Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffractive optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗

Generation regimes of an Nd : YAG laser with mode locking by a travelling-wave acousto-optic modulator and spherical mirror

The lasing regimes of a diode-pumped Nd : YAG laser with mode locking by a spherical mirror and a travelling-wave acousto-optic modulator (SMAOM method) are investigated. The lasing dynamics at mode spacing detuning from the doubled operating modulator frequency and with a change in the diffraction modulator efficiency is studied. The results of measuring the pulse duration and the frequency spectrum of output radiation are presented. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous refraction of light through slanted-nanoaperture arrays on metal surface

We report a nanoapertured metal surface that demonstrates anomalous refraction of light for a wide range of incident angles. A nanoslit aperture is designed to serve as a tilted vertical-dipole whose radiation pattern orients to a glancing angle direction to substrate. An array of such slanted nanoslits formed in a metal film redirects an incident beam into the direction of negative refraction angle: the aperture-transmitted wave makes a far-field propagation to the tilt-oriented direction of radiation pattern. The thus-designed nanoaperture array demonstrates the −1st order diffraction (i.e., to the negative refraction-angle direction) with well-suppressed background transmission (the zero-order direct transmission and other higher-order diffractions). Engineering the radiation pattern of nanoaperture offers an approach to overcoming the limits of conventional diffractive/refractive optics and complementing metasurface-based nano-optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physical and chemical characterization techniques for metallic powders

Systematic studies have been carried out on two different powder materials used for additive manufacturing: stainless steel and cobalt-chrome. An extensive array of characterization techniques were applied to these two powders. The physical techniques included laser-diffraction particle-size analysis, X-ray computed tomography for size and shape analysis, and optical and scanning electron microscopy. Techniques sensitive to chemistry included X-ray diffraction and energy-dispersive analytical X-ray analysis. The background of these techniques will be summarized and some typical findings comparing different samples of virgin additive manufacturing powders, taken from the same lot, will be given. The techniques were used to confirm that different samples of powder from the same lot were essentially identical, within the uncertainty of the measurements.

36 MATERIALS SCIENCE↗

Optical-data-processing properties of a liquid-crystal television spatial light modulator

The potential of an extremely inexpensive liquid-crystal television (LCTV) as a two-dimensional spatial light modulator has been investigated. The LCTV modulates the transmission of coherent or incoherent light and can either be electronically addressed through a microcomputer or optically addressed with a TV camera. The transmission characteristics of the device have been measured, its diffraction pattern is examined, and its use as an input device for an optical correlator is tested. It is discovered that, with proper modifications, it has potential for optical-data-processing applications.

Liu, H.-K.↗

Effect of Heat Treatment on Microstructure and Mechanical Properties of Extruded Mg-4Zn-1.5Al-2Sn Alloy

The microstructure and mechanical properties of extruded Mg-4Zn-1.5Al-2Sn (ZAT422) alloy under different heat treatments were investigated by optical microscopy, scanning electron microscopy, x-ray diffraction, transmission electron microscopy, micro-hardness tests, and tensile tests. The results show that the as-extruded and heat-treated ZAT422 alloys mainly consisted of α-Mg and Mg{sub 2}Sn, and no ternary phase was detected. After aging, the amount of secondary phase precipitates increased significantly and the mechanical properties were improved. Among all the heat treatments, T5 heat treatment at 150 °C for 25 h resulted in the best combination of strength and ductility for ZAT422 alloy. The ultimate tensile strength, yield strength, and elongation (ε{sub f}) were found to be 290, 182 MPa, and 20%, respectively. Based on microstructural characterization, the variations in mechanical properties of the alloy subjected to heat treatment were analyzed in detail.

36 MATERIALS SCIENCE↗

On the evolution of secondary hardening carbides during continuous versus isothermal heat treatment of high speed steel HS 6-5-2

The continuous heat treatment of high speed steels reduces the process times from several hours to a few minutes. The resulting cost savings as well as lower decarburisation and distortion make the continuous heat treatment favourable over an isothermal heat treatment. However, the microstructure-property relationship during continuous heat treatments is far from being well understood. In order to identify the key microstructural features for the future optimisation of continuous heat treatments of high speed steels this study compares a current industrial continuous and an isothermal heat treatment of steel HS 6-5-2 by means of light optical microscopy, scanning electron microscopy, X-ray diffraction, atom probe tomography, and red hardness. After continuous hardening the content of primary carbides is higher and the amount of retained austenite is lower compared to isothermal hardening. Due to the reduced time for dissolution of primary carbides a lower content of alloying elements is present in the martensitic matrix for subsequent tempering. Therefore, the chemical composition of the secondary hardening carbides after tempering is different for a continuous heat treatment. Although the difference in chemistry is quite pronounced, the deterioration of the hardness at elevated temperatures, which strongly influences the performance characteristics of the finished parts, is not altered. - Highlights: •We studied the continuous and isothermal heat treatment of the steel HS 6-5-2. •The amount of primary carbides is higher in a continuously heat treated steel. •The chemistry of secondary hardening carbides changes during tempering. •Continuously heat treated steels exhibit the same performance characteristics.

