Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]↗

Design and Characterization of an Extremely-Sensitive, Large-Volume Gamma-Ray Spectrometer for Environmental Samples

A large volume gamma spectrometer was designed and constructed to analyze foodstuffs and environmental samples having low radionuclide concentrations. This system uses eight 11-cm × 42.5-cm × 5.5-cm NaI(Tl) detectors, chosen due to their relatively high sensitivity and availability and arranged in an octagonal configuration. The sensitive volume of the system is ~28 cm in diameter and ~42 cm deep. Shielding consists of an 86-cm × 86-cm square, 64-cm-tall lead brick enclosure with 18-cm-thick lead walls lined by 0.3-cm-thick copper plates. An aluminum top was machined to suspend the detectors within this shield. The shielding reduces background counts by 72% at 100 keV and 42% at 1,000 keV. The positional variability in sensitivity of the well was determined by both simulation and experiment. A 2.1-L volume of nearly uniform sensitivity, varying less than 10%, exists in the well's center. Energy resolutions of 14.6% and 7.8% were measured for 241 Am and 137 Cs, respectively. Energy resolution shows a 0.2% variation for both 241 Am and 137 Cs as a function of position within all regions of the well’s central sensitive volume. Dead time was also determined to be less than 35% for all sources measured in the system, the largest of which had an activity of 1,760 kBq. Simulated results for various source geometries show higher counts for smaller samples, especially at lower energies due to less attenuation of low energy photons. In conclusion, minimum detectable activities were determined for all source energies used, less than 5.1 Bq kg -1 for reasonable background and sample counting times.

47 OTHER INSTRUMENTATION↗

Proof-of-concept of a neutron time-of-flight ellipsoidal detector

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

Jeet, J. (ORCID:0000000291091563)↗

Wigner time delay in photoionization: a 1D model study

Abstract In scattering theory, the Wigner–Smith time delay, calculated through a phaseshift derivative or its multichannel generalization, has been demonstrated to measure the amount of delay or advance experienced by colliding particles during their interaction with the scattering potential. Fetic, Becker, and Milosevic argue that this concept cannot be extended to include photoionization, viewed as a half-scattering experiment. Their argument is based on the lack of information about scattering phaseshifts in the part of the wavefunction (satisfying the ingoing-wave boundary condition) going to the detector. This article aims to test this claim by examining a photodetachment process in a simple 1D model with a short-range symmetrical potential. Using time-dependent perturbation theory with a dipole interaction, the relevant wavepacket of the outgoing particle is analyzed and compared to the free wavepacket as a reference. Our findings confirm that, indeed, a time delay arises in the liberated fragmentation wavepacket, which is expressed as an energy derivative of the scattering phaseshift. Our study highlights that the source of the phaseshift content in the wavepacket arriving at the detector is the dipole matrix element, which is a direct consequence of imposing the ingoing-wave boundary condition. We illustrate our results through numerical simulations of both the non-free and free wavepackets. The amount of the observed time delay is found to be half of that appearing in a typical scattering experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Inference of bipolar neutrino flavor oscillations near a core-collapse supernova based on multiple measurements at Earth

Neutrinos in compact-object environments, such as core-collapse supernovae, can experience various kinds of collective effects in flavor space, engendered by neutrino-neutrino interactions. These include “bipolar” collective oscillations, which are exhibited by neutrino ensembles where different flavors dominate at different energies. Considering the importance of neutrinos in the dynamics and nucleosynthesis in these environments, it is desirable to ascertain whether an Earth-based detection could contain signatures of bipolar oscillations that occurred within a supernova envelope. To that end, we, in this study, continue examining a cost-function formulation of statistical data assimilation (SDA) to infer solutions to a small-scale model of neutrino flavor transformation. SDA is an inference paradigm designed to optimize a model with sparse data. Our model consists of two monoenergetic neutrino beams with different energies emanating from a source and coherently interacting with each other and with a matter background, with radially varying interaction strengths. We attempt to infer flavor transformation histories of these beams using simulated measurements of the flavor content at locations “in vacuum” (that is, far from the source), which could in principle correspond to Earth-based detectors. Within the scope of this small-scale model, we found that: (i) based on such measurements, the SDA procedure is able to infer whether bipolar oscillations had occurred within the protoneutron star envelope, and (ii) if the measurements sample the full amplitude of the neutrino oscillations in vacuum, then the amplitude of the prior bipolar oscillations is well predicted. This result intimates that the inference paradigm can well complement numerical integration codes, via its ability to infer flavor evolution at physically inaccessible locations.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Measurement of Neutrino Oscillation Parameters with 10 Years of Data from the NOvA Experiment

