Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Measurement Of Neutron Radius In Lead By Parity Violating Scattering Flash ADC DAQ

This dissertation reports the experiment PREx, a parity violation experiment which is designed to measure the neutron radius in 208 Pb. PREx is performed in hall A of Thomas Jefferson National Accelerator Facility from March 19th to June 21st. Longitudionally polarized electrons at energy 1 GeV scattered at and angle of θ lab = 5.8 ° from the Lead target. Beam corrected pairty violaing counting rate asymmetry is (A corr = 594 ± 50(stat) ± 9(syst))ppb at Q 2 = 0.009068GeV 2 . This dissertation also presents the details of Flash ADC Data Acquisition(FADC DAQ) system for Moller polarimetry in Hall A of Thomas Jefferson National Accelerator Facility. The Moller polarimeter measures the beam polarization to high precision to meet the specification of the PREx(Lead radius experiment). The FADC DAQ is part of the upgrade of Moller polarimetery to reduce the systematic error for PREx. The hardware setup and the results of the FADC DAQ analysis are presented

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and Validation of MFiX-PIC

This work is aimed at verification and validation (V&V) of particle-in-cell (PIC) approach in the National Energy Technology Laboratory’s (NETL) Multiphase Flow with Interphase eXchanges (MFiX-PIC) which was officially released in April 2019. Under verification, the results from MFiX-PIC are compared with exact or analytical solutions, while experimental results are used for benchmarking under validation. The test suite consists of the following cases: Terminal velocity. Particle advection in time-varying flow field. Particle settling in a dense medium. Evaporation. Rayleigh-Taylor instability. Minimum fluidization. Mini-circulating fluidized bed. The cases reported in a format consistent with the existing Verification and Validation Manual (Musser et al., 2018) explore a wide range of flow velocities and concentration regimes. Only one case considered in this work verifies the implementation of heat and mass transfer routines in MFiX-PIC, while a few other studies are currently underway to further expand the validation space in reacting flows. This study highlights the need for a rigorous analysis to objectively quantify the effect of model parameters. In addition, there is a scarcity of high-quality experimental data in the literature suitable for validating PIC methodology. Future efforts would include performing experiments which provide results for a valuable database. While designing such experiments, particle count should be significant to have sufficient particles per parcel while maintaining an optimal parcel to cell volume ratio. Also, datasets should have objectively assessed experimental uncertainty whereby confidence interval in those measurements become more explicit.

42 ENGINEERING↗

Stability of Cool Cores during Galaxy Cluster Growth: A Joint Chandra/SPT Analysis of 67 Galaxy Clusters along a Common Evolutionary Track Spanning 9 Gyr

We present the results of a joint analysis of Chandra X-ray and South Pole Telescope (SPT) Sunyaev–Zel’dovich (SZ) observations targeting the first sample of galaxy clusters at 0.3 < z < 1.3, selected to be the progenitors of well-studied nearby clusters based on their expected accretion rate. We develop a new procedure in order to tackle the analysis challenge that is estimating the intracluster medium (ICM) properties of low-mass and high-redshift clusters with ~150 X-ray counts. One of the dominant sources of uncertainty on the ICM density profile estimated with a standard X-ray analysis with such shallow X-ray data is due to the systematic uncertainty associated with the ICM temperature obtained through the analysis of the background-dominated X-ray spectrum. We show that we can decrease the uncertainty on the density profile by a factor varying between 2 and 8 with a joint deprojection of the X-ray surface brightness profile measured by Chandra and the SZ-integrated Compton parameter available in the SPT cluster catalog. We apply this technique to the whole sample of 67 clusters in order to track the evolution of the ICM core density during cluster growth. We confirm that the evolution of the gas density profile is well modeled by the combination of a fixed core and a self-similarly evolving non-cool-core profile. We show that the fraction of cool cores in this sample is remarkably stable with redshift although clusters have gained a factor of ~4 in total mass over the past ~9 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-Time Radiological Source Term Estimation for Multiple Sources in Cluttered Environments

A particle filter algorithm is presented to estimate the position, strength, and cardinality of an unknown number of radioactive point sources in an obstacle-rich environment using count measurements. The algorithm addresses gaps in the prior literature by incorporating two novel elements. The first is a precomputation step in which local terrain and obstacle data is processed to compute attenuation kernels throughout the search area. This enables rapid estimation performance in obstacle-rich environments as measurements are gathered. The second novel feature is a dynamic particle allocation technique in which the number of particles is adjusted in real time to meet convergence goals. This feature allows the algorithm to scale more efficiently to scenarios with a larger number of sources. A series of computational experiments using simulated data demonstrates the algorithm’s performance in a cluttered environment with up to eight sources.

