, the sludgeless system demonstrated very fast leaching of all the frit components, primarily due to fast dissolution of the main component, silica, by hydroxide anion; various semiconductor studies have established this reactivity. Overall, the frit-water system exhibited greater leaching from a factor two to almost three orders of magnitude (varying by conditions and species). The slower leaching of the sludge system is possibly due to a greater ionic strength or smaller driving force. Another possible reason is a physical effect, coating of the frit particles with sludge; this would increase the mass transfer resistance to leaching. Based on this study, the cause of clogs in the melter feed loop is still unknown. A possible explanation is that the SME product, like the simulant, is too thin and could contribute to a loss of two-phase flow which could cause plugging of a restricted and poorly mixed zone like the melter feed loop. This is feasible since a previous study of a slurry showed an increase in resistance to flow at lower flow rates. Testing with a radioactive SME sample is underway and should help understand this potential mechanism.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computational Fluid Dynamics Analysis for the Orbiter LH2 Feedline Flowliner

In phase II, additional inducer rotations are simulated in order to understand the root cause of the flowliner crack problem. CFD results confirmed that there is a strong unsteady interaction between the backflow regions caused by the LPFTP inducer and secondary flow regions in the bellows cavity through the flowliner slots. It is observed that the swirl on the duct side of the downstream flowliner is stronger than on the duct side of the upstream flowliner. Due to this swirl, there are more significant unsteady flow interactions through the downstream slots than those observed in the upstream slots. Averaged values of the local velocity at the slots were provided to the NESC-ITA flow physics acoustics team to guide them in designing the acoustics experiment. A parametric study was performed to compare the flow field in the flowliner area when one upstream slot and one corresponding downstream slot were enlarged. No significant differences were observed between the flow field obtained from the enlarged slot configuration when compared with the original configuration. More cases must be analyzed with various enlarged slot configurations to generalize this observation. The flow through the A1 test stand and the flow through the orbiter fuel feedline manifold were simulated without the LPFTP. It was observed that incoming flow to the flowliner and inducer was more uniform in the A1 test stand then in the orbiter manifold. Additionally, each engine LPFTP in the orbiter receives significantly different velocity distributions. Because of the differences observed in the computed results, it is not possible for the A1 test stand to represent the three different engine feedlines simultaneously.

Kiris, Cetin C.↗

Asymmetric lateral-directional characteristics of pointed bodies of revolution at high angles of attack

A low-speed wind-tunnel investigation was conducted in order to determine the cause of asymmetric yawing moments produced by long pointed fuselage nose shapes at high angles of attack. Force tests were conducted with a cone, tangent-ogive model, and a paraboloid of revolution over a range of Reynolds numbers from 0.15 million to 0.35 million for an angle-of-attack range from 0 deg to 75 deg and an angle-of-sideslip range of plus or minus 30 deg. Tuft and smoke flow-visualization tests were also conducted to aid in the analysis. Large asymmetric yawing moments were obtained for the cone and tangent-ogive body at high angles of attack (of the order of 40 to 60 deg). These large moments were caused by asymmetric shedding of vortex sheets off the long pointed nose. The asymmetric moments could be eliminated by use of symmetrically arranged strikes on the nose. The paraboloid of revolution did not produce a strong asymmetric flow field at high angles of attack and did not exhibit asymmetric moments.

Coe, P. L., Jr.↗

The evolution of adaptive-wall wind tunnels

Since its inception, adaptive wall wind tunnel design has developed three major configurational possibilities: streamlined walls, variable porosity walls, and segmented plenum arrangements. All of these methods have demonstrated their feasibility for transonic flow research; development programs are noted to be underway for three-dimensional adaptive wall tunnels. With the availability of advanced computational procedures, routine angle-of-incidence or Mach sweeps may be treated numerically, while adaptive wall wind tunnels are employed for complementary point-design and for testing at flow conditions that are beyond the capabilities of current numerical modeling.

Davis, S. S.↗

Atmospheric Probe Model: Construction and Wind Tunnel Tests

The material contained in this document represents a summary of the results of a low speed wind tunnel test program to determine the performance of an atmospheric probe at low speed. The probe configuration tested consists of a 2/3 scale model constructed from a combination of hard maple wood and aluminum stock. The model design includes approximately 130 surface static pressure taps. Additional hardware incorporated in the baseline model provides a mechanism for simulating external and internal trailing edge split flaps for probe flow control. Test matrix parameters include probe side slip angle, external/internal split flap deflection angle, and trip strip applications. Test output database includes surface pressure distributions on both inner and outer annular wings and probe center line velocity distributions from forward probe to aft probe locations.

Vogel, Jerald M.↗

Nuclear thermal source transfer unit, post-blast soil sample drying system

Los Alamos National Laboratory states that its mission is “To solve national security challenges through scientific excellence.” The Science Undergraduate Laboratory Internship (SULI) programs exists to engage undergraduate students in STEM work by providing opportunity to work at DOE facilities. As an undergraduate mechanical engineering intern under the SULI program at Los Alamos during the fall semester of 2016, I had the opportunity to contribute to the mission of the Laboratory while developing skills in a STEM discipline. I worked with Technology Applications, an engineering group that supports non-proliferation, counter terrorism, and emergency response missions. This group specializes in tool design, weapons engineering, rapid prototyping, and mission training. I assisted with two major projects during my appointment Los Alamos. The first was a thermal source transportation unit, intended to safely contain a nuclear thermal source during transit. The second was a soil drying unit for use in nuclear postblast field sample collection. These projects have given me invaluable experience working alongside a team of professional engineers. Skills developed include modeling, simulation, group design, product and system design, and product testing.

42 ENGINEERING↗

Heat Testing of a Prototypical SiC Foam-Based Flow Channel Insert

As part of the U.S. ITER test blanket module development effort, several flow channel insert (FCI) concepts using a variety of porous SiC and SiC/SiC composites are being developed. Using porous SiC, prototypes of FCI segments as large as 0.12 m x 0.75 m x 0.015 m were fabricated and heat tested with a maximum {Delta}T of {approx}150 C across the FCI walls. In this paper, we report on two heat tests of the FCI prototypes. The first test used radiative heating of the inside of the FCI along with convective cooling of the outside of the FCI, which resulted in a temperature drop of about {approx}147 C across the FCI wall. The second test involved partial submersion of the FCI structure in liquid PbLi, resulting in an inner wall surface temperature of about 600 C and an outer wall temperature of about 450 C ({Delta}T {approx} 150 C). Detailed thermomechanical analyses of the tests were conducted, and results of the simulations are discussed in the context of actual FCI operating conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