Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Tailoring tokamak error fields to control plasma instabilities and transport

A tokamak relies on the axisymmetric magnetic fields to confine fusion plasmas and aims to deliver sustainable and clean energy. However, misalignments arise inevitably in the tokamak construction, leading to small asymmetries in the magnetic field known as error fields (EFs). The EFs have been a major concern in the tokamak approaches because small EFs, even less than 0.1%, can drive a plasma disruption. Meanwhile, the EFs in the tokamak can be favorably used for controlling plasma instabilities, such as edge-localized modes (ELMs). Here we show an optimization that tailors the EFs to maintain an edge 3D response for ELM control with a minimized core 3D response to avoid plasma disruption and unnecessary confinement degradation. We design and demonstrate such an edge-localized 3D response in the KSTAR facility, benefiting from its unique flexibility to change many degrees of freedom in the 3D coil space for the various fusion plasma regimes. This favorable control of the tokamak EF represents a notable advance for designing intrinsically 3D tokamaks to optimize stability and confinement for next-step fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of reduced neoclassical energy transport in Wendelstein 7-X

Research on magnetic confinement of high-temperature plasmas has the ultimate goal of harnessing nuclear fusion for the production of electricity. Although the tokamak is the leading toroidal magnetic-confinement concept, it is not without shortcomings and the fusion community has therefore also pursued alternative concepts such as the stellarator. Unlike axisymmetric tokamaks, stellarators possess a three-dimensional (3D) magnetic field geometry. The availability of this additional dimension opens up an extensive configuration space for computational optimization of both the field geometry itself and the current-carrying coils that produce it. Such an optimization was undertaken in designing Wendelstein 7-X (W7-X), a large helical-axis advanced stellarator (HELIAS), which began operation in 2015 at Greifswald, Germany. A major drawback of 3D magnetic field geometry, however, is that it introduces a strong temperature dependence into the stellarator’s non-turbulent ‘neoclassical’ energy transport. Indeed, such energy losses will become prohibitive in high-temperature reactor plasmas unless a strong reduction of the geometrical factor associated with this transport can be achieved; such a reduction was therefore a principal goal of the design of W7-X. In spite of the modest heating power currently available, W7-X has already been able to achieve high-temperature plasma conditions during its 2017 and 2018 experimental campaigns, producing record values of the fusion triple product for such stellarator plasmas. The triple product of plasma density, ion temperature and energy confinement time is used in fusion research as a figure of merit, as it must attain a certain threshold value before net-energy-producing operation of a reactor becomes possible. Here we demonstrate that such record values provide evidence for reduced neoclassical energy transport in W7-X, as the plasma profiles that produced these results could not have been obtained in stellarators lacking a comparably high level of neoclassical optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated optical frequency division for microwave and mmWave generation

Abstract The generation of ultra-low-noise microwave and mmWave in miniaturized, chip-based platforms can transform communication, radar and sensing systems 1–3 . Optical frequency division that leverages optical references and optical frequency combs has emerged as a powerful technique to generate microwaves with superior spectral purity than any other approaches 4–7 . Here we demonstrate a miniaturized optical frequency division system that can potentially transfer the approach to a complementary metal-oxide-semiconductor-compatible integrated photonic platform. Phase stability is provided by a large mode volume, planar-waveguide-based optical reference coil cavity 8,9 and is divided down from optical to mmWave frequency by using soliton microcombs generated in a waveguide-coupled microresonator 10–12 . Besides achieving record-low phase noise for integrated photonic mmWave oscillators, these devices can be heterogeneously integrated with semiconductor lasers, amplifiers and photodiodes, holding the potential of large-volume, low-cost manufacturing for fundamental and mass-market applications 13 .

Science & Technology - Other Topics↗

A magnetic sensor using a 2D van der Waals ferromagnetic material

Two-dimensional (2D) van der Waals ferromagnetic materials are emerging as promising candidates for applications in ultra-compact spintronic nanodevices, nanosensors, and information storage. Our recent discovery of the strong room temperature ferromagnetism in single layers of VSe2 grown on graphite or MoS2 substrate has opened new opportunities to explore these ultrathin magnets for such applications. In this paper, we present a new type of magnetic sensor that utilizes the single layer VSe2 film as a highly sensitive magnetic core. The sensor relies in changes in resonance frequency of the LC circuit composed of a soft ferromagnetic microwire coil that contains the ferromagnetic VSe2 film subject to applied DC magnetic fields. We define sensitivity as the slope of the characteristic curve of our sensor, df0/dH, where f0 is the resonance frequency and H is the external magnetic field. The sensitivity of the sensor reaches a large value of 16×106Hz/Oe, making it a potential candidate for a wide range of magnetic sensing applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

Current distribution monitoring enables quench and damage detection in superconducting fusion magnets

Abstract Fusion magnets made from high temperature superconducting ReBCO CORC ® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC ® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC ® cables for compact fusion reactors.

