Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Initial Implementation Of Machine Learning System for SRF Cavity Fault Classification at CEBAF

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is high power CW electron accelerator. It uses a mixture of two types of SRF modules, older, lower energy C20/C50 modules and newer higher energy C100 modules, arrayed in two anti-parallel linear accelerators. Accurately classifying the type of cavity faults is essential to maintaining and improving accelerator performance. Each C100 cryomodule contains eight 7-cell cavities. When a cavity fault occurs within a cryomodule, all eight cavities generate 17 waveforms each containing 8192 points. This data is exported from EPICS and saved for review. Analysis of these waveforms is time intensive and requires subject matter expertise (SME). SMEs examine the data from each event and label it according to one of several known cavity fault types. Multiple machine learning models have been developed on this labeled dataset with sufficient performance to warrant the creation of a limited machine learning software system for use by accelerator operations staff. This paper discusses the transition from model development to implementation of a prototype system.

Carpenter, A.↗

Commercial Fault Detection and Diagnostics Tools: What They Offer, How They Differ, and What’s Still Needed

It is estimated that 5%–30% energy use in commercial buildings is wasted due to faults and errors in operations. Automated fault detection and diagnostics (AFDD) technologies can address this waste by identifying (detecting) deviations from normal or expected operation (faults), and resolving (diagnosing) the type of problem or its location, minimizing the need for complex manual analysis of operational data. Although currently underutilized, AFDD is a powerful approach to ensuring efficient building operations. AFDD offers the potential to greatly improve performance, and to do so cost effectively. There is currently a diverse landscape of AFDD technologies on the market, but no common framework exists to characterize such tools, or distinguish one offering from another. It is difficult to determine from vendor websites and marketing materials key technology features and capabilities, or the overall state of the technology. In this paper, we present an AFDD characterization framework, and findings from applying the framework to survey over a dozen technologies from today’s market. This paper outlines the current state of the market, as well as outstanding needs in the industry, derived from direct engagement of, and technical assistance provided to users of AFDD technology. A core set of interrelated informational, organizational, and technical needs and barriers that must be addressed to realize the full potential of AFDD at scale are identified. Lastly, based on information gathered through a survey and discussion with both vendors and users, several opportunities to further advance the technology are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooperative Application/OS DRAM Fault Recovery

Exascale systems will present considerable fault-tolerance challenges to applications and system software. These systems are expected to suffer several hard and soft errors per day. Unfortunately, many fault-tolerance methods in use, such as rollback recovery, are unsuitable for many expected errors, for example DRAM failures. As a result, applications will need to address these resilience challenges to more effectively utilize future systems. In this paper, we describe work on a cross-layer application/OS framework to handle uncorrected memory errors. We illustrate the use of this framework through its integration with a new fault-tolerant iterative solver within the Trilinos library, and present initial convergence results.

99 GENERAL AND MISCELLANEOUS↗

Preliminary Assessment of the Surface Fault Rupture Hazard in the Vicinity of the Biosafety Level 3 Laboratory (BSL-3)

The probability of seismic hazards, in particular fault rupture hazard under or in the close proximity to the BSL-3 structure has been considered based on earlier estimates of surface fault rupture hazard (SFRH) conducted for the CMR site. Although the CMR probabilistic fault displacement hazard assessment (PFDHA) predates the most recent LANL ground motion assessment, there are relatively simple adjustments that can made to the PFDHA so that a conservative estimate can be made for the BSL-3 structure.

42 ENGINEERING↗

A Fault-oblivious Extreme-scale Execution Environment

Exascale computing systems will provide a thousand-fold increase in parallelism and a proportional increase in failure rate relative to today's machines. Systems software for exascale machines must provide the infrastructure to support existing applications while simultaneously enabling efficient execution of new programming models that naturally express dynamic, adaptive, irregular computation; coupled simulations; and massive data analysis in a highly unreliable hardware environment with billions of threads of execution. We propose a new approach to the data and work distribution model provided by system software based on the unifying formalism of an abstract file system. The proposed hierarchical data model provides simple, familiar visibility and access to data structures through the file system hierarchy, while providing fault tolerance through selective redundancy. The hierarchical task model features work queues whose form and organization are represented as file system objects. Data and work are both first class entities. By exposing the relationships between data and work to the runtime system, information is available to optimize execution time and provide fault tolerance. The data distribution scheme provides replication (where desirable and possible) for fault tolerance and efficiency, and it is hierarchical to make it possible to take advantage of locality. The user, tools, and applications, including legacy applications, can interface with the data, work queues, and one another through the abstract file model. This runtime environment will provide multiple interfaces to support traditional Message Passing Interface applications, languages developed under DARPA's High Productivity Computing Systems program, as well as other, experimental programming models. We will validate our runtime system with pilot codes on existing platforms and will use simulation to validate for exascale-class platforms. In this final report, we summarize research results from the work done at the Ohio State University towards the larger goals of the project listed above.

