Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “energy efficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Improving Compressed Air Energy Efficiency in Automotive Plants - Practical Examples and Implementation

The automotive industry is the largest industry in the United States in terms of the dollar value of production [1]. U.S. automakers face tremendous pressure from foreign competitors, which have an increasing manufacturing presence in this country. The Big Three North American Original Equipment Manufacturers (OEMs) General Motors, Ford, and Chrysler are reacting to declining sales figures and economic strain by working more efficiently and seeking out opportunities to reduce production costs without negatively affecting the production volume or the quality of the product. Successful, cost-effective investment and implementation of the energy efficiency technologies and practices meet the challenge of maintaining the output of high quality product with reduced production costs. Automotive stamping and assembly plants are typically large users of compressed air with annual compressed air utility bills in the range of $2M per year per plant. This paper focuses on practical methods that the authors have researched, analyzed and implemented to improve compressed air system efficiency in automobile manufacturing facilities. It describes typical compressed air systems in automotive stamping and assembly plants, and compares these systems to best practices. The paper then presents a series of examples, organized using the method of inside-out approach, which strategically identifies the energy savings in the compressed air system by first minimizing end-use demand, then minimizing distribution losses, and finally making improvements to primary energy conversion equipment, the air compressor plant.

Implementation of Compressed Air Reduction Project↗

Energy Efficiency Assistance for Galena Alaska

The City of Galena sits along the north bank of the Yukon River with no road access. Temperatures regularly reach negative 20°F in the winter and sunlight extends for up to 21 hours a day in the summer. Galena’s 400 residents, including members of the Koyukuk Athabascan culture, primarily use fuel oil and locally forested wood for heating and electricity generation. Because these resources are costly to obtain, local households have a high energy burden, spending 7% of their annual income on energy (averaging $4,000 per year). To reduce this burden, the City of Galena joined the U.S. Department of Energy’s (DOE) Remote Alaska Community Energy Efficiency (RACEE) Competition, where they received financial and technical assistance to implement energy savings solutions across their community, including building envelope improvements, solar panels, and LED lighting. Additionally, Galena installed new energy monitoring equipment to continue measuring the impacts of this work beyond the RACEE project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carbon Nanotube Membranes for Energy Efficient Carbon Sequestration (CRADA Final Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Porifera, Inc. to develop Carbon Nanotube Membranes for Energy-Efficient Carbon Sequestration. Porifera, Inc. was a recently founded start-up company whose sole mission is to bring the carbon nanotube-based technology for effective membrane separations to the marketplace. This CRADA project resulted from an ARPA-E award received by Porifera (ARPA-E Co-Operative Agreement number DE AR 0000025), in which LLNS was identified as a proposed subcontractor with valuable experience, skill and ability which made LLNS uniquely positioned to perform the research for this project.

Fornasiero, Francesco↗

Energy efficient engine: Turbine intermediate case and low-pressure turbine component test hardware detailed design report

A four stage, low pressure turbine component has been designed to power the fan and low pressure compressor system in the Energy Efficient Engine. Designs for a turbine intermediate case and an exit guide vane assembly also have been established. The components incorporate numerous technology features to enhance efficiency, durability, and performance retention. These designs reflect a positive step towards improving engine fuel efficiency on a component level. The aerodynamic and thermal/mechanical designs of the intermediate case and low pressure turbine components are presented and described. An overview of the predicted performance of the various component designs is given.

Leach, K.↗

Energy-efficient carbon capture from industrial point sources via commercially available green solvent and hollow fiber membrane contactors

Solvent-based absorption systems have emerged in the carbon capture space due to their high absorption capacities, reusability, and favorable energy requirements. Using diethyl sebacate as a solvent for pre- and post-combustion carbon capture has advantages over other solvents, including high hydrophobicity, low viscosity, low vapor pressure, high CO 2 solubility, high CO 2 selectivity, and being commercially available in large quantities. Despite these advantageous properties, the use of diethyl sebacate as a solvent for post-combustion carbon capture has not been studied in detail. To examine the capability of diethyl sebacate, a scalable, energy-efficient, hollow fiber membrane (microporous polypropylene and polyvinylidene fluoride) contactor (HFMC)-based process with low-cost and high surface area is investigated. A purity of 95.3 % CO 2 with 46 % recovery in one absorption stage was achieved, with a permeate flux over one magnitude greater than using a deep eutectic solvent in the same system. Technoeconomic analysis determined a ∼ 0.8 GJ per ton of CO 2 at a processing cost of ∼$93 per ton of CO 2 . Results from this work underscore the potential for utilizing green solvents in HFMC-based separation processes for effective carbon capture and provide a pathway towards practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward Energy-Efficient HPC: Insights from Power Profiling a Cloud-Resolving Earth System Model