47 OTHER INSTRUMENTATION↗

Foldable semi-ladder polymers: novel aggregation behavior and high-performance solution-processed organic light-emitting transistors

A critical issue in developing high-performance organic light-emitting transistors (OLETs) is to balance the trade-off between charge transport and light emission in a semiconducting material. Although traditional materials for organic light-emitting diodes (OLEDs) or organic field-effect transistors (OFETs) have shown modest performance in OLET devices, design strategies towards high-performance OLET materials and the crucial structure–performance relationship remain unclear. Our research effort in developing cross-conjugated weak acceptor-weak donor copolymers for luminescent properties lead us to an unintentional discovery that these copolymers form coiled foldamers with intramolecular H-aggregation, leading to their exceptional OLET properties. An impressive external quantum efficiency (EQE) of 6.9% in solution-processed multi-layer OLET devices was achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sequence-defined structural transitions by calcium-responsive proteins

Biopolymer sequences dictate their functions, and protein-based polymers are a promising platform to establish sequence–function relationships for novel biopolymers. To efficiently explore vast sequence spaces of natural proteins, sequence repetition is a common strategy to tune and amplify specific functions. This strategy is applied to repeats-in-toxin (RTX) proteins with calcium-responsive folding behavior, which stems from tandem repeats of the nonapeptide GGXGXDXUX in which X can be any amino acid and U is a hydrophobic amino acid. To determine the functional range of this nonapeptide, we modified a naturally occurring RTX protein that forms β-roll structures in the presence of calcium. Sequence modifications focused on calcium-binding turns within the repetitive region, including either global substitution of nonconserved residues or complete replacement with tandem repeats of a consensus nonapeptide GGAGXDTLY. Some sequence modifications disrupted the typical transition from intrinsically disordered random coils to folded β rolls, despite conservation of the underlying nonapeptide sequence. Proteins enriched with smaller, hydrophobic amino acids adopted secondary structures in the absence of calcium and underwent structural rearrangements in calcium-rich environments. In contrast, proteins with bulkier, hydrophilic amino acids maintained intrinsic disorder in the absence of calcium. In conclusion, these results indicate a significant role of nonconserved amino acids in calcium-responsive folding, thereby revealing a strategy to leverage sequences in the design of tunable, calcium-responsive biopolymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solubilization of PET in binary mixtures of HFIP and DCM

The dissolution of polyethylene terephthalate (PET) is a critical step for a solvent-based process, yet it typically requires highly corrosive or toxic solvents. Here, we investigate the solubilization and conformational behavior of PET in binary mixtures of hexafluoro-2-propanol (HFIP) and dichloromethane (DCM) as a strategy to reduce HFIP usage while maintaining effective dissolution. Small-angle neutron scattering (SANS) measurements reveal that PET remains molecularly dissolved in HFIP/DCM mixtures up to 50 vol% DCM. Analysis of PET chain conformations shows a transition from Gaussian behavior at low HFIP fractions to more swollen chains at intermediate compositions, accompanied by a counter-intuitive minimum in the radius of gyration at 50% HFIP. Complementary SANS measurements of the binary solvents demonstrate that compositional heterogeneity is maximized at this same solvent composition, suggesting a direct coupling between solvent microstructure and polymer dimensions. Molecular dynamics simulations corroborate the experimental findings, revealing solvent domain formation, preferential solvation of PET by HFIP, and a “caging” effect arising from solvent heterogeneity that leads to polymer coil compaction. Together, these results provide molecular-level insight into polymer behavior in mixed solvent systems and establish HFIP/DCM mixtures as a promising, more sustainable solvent platform for the PET post-process.

Arifuzzaman, Arif [ORNL]↗

Experimental system for studying temperature gradient-driven fracture of oxide nuclear fuel out of reactor

Temperature gradients in ceramic light water reactor (LWR) uranium dioxide (UO 2 ) nuclear fuel pellets generate thermal stresses that cause fractures in the fuel beginning early in the life of fresh fuel. The combination of heating due to fission and forced convective cooling on the exterior of LWR fuel rods generates a temperature profile that is difficult to replicate outside the reactor environment. In the present study, a state-of-the-art experimental set-up using electrical heating to replicate fission heating was built and surrogate fuel materials such as ceria (CeO 2 ) were used to validate the system. Cracking experiments were conducted on these surrogates by inducing reactivity-initiated-accident (RIA) like temperature gradients in the pellets via induction and direct resistance heating. Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was used by a D.C. power supply to introduce volumetric heating to replicate LWR operating conditions analogous to fission heating. The pellets were held against nickel electrodes and mounted on a boron nitride test-stand. All the tests were carried out in a stainless-steel vacuum chamber. Simultaneous real-time dual imaging of the surrogate pellet surface has been implemented using an optical and infrared camera system which will be mounted along axial and perpendicular directions to the pellet surface respectively. A beam-splitter was used to split the incoming radiation from the sample into two halves. While one of the beams is transmitted from the splitter through a bandpass filter to obtain optical images, the other beam is reflected from the splitter to the thermal camera to capture full field temperature gradients of the as fabricated pellet surface during crack initiation and propagation. In the current series of tests, a 2-color pyrometer was used for recording and comparing the