Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

2020 System Optimization Awardee: Carter Wind Turbines

With support from the Competitiveness Improvement Project's System Optimization Award, Carter Wind Energy aims to lower the cost of distributed wind technology and expand deployment. To do so, the company will improve the cost-effectiveness and reliability of midsize wind turbines for remote, off-grid power applications, creating new wind energy deployment opportunities worldwide. This fact sheet provides an overview of Carter Wind Energy's project, how the company will achieve the goals of the award, and how the project fits within the overall Competitiveness Improvement Project.

CIP↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

A review of thermal physics and management inside lithium-ion batteries for high energy density and fast charging

Traditionally it has been assumed that battery thermal management systems should be designed to maintain the battery temperature around room temperature. That is not always true as lithium-ion battery (LIB) R&D is pivoting towards the development of high energy density and fast charging batteries. Therefore, it is necessary to have a comprehensive review of thermal considerations for LIBs targeted for high energy density and fast charging, i.e., the optimal thermal condition, thermal physics (heat transport and generation) inside the battery, and thermal management strategies. As the energy density and charge rate increases, the optimal battery temperature can shift to be higher than room temperature. In the first part of the review various sources of heat generation inside LIBs and various approaches to minimizing battery heat generation are summarized. The importance of heat of mixing due to ion diffusion during fast charging is also highlighted. To improve the temperature uniformity and avoid excessive internal temperature rise, heat transfer inside the battery needs to be enhanced, and reducing the thermal contact resistance between the electrodes and separator can significantly increase the effective thermal conductivity of batteries. In the second part of the review various challenges and latest developments related to thermal transport and properties of LIBs are discussed. Finally, a summary of latest advancement on smart control of internal temperature of LIBs is discussed as depending on the ambient temperature and the optimal temperature; the battery heat needs to be retained or dissipated to elevate or avoid temperature rise.

25 ENERGY STORAGE↗

Asymmetric Dual-Grating Dielectric Laser Accelerator Optimization

Although hundreds of keV in energy gain have already been demonstrated in dielectric laser accelerators (DLAs), the challenge of creating structures that can confine electrons for multiple millimeters remains. We focus here on dual gratings with single-sided drive, which have experimentally demonstrated energy modulation numerous times. Using a Finite-Difference Time-Domain simulation to find the fields within various DLA structures and correlating these results with particle tracking simulation, we look at the impact of teeth height and width, as well as gap and offset, on the performance of these structures. We find a tradeoff between electron throughput and acceleration; however, we also find that for any given grating geometry, there is a gap and offset that will allow some charge acceleration. For our 780 nm laser wavelength, this results in a 1200 nm optimal gap size for most gratings.

Crisp, Sophie (ORCID:0000000327503727)↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗

Techno-Economic Implications of Electrical Machine Scaling for Wave Energy Converters: Preprint

The sizing of an electrical machine for a Wave Energy Converter (WEC) can have a substantial impact on the overall sizing, cost, and rating of the device. An electrical generator is typically part of the power take-off (PTO) system, which is the mechanism by which the energy absorbed by the prime mover is transformed into useable electrical. For practically all WECs, the rate of change of actuation is predominantly determined by the wave resource (i.e., the wave height and frequency) and devices will see a sinusoidally varying velocity according to the wave conditions. The same can then be said for both directly and indirectly coupled PTOs with electrical generators. This techno-economic study investigates electrical machine scaling and associated cost implications through core machine design theory, manufacturer data, supporting literature, and the DOE sponsored Reference Model Project (RMP). The RMP was a partnered effort to develop open-source marine energy (ME) point designs as reference models (RMs) to benchmark ME technology performance and costs, methods for design and analysis of ME technologies, estimations for capital costs, operational costs, and levelized costs of energy (LCOE). The results from this study show torque is directly related to (1) the physical size of the machine required to increase the airgap sheer stresses, (2) the amount of active material, (3) the support structure, (4) bearing size and rating, and (5) offshore cable rating, all of which have a significant effect on overall system costs in terms of both CAPEX and OPEX. This paper aims to be a critical benchmark in helping determine an “optimal” nameplate rating for wave energy devices and their associated PTO. With an optimized rating and sizing process, WEC costs can be reduced, and overall performance can be improved.

cables↗

Efficient wind farm layout optimization with the FLOWERS AEP model and analytic gradients