97 MATHEMATICS AND COMPUTING↗

Structural Health and Prognostics Management for Offshore Wind Turbines: Sensitivity Analysis of Rotor Fault and Blade Damage with O&M Cost Modeling

Operations and maintenance costs for offshore wind plants are significantly higher than the current costs for land-based (onshore) wind plants. One way to reduce these costs would be to implement a structural health and prognostic management (SHPM) system as part of a condition based maintenance paradigm with smart load management and utilize a state-based cost model to assess the economics associated with use of the SHPM system. To facilitate the development of such a system a multi-scale modeling and simulation approach developed in prior work is used to identify how the underlying physics of the system are affected by the presence of damage and faults, and how these changes manifest themselves in the operational response of a full turbine. This methodology was used to investigate two case studies: (1) the effects of rotor imbalance due to pitch error (aerodynamic imbalance) and mass imbalance and (2) disbond of the shear web; both on a 5-MW offshore wind turbine in the present report. Sensitivity analyses were carried out for the detection strategies of rotor imbalance and shear web disbond developed in prior work by evaluating the robustness of key measurement parameters in the presence of varying wind speeds, horizontal shear, and turbulence. Detection strategies were refined for these fault mechanisms and probabilities of detection were calculated. For all three fault mechanisms, the probability of detection was 96% or higher for the optimized wind speed ranges of the laminar, 30% horizontal shear, and 60% horizontal shear wind profiles. The revised cost model provided insight into the estimated savings in operations and maintenance costs as they relate to the characteristics of the SHPM system. The integration of the health monitoring information and O&M cost versus damage/fault severity information provides the initial steps to identify processes to reduce operations and maintenance costs for an offshore wind farm while increasing turbine availability, revenue, and overall profit.

17 WIND ENERGY↗

Final Project Report: Imaging Fault Zones Using a Novel Elastic Reverse-Time Migration Imaging Technique

Imaging fault zones and fractures is crucial for geothermal operators, providing important information for reservoir evaluation and management strategies. However, there are no existing techniques available for directly and clearly imaging fault zones, particularly for steeply dipping faults and fracture zones. In this project, we developed novel acoustic- and elastic-waveform inversion methods for high-resolution velocity model building. In addition, we developed acoustic and elastic reverse-time migration methods for high-resolution subsurface imaging of complex subsurface structures and steeply-dipping fault/fracture zones. We first evaluated and verified the improved capabilities of our newly developed seismic inversion and migration imaging methods using synthetic seismic data. Our numerical tests verified that our new methods directly image subsurface fracture/fault zones using surface seismic reflection data. We then applied our novel seismic inversion and migration imaging methods to a field 3D surface seismic dataset acquired at the Soda Lake geothermal field using Vibroseis sources. Our migration images of the Soda Lake geothermal field obtained using our seismic inversion and migration imaging algorithms revealed several possible fault/fracture zones. AltaRock Energy, Inc. is working with Cyrq Energy, Inc. to refine the geologic interpretation at the Soda Lake geothermal field. Trenton Cladouhos, Senior Vice President R&D of AltaRock, was very interested in our imaging results of 3D surface seismic data from the Soda Lake geothermal field. He planed to perform detailed interpretation of our images in collaboration with James Faulds and Holly McLachlan of University of Nevada at Reno. Using our high-resolution seismic inversion and migration imaging results can help determine the optimal locations to drill wells for geothermal energy production and reduce the risk of geothermal exploration.