Kemp, Samuel↗

Simulating Scintillator Light Collection Using Measured Optical Reflectance

To accurately predict the light collection from a scintillating crystal through Monte Carlo simulations, it is crucial to know the angular distribution from the surface reflectance. Current Monte Carlo codes allow the user to set the optical reflectance to a linear combination of backscatter spike, specular spike, specular lobe, and Lambertian reflections. However, not all light distributions can be expressed in this way. In addition, the user seldom has the detailed knowledge about the surfaces that is required for accurate modeling. We have previously measured the angular distributions within BGO crystals and now incorporate these data as look-up-tables (LUTs) into modified Geant4 and GATE Monte Carlo codes. The modified codes allow the user to specify the surface treatment (ground, etched, or polished), the attached reflector (Lumirror(R), Teflon(R), ESR film, Tyvek(R), or TiO paint), and the bonding type (air-coupled or glued). Each LUT consists of measured angular distributions with 4o by 5o resolution in theta and phi, respectively, for incidence angles from 0? to 90? degrees, in 1o-steps. We compared the new codes to the original codes by running simulations with a 3 x 10 x 30 mm3 BGO crystal coupled to a PMT. The simulations were then compared to measurements. Light output was measured by counting the photons detected by the PMT with the 3 x 10, 3 x 30, or 10 x 30 mm2 side coupled to the PMT, respectively. Our new code shows better agreement with the measured data than the current Geant4 code. The new code can also simulate reflector materials that are not pure specular or Lambertian reflectors, as was previously required. Our code is also more user friendly, as no detailed knowledge about the surfaces or light distributions is required from the user.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects

Purpose: Recently, photon counting x-ray detectors (PCXDs) with energy discrimination capabilities have been developed for potential use in clinical computed tomography (CT) scanners. These PCXDs have great potential to improve the quality of CT images due to the absence of electronic noise and weights applied to the counts and the additional spectral information. With high count rates encountered in clinical CT, however, coincident photons are recorded as one event with a higher or lower energy due to the finite speed of the PCXD. This phenomenon is called a ''pulse pileup event'' and results in both a loss of counts (called ''deadtime losses'') and distortion of the recorded energy spectrum. Even though the performance of PCXDs is being improved, it is essential to develop algorithmic methods based on accurate models of the properties of detectors to compensate for these effects. To date, only one PCXD (model DXMCT-1, DxRay, Inc., Northridge, CA) has been used for clinical CT studies. The aim of that study was to evaluate the agreement between data measured by DXMCT-1 and those predicted by analytical models for the energy response, the deadtime losses, and the distorted recorded spectrum caused by pulse pileup effects. Methods: An energy calibration was performed using {sup 99m}Tc (140 keV), {sup 57}Co (122 keV), and an x-ray beam obtained with four x-ray tube voltages (35, 50, 65, and 80 kVp). The DXMCT-1 was placed 150 mm from the x-ray focal spot; the count rates and the spectra were recorded at various tube current values from 10 to 500 {mu}A for a tube voltage of 80 kVp. Using these measurements, for each pulse height comparator we estimated three parameters describing the photon energy-pulse height curve, the detector deadtime {tau}, a coefficient k that relates the x-ray tube current I to an incident count rate a by a=kxI, and the incident spectrum. The mean pulse shape of all comparators was acquired in a separate study and was used in the model to estimate the distorted recorded spectrum. The agreement between data measured by the DXMCT-1 and those predicted by the models was quantified by the coefficient of variation (COV), i.e., the root mean square difference divided by the mean of the measurement. Results: Photon energy versus pulse height curves calculated with an analytical model and those measured using the DXMCT-1 were in agreement within 0.2% in terms of the COV. The COV between the output count rates measured and those predicted by analytical models was 2.5% for deadtime losses of up to 60%. The COVs between spectra measured and those predicted by the detector model were within 3.7%-7.2% with deadtime losses of 19%-46%. Conclusions: It has been demonstrated that the performance of the DXMCT-1 agreed exceptionally well with the analytical models regarding the energy response, the count rate, and the recorded spectrum with pulse pileup effects. These models will be useful in developing methods to compensate for these effects in PCXD-based clinical CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for Subcontract# B539681