Wind farm layout optimization (WFLO) studies often aim to maximize the annual energy production (AEP) of a wind farm by choosing an arrangement of turbines that minimizes wake interactions. One way to reduce the cost of WFLO studies is by using more computationally efficient AEP models. The cost of standard AEP modeling approaches, based on the numerical integration of low-fidelity engineering wake models, scales poorly with the number of simulated discrete wind conditions. A second way to reduce cost when using a gradient-based algorithm is to supply exact gradient information instead of finite-difference estimates. However, analytical functions for the derivatives of AEP with respect to turbine positions are not always available in the conventional modeling approach. FLOWERS is a computationally inexpensive, analytical model for wind farm AEP that is specifically developed for WFLO applications. In this paper, we analyze the performance of the FLOWERS AEP model with analytic gradients in a layout optimization study compared with a reference optimization framework across three wind farm case studies. We find that the FLOWERS-based approach reduces computation time by a factor of 50–4000 and improves optimal AEP by about 0.3% with less than half of the variability in AEP across instances with randomized initial conditions. We also find the optimal layouts to be insensitive to model parameter tuning, making FLOWERS-based layout optimization a streamlined, user-friendly approach.

17 WIND ENERGY↗

A MEMS dynamic mechanical analyzer for in situ viscoelastic characterization of 3D printed nanostructures

Cellular metamaterial structures with sub-micron features have shown the ability to become excellent energy absorbing materials for impact mitigation due to the enhanced mechanical properties of materials at the nanoscale. However, in order to optimize the design of these energy absorbing metamaterial structures we need to be able to measure the dynamic properties of the sub-micron features such as storage and loss moduli and the loss factor. Therefore, at scale testing is required to capture the scale, temperature, and strain rate dependent material properties of these nanoscale materials. This study presents the design, fabrication, and calibration of a MEMS-based dynamic mechanical analyzer (DMA) that can be directly integrated with the two photon lithography (TPL) process commonly used to fabricate metamaterial structures with nanoscale features. The MEMS-based DMA consists of a chevron style thermal actuator used to generate a tensile load on the structure and two differential capacitive sensors on each side of the structure used to measure load and displacement. This design demonstrated 1.5 ± 0.75 nm displacement resolution and 104 ± 52 nN load resolution, respectively. Dynamic mechanical analysis was successfully conducted on a single nanowire feature printed between the load and displacement stages of the MEMS device with testing frequencies ranging between 0.01–10 Hz and testing temperatures ranging between 22 °C–47 °C. These initial tests on an exemplar TPL part demonstrate that the printed nanowire behaves as a viscoelastic material wherein the transition from glassy to viscous behavior has already set in at the room temperature.

42 ENGINEERING↗

National Marine Renewable Energy Center Upgrades - LUPA

The data provided is part of a power take off damping optimization study. The power take off damping coefficient was swept from 0 to approximately 7000 N/m/s during a single regular wave test with a real time control of the motor/generator. The generated power from the LUPA (Lab Upgrade Point Absorber) wave energy converter is reported by the motor drive in watts. The csv files in this submission are the corresponding raw time series outputs for each mode of operation of LUPA (one body heave only, two body heave only, and two body six degrees of freedom). Data comes from testing in the Large WaveFlume (LWF) at the O.H. Hinsdale Wave Research Laboratory in Corvallis, OR.

16 TIDAL AND WAVE POWER↗

Data-Driven Generic Turbines for Distributed Wind Modeling, Optimization, and Economic Studies

As distributed energy resources (DER) become less expensive and more popular, utilities, project developers, and customers have an increasing need to model the performance of existing and proposed DER systems. Distributed wind has been shown to have widespread economic potential but is often represented by a simplified model in - or excluded from - DER modeling tools and studies. There is often no economic imperative to extend models and studies to give full consideration to distributed wind. We present a set of data-driven generic turbines derived from 16 years of annual distributed wind market survey data. The proposed methodology can be used to derive generic turbines from separate or updated data sets. Finally, a mixed-integer linear programming approach to optimal distributed wind project sizing is used to demonstrate the generic turbine models. Combined, these models and methods can reduce barriers to considering distributed wind in modeling tools and studies.