47 OTHER INSTRUMENTATION↗

Investigating the Influence of Regional Stress on Fault and Fracture Permeability at Pahute Mesa, Nevada National Security Site

Regional stress may exert considerable control on the permeability and hydraulic function (i.e., barrier to and/or conduit for fluid flow) of faults and fractures at Pahute Mesa, Nevada National Security Site (NNSS). In-situ measurements of the stress field are sparse in this area, and short period earthquake focal mechanisms are used to delineate principal horizontal stress orientations. Stress field inversion solutions to earthquake focal mechanisms indicate that Pahute Mesa is located within a transtensional faulting regime, represented by oblique slip on steeply dipping normal fault structures, with maximum horizontal stress ranging from N29°E to N63°E and average of N42°E. Average horizontal stress directions are in general agreement with large diameter borehole breakouts from Pahute Mesa analyzed in this study and with stress measurements from other locations on the NNSS.

54 ENVIRONMENTAL SCIENCES↗

Design, Test and Demonstration of Fault Current Limiting HTS Transformer

The project developed new technology that enables the creation of a high temperature superconductor-based FCL power transformer. SuperPower’s research and development created new methods to bond HTS conductor to a supporting substrate, test, and insulate the resulting bonded conductor, reduce winding ac losses, ensure FCL functionality during a transformer fault and build firm superconducting joints in the transformer harnesses and cabling. The bonded conductor in this program was shown to meet the critical operating parameters of providing the superconducting transformer operation while being able to meet the target normal state resistance required for FCL operation. The bonded conductor was also shown to be able to handle the fabrication stresses associated with the manufacture of the FCL transformer while also being able to handle the high hoop stresses and axial forces during a fault transient. Much of the technology developed here is applicable to the broader applied superconductivity community. The ability to tailor the clad conductors performance characteristics gives the designer of devices utilizing HTS a broader capability to address the particular needs of an given application. SuperPower worked with its sub-recipients Waukesha Electric Systems, ORNL, Southern California Edison and University of Houston to develop the design, fabrication, installation and operational aspects of a fault current limiting transformer on the electrical grid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Specification of Fenix MPI Fault Tolerance library (V.0.9)

Fenix is a software library compatible with the Message Passing Interface (MPI) to support fault recovery without application shutdown. This specification is derived from a current implementation of Fenix that employs the User Level Fault Mitigation (ULFM) MPI fault tolerance module proposal. We only present the C library interface for Fenix; the Fortran interface will be added once the C version is complete.

97 MATHEMATICS AND COMPUTING↗

Using Current Data to Detect Hardware Faults at Solar Plants

Monitoring amperage data is an effective means of detecting faults in PV plant data. Utilizing amperage data collected at the combiner box gives plant operators an up-to-date list of faulted equipment, allowing them to coordinate maintenance needs at much shorter intervals than previously. Shorter maintenance intervals will increase PV plant production levels, narrowing the gap between expected and actual PV plant performance. The amperage monitoring method performs at a high level, with a string-outage related fault detection True Positive Rate of 46% and False Positive Rate of 8%.

14 SOLAR ENERGY↗

Impact of K-factor on Short Circuit Program Convergence for Inverter-Based Resources during Faults

Classical short-circuit programs that linearize the power network are no longer applicable for inverter based resources (IBRs), necessitating an iterative approach. Phasor domain programs can model the IBRs using an iterative approach considering nonlinear fault responses. In phasor domain models, the IBR can be modeled as a voltage controlled current source (VCCS) in tabular form with positive, negative, and zero sequence information for balanced and unbalance short-circuit faults. In the VCCS modeling of the IBR, positive and negative incremental reactive current, also known as the k-factor, plays an important role in short circuit program convergence. In this work, a few approaches: conventional VCCS modeling with a k-factor of 2, conventional VCCS modeling with a k-factor of 2 with modified pre-fault voltages, VCCS characteristics based on the power flow solution with a k-factor of 2, and VCCS characteristics based on the power flow solution with a k-factor of 1 are investigated for short circuit program convergence under higher IBR penetration. The IEEE 39 bus New England Test System is taken as the test system, and simulations are carried out in PSS®CAPE 15.0.26 simulation software. Simulation results demonstrate that IBR penetration is higher for the VCCS model, which corresponds to the power flow solution with k-factor 1, compared to other approaches.