This Letter reports measurements of muon-neutrino disappearance and electron-neutrino appearance and the corresponding antineutrino processes between the two NOvA detectors in the NuMI neutrino beam. These measurements use a dataset with double the neutrino mode beam exposure that was previously analyzed, along with improved simulation and analysis techniques. A joint fit to these samples in the three-flavor paradigm results in the most precise single-experiment constraint on the atmospheric neutrino mass-splitting, $Δm^2_{32}= 2.431^{+0.036}_{-0.034} (-2.479^{+0.036}_{-0.036}) \times 10^{-3}$~eV$^2$ if the mass ordering is Normal (Inverted). In both orderings, a region close to maximal mixing with $\sin^2θ_{23}=0.55_{+0.06}^{-0.02}$ is preferred. The NOvA data show a mild preference for the Normal mass ordering with a Bayes factor of 2.4 (corresponding to 70% of the posterior probability), indicating that the Normal ordering is 2.4 times more probable than the Inverted ordering. When incorporating a 2D $Δm^2_{32}\textrm{--}\sin^2 2θ_{13}$ constraint based on Daya Bay data, this preference strengthens to a Bayes factor of 6.6 (87\%).

FOS: Physical sciences↗

ADRIANO2 Calorimeter Performance from 2022 Test Beams

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration. The ADRIANO2 Calorimeter Prototype consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. Čerenkov light from the lead glass are exploited to for high resolution timing measurements, while high granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle detection for REDTOP as it is crucial for a calorimeter to detect the decay products of eta/eta-prime mesons. Measurements were collected on ADRIANO2 between February to December 2022 to evaluate the detector performance at Fermilab’s Test Beam Facility. The key metrics extracted from my analysis are the detector’s efficiency for various tile configuration and light-yield which will then be used as parameters for an upgraded REDTOP monte-carlo simulation campaign. An in-depth analysis of ADRIANO2 performance are detailed in this presentation.

43 PARTICLE ACCELERATORS↗

Intelligent Triggers for Rare Event Detection in Liquid Argon Detectors

Next-generation neutrino experiments like SBND and DUNE rely on Liquid Argon Time Projection Chambers (LArTPCs), which produce exceptionally detailed data at high volume. Capturing rare or unexpected events in real-time is a major challenge. Our project explores the use of machine learning, specifically autoencoder-based anomaly detection, to identify unusual activity directly from raw detector signals. Inspired by successes at the CMS experiment, we demonstrate that such methods can be adapted to LArTPCs and show promising results in both simulated studies and early steps toward real-time hardware deployment. This approach could open new avenues for detecting signals from physics beyond the Standard Model.

Chung, Seokju [Columbia U. (main)]↗

Optimization Studies of Radiation Shielding for the PIP-II Project at Fermilab

The PIP-II project at Fermilab, which includes an 800-MeV superconducting LINAC, demands rigorous radiation shielding optimization to meet safety requirements. We updated the MARS geometry model to reflect new magnet and collimator designs and introduced high-resolution detector planes to better capture radiation field distributions. To overcome the significant computational demands, we implemented a well-known branching technique that drastically reduced simulation runtimes while maintaining statistical integrity. This was achieved through particle splitting and the application of Russian Roulette techniques. Additionally, new graphical tools were created to streamline data visualization and MARS code usability.

Makovec, Alajos [Fermilab] (ORCID:0000000286157492↗

Dust environment of Comet Halley

Advances in the understanding of comet Halley's dust environment are highlighted. Spacecraft results on the dust composition, the detection of subfemtogram grains, and the particle-mass distribution; jets and the dust-emission pattern; the existence of discrete sources on the nucleus surface and the determination of their locations from day-to-day motions of coma features; CN jets; large-scale phenomena, including an antitail, streamers, and a sunward spike; infrared observations, such as the 3.4 microns emission feature, applications of array detectors, and rare far-infrared data; the chemical modification of low-temperature ices by UV and cosmic-ray irradiation processes, their laboratory simulations, and applications to the evolution of comets; the interstellar-connection models of comet origin; and the formation of a mantle made of refractory organic material on the nucleus surface.

Sekanina, Z.↗

Nature's crucible: Manufacturing optical nonlinearities for high resolution, high sensitivity encoding in the compound eye of the fly, Musca domestica

The number of pixels per unit area sampling an image determines Nyquist resolution. Therefore, the highest pixel density is the goal. Unfortunately, as reduction in pixel size approaches the wavelength of light, sensitivity is lost and noise increases. Animals face the same problems and have achieved novel solutions. Emulating these solutions offers potentially unlimited sensitivity with detector size approaching the diffraction limit. Once an image is 'captured', cellular preprocessing of information allows extraction of high resolution information from the scene. Computer simulation of this system promises hyperacuity for machine vision.

