Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Coded-mask-based wavefront sensing technique for APS nanofocusing beamline diagnostics

Here, we extend our recently developed coded-mask wavefront sensing technique to enable single-shot measurements of nanofocused x-ray beams. This method accurately reconstructs the focal beam profile by backpropagating the wavefront measured downstream of the beam focus. To validate its performance, we benchmarked it against the conventional fluorescence wire scan method, successfully measuring ∼120 nm focal spots at the 28-ID-B beamline of the Advanced Photon Source using a polymeric compound refractive lens. The results highlight the effectiveness of coded-mask wavefront sensing for high-precision beam profiling and its application as a real-time wavefront monitoring tool.

Shi, Xianbo [Argonne National Laboratory (ANL), Ar↗

Using computational singular perturbation as a diagnostic tool in ODE and DAE systems: a case study in heterogeneous catalysis

We have extended the computational singular perturbation (CSP) method to differential algebraic equation (DAE) systems and demonstrated its application in a heterogeneous-catalysis problem. The extended method obtains the CSP basis vectors for DAEs from a reduced Jacobian matrix that takes the algebraic constraints into account. Here we use a canonical problem in heterogeneous catalysis, the transient continuous stirred tank reactor (T-CSTR), for illustration. The T-CSTR problem is modelled fundamentally as an ordinary differential equation (ODE) system, but it can be transformed to a DAE system if one approximates typically fast surface processes using algebraic constraints for the surface species. We demonstrate the application of CSP analysis for both ODE and DAE constructions of a T-CSTR problem, illustrating the dynamical response of the system in each case. We also highlight the utility of the analysis in commenting on the quality of any particular DAE approximation built using the quasi-steady state approximation (QSSA), relative to the ODE reference case.

97 MATHEMATICS AND COMPUTING↗

Grid-Assisted Direct-Current Magnetron Sputtering of Titanium: Plasma Discharge Diagnostics

Grid-assisted magnetron sputtering is attractive for the deposition of ultrathick Be coatings in inertial confinement fusion (ICF) applications because it offers improved control over the plasma. Here, we investigate the plasma discharge characteristics of grid-assisted direct current magnetron sputtering with Ti as a surrogate sputter target material instead of Be. We map the magnetic field of our magnetron source assembly, study the current-voltage characteristics of both the source and the substrate, and measure the energy distributions of ions bombarding the film surface during growth. The results reveal a slightly asymmetric magnetic field of the magnetron source array and strong dependencies of the plasma discharge characteristics on both the grid and the substrate voltages. Positive grid voltage increases both target and substrate currents, increases the plasma potential, and broadens the energy distributions of ions bombarding the substrate. Grid biasing effects on the plasma discharge characteristics and substrate current can be attributed to corresponding changes to the plasma potential, while substrate biasing effects are more complex and nonlinear. Furthermore, these results demonstrate that grid-assisted deposition offers additional flexibility in controlling the deposition process for tuning properties of ultrathick films for ICF applications.

ICF targets↗

Plasma diagnostics and modeling of lithium-containing plasmas

Thin-film deposition from chemically reactive multi-component plasmas is complex, and the lack of electron collision cross-sections for even the most common metalorganic precursors and their fragments complicates their modeling based on fundamental plasma physics. This study focuses on understanding the plasma physics and chemistry in argon (Ar) plasmas containing lithium bis (trimethylsilyl) amide used to deposit Li x Si y thin films. These films are emerging as potential solid electrolytes for lithium-ion batteries, and the Li-to-Si ratio is a crucial parameter to enhance their ionic conductivity. We deposited Li x Si y films in an axial flow-through plasma reactor and studied the factors that determine the variation of the Li-to-Si ratio in films deposited at various points on a substrate spanning the entire reactor axis. While the Li-to-Si ratio is 1:2 in the precursor, the Li-to-Si ratio is as high as 3:1 in films deposited near the plasma entrance and decreases to 1:1 for films deposited downstream. Optical emission from the plasma is dominated by Li emission near the entrance, but Li emission disappears downstream, which we attribute to the complete consumption of the precursor. We hypothesized that the axially decreasing precursor concentration affects the electron energy distribution function in a way that causes different dissociation efficiencies for the production of Li and Si. We used Li line intensities to estimate the local precursor concentration and Ar line ratios to estimate the local reduced electric field to test this hypothesis. This analysis suggests that the mean electron energy increases along the reactor axis with decreasing precursor concentration. As a result, the decreasing Li-to-Si ratio with axially decreasing precursor concentration may be explained by Li release from the precursor having lower threshold energy than Si release.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron density profile and associated fluctuation measurements using a microwave reflectometry diagnostic on Helically Symmetric eXperiment (HSX)