This report summarizes the work performed under subcontract B539681. The scope of work described in the subcontract encompasses studies of fundamental research for fast ignition. The work statement from the from the original subcontract and the subsequent extension can be summarized in three major components: modeling of electron transport in experimental targets, development of diagnostics, and experimental implementation and analysis. All three of these areas have been addressed during the subcontract period, although the tasks detailed in the original subcontract were adapted to research conditions with guidance from the technical contact. The work performed in each of these areas is described. (1) Modeling of electron transport in experimental targets - Electron transport and x-ray generation in experimental targets were modeled with the Monte Carlo code Integrated Tiger Series 3.0 (ITS 3.0). This code package was also used to model the response of Bremsstrahlung spectrometer described in the paper. The modeling helped with target and spectrometer designs and was also used to interpret the measured data from the experiments. this work is coupled to the diagnostic development and experimental analysis and is described in the deliverable of the report. (2) Diagnostic Development - During the subcontract period a filter-stack Bremsstrahlung spectrometer using image plate dosimeters was developed, tested, and calibrated. The spectrometer design and sample data taken with the spectrometer was presented at the High Temperature Plasma Diagnostics conference (Albuquerque, NM 2008). The information was also subsequently published in the peer-reviewed conference proceedings (rev. Sci. Instrum. 79:10E305 (2008)). The diagnostic was fielded on over 10 experiments at the Jupiter Laser Facility at Lawrence Livermore and was also adapted for use on OMEGA EP, was discussed in the subcontract extension. A composition study of the image plate dosimeters was also disseminated as an internal LLNL technical memo. In addition, research was performed into two other diagnostics. Single Photon Counting using a CCD (Single Hit Spectrometer) is a well-established technique in the literature. The subcontractor assisted with implementation and calibration of the Single Hit Spectrometer and developed general use software for analysis of the output data. This software is currently being used by a number of collaborators at Lawrence Livermore. The development of a Single Hit Imager was also initially explored at the beginning of the subcontract period but, under direction of the technical contact, not further pursued in order to focus on the other priorities. (3) Experimental Implementation and Analysis - The subcontractor participated in over 10 separate 2-8 week experiments at the Jupiter Laser Facility at Lawrence Livermore. On many of these experiments, the diagnostics described above were fielded to take x-ray measurements for different physics goals, including those described in the original subcontract and for studies of diagnostic related issues for the National Ignition Facility. A series of experiments were carried out on planar foil targets to study the electrons generated in the relativistic laser plasma interaction under fast ignition relevant conditions. The data was analyzed with the Monte Carlo modeling described above.

42 ENGINEERING↗

Characterization and Modeling of Contamination for Lyman Break Galaxy Samples at High Redshift

The selection of high-redshift sources from broadband photometry using the Lyman-break galaxy (LBG) technique is a well established methodology, but the characterization of its contamination for the faintest sources is still incomplete. We use the optical and near-IR data from four (ultra)deep Hubble Space Telescope legacy fields to investigate the contamination fraction of LBG samples at z∼5--8 selected using a color–color method. Our approach is based on characterizing the number count distribution of interloper sources, that is, galaxies with colors similar to those of LBGs, but showing detection at wavelengths shorter than the spectral break. Without sufficient sensitivity at bluer wavelengths, a subset of interlopers may not be properly classified, and contaminate the LBG selection. The surface density of interlopers in the sky gets steeper with increasing redshift of LBG selections. Since the intrinsic number of dropouts decreases significantly with increasing redshift, this implies increasing contamination from misclassified interlopers with increasing redshift, primarily by intermediate redshift sources with unremarkable properties (intermediate ages, lack of ongoing star formation and low/moderate dust content). Using Monte-Carlo simulations, we estimate that the CANDELS deep data have contamination induced by photometric scatter increasing from ∼2% at z∼5 to ∼6% at z∼8 for a typical dropout color ⩾1 mag, with contamination naturally decreasing for a more stringent dropout selection. Contaminants are expected to be located preferentially near the detection limit of surveys, ranging from 0.1 to 0.4 contaminants per arcmin{sup 2} at J{sub 125} = 30, depending on the field considered. This analysis suggests that the impact of contamination in future studies of z>10 galaxies needs to be carefully considered.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of an open forecasting challenge to assess skill of West Nile virus neuroinvasive disease prediction