36 MATERIALS SCIENCE↗

Toyota beamline (BL33XU) at SPring-8

The Toyota beamline (BL33XU) at SPring-8 is an undulator beamline developed to assist in the study of various automotive-related materials. The light source is a tapered in-vacuum undulator that provides a variable energy band width as well as a high brilliance X-ray beam. Two different optical arrangements are available: Optics 1 and Optics 2. Optics 1 is dedicated to time-resolved X-ray absorption spectroscopy (XAFS), and consists of two channel-cut crystal monochromators and four water-cooled flat Si mirrors. The Si(111) and Si(220) monochromator crystals cover an energy range of 4.0–46.0 keV and are driven by high-speed AC servo motors. These monochromators, in conjunction with the tapered undulator, enable high-quality XAFS data acquisition with a temporal resolution of 10 ms. Optics 2 is optimized for X-ray diffraction, scattering and imaging and includes a recently installed double crystal monochromator, two water-cooled flat Si mirrors and Kirkpatrick-Baez (KB) focusing mirrors. The monochromator incorporates parallel mounted Si(111) and Si(311) crystals and covers an energy range of 4.5–70 keV. The beamline provides two experimental stations: Exp. Hutch 2 and Exp. Hutch 3. The gas supply system and mass spectrometers installed in Exp. Hutch 2 allow in-operando measurements under various atmospheres. The scanning three-dimensional X-ray diffraction (scanning 3DXRD) microscopy instrumentation developed and installed in Exp. Hutch 3 enables non-destructive orientation and stress mapping of 1 mm-thick steel specimens using a high energy microbeam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamical scattering in coherent hard x-ray nanobeam Bragg diffraction

Unique intensity features arising from dynamical diffraction arise in coherent x-ray nanobeam diffraction patterns of crystals having thicknesses larger than the x-ray extinction depth or exhibiting combinations of nanoscale and mesoscale features. We demonstrate that dynamical scattering effects can be accurately predicted using an optical model combined with the Darwin theory of dynamical x-ray diffraction. The model includes the highly divergent coherent x-ray nanobeams produced by Fresnel zone plate focusing optics and accounts for primary extinction, multiple scattering, and absorption. Furthermore, the simulation accurately reproduces the dynamical scattering features of experimental diffraction patterns acquired from a GaAs/AlGaAs epitaxial heterostructure on a GaAs (001) substrate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crossover Concept for Optical Printed Circuits

It is possible to reduce crosstalk between optical signals in intersecting optical conductors by taking two steps: Minimize amount of light diffracted into wrong conductor by selecting optimum conductor width, and place light traps in each conductor. How well techniques work depends in part on quality of optical conductors (partically surface smoothness) and on how closely optical-signal mode of propagation approaches ideal. Nature of signals also important: With digital signals, less crosstalk attenuation required than for analog signals.

Jamieson, R. S.↗

ATLAST-9.2: A Deployable Large Aperture UVOIR Space Telescope

We present the results of a study of a deployable version of the Advanced Technology Large Aperture Space Telescope (ATLAST) that could be launched on an Evolved Expendable Launch Vehicle (EELV). ATLAST is a concept for a next-generation UVOIR observatory to follow HST and JWST. The observatory retains significant heritage from JWST, thereby taking advantage of technologies and engineering already developed for that mission. At the same time, we have identified several design changes to the JWST architecture, some of which are required due to the demanding wavefront error requirements at visible wavelengths. The optical telescope assembly has a segmented 9.2-meter aperture and consists of 36 hexagonal glass mirrors, each of which is I.3l5m in size (flat-to-flat). The telescope can be folded to fit in the 6.5m fairing on the planned upgrade to the Delta-IV heavy launch vehicle. Near-real time wavefront sensing and control is performed on-board the telescope using stars in the field of view to deliver diffraction limited imaging performance at 500nm wavelength. The optical design of the telescope provides an 8x20 arcmin FOV in which 4-5 instruments can be accommodated, plus fine guidance and wavefront sensors. Unlike JWST, the OTA sits at the end of a multi-gimbaled arm, allowing pitch and roll motion, and is isolated from the sunshield and spacecraft bus by an active isolation system. Our design permits servicing in order to extend the life of the observatory.

