Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Converting from DDOR SASF to APF

A computer program called ddor_sasf2apf converts delta-door (delta differential one-way range) request from an SASF (spacecraft activity sequence file) format to an APF (apgen plan file) format for use in the Mars Reconnaissance Orbiter (MRO) missionplanning- and-sequencing process. The APF is used as an input to APGEN/AUTOGEN in the MRO activity- planning and command-sequencegenerating process to sequence the delta-door (DDOR) activity. The DDOR activity is a spacecraft tracking technique for determining spacecraft location. The input to ddor_sasf2apf is an input request SASF provided by an observation team that utilizes DDOR. ddor_sasf2apf parses this DDOR SASF input, rearranging parameters and reformatting the request to produce an APF file for use in AUTOGEN and/or APGEN. The benefit afforded by ddor_sasf2apf is to enable the use of the DDOR SASF file earlier in the planning stage of the command-sequence-generating process and to produce sequences, optimized for DDOR operations, that are more accurate and more robust than would otherwise be possible.

Gladden, Roy E.↗

Converting EOS Data from HDF-EOS to netCDF

A C-language computer program accepts, as input, a set of scientific data and metadata from an Earth Observing System (EOS) satellite and converts the set from (1) the format in which it was created and delivered to (2) another format for processing and exchange of data on Earth.

Ullman, Richard↗

Thermoelectric Converter for Loop Heat Pipe Temperature Control: Experience and Lessons Learned

This paper describes the theoretical background and implementation methodology of using a thermoelectric converter (TEC) for operating temperature control of a loop heat pipe (LHP). In particular, experimental results from ambient and thermal vacuum tests of an LHP are presented for illustrations. The most commonly used state-of-the-art method to control the LHP operating temperature is to cold bias its compensation chamber (CC) and use an electrical heater to maintain the CC at the desired set point temperature. Although effective, this approach has its shortcomings in that the electrical heater can only provide heating to the CC, and the required power can be large under certain conditions. An alternative method is to use a TEC, which is capable of providing both heating and cooling to the CC. In this method, one side of the TEC is attached to the CC, and the other side is connected to the evaporator via a thermal strap. Using a bipolar power supply and a control algorithm, a TEC can function as a heater or a cooler, depending on the direction of the current flow. Extensive ground tests of several LHPs have demonstrated that a TEC can provide very tight temperature control for the CC. It also offers several additional advantages: (1) The LHP can operate at temperatures below its natural operating temperature at low heat loads; (2) The required heater power for a TEC is much less than that for an electrical heater; and (3) It enhances the LHP start-up success. Although the concept of using a TEC for LHP temperature control is simple, there are many factors to be considered in its implementation for space applications because the TEC is susceptible to the shear stress and yet has to sustain the dynamic load under the spacecraft launch environment. The added features that help the TEC to withstand the dynamic load will inevitably affect the TEC thermal performance. Some experiences and lessons learned are addressed in this paper.

Ku, Jentung↗

Converting a C-130 Hercules into a Compound Helicopter: A Conceptual Design Study

This study presents the performance and weight changes for a Compound C-130 as compared to the Baseline C-130H Hercules, using NDARC as the primary analysis tool. First, the C-130H was modeled within NDARC, from which performance at various conditions and a parametric weight statement were generated. Then, the C-130H NDARC file was modified to represent the Compound C-130, which was then put through the same performance analysis as the C-130H. A parametric weight statement was also calculated for the Compound C-130, which allowed for comparison to the C-130H. As part of the modeling of the Compound C-130, a Rotor Design Spreadsheet was created that would allow the direct calculation of the weight of the main rotors being added. Using composite materials led to considerable weight savings for both the rotor system and the hub weights. These weight savings are reflected in the NDARC Technology Factors which were determined to be 0.71 and 0.5 for the rotor blades and the hub/hinge system, respectively. Such Technology Factors suggest that using composites for other components could drastically lighten the Operating Empty Weight of the aircraft. The weight statements show the weights for each of the components on each aircraft. It is quite evident that the Compound C-130 has a higher Operating Empty Weight due to the addition of the two main rotors and a drive system to connect each engine group on the wing tips. Upon further analysis, the main weight driver is the drive system. While the main rotor/hub/hinge weight increase is to be expected, the weight increase due to the transmission drive and gear boxes are cause for concern. Unless a method can be found of reducing the weight of the drive system, the weight penalty makes the Compound a C-130 an inefficient aircraft in terms of payload/fuel capacity. Possible solutions are either off-loading some of the power requirements through the drive system or using composite materials in the construction of the drive system. The performance of the Compound C-130 versus the C-130H shows a clear need for more powerful engines than are currently present on the C-130H. This would also adversely affect the Operating Empty Weight since a larger power plant requires more weight. However, one advantage that the Compound C-130 presents is the ability to hover and operate at low speeds in Helicopter Mode. While the C-130H is unable to travel at speeds lower than its stall speed, the Compound C-130 is able to hover using the main rotors. Thus, the Compound C-130 is able to operate independent of runways, let alone the condition of the nearest runway. Ultimately, the Compound C-130 is an effective aircraft in theaters requiring VTOL aircraft due to geographical considerations in terms or performance. Unfortunately, the weight penalty associated with converting the C-130H to a Compound C-130 suggests that further work in the area of the drive systems is required.