Abstract Background West Nile virus (WNV) is the leading cause of mosquito-borne illness in the continental USA. WNV occurrence has high spatiotemporal variation, and current approaches to targeted control of the virus are limited, making forecasting a public health priority. However, little research has been done to compare strengths and weaknesses of WNV disease forecasting approaches on the national scale. We used forecasts submitted to the 2020 WNV Forecasting Challenge, an open challenge organized by the Centers for Disease Control and Prevention, to assess the status of WNV neuroinvasive disease (WNND) prediction and identify avenues for improvement. Methods We performed a multi-model comparative assessment of probabilistic forecasts submitted by 15 teams for annual WNND cases in US counties for 2020 and assessed forecast accuracy, calibration, and discriminatory power. In the evaluation, we included forecasts produced by comparison models of varying complexity as benchmarks of forecast performance. We also used regression analysis to identify modeling approaches and contextual factors that were associated with forecast skill. Results Simple models based on historical WNND cases generally scored better than more complex models and combined higher discriminatory power with better calibration of uncertainty. Forecast skill improved across updated forecast submissions submitted during the 2020 season. Among models using additional data, inclusion of climate or human demographic data was associated with higher skill, while inclusion of mosquito or land use data was associated with lower skill. We also identified population size, extreme minimum winter temperature, and interannual variation in WNND cases as county-level characteristics associated with variation in forecast skill. Conclusions Historical WNND cases were strong predictors of future cases with minimal increase in skill achieved by models that included other factors. Although opportunities might exist to specifically improve predictions for areas with large populations and low or high winter temperatures, areas with high case-count variability are intrinsically more difficult to predict. Also, the prediction of outbreaks, which are outliers relative to typical case numbers, remains difficult. Further improvements to prediction could be obtained with improved calibration of forecast uncertainty and access to real-time data streams (e.g. current weather and preliminary human cases). Graphical Abstract

54 ENVIRONMENTAL SCIENCES↗

Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detector

Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame –1 or 826 ns frame –1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. In conclusion, it was found that in burst mode the ratio of 2s to 1s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Population Count on Intel® CPU, GPU, and FPGA

Population count is a primitive used in many applications. Commodity processors have dedicated instructions for achieving high-performance population count. Motivated by the productivity of high-level synthesis and the importance of population count, in this paper we investigated the OpenCL implementations of population count algorithms, and evaluated their performance and resource utilizations on an FPGA. Based on the results, we select the most efficient implementation. Then we derived a reduction pattern from a representative application of population count. We parallelized the reduction with atomic functions, and optimized it with vectorized memory accesses, tree reduction, and compute-unit duplication. We evaluated the performance of the reduction kernel on an Intel (R) Xeon (R) CPU and an Intel (R) IrisT Pro integrated GPU, and an FPGA card that features an Intel (R) Arria (R) 10 FPGA. When DRAM memory bandwidth is comparable on the three computing platforms, the FPGA can achieve the highest kernel performance for large workload. On the other hand, we described performance bottlenecks on the FPGA. To make FPGAs more competitive in raw performance compared to high-performant CPU and GPU platforms, it is important to increase external memory bandwidth, minimize data movement between a host and a device, and reduce OpenCL runtime overhead on an FPGA.

