Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Effect of Cathode Cooling in Three-Dimensional Simulations of an Atmospheric Pressure Glow Discharge

The Atmospheric Pressure Glow Discharge (APGD) is a relatively simple and versatile plasma source used in a wide range of applications. Active cooling of the cathode can effectively mitigate instabilities, leading to glow-to-arc transitions. This study investigates the effect of varying the degree of cathode cooling in APGD with a planar cathode in helium. The plasma flow model incorporates mass conservation, chemical species transport, momentum conservation, conservation of thermal energy of heavy species and of electrons, and electrostatics. The model is applied to time-dependent simulations through a three-dimensional computational domain describing the whole discharge, without geometric symmetry or steady-state assumptions. Simulations of an experimentally characterized APGD explore the effects of electric current and cathode cooling—ranging from thermally insulated to extreme convective cooling. Results show the formation of an annular region with high electric field over the cathode surface under conditions of high current and low cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Multiwavelength Study of the Cool Core Cluster MACS J1447.4+0827

Clusters of galaxies are outstanding laboratories for understanding the physics of supermassive black hole (SMBH) feedback. Here we present the first Chandra, Karl G. Jansky Very Large Array, and Hubble Space Telescope analysis of MACS J1447.4+0827 (z = 0.3755), one of the strongest cool core clusters known, in which extreme feedback from its central SMBH is needed to prevent the hot intracluster gas from cooling. Using this multiwavelength approach, including 70 ks of Chandra X-ray observations, we detect the presence of collimated jetted outflows that coincide with a southern and a northern X-ray cavity. The total mechanical power associated with these outflows (P {sub cav} ≈ 6 × 10{sup 44} erg s{sup −1}) is roughly consistent with the energy required to prevent catastrophic cooling of the hot intracluster gas (L {sub cool} = 1.71 ± 0.01 × 10{sup 45} erg s{sup −1} for t {sub cool} = 7.7 Gyr), implying that powerful SMBH feedback was in place several Gyr ago in MACS J1447.7+0827. In addition, we detect the presence of a radio minihalo that extends over 300 kpc in diameter (P {sub 1.4GHz} = 3.0 ± 0.3 × 10{sup 24} W Hz{sup −1}). The X-ray observations also reveal an ∼20 kpc plumelike structure that coincides with optical dusty filaments that surround the central galaxy. Overall, this study demonstrates that the various physical phenomena occurring in the most nearby clusters of galaxies are also occurring in their more distant analogs.

79 ASTRONOMY AND ASTROPHYSICS↗

A Detailed Study of the Most Relaxed SPT-selected Galaxy Clusters: Properties of the Cool Core and Central Galaxy

We present a multi-wavelength analysis of the four most relaxed clusters in the South Pole Telescope 2500 deg 2 survey, which lie at 0.55 < z < 0.75. This study, which utilizes new, deep data from Chandra and Hubble, along with ground-based spectroscopy from Gemini and Magellan, improves significantly on previous studies in both depth and angular resolution, allowing us to directly compare to clusters at z~0. We find that the temperature, density, and entropy profiles of the intracluster medium (ICM) are very similar among the four clusters, and share similar shapes to clusters at z~0. Specifically, we find no evidence for deviations from self similarity in the temperature profile over the radial range 10kpc < r < 1Mpc, implying that the processes responsible for preventing runaway cooling over the past >6 Gyr are, at least roughly, preserving self similarity. We find typical metallicities of ~0.3 Zsun in the bulk of the ICM, rising to ~0.5 Zsun in the inner ~100 kpc, and reaching ~1 Zsun at r < 10kpc. This central excess is similar in magnitude to what is observed in the most relaxed clusters at z~0, suggesting that both the global metallicity and the central excess that we see in cool core clusters at z~0 were in place very early in the cluster lifetime and, specifically, that the central excess is not due to late-time enrichment by the central galaxy. Consistent with observations at z~0, we measure a diversity of stellar populations in the central brightest cluster galaxies of these four clusters, with star formation rates spanning a factor of ~500, despite the similarity in cooling time, cooling rate, and central entropy. These data suggest that, while the details vary dramatically from system to system, runaway cooling has been broadly regulated in relaxed clusters over the past 6 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

Crust-cooling Models Are Insensitive to the Crust–Core Transition Pressure for Realistic Equations of State

Neutron stars cooling after sustained accretion outbursts provide unique information about the neutron star crust and underlying dense matter. Comparisons between astronomical observations of these cooling transients and model calculations of neutron star crust cooling have frequently been used to constrain neutron star properties such as the mass, radius, crust composition, and presence of nuclear pasta. These calculations often use a fixed pressure at which the crust–core transition happens, though this quantity depends on the dense matter equation of state. We demonstrate that varying the crust–core transition pressure in a manner consistent with adopting various equations of state results in modest changes to the crust-cooling light curve. Finally, this validates the approach adopted in most crust-cooling studies to date, where the neutron star mass and radius are varied while leaving the crust–core transition pressure constant.