Kottapalli, Anjaney P.↗

Full-Circle Resolver-to-Linear-Analog Converter

A circuit generates sinusoidal excitation signals for a shaft-angle resolver and, like the arctangent circuit described in the preceding article, generates an analog voltage proportional to the shaft angle. The disadvantages of the circuit described in the preceding article arise from the fact that it must be made from precise analog subcircuits, including a functional block capable of implementing some trigonometric identities; this circuitry tends to be expensive, sensitive to noise, and susceptible to errors caused by temperature-induced drifts and imprecise matching of gains and phases. These disadvantages are overcome by the design of the present circuit. The present circuit (see figure) includes an excitation circuit, which generates signals Ksin(Omega(t)) and Kcos(Omega(t)) [where K is an amplitude, Omega denotes 2(pi)x a carrier frequency (the design value of which is 10 kHz), and t denotes time]. These signals are applied to the excitation terminals of a shaft-angle resolver, causing the resolver to put out signals C sin(Omega(t)-Theta) and C cos(Omega(t)-Theta). The cosine excitation signal and the cosine resolver output signal are processed through inverting comparator circuits, which are configured to function as inverting squarers, to obtain logic-level or square-wave signals .-LL[cos(Omega(t)] and -LL[cos(Omega(t)-Theta)], respectively. These signals are fed as inputs to a block containing digital logic circuits that effectively measure the phase difference (which equals Theta between the two logic-level signals). The output of this block is a pulse-width-modulated signal, PWM(Theta), the time-averaged value of which ranges from 0 to 5 VDC as Theta ranges from .180 to +180deg. PWM(Theta) is fed to a block of amplifying and level-shifting circuitry, which converts the input PWM waveform to an output waveform that switches between precise reference voltage levels of +10 and -10 V. This waveform is processed by a two-pole, low-pass filter, which removes the carrier-frequency component. The final output signal is a DC potential, proportional to Theta that ranges continuously from -10 V at Theta = -180deg to +10 V at Theta = +180deg..

Alhorn, Dean C.↗

Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly done by cold biasing the reservoir and using electrical heaters to provide the required control power. With this method, the loop operating temperature can be controlled within 0.5K or better. However, because the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if the LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP was carried out to investigate the effects on the LHP operation when the control temperature sensor was placed on the heat source instead of the reservoir. In these tests, the LHP reservoir was cold-biased and was heated by a control heater. Test results show that it was feasible to use the heat source temperature for feedback control of the LHP operation. In particular, when a thermoelectric converter was used as the reservoir control heater, the heat source temperature could be maintained within a tight range using a proportional-integral-derivative or on/off control algorithm. Moreover, because the TEC could provide both heating and cooling to the reservoir, temperature oscillations during fast transients such as loop startup could be eliminated or substantially reduced when compared to using an electrical heater as the control heater.

Ku, Jentung↗

Frequency to Voltage Converter Analog Front-End Prototype

The frequency to voltage converter analog front end evaluation prototype (F2V AFE) is an evaluation board designed for comparison of different methods of accurately extracting the frequency of a sinusoidal input signal. A configurable input stage is routed to one or several of five separate, configurable filtering circuits, and then to a configurable output stage. Amplifier selection and gain, filter corner frequencies, and comparator hysteresis and voltage reference are all easily configurable through the use of jumpers and potentiometers.

Mata, Carlos↗

High fidelity, radiation tolerant analog-to-digital converters

Techniques for an analog-to-digital converter (ADC) using pipeline architecture includes a linearization technique for a spurious-free dynamic range (SFDR) over 80 deciBels. In some embodiments, sampling rates exceed a megahertz. According to a second approach, a switched-capacitor circuit is configured for correct operation in a high radiation environment. In one embodiment, the combination yields high fidelity ADC (>88 deciBel SFDR) while sampling at 5 megahertz sampling rates and consuming <60 milliWatts. Furthermore, even though it is manufactured in a commercial 0.25-.mu.m CMOS technology (1 .mu.m=12.sup.-6 meters), it maintains this performance in harsh radiation environments. Specifically, the stated performance is sustained through a highest tested 2 megarad(Si) total dose, and the ADC displays no latchup up to a highest tested linear energy transfer of 63 million electron Volts square centimeters per milligram at elevated temperature (131 degrees C.) and supply (2.7 Volts, versus 2.5 Volts nominal).