42 ENGINEERING↗

Undulator Hall Air Temperature Fault Scenarios

Recent experience indicates that the LCLS undulator segments must not, at any time following tuning, be allowed to change temperature by more than about {+-}2.5 C or the magnetic center will irreversibly shift outside of acceptable tolerances. This vulnerability raises a concern that under fault conditions the ambient temperature in the Undulator Hall might go outside of the safe range and potentially could require removal and retuning of all the segments. In this note we estimate changes that can be expected in the Undulator Hall air temperature for three fault scenarios: (1) System-wide power failure; (2) Heating Ventilation and Air Conditioning (HVAC) system shutdown; and (3) HVAC system temperature regulation fault. We find that for either a system-wide power failure or an HVAC system shutdown (with the technical equipment left on), the short-term temperature changes of the air would be modest due to the ability of the walls and floor to act as a heat ballast. No action would be needed to protect the undulator system in the event of a system-wide power failure. Some action to adjust the heat balance, in the case of the HVAC power failure with the equipment left on, might be desirable but is not required. On the other hand, a temperature regulation failure of the HVAC system can quickly cause large excursions in air temperature and prompt action would be required to avoid damage to the undulator system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transfer Learning for HVAC System Fault Detection

Faults in HVAC systems degrade thermal comfort and energy efficiency in buildings and have received significant attention from the research community, with data driven methods gaining in popularity. Yet the lack of labeled data, such as normal versus faulty operational status, has slowed the application of machine learning to HVAC systems. In addition, for any particular building, there may be an insufficient number of observed faults over a reasonable amount of time for training. To overcome these challenges, we present a transfer methodology for a novel Bayesian classifier designed to distinguish between normal operations and faulty operations. The key is to train this classifier on a building with a large amount of sensor and fault data (for example, via simulation or standard test data) then transfer the classifier to a new building using a small amount of normal operations data from the new building. We demonstrate a proof-of-concept for transferring a classifier between architecturally similar buildings in different climates and show few samples are required to maintain classification precision and recall.

transfer learning, Building HVAC, Bayesian framewo↗

Embedded, Real-Time, and Distributed Traveling Wave Fault Location Method Using Graph Convolutional Neural Networks

This work proposes and develops an implementation of a fault location method to provide a fast and resilient protection scheme for power distribution systems. The method analyzes the transient dynamics of traveling waves (TWs) to generate features using the discrete wavelet transform (DWT), which are then used to train several graph convolutional network (GCN) models. Faults are simulated in the IEEE 34-node system, which is divided into three protection zones (PZs). The goal is to identify the PZ in which the fault occurs. The GCN models create a distributed protection scheme, as all nodes are able to retrieve a prediction. Given that message-passing between nodes occurs both during training and in the execution of the model, the resiliency of such schemes to communication losses was analyzed and demonstrated. One of the models, which only uses voltage measurements, was implemented on a Texas Instruments F28379D development board. The execution times were monitored to assess the speed of the protection scheme. It is shown that the proposed method can be executed in approximately a millisecond, which is comparable to existing TW protection in the transmission system. For experimental purposes, a DWT-based detection method is employed. A design of a setup to playback TWs using two development boards is also addressed.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Reliability computation using fault tree analysis

A method is presented for calculating event probabilities from an arbitrary fault tree. The method includes an analytical derivation of the system equation and is not a simulation program. The method can handle systems that incorporate standby redundancy and it uses conditional probabilities for computing fault trees where the same basic failure appears in more than one fault path.

Chelson, P. O.↗

Low-cost coding techniques for digital fault diagnosis

Published report discusses fault location properties of arithmetic codes. Criterion for effectiveness of given code is detection probability of local fault by application of checking algorithm to results of entire set of algorithms of processor. Report also presents analysis of arithmetic codes with low-cost check algorithm which possesses partial fault-location properties.

Avizienis, A. A.↗

Remote sensing reconnaissance of faulting in alluvium, Lake Mead to Lake Havasu, California, Nevada and Arizona. An application of ERTS-1 satellite imagery

The author has identified the following significant results. Analysis of ERTS-1 MSS and other imagery for a 125 x 25 mile area in the southern part of the Basin-Range Province of southeastern California, southern Nevada, and northwestern Arizona indicates the presence of numerous color and contrast anomalies in alluvium. Field work guided by high altitude U-2 and side-looking aerial radar imagery confirmed that these anomalies are fault zones, many of which are believed to be of recent age. Few faults in alluvium have been reported from previous ground based geologic studies in the area. ERTS-1 imagery provides a synoptic perspective previously unavailable for regional geologic studies. The ability to conduct rapid and inexpensive reconnaissance of recent faulting has important applications to land use planning, ground water exploration, geologic hazards, and the siting and design of engineering projects.

Bechtold, I. C.↗