79 ASTRONOMY AND ASTROPHYSICS↗

COOL-LAMPS. I. An Extraordinarily Bright Lensed Galaxy at Redshift 5.04

In this paper, we report the discovery of COOL J1241+2219, a strongly lensed galaxy at redshift z = 5.043 ± 0.002 with observed magnitude z AB = 20.47, lensed by a moderate-mass galaxy cluster at z = 1.001 ± 0.001. COOL J1241+2219 is the brightest lensed galaxy currently known at optical and near-infrared wavelengths at z $\gtrsim$ 5; it is ~5 times brighter than the prior record-holder lensed galaxy, and several magnitudes brighter than the brightest unlensed galaxies known at these redshifts. It was discovered as part of COOL-LAMPS, a collaboration initiated to find strongly lensed systems in recent public optical imaging data. We characterize the lensed galaxy, as well as the central galaxy of the lensing cluster using ground-based grizJH imaging and optical spectroscopy. We report model-based magnitudes, and derive stellar masses, dust content, metallicity, and star-formation rates via stellar-population synthesis modeling. Our lens mass modeling, based on ground-based imaging, implies a median source magnification of ~30, which puts the stellar mass and star-formation rate (in the youngest age bin, closest to the epoch of observation) at logM* = ${10.11}_{-0.26}^{+0.21}$ and SFR = ${27}_{-9}^{+13} M_⊙$ yr –1 , respectively. We constrain a star-formation history for COOL J1241+2219 consistent with constant star formation across ~1 Gyr of cosmic time, and that places this galaxy on the high-mass end of the star-forming main sequence. COOL J1241+2219 is two to four times more luminous than a galaxy with the characteristic UV luminosity at these redshifts. The UV continuum slope β = –2.2 ± 0.2 places this galaxy on the blue side of the observed distribution of galaxies at z = 5, although the lack of Lyα emission indicates dust sufficient to suppress this emission.

79 ASTRONOMY AND ASTROPHYSICS↗

The Synchrotron Low-energy Spectrum Arising from the Cooling of Electrons in Gamma-Ray Bursts

This work is a continuation of a previous effort (Panaitescu) to study the cooling of relativistic electrons through radiation (synchrotron and self-Compton) emission and adiabatic losses, with application to the spectra and light curves of the synchrotron gamma-ray burst (GRB) produced by such cooling electrons. Here, we derive the low-energy slope β LE of a GRB pulse-integrated spectrum and quantify the implications of the measured distribution of β LE . Radiative processes that produce soft integrated spectra can accommodate the harder slopes measured by CGRO/BATSE and Fermi/GBM only if the magnetic field lifetime t B is shorter than the time during which the typical GRB electrons cool to radiate below 1–10 keV, which is less than (at most) 10 radiative cooling timescales t rad of the typical GRB electron. In this case, there is a one-to-one correspondence between t B and β LE . To account for low-energy slopes β LE > -3/4, the adiabatic electron-cooling requires a similar restriction on t B . In this case, the diversity of slopes arises mostly from how the electron-injection rate varies with time (temporal power-law injection rates yield power-law low-energy GRB spectra) and not from the magnetic field timescale.

79 ASTRONOMY AND ASTROPHYSICS↗

Critical Metallicity of Cool Supergiant Formation. I. Effects on Stellar-mass Loss and Feedback

This paper systematically studies the relation between metallicity and mass loss of massive stars. We perform one-dimensional stellar evolution simulations and build a grid of ~2000 models with initial masses ranging between 11 and 60 M ⊙ and absolute metallicities Z between 0.00001 and 0.02. Steady-state winds, comprising hot main-sequence winds and cool supergiant winds, are the main drivers of the mass loss of massive stars in our models. We calculate the total mass loss over the stellar lifetime for each model. Our results reveal the existence of a critical metallicity Z c at Z ~ 10 –3 , where the mass loss exhibits a dramatic jump. If Z > Z c , massive stars tend to evolve into cool supergiants, and a robust cool wind is operational. In contrast, if Z < Z c , massive stars usually remain as blue supergiants, wherein the cool wind is not activated and the mass loss is generally weak. Moreover, we calculate the wind feedback in a 10 5 M ⊙ star cluster with the Salpeter initial mass function. The kinetic energy released by winds does not exhibit any significant transition at Z c because the wind velocity of a cool supergiant wind is low and contributes little to the kinetic energy. The effects of critical metallicity provide implications for the fates of metal-poor stars in the early universe.