Abstract A dual-band frequency-modulated reflectometry is employed on the Helically Symmetric eXperiment (HSX) stellarator. This system equips a fast PIN switch to alternate the frequency source between two voltage-controlled oscillators, providing an operational frequency range from 14.5 GHz to 25.5 GHz. A monostatic antenna geometry and an ellipsoidal mirror are implemented in the vessel of HSX, where the polarization of the transmitted microwave can be switched between O- and X-mode to accommodate the magnetic field and plasma density. Although the original system was designed for density fluctuation measurement, significant efforts have been undertaken to improve the system performance and to realize the density profile inversion. Recent improvements of the system reported here include calibration of the dispersion in the transmission line, optimization of the waveform, and implementation of the Choi-Williams time–frequency distribution for spectral analysis. In this paper, we present the optimization of the reflectometry system along with first experimental measurements of the density profile and observations of fluctuations during gas puffing experiments.

Han, X. (ORCID:0000000184986433)↗

Time and space resolved diagnostics for plasma thermal-chemical instability of fuel oxidation in nanosecond plasma discharges

Here, an instability in a nanosecond pulsed dielectric barrier discharge plasma occurring in methane–oxygen–argon mixtures is experimentally observed and measured by 1D time-resolved in situ electric field measurements. This instability, which seems to be created by the positive feedback between plasma kinetics and plasma-assisted low temperature fuel oxidation, is studied using electric field induced second harmonic generation and direct ICCD imaging. The rapid formation of streamers from an originally uniform discharge appears to be caused by the chemical kinetics of plasma-assisted low temperature methane oxidation, which may be resulting in a new type of plasma instability: a thermal-chemical instability. The results also revealed that the occurrence of this possible thermal-chemical instability in a reactive flow drastically changes the plasma properties by forming multiple secondary discharges and possibly leads to micron-sized non-uniform electric distributions. Single shot uncalibrated measurements of the electric field of the micron sized streamers appears to show much greater strengths than the average electric field. Furthermore, one-dimensional data analysis shows the positive feedback loop between the streamers and the low temperature plasma assisted oxidation chemistry in the plasma thermal-chemical instability. The present finding advances the understanding plasma instability growth and provides a new way to control plasma uniformity in plasma-assisted combustion and plasma fuel reforming.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visible spectroscopy of highly charged tungsten ions with the JET charge exchange diagnostic

Since the installation of the ITER-like wall on the JET tokamak, visible emission from a broad range of tungsten charge states has complicated plasma ion temperature and toroidal rotation measurements. A plethora of charge exchange transitions, from ions up to W 56+ , and 21 suspected magnetic dipole transitions have been observed. In particular W 39+ and W 46+ charge exchange emission contaminates the long-established carbon measurement at 529 nm. Fortunately the wavelength and relative intensity of the tungsten charge exchange lines is predictable and their influence can be mitigated when they are included in the spectral fit. Neon based charge exchange measurements at 525 nm are now preferred on JET since the ITER-like wall, however in this case an unidentified tungsten magnetic dipole transition contaminates the spectrum when the electron temperature is low.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combining diagnostics, modeling, and control systems for automated alignment of the TES beamline

X-ray beamlines are essential components of all synchrotron light sources. Practical operations involve frequent variation in beamline component positions and orientation, particularly when photon beam parameters shift due to experimental needs, or due to variations in the incoming photon beam. The alignment process can be time consuming and takes away from valuable beam time for experimental data collection. We describe progress in the automation of certain alignment tasks on the tender-energy X-ray spectroscopy (TES) beamline at the National Synchrotron Light Source II (NSLS-II). The beamline is controlled using the BlueSky software in which high level experimental plans guide the beamline components during an experiment. Numerous software packages exist for beamline modeling, and they may be tied to the beamline control system using a package we are continuing to develop called Sirepo-Bluesky. The photon beam distribution may be measured with fluorescent screens, and a relation between beam and machine state can be found by varying the mirror and aperture settings over a multi-dimensional range. We describe the results of such parameter varying measurements and how we are combining Sirepo-Bluesky with machine learning methods and reduced models to automate mirror alignment on the TES beamline.