Power is a fundamental constraint as supercomputing advances to exascale. Efficient operation within strict power budgets requires application-aware power management based on a detailed understanding of application-level power behavior. This work analyzes the Energy Exascale Earth System Model (E3SM) atmosphere component, SCREAM, on Perlmutter (NERSC) and Frontier (OLCF). We characterize power variation across inputs, concurrency levels, and power caps, evaluate the energy impact of code optimizations, and attribute energy within the code using a newly developed GPU energy model. Results show that SCREAM’s peak power remains stable during its core execution phase and decreases gradually as concurrency increases. Power capping experiments reveal a performance–energy "sweet spot". On Perlmutter, limiting GPU power to 50% of thermal design power (TDP) achieves up to 15% energy savings with a 7% performance penalty. On Frontier, a 40% TDP cap yields up to 10% energy savings with less than 10% performance loss. Code optimizations reduce SCREAM energy by shortening run time without increasing power. Modeling reveals a critical insight: data movement accounts for approximately 70% of SCREAM’s GPU energy. This fundamentally shifts the optimization focus from FLOPS to data transfer reduction for this class of applications, offering the most impactful strategy for improving energy efficiency. This work establishes a foundation for practical, application-aware power management at exascale.

Zhao, Zhengji [Lawrence Berkeley National Laborato↗

Costs and benefits of energy efficiency improvements in ceiling fans

Ceiling fans contribute significantly to residential electricity consumption, especially in developing countries with warm climates. The paper provides analysis of costs and benefits of several options to improve the efficiency of ceiling fans to assess the global potential for electricity savings and green house gas (GHG) emission reductions. Ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terawatt hours per year could be saved and 25 million metric tons of carbon dioxide equivalent (CO2-e) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize potential savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient supercritical water desalination using a high-temperature heat pump: A zero liquid discharge desalination

Supercritical water desalination (SCWD) is zero liquid discharge technology that can potentially control the solubility of different electrolytes. However, SCWD is an energy-intensive process and requires high-quality thermal heat (> 450 °C). This study proposes the integration of a high-temperature heat pump to reduce the SCWD energy requirement. The integrated system energy consumption improves by 36% for 3.5% feed concentration and 14% for 20% feed, and the distillate cost reduces by 15% and 10%. Another benefit of the proposed integration is the system can be operated using only electricity as a heat source, as is the case with commonly used high-recovery thermal desalination technology. The integrated SCWD-heat pump system shows superior performance compared to the commercially used brine concentrator and crystallizer system. It is approximately 20% more energy-efficient for 25% feed concentration and 8% cheaper. Hence, the integrated SCWD-heat pump has the potential to outperform the pre-existing high-recovery desalination technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy efficient photonic memory based on electrically programmable embedded III-V/Si memristors: switches and filters

Abstract Over the past few years, extensive work on optical neural networks has been investigated in hopes of achieving orders of magnitude improvement in energy efficiency and compute density via all-optical matrix-vector multiplication. However, these solutions are limited by a lack of high-speed power power-efficient phase tuners, on-chip non-volatile memory, and a proper material platform that can heterogeneously integrate all the necessary components needed onto a single chip. We address these issues by demonstrating embedded multi-layer HfO 2 /Al 2 O 3 memristors with III-V/Si photonics which facilitate non-volatile optical functionality for a variety of devices such as Mach-Zehnder Interferometers, and (de-)interleaver filters. The Mach-Zehnder optical memristor exhibits non-volatile optical phase shifts > π with ~33 dB signal extinction while consuming 0 electrical power consumption. We demonstrate 6 non-volatile states each capable of 4 Gbps modulation. (De-) interleaver filters were demonstrated to exhibit memristive non-volatile passband transformation with full set/reset states. Time duration tests were performed on all devices and indicated non-volatility up to 24 hours and beyond. We demonstrate non-volatile III-V/Si optical memristors with large electric-field driven phase shifts and reconfigurable filters with true 0 static power consumption. As a result, co-integrated photonic memristors offer a pathway for in-memory optical computing and large-scale non-volatile photonic circuits.