Oegerle, William R.↗

Variable magnification variable dispersion glancing incidence imaging x ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carriers each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a multilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x ray sensitive photographic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard↗

Variable magnification variable dispersion glancing incidence imaging x-ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x-ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x-ray and extreme ultraviolet radiation sources includes a pirmary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carries each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a mutlilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x-ray sensitive photogrpahic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard B.↗

Room temperature photoluminescence properties of ZnO nanorods grown by hydrothermal reaction

Zinc oxide (ZnO) nanorods were fabricated by a hydrothermal reaction on silicon (Si) substrate at 95 °C for 6 hours. The ZnO seed layer was fabricated by depositing ZnO thin films on Si substrates by ultrasonic spray pyrolisis (USP). The annealing effects on crystal structure and optical properties of ZnO nanorods were investigated. The post-annealing treatment was performed at 800 °C with different environments. The annealed of ZnO nanorods were characterized by X-ray diffraction (XRD) and photoluminescence (PL) in order to analyze crystal structure and optical properties, respectively. The results show the orientations of [002], [101], [102], and [103] diffraction peaks were observed and hexagonal wurtzite structure of ZnO nanorods were vertically grown on Si substrates. The room temperature PL spectra show ultra-violet (UV) and visible emissions. The annealed of ZnO nanorods in vacuum condition (3.8 × 10{sup −3} Torr) has dominant UV emission. Meanwhile, non-annealed of ZnO nanorods has dominant visible emission. It was expected that the annealed of ZnO in vacuum condition suppresses the existence of native defects in ZnO nanorods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effective shuttling of photoexcitons on CdS/NiO core/shell photocatalysts for enhanced photocatalytic hydrogen production

Highlights: • CdS/NiO leaf-like morphology was prepared by hydrothermal, citrate mediated growth. • CdS/NiO hierarchical catalyst showed improved rate of photocatalytic H{sub 2} generation. • CdS/NiO showed 2 folds higher rate of H{sub 2} production than CdS under visible light irradiation. • Optimized catalyst showed good stability for 30 h of continuous irradiation. - Abstract: Hierarchical structure of NiO immobilized on CdS photocatalyst (CdS/NiO) was synthesized for stable and efficient H{sub 2} production. The catalyst is designed to suppress the photo-corrosion behaviour without affecting catalytic activity of CdS structures having tamarind leaf-like morphology is protected by fabricating thin-layer of NiO. The exterior thin-layer transmits the light into CdS in-turn exciton moved to surface for reaction with adsorbed reactant species. Structural, morphological and optical properties were studied using X-ray diffraction (XRD), ultraviolet-visible light (UV–vis) diffuse reflectance spectra (DRS), high resolution transmission electron microscopy (HR-TEM), X-ray photoelectron spectroscopy (XPS). The results illustrates that synthesized catalyst composed of crystalline CdS/NiO hierarchical structure that absorbs light in the visible spectrum and improved charge carrier separation than CdS or NiO alone. The photocatalytic activity was examined for H{sub 2} generation under visible light irradiation using Xe-lamp as light source. In order to achieve enhanced H{sub 2} production rate amount of NiO loading was optimized and results were found in the following order CdS/NiO > CdS. Under optimal conditions the catalyst showed stable H{sub 2} evolution for 30 h of continuous irradiation. Under optimal conditions catalyst showed visible light to H{sub 2} conversion efficiency of 6.63%.

36 MATERIALS SCIENCE↗

Perfect crystal propagator for physical optics simulations with Synchrotron Radiation Workshop

Until now, a treatment of dynamical diffraction from perfect crystals has been missing in the "Synchrotron Radiation Workshop" (SRW) wavefront propagation computer code despite the widespread use of crystals on X-ray synchrotron beamlines. Now a special propagator" module for calculating dynamical diffraction from a perfect crystal in the Bragg case has been written in C++, integrated into the SRW C/C++ library and made available for simulations using the Python interface of SRW. The propagator performs local processing of the frequency-domain electric field in the angular representation. A 2-D Fast Fourier Transform is used for changing the field representation from/to the coordinate representation before and after applying the crystal propagator. This ensures seamless integration of the new propagator with the existing functionalities of the SRW package, allows compatibility with existing propagators for other optical elements, and enables the simulation of complex beamlines transporting partially coherent X-rays. The code has been benchmarked by comparison with predictions made by plane-wave and spherical-wave dynamical diffraction theory. Test simulations for a selection of X-ray synchrotron beamlines are also shown.

47 OTHER INSTRUMENTATION↗

Fabrication and Study of a Concave Crystal Mirror for the KORTES Project

A method for fabrication of a concave spherical mirror made of crystalline quartz is proposed and X-ray optical properties of the mirror are studied. The radius of curvature is 1630 mm. The shape of the mirror surface is studied using an interferometer with a diffraction reference wave. In the entire processing region, the maximum deviation from the nearest sphere is about 0.2 μm and the rms is 34 nm, so that high quality of imaging is provided with an angular error of about 2″ (angular seconds). Reflection coefficient (about 7%) and lower bound limit of spectral selectivity (λ/δλ ≈ 1775) are determined in the vicinity of a wavelength of λ = 0.834 nm, which is close to the working wavelengths of the MgXII doublet (λ = 0.8418 and 0.8423 nm). Position of the Bragg peak and spectral selectivity remain unchanged upon bending of the crystal mirror within measurement accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