Wilcox, Mike↗

Hires and beyond

The High-Resolution image construction program (HiRes) used at IPAC is based on the Maximum Correlation Method. After HiRes intensity images are constructed from IRAS data, additional images are needed to aid in scientific interpretation. Some of the images that are available for this purpose show the fitting noise, estimates of the achieved resolution, and detector track maps. Two methods have been developed for creating color maps without discarding any more spatial information than absolutely necessary: the 'cross-band simulation' and 'prior-knowledge' methods. These maps are demonstrated using the survey observations of a 2 x 2 degree field centered on M31. Prior knowledge may also be used to achieve super-resolution and to suppress ringing around bright point sources observed against background emission. Tools to suppress noise spikes and for accelerating convergence are also described.

Fowler, John W.↗

Swift Burst Alert Telescope (BAT) Instrument Response

The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. In this talk, we describe the BAT instrument response as determined to an accuracy suitable for gamma-ray burst studies. We will also discuss the public data analysis tools developed to calculate the BAT response to sources at different energies and locations in the FOV. The level of accuracy required for the BAT instrument response used for the hard x-ray survey is significantly higher because this response must be used in the iterative clean algorithm for finding fainter sources. Because the bright sources add a lot of coding noise to the BAT sky image, fainter sources can be seen only after the counts due to the bright sources are removed. The better we know the BAT response, the lower the noise in the cleaned spectrum and thus the more sensitive the survey. Since the BAT detector plane consists of 32768 individual, 4 mm square CZT gamma-ray detectors, the most accurate BAT response would include 32768 individual detector response functions to separate mask modulation effects from differences in detector efficiencies! We describe OUT continuing work to improve the accuracy of the BAT instrument response and will present the current results of Monte Carlo simulations as well as BAT ground calibration data.

Parsons, A.↗

Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

Cucinotta, Francis A.↗

Extended HXR Sources - Albedo Patches or Coronal Sources

Extended HXR sources in the presence of compact footpoints have been reported based on visibility amplitudes from different detectors. Attempts have been made to determine the location and extent of these sources through direct imaging. Results of this work will be described for simulated sources and for specific flares at different solar longitudes, with a discussion of the possible nature of the extended sources as either albedo patches or coronal sources or a combination of the two.

Dennis, Brian R.↗

Thermal Impact of Cosmic Ray Interaction with an XRay Microcalorimeter Array

The X-ray Integral Field Unit (X-IFU) instrument on the Athena mission will be positioned at the Lagrangian point L2 and be subject to cosmic rays generated by astrophysics sources, primarily relativistic protons. Previous simulations have shown that particles of energy higher than 150 MeV will make it through the outer layers of the satellite. They will reach the detector wafer with a rate of 3 cts/sq. cm/s and a most probable energy deposited in the Si frame supporting the array at 150 keV. These events can affect the energy resolution of the detectors through the thermal fluctuations that they produce. This study assesses this potential problem and discusses two suggested design approaches to decrease the impact of cosmic ray in order to limit their effect to their allocation of 0.2 eV within the Athena/X-IFU energy-resolution budget. The first is the addition of a coating layer of high heat capacity material (e.g., Pd) and the second is the splitting of this coating into two thermal regions near the TES array to keep the heat away from the array. Implementing these two features is predicted to cause a decrease in the number of events above 1 μK by more than a factor 10 to ~ 1.5 cps when compared to an equivalent design without these features.

Antoine R. Miniussi↗

JWST/MIRI Coronagraphic Performances as Measured on-Sky

Context . Characterization of directly imaged exoplanets is one of the most eagerly anticipated science functions of the James Webb Space Telescope . MIRI, the mid-IR instrument, has the capability to provide unique spatially resolved photometric data points in a spectral range never before achieved for such objects. Aims . We aim to present the very first on-sky contrast measurements of the MIRI coronagraphs. In addition to a classical Lyot coronagraph at the longest wavelength, this observing mode implements the concept of the four-quadrant phase mask for the very first time in a space telescope. Methods . We observed single stars together with a series of reference stars to measure raw contrasts as they are delivered on the detector, as well as reference-subtracted contrasts. Results . The MIRI coronagraphs achieve raw contrasts better than 10 −3 at the smallest angular separations (within 1″) and about 10 −5 farther out (beyond 5 ~ 6″). Subtracting the residual diffracted light left behind the coronagraph has the potential to bring the final contrast down to the background- and detector-limited noise floor at most angular separations (a few times 10 −5 at less than 1″). Conclusions . The MIRI coronagraphs behave as expected from simulations. In particular, the raw contrasts for all four coronagraphs are fully consistent with the diffractive model. Contrasts obtained by subtracting reference stars also meet expectations and are fully demonstrated for two four-quadrant phase masks (F1065C and F1140C). The worst contrast, measured at F1550C, is very likely due to a variation in the phase aberrations at the primary mirror during the observations, and not an issue with the coronagraph itself. We did not perform reference star subtraction with the Lyot mask at F2300C, but we anticipate that it would bring the contrast down to the noise floor.

High angular resolution instrumentation↗