Cheung, Stanley (ORCID:0000000248860013)↗

Energy Efficient Opportunities During Remodeling or Renovation

Residential buildings go through many changes during their useful life, which is defined more by their care and maintenance, than age. Many homes that are a century old are still serviceable and desirable and even older homes that have been abandoned can be renovated. In contrast, many newly built homes are good candidates for energy efficiency retrofit measures before occupancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reversible Methane Electrochemical Reactors as Efficient Energy Storage for Fossil Power

The overall objective of the project was to conduct a comprehensive Research & Development (R&D) program to demonstrate the suitability and future advancement and integration of reversible methane protonic ceramic electrochemical reactors (PCERs) as an efficient Energy Storage System (ESS) with fossil fuel power plants. Fundamental process and system models are developed to conduct a preliminary conceptual study and investigate the power plant system integration requirements, performance requirements, and technical and non-technical gaps for eventual implementation at system level. Technology maturation requirements is also investigated through identifying the critical technical elements and networking with industrial technology developers and end-users.

08 HYDROGEN↗

Integrated energy management study. Energy efficient transport program

The Integrated Energy Management (IEM) Study investigated the practicality and feasibility of a closed-loop energy management system for transport aircraft. The study involved: (1) instrumentation and collection of in-flight data for a United Airlines 727-200 flying 80 revenue flights throughout the United Airlines network,(2) analysis of the in-flight data to select representative city pairs and establish operational procedures employed in flying a reference flight profile, (3) simulation of the reference profile in a fast-time model to verify the model and establish performance values against which to measure IEM benefits, (4) development of IEM algorithms, and (5) assessment of the IEM concept.

Source record↗

Energy Efficient Glass Melting - The Next Generation Melter

The objective of this project is to demonstrate a high intensity glass melter, based on the submerged combustion melting technology. This melter will serve as the melting and homogenization section of a segmented, lower-capital cost, energy-efficient Next Generation Glass Melting System (NGMS). After this project, the melter will be ready to move toward commercial trials for some glasses needing little refining (fiberglass, etc.). For other glasses, a second project Phase or glass industry research is anticipated to develop the fining stage of the NGMS process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficient Engine Flight Propulsion System Preliminary Analysis and Design Report

The final design and analysis of the flight propulsion system is presented. This system is the conceptual study engine defined to meet the performance, economic and environmental goals established for the Energy Efficient Engine Program. The design effort included a final definition of the engine, major components, internal subsystems, and nacelle. Various analytical representations and results from component technology programs are used to verify aerodynamic and structural design concepts and to predict performance. Specific design goals and specifications, reflecting future commercial aircraft propulsion system requirements for the mid-1980's, are detailed by NASA and used as guidelines during engine definition. Information is also included which details salient results from a separate study to define a turbofan propulsion system, known as the maximum efficiency engine, which reoptimized the advanced fuel saving technologies for improved fuel economy and direct operating costs relative to the flight propulsion system.

Bisset, J. W.↗

Workflow Provenance in the Computing Continuum for Responsible, Trustworthy, and Energy-Efficient AI

As Artificial Intelligence (AI) becomes more pervasive in our society, it is crucial to develop, deploy, and assess Responsible and Trustworthy AI (RTAI) models, i.e., those that consider not only accuracy but also other aspects, such as explainability, fairness, and energy efficiency. Workflow provenance data have historically enabled critical capabilities towards RTAI. Provenance data derivation paths contribute to responsible workflows through transparency in tracking artifacts and resource consumption. Provenance data are well-known for their trustworthiness helping explainability, reproducibility, and accountability. However, there are complex challenges to achieve RTAI, which are further complicated by the heterogeneous infrastructure in the computing continuum (Edge-Cloud-HPC) used to develop and deploy models. As a result, a significant research and development gap remains between workflow provenance data management and RTAI. In this paper, we present a vision of the pivotal role of workflow provenance in supporting RTAI and discuss related challenges. We present a schematic view between RTAI and provenance, and highlight open research directions.

Santos Souza, Renan↗