Reiman, Andrew P.↗

Integrated Heat Exchanger/Thermal Energy Storage System for CSP Plants

The research and development during the project focused on the design and optimization of an integrated heat exchanger/thermal energy storage (HX/TES) system, the charging and discharging performance of the developed HX/TES system, and the experimental investigation of lab-scale prototypes based on the full-scale system.

42 ENGINEERING↗

Scalable Transmission Expansion Under Uncertainty Using Three-Stage Stochastic Optimization

The intermittent nature of renewable energy poses new challenges for power grids due to its variable and uncertain power output. These features of renewable generation are becoming more relevant to transmission planning as grids reach higher penetration levels of renewable energy. In this paper we present an approach for transmission planning based on scalable computational approaches which enable the explicit consideration of operational uncertainties in the planning process. Using three-stage stochastic programming and the progressive hedging algorithm, we compute transmission expansion decisions on a modified RTS-GMLC test system. We augment the grid with large amounts of wind generation and consider many operational scenarios subject to wind uncertainty.

multi-stage stochastic optimization↗

STREAM: A technology planning and capacity expansion model for the industrial sector

The Strategic Technology Roadmapping and Energy, Environmental, and Economic Analysis Model—STREAM—is an optimization-based modeling tool and analysis framework to assist with strategic planning and technology investments of the industrial sector. This open-source framework is written in Julia using the JuMP package, which enables users to model future “pathways” for incumbent and future production technologies, costs, fuels and energy carriers, and energy and non-energy environmental impacts from industries as they transform in pursuit of a robust and competitive manufacturing sector. The model starts with an initial stock of industrial production technologies and assets at a facility level and then determines pathways that minimize cost, subject to an array of possible constraints on demand, market shares, environmental flows, and other exogenously specified operational considerations such as capacity utilization rates or regional energy costs. Key features of the framework include flexibility to model a wide range of industries and industrial technologies/processes at varying levels of granularity, ability to perform parametric sensitivity analyses, and ability to visualize model results using visualization objects.

capacity expansion↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Topology Optimization of Curved Electrodes with Suggested Simplified Corrugated Designs

The demand for space-efficient energy storage, from grid to device scale, has soared with the rapid electrification of society. To increase energy density while maintaining high rate performance, shaping electrodes has been shown to be an effective strategy. Computational optimization can suggest designs that improve energy storage performance; however, generated designs are often complex, leading to manufacturing challenges. Additionally, most optimization is typically conducted in standard rectangular domains, whereas some applications, such as in the aerospace industry or in consumer electronics, may benefit from optimized electrodes that fit in a nonstandard form factor. Here, in this work, we use topology optimization to design capacitive full-cell electrodes in a curved domain. We propose a simplified corrugated electrode design based on the optimization results and show that the energy stored in the simplified design is only reduced by about 5–27% when compared to that in the fully optimized design, with more deviation occurring when ionic transport in the porous electrode is particularly impeded. Overall, we find that these simplified designs are promising, particularly given the more conventional manufacturing techniques required, and have a 42–369% increase in energy stored compared to monolithic electrodes.

Energy - Storage↗

Discrete versus continuous: Enhancing battery optimization in capacity expansion models

This study compares two battery modeling approaches for capacity expansion models: discrete-duration and continuous-duration formulations. In the discrete approach, battery duration is fixed, and power capacity is optimized. In the continuous approach, both power and energy capacities are decision variables, allowing storage duration to be optimized endogenously. Although both discrete-duration and continuous-duration battery formulations are used in long-term power system planning models, the literature has provided limited direct, systematic comparisons of their implications within a common modeling framework. To address this gap, this study implements both approaches in the Regional Energy Deployment System (ReEDS TM ) capacity expansion model using two resource adequacy methods, across a range of future system conditions, and with varying battery cost projections. Results show continuous-duration and high-resolution discrete approaches produce similar capacity expansion outcomes. The continuous formulation achieves faster runtimes compared to discrete-duration runs with many discrete-duration options. However, the discrete-duration approach allows users to choose to have limited fidelity for storage duration options, which in some cases can outperform the continuous formulation. The continuous formulation has the lowest overall system costs, indicating its ability to fine-tune storage duration to better meet specific system needs. This study's findings provide a side-by-side evaluation of discrete and continuous battery modeling approaches and offer guidance for improving the representation of real-world systems, flexibility, and computational efficiency for representing energy storage in long-term power system planning models.

25 ENERGY STORAGE↗