36 MATERIALS SCIENCE↗

Performance of the MICE diagnostic system

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.

43 PARTICLE ACCELERATORS↗

Single electron in a storage ring: a probe into the fundamental properties of synchrotron radiation and a powerful diagnostic tool

An experimental study of undulator radiation generated by a single electron was carried out at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. Photons were detected with a single-photon avalanche diode (SPAD) at an average rate of 20 kHz, corresponding to one detection every few hundred revolutions. Events were continuously recorded by a picosecond event timer for as long as 5 minutes at a time. The collected data were used to directly test the predictions of classical Poisson photostatistics. The study was motivated in part by a previous observation of sub-Poissonian statistics in a similar experiment with synchrotron radiation. In addition, we show that the time series of recorded events can be used to study the synchrotron motion of a single electron, yielding dynamical parameters such as the phase jitter of the radiofrequency cavity and the dependence of the synchrotron period on amplitude. Research plans for further experiments are also discussed.

47 OTHER INSTRUMENTATION↗

A public website for the automated assessment and validation of SARS-CoV-2 diagnostic PCR assays

Abstract Summary Polymerase chain reaction-based assays are the current gold standard for detecting and diagnosing SARS-CoV-2. However, as SARS-CoV-2 mutates, we need to constantly assess whether existing PCR-based assays will continue to detect all known viral strains. To enable the continuous monitoring of SARS-CoV-2 assays, we have developed a web-based assay validation algorithm that checks existing PCR-based assays against the ever-expanding genome databases for SARS-CoV-2 using both thermodynamic and edit-distance metrics. The assay-screening results are displayed as a heatmap, showing the number of mismatches between each detection and each SARS-CoV-2 genome sequence. Using a mismatch threshold to define detection failure, assay performance is summarized with the true-positive rate (recall) to simplify assay comparisons. Availability and implementation The assay evaluation website and supporting software are Open Source and freely available at https://covid19.edgebioinformatics.org/#/assayValidation, https://github.com/jgans/thermonucleotide BLAST and https://github.com/LANL-Bioinformatics/assay_validation. Supplementary information Supplementary data are available at Bioinformatics online.

59 BASIC BIOLOGICAL SCIENCES↗

The bar rotation rate as a diagnostic of dark matter content in the centre of disc galaxies

We investigate the link between the bar rotation rate and dark matter content in barred galaxies by concentrating on the cases of the lenticular galaxies NGC 4264 and NGC 4277. These two gas-poor galaxies have similar morphologies, sizes, and luminosities. But, NGC 4264 hosts a fast bar, which extends to nearly the corotation, while the bar embedded in NGC 4277 is slow and falls short of corotation. We derive the fraction of dark matter ƒ DM, bar within the bar region from Jeans axisymmetric dynamical models by matching the stellar kinematics obtained with the MUSE integral-field spectrograph and using SDSS images to recover the stellar mass distribution. We build mass-follows-light models as well as mass models with a spherical halo of dark matter, which is not tied to the stars. We find that the inner regions of NGC 4277 host a larger fraction of dark matter (⁠ƒ DM,bar = 0.53±0.02⁠) with respect to NGC 4264 (⁠(⁠ƒ DM,bar = 0.33±0.04⁠) in agreement with the predictions of theoretical works and the findings of numerical simulations, which have found that fast bars live in baryon-dominated discs, whereas slow bars experienced a strong drag from the dynamical friction due to a dense DM halo. This is the first time that the bar rotation rate is coupled to fDM, bar derived from dynamical modelling.

79 ASTRONOMY AND ASTROPHYSICS↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