Wang, Charles Chang-I↗

670-GHz Down- and Up-Converting HEMT-Based Mixers

A large category of scientific investigation takes advantage of the interactions of signals in the frequency range from 300 to 1,000 GHz and higher. This includes astronomy and atmospheric science, where spectral observations in this frequency range give information about molecular abundances, pressures, and temperatures of small-sized molecules such as water. Additionally, there is a minimum in the atmospheric absorption at around 670 GHz that makes this frequency useful for terrestrial imaging, radar, and possibly communications purposes. This is because 670 GHz is a good compromise for imaging and radar applications between spatial resolution (for a given antenna size) that favors higher frequencies, and atmospheric losses that favor lower frequencies. A similar trade-off applies to communications link budgets: higher frequencies allow smaller antennas, but incur a higher loss. All of these applications usually require converting the RF (radio frequency) signal at 670 GHz to a lower IF (intermediate frequency) for processing. Further, transmitting for communication and radar generally requires up-conversion from IF to the RF. The current state-of-the-art device for performing the frequency conversion is based on Schottky diode mixers for both up and down conversion in this frequency range for room-temperature operation. Devices that can operate at room temperature are generally required for terrestrial, military, and planetary applications that cannot tolerate the mass, bulk, and power consumption of cryogenic cooling. The technology has recently advanced to the point that amplifiers in the region up to nearly 1,000 GHz are feasible. Almost all of these have been based on indium phosphide pseudomorphic high-electron mobility transistors (pHEMTs), in the form of monolithic microwave integrated circuits (MMICs). Since the processing of HEMT amplifiers is quite differ en t from that of Schottky diodes, use of Schottky mixers requires separate MMICs for the mixers and amplifiers. Fabrication of all the down-/up-conversion circuitry on single MMICs, using a ll-HEMT circuits, would constitute a major advance in circuit simplicity.

Schlecht, Enrich T.↗

Trash to Gas: Converting Space Waste into Useful Supply Products

The cost of sending mass into space with current propulsion technology is very expensive, making every item a crucial element of the space mission. It is essential that all materials be used to their fullest potential. Items like food, packaging, clothing, paper towels, gloves, etc., normally become trash and take up space after use. These waste materials are currently either burned up upon reentry in earth's atmosphere or sent on cargo return vehicles back to earth: a very wasteful method. The purpose of this project was to utilize these materials and create useful products like water and methane gas, which is used for rocket fuel, to further supply a deep space mission. The system used was a thermal degradation reactor with the configuration of a down-draft gasifier. The reactor was loaded with approximately 100g of trash simulant and heated with two external ceramic heaters with separate temperature control in order to create pyrolysis and gasification in one zone and incineration iri a second zone simultaneously. Trash was loaded into the top half of the reactor to undergo pyrolysis while the downdraft gas experienced gasification or incineration to treat tars and maximize the production of carbon dioxide. Minor products included carbon monoxide, methane, and other hydrocarbons. The carbon dioxide produced can be sent to a Sabatier reactor to convert the gas into methane, which can be used as rocket propellant. In order to maximize the carbon dioxide and useful gases produced, and minimize the unwanted tars and leftover ashen material, multiple experiments were performed with altered parameters such as differing temperatures, flow rates, and location of inlet air flow. According to the data received from these experiments, the process will be further scaled up and optimized to ultimately create a system that reduces trash buildup while at the same time providing enough useful gases to potentially fill a methane tank that could fuel a lunar ascent vehicle or other deep space mission.

Tsoras, Alexandra↗

A Particle-in-Cell Simulation for the Traveling Wave Direct Energy Converter (TWDEC) for Fusion Propulsion

A Particle-in-cell simulation model has been developed to study the physics of the Traveling Wave Direct Energy Converter (TWDEC) applied to the conversion of charged fusion products into electricity. In this model the availability of a beam of collimated fusion products is assumed; the simulation is focused on the conversion of the beam kinetic energy into alternating current (AC) electric power. The model is electrostatic, as the electro-dynamics of the relatively slow ions can be treated in the quasistatic approximation. A two-dimensional, axisymmetric (radial-axial coordinates) geometry is considered. Ion beam particles are injected on one end and travel along the axis through ring-shaped electrodes with externally applied time-varying voltages, thus modulating the beam by forming a sinusoidal pattern in the beam density. Further downstream, the modulated beam passes through another set of ring electrodes, now electrically oating. The modulated beam induces a time alternating potential di erence between adjacent electrodes. Power can be drawn from the electrodes by connecting a resistive load. As energy is dissipated in the load, a corresponding drop in beam energy is measured. The simulation encapsulates the TWDEC process by reproducing the time-dependent transfer of energy and the particle deceleration due to the electric eld phase time variations.