heterogeneous computing↗

Application of an EMCCD Camera for Calibration of Hard X-Ray Telescopes

Recent technological innovations now make it feasible to construct hard x-ray telescopes for space-based astronomical missions. Focusing optics are capable of improving the sensitivity in the energy range above 10 keV by orders of magnitude compared to previously used instruments. The last decade has seen focusing optics developed for balloon experiments and they will soon be implemented in approved space missions such as the Nuclear Spectroscopic Telescope Array (NuSTAR) and ASTRO-H. The full characterization of x-ray optics for astrophysical and solar imaging missions, including measurement of the point spread function (PSF) as well as scattering and reflectivity properties of substrate coatings, requires a very high spatial resolution, high sensitivity, photon counting and energy discriminating, large area detector. Novel back-thinned Electron Multiplying Charge-Coupled Devices (EMCCDs) are highly suitable detectors for ground-based calibrations. Their chip can be optically coupled to a microcolumnar CsI(Tl) scintillator via a fiberoptic taper. Not only does this device exhibit low noise and high spatial resolution inherent to CCDs, but the EMCCD is also able to handle high frame rates due to its controllable internal gain. Additionally, thick CsI(Tl) yields high detection efficiency for x-rays. This type of detector has already proven to be a unique device very suitable for calibrations in astrophysics: such a camera was used to support the characterization of the performance for all NuSTAR optics. Further optimization will enable similar cameras to be improved and used to calibrate x-ray telescopes for future space missions. In this paper, we discuss the advantages of using an EMCCD to calibrate hard x-ray optics. We will illustrate the promising features of this detector solution using examples of data obtained during the ground calibration of the NuSTAR telescopes performed at Columbia University during 2010/2011. Finally, we give an outlook on ongoing development and optimizations, such as the use of single photon counting mode to enhance spectral resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PubChemLite Plus Collision Cross Section (CCS) Values for Enhanced Interpretation of Nontarget Environmental Data

Finding relevant chemicals in the vast (known) chemical space is a major challenge for environmental and exposomics studies leveraging nontarget high resolution mass spectrometry (NT-HRMS) methods. Chemical databases now contain hundreds of millions of chemicals, yet many are not relevant. This article details an extensive collaborative, open science effort to provide a dynamic collection of chemicals for environmental, metabolomics, and exposomics research, along with supporting information about their relevance to assist researchers in the interpretation of candidate hits. The PubChemLite for Exposomics collection is compiled from ten annotation categories within PubChem, enhanced with patent, literature and annotation counts, predicted partition coefficient (logP) values, as well as predicted collision cross section (CCS) values using CCSbase. Monthly versions are archived on Zenodo under a CC-BY license, supporting reproducible research, and a new interface has been developed, including historical trends of patent and literature data, for researchers to browse the collection. This article details how PubChemLite can support researchers in environmental and exposomics studies, describes efforts to increase the availability of experimental CCS values, and explores known limitations and potential for future developments. The data and code behind these efforts are openly available.

PubChem↗

Dependence on pseudorapidity and centrality of charged hadron production in PbPb collisions at a nucleon-nucleon centre-of-mass energy of 2.76 TeV

A measurement is presented of the charged hadron multiplicity in hadronic PbPb collisions, as a function of pseudorapidity and centrality, at a collision energy of 2.76 TeV per nucleon pair. The data sample is collected using the CMS detector and a minimum-bias trigger, with the CMS solenoid off. The number of charged hadrons is measured both by counting the number of reconstructed particle hits and by forming hit doublets of pairs of layers in the pixel detector. The two methods give consistent results. The charged hadron multiplicity density dN(ch)/d eta, evaluated at eta=0 for head-on collisions, is found to be 1612 +/- 55, where the uncertainty is dominated by systematic effects. Comparisons of these results to previous measurements and to various models are also presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prompt determination of evacuee radiation dose from a nuclear event

In anticipation of a nuclear terrorist attack, techniques to quickly assess the radiation exposure of evacuees have been developed. Based on past experience relating neutron radiation exposures to activation products, quick measurement of activation products (counting time of a few seconds) in personal items exposed to significant levels of radiation should allow a neutron dose assessment. This approach allows prompt collection of important data on human exposure following a terrorist attack. Data collected will facilitate triage decisions for timely emergency medical treatment to ameliorate the radiation effects on exposed individuals. Experiments with ubiquitous items exposed to a neutron source will be outlined and presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GATA-1 directly regulates Nanog in mouse embryonic stem cells

Nanog safeguards pluripotency in mouse embryonic stem cells (mESCs). Insight into the regulation of Nanog is important for a better understanding of the molecular mechanisms that control pluripotency of mESCs. In a silico analysis, we identify four GATA-1 putative binding sites in Nanog proximal promoter. The Nanog promoter activity can be significantly repressed by ectopic expression of GATA-1 evidenced by a promoter reporter assay. Mutation studies reveal that one of the four putative binding sites counts for GATA-1 repressing Nanog promoter activity. Direct binding of GATA-1 on Nanog proximal promoter is confirmed by electrophoretic mobility shift assay and chromatin immunoprecipitation. Our data provide new insights into the expanded regulatory circuitry that coordinates Nanog expression. - Highlights: • The Nanog proximal promoter conceives functional element for GATA-1. • GATA-1 occupies the Nanog proximal promoter in vitro and in vivo. • GATA-1 transcriptionally suppresses Nanog.