79 ASTRONOMY AND ASTROPHYSICS↗

COOL-LAMPS. IV. A Sample of Bright Strongly Lensed Galaxies at 3 < z < 4

We report the discovery of five bright, strong gravitationally lensed galaxies at 3 < z < 4: COOL J0101+2055 (z = 3.459), COOL J0104–0757 (z = 3.480), COOL J0145+1018 (z = 3.310), COOL J0516–2208 (z = 3.549), and COOL J1356+0339 (z = 3.753). These galaxies have magnitudes of r AB , z AB < 21.81 mag and are lensed by galaxy clusters at 0.26 < z < 1. This sample nearly doubles the number of known bright lensed galaxies with extended arcs at 3 < z < 4. We characterize the lensed galaxies using ground-based grz/giy imaging and optical spectroscopy. We report model-based magnitudes and derive stellar masses, dust content, and star formation rates via stellar population synthesis modeling. Building lens models based on ground-based imaging, we estimate source magnifications ranging from ~29 to ~180. Combining these analyses, we derive demagnified stellar masses in the range log 10 (M * /M ⊙ ) ~ 9.69 – 10.75 and star formation rates in the youngest age bin in the range log 10 (SFR/(M ⊙ yr -1 )) ~ 0.39 – 1.46, placing the sample galaxies on the massive end of the star-forming main sequence in this redshift interval. In addition, three of the five galaxies have strong Lyα emissions, offering unique opportunities to study Lyα emitters at high redshift in future work.

79 ASTRONOMY AND ASTROPHYSICS↗

Tethered balloon-borne observations of thermal-infrared irradiance and cooling rate profiles in the Arctic atmospheric boundary layer

Clouds play an important role in controlling the radiative energy budget of the Arctic atmospheric boundary layer. To quantify the impact of clouds on the radiative heating or cooling of the lower atmosphere and of the surface, vertical profile observations of thermal-infrared irradiances were collected using a radiation measurement system carried by a tethered balloon. We present 70 profiles of thermal-infrared radiative quantities measured in summer 2020 during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition and in autumn 2021 and spring 2022 in Ny-Ålesund, Svalbard. Measurements are classified into four groups: cloudless, low-level liquid-bearing cloud, elevated liquid-bearing cloud, and elevated ice cloud. Cloudless cases display an average radiative cooling rate of about —2 K d—1 throughout the atmospheric boundary layer. Instead, low-level liquid-bearing clouds are characterized by a radiative cooling up to —80 K d—1 within a shallow layer at cloud top, while no temperature tendencies are identified underneath the cloud layer. Radiative transfer simulations are performed to quantify the sensitivity of radiative cooling rates to cloud microphysical properties. In particular, cloud top cooling is strongly driven by the liquid water path, especially in optically thin clouds, while for optically thick clouds the cloud droplet number concentration has an increased influence. Additional radiative transfer simulations are used to demonstrate the enhanced radiative importance of the liquid relative to ice clouds. To analyze the temporal evolution of thermal-infrared radiation profiles during the transitions from a cloudy to a cloudless atmosphere, a respective case study is investigated.

54 ENVIRONMENTAL SCIENCES↗

Design and evaluation of active cooling systems for Mach 6 cruise vehicle wings

Active cooling systems, which included transpiration, film, and convective cooling concepts, are examined. Coolants included hydrogen, helium, air, and water. Heat shields, radiation barriers, and thermal insulation are considered to reduce heat flow to the cooling systems. Wing sweep angles are varied from 0 deg to 75 deg and wing leading edge radii of 0.05 inch and 2.0 inches are examined. Structural temperatures are varied to allow comparison of aluminum alloy, titanium alloy, and superalloy structural materials. Cooled wing concepts are compared among themselves, and with the uncooled concept on the basis of structural weight, cooling system weight, and coolant weight.

Mcconarty, W. A.↗

Heat transfer distribution on a discontinuously convective cooled surface

An active cooling scheme in which discrete cooling passages are used was investigated. In this scheme, the coolant passages are placed perpendicular to the main stream direction. Streamwise temperature oscillations result from the highly cooled regions, near the coolant channels, being next to regions not directly cooled between the channels. The accuracy of the heat transfer rate predictions by these approximations was evaluated by means of both experimental and numerical investigations. Experiments were conducted at free stream Mach number of 6 with several cooling passages. Heat transfer measurements were made and corresponding theoretical analysis were performed for comparison in evaluating both local and overall deviations in the heat transfer rate.