Chap, Andrew↗

Catalytic Converters Maintain Air Quality in Mines

At Langley Research Center, engineers developed a tin-oxide based washcoat to prevent oxygen buildup in carbon dioxide lasers used to detect wind shears. Airflow Catalyst Systems Inc. of Rochester, New York, licensed the technology and then adapted the washcoat for use as a catalytic converter to treat the exhaust from diesel mining equipment.

Source record↗

Lightweight, Efficient Power Converters for Advanced Turboelectric Aircraft Propulsion Systems

NASA is investigating advanced turboelectric aircraft propulsion systems that use superconducting motors to drive multiple distributed turbofans. Conventional electric motors are too large and heavy to be practical for this application; therefore, superconducting motors are required. In order to improve aircraft maneuverability, variable-speed power converters are required to throttle power to the turbofans. The low operating temperature and the need for lightweight components that place a minimum of additional heat load on the refrigeration system open the possibility of incorporating extremely efficient cryogenic power conversion technology. This Phase II project is developing critical components required to meet these goals.

Hennessy, Michael J.↗

Progress Towards the Development of a Traveling Wave Direct Energy Converter for Aneutronic Fusion Propulsion Applications

A coordinated experimental and theory/simulation effort has been carried out to investigate the physics of the Traveling Wave Direct Energy Converter (TWDEC), a scheme that has been proposed in the past for the direct conversion into electricity of the kinetic energy of an ion beam generated from fusion reactions. This effort has been focused in particular on the TWDEC process in the high density beam regime, thus accounting for the ion beam expansion due to its space charge.

Tarditi, A. G.↗

SEE Transient Response of Crane Interpoint Single Output Point of Load DC-DC Converters

This study was undertaken to determine the single event effect and transient susceptibility of the Crane Interpoint Maximum Flexible Power (MFP) Single Output Point of Load DC/DC Converters for transient interruptions in the output signal and for destructive and non destructive events induced by exposing it to a heavy ion beam..

Sanders, Anthony B.↗

Application of Low-Cost Fine Particulate Mass Monitors to Convert Satellite Aerosol Optical Depth Measurements to Surface Concentrations in North America and Africa

Low-cost particulate mass sensors provide opportunities to assess air quality at unprecedented spatial and temporal resolutions. Established traditional monitoring networks have limited spatial resolution and are simply absent in many major cities across sub-Saharan Africa (SSA). Satellites provide snapshots of regional air pollution but require ground-truthing. Low-cost monitors can supplement and extend data coverage from these sources worldwide, providing a better overall air quality picture. We investigate the utility of such a multi-source data integration approach using two case studies. First, in Pittsburgh, Pennsylvania, both traditional monitoring and dense low-cost sensor networks are compared with satellite aerosol optical depth (AOD) data from NASA's MODIS system, and a linear conversion factor is developed to convert AOD to surface fine particulate matter mass concentration (as PM2.5). With 10 or more ground monitors in Pittsburgh, there is a 2-fold reduction in surface PM2.5 estimation mean absolute error compared to using only a single ground monitor. Second, we assess the ability of combined regional-scale satellite retrievals and local-scale low-cost sensor measurements to improve surface PM2.5 estimation at several urban sites in SSA. In Rwanda, we find that combining local ground monitoring information with satellite data provides a 40 % improvement in surface PM2.5 estimation accuracy with respect to using low-cost ground monitoring data alone. A linear AOD-to-surface-PM2.5 conversion factor developed in Kigali, Rwanda, did not generalize well to other parts of SSA and varied seasonally for the same location, emphasizing the need for ongoing and localized ground-based monitoring, which can be facilitated by low-cost sensors. Overall, we find that combining ground-based low-cost sensor and satellite data, even without including additional meteorological or land use information, can improve and expand spatiotemporal air quality data coverage, especially in data-sparse regions.

AOD↗

SEE Test Report for Texas Instruments TLV5618 2.7-V to 5.5-V Low-Power Dual 12-Bit Digital-to-Analog Converter with Power Down

The primary purpose of this testing was to characterize the Texas Instruments TLV5618 12-bit digital-to-analog converter (DAC) for single-event latchup (SEL) susceptibility. These data will be used to assess the SEL risk for the OSIRIS-REx Laser Altimeter (OLA). A secondary goal is to assess the susceptibility of the DAC to single-event transients (SET), single-event upsets (SEU), and other nondestructive SEE.

Raymond Ladbury↗