60 APPLIED LIFE SCIENCES↗

Synthesis, structural characterization and properties of SrAl{sub 4−x}Ge{sub x}, BaAl{sub 4−x}Ge{sub x}, and EuAl{sub 4−x}Ge{sub x} (x≈0.3–0.4)—Rare examples of electron-rich phases with the BaAl{sub 4} structure type

Three solid solutions with the general formula AEAl{sub 4−x}Ge{sub x} (AE=Eu, Sr, Ba; 0.32(1)≤x≤0.41(1)) have been synthesized via the aluminum self-flux method, and their crystal structures have been established from powder and single-crystal X-ray diffraction. They are isotypic and crystallize with the well-known BaAl{sub 4} structure type, adopted by the three AEAl{sub 4} end members. In all structures, Ge substitutes Al only at the 4e Wyckoff site. Results from X-rays photoelectron spectroscopy on EuAl{sub 4−x}Ge{sub x} and EuAl{sub 4} indicate that the interactions between the Eu{sup 2+} cations and the polyanionic framework are enhanced in the Ge-doped structure, despite the slightly elevated Fermi level. Magnetic susceptibility measurements confirm the local moment magnetism, expected for the [Xe]4f{sup 7} electronic configuration of Eu{sup 2+} and suggest strong ferromagnetic interactions at cryogenic temperatures. Resistivity data from single-crystalline samples show differences between the title compounds, implying different bonding characteristics despite the close Debye temperatures. A brief discussion on the observed electron count and homogeneity ranges for AEAl{sub 4−x}Ge{sub x} (AE=Eu, Sr, Ba) is also presented. - Graphical abstract: AEAl{sub 4−x}Ge{sub x} (AE=Eu, Sr, Ba; 0.32(1)≤x≤0.41(1)), three “electron-rich” phases with BaAl{sub 4} structure type have been synthesized and characterized. Display Omitted - Highlights: • Three BaAl{sub 4}-type ternary aluminum germanides have been synthesized with Eu, Sr and Ba. • Eu, Sr and Ba cations have no apparent influence on the solubility of Ge. • The Ge atoms substitute Al on one of two framework sites, thereby strengthening the interactions between the cations and the polyanionic framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct comparison of wire, foil, and hybrid X-pinches on a 200 kA, 150 ns current driver

Wire X-pinches (WXPs) have been studied comprehensively as fast (~1 ns pulse width), small (~1 μm) x-ray sources, created by twisting two or more fine wires into an “X” to produce a localized region of extreme magnetic pressure at the cross-point. Recently, two alternatives to the traditional WXP have arisen: the hybrid X-pinch (HXP), composed of two conical electrodes bridged by a thin wire or capillary, and the laser-cut foil X-pinch (LCXP), cut from a thin foil using a laser. We present a comparison of copper wire, hybrid, and laser-cut foil X-pinches on a single experimental platform: UC San Diego’s ~200 kA, 150 ns rise time GenASIS driver. All configurations produced 1–2 ns pulse width, ≤5 μm soft x-ray (Cu L-shell, ~1 keV) sources (resolutions diagnostically limited) with comparable fluxes. WXP results varied with linear mass and wire count, but consistently showed separate pinch and electron-beam-driven sources. LCXPs produced the brightest (~1 MW), smallest (≤5 μm) Cu K-shell sources, and spectroscopic data showed both H-like Cu K α lines indicative of source temperatures ≥2 keV, and cold K α (~8050 eV) characteristic of electron beam generated sources, which were not separately resolved on other diagnostics (within 1–2 ns and ≤200 μm). HXPs produced minimal K-shell emission and reliably single, bright, and small L-shell sources after modifications to shape the early current pulse through them. Benefits and drawbacks for each configuration are discussed to provide potential X-pinch users with the information required to choose the configuration best suited to their needs.

42 ENGINEERING↗