Piva, R.↗

Simultaneous film and convection cooling of a plate inserted in the exhaust stream of a gas turbine combustor

Data were obtained on a parallel-flow film- and convection-cooled test section placed in the exhaust stream of a rectangular-sector combustor. The combustor was operated at atmospheric pressure and at exhaust temperatures of 589 and 1033 K (600 and 1400 F). The cooling air was at ambient pressure and temperature. Test results indicate that it is better to use combined film and convection cooling rather than either film or convection cooling alone for a fixed total coolant flow. An optimum ratio of film to convection cooling flow rates was determined for the particular geometry tested. The experimental results compared well with calculated results.

Marek, C. J.↗

A study of the thermoregulatory characteristics of a liquid-cooled garment with automatic temperature control based on sweat rate: Experimental investigation and biothermal man-model development

Experimental results for three subjects walking on a treadmill at exercise rates of up to 590 watts showed that thermal comfort could be maintained in a liquid cooled garment by using an automatic temperature controller based on sweat rate. The addition of head- and neck-cooling to an Apollo type liquid cooled garment increased its effectiveness and resulted in greater subjective comfort. The biothermal model of man developed in the second portion of the study utilized heat rates and exchange coefficients based on the experimental data, and included the cooling provisions of a liquid-cooled garment with automatic temperature control based on sweat rate. Simulation results were good approximations of the experimental results.

Chambers, A. B.↗

Film cooling in a combustor operating at fuel-rich exit conditions

Data were taken with a film-cooled test plate placed in the exhaust stream of a rectangular combustor. Results showed that in a fuel-rich zone, fuel entrained into the film-cooling air would burn at the conditions tested. Test conditions were cooling-gas flow rates, 9.5 and 5 percent of total gas flow; cooling-gas velocities, 23 and 12 m/sec; ambient-temperature cooling gas; hot-gas velocity, nominally 215 m/sec; fuel-air ratio to stoichiometric fuel-air ratio values of 0.1, 0.8, 1.0, 1.2, and 1.35, resulting in hot-gas temperatures from 590 to 2100 K; and atmospheric pressure. Analytical prediction of wall temperatures agreed reasonably well with experimental results.

Tacina, R. R.↗

Solar energy to heat and cool a new NASA Langley office building

A solar heating and cooling system will be installed at a new NASA office building. The objective of this project is to establish a full-scale working test-bed facility to investigate solar energy for heating and cooling buildings. The energy collected will provide between 80 and 100 percent of the heating and cooling requirements during the cool months and between one-half and two-thirds of the cooling requirements in the summer. Thermal energy storage will be provided to bridge the gap between cloudy and clear days.

Maag, W. L.↗

Subscale, hydrogen-burning, airframe-integrated-scramjet: Experimental and theoretical evaluation of a water cooled strut airframe-integrated-scramjet: Experimental leading edge

A water-cooled leading-edge design for an engine/airframe integrated scramjet model strut leading edge was evaluated. The cooling design employs a copper cooling tube brazed just downstream of the leading edge of a wedge-shaped strut which is constructed of oxygen-free copper. The survival of the strut leading edge during a series of tests at stagnation point heating rates confirms the practicality of the cooling design. A finite difference thermal model of the strut was also proven valid by the reasonable agreement of calculated and measured values of surface temperature and cooling-water heat transfer.

Pinckney, S. Z.↗

Industrial and biomedical use of aerospace personal cooling garments

Liquid-cooled garments (LCG) have been developed which utilize liquid-cooled modules rather than the network of tygon tubing typical of Apollo LCG's. The ultra-thin, heat-sealed, polyurethane modules are situated over the body to cover 50 percent of the body surface area with special emphasis on the 'working' muscles and the head-neck area. These garments are being designed specifically for industrial and biomedical uses, such as: a head-neck cooling system which is being tested for race-car drivers, tractor drivers, truck drivers, or a head-neck cooling system tested for the reduction of the scalp hair loss which normally accompanies cancer treatments. A combined head-neck and thorax unit is being developed for use during mine distaster rescue operations, and for other hazardous hot applications. Finally applications for head-neck and partitional cooling are anticipated for military pilots, tank drivers, and heavy equipment operations.

Williams, B. A.↗

Heat-Transfer Characteristics of Partially Film Cooled Plug Nozzle on a J-85 Afterburning Turbojet Engine

Plug nozzle film cooling data were obtained downstream of a slot located at 42 percent of the total plug length on a J-85 engine. Film cooling reduced the aft end wall temperature as much as 150 K, reduced total pressure loss in the upstream convection cooling passages by 50 percent, and reduced estimated compressor bleed flow requirement by 14 percent compared to an all convectively cooled nozzle. Shock waves along the plug surface strongly influenced temperature distributions on both convection and film cooled portions. The effect was most severe at nozzle pressure ratios below 10 where adverse pressure gradients were most severe.

Nosek, S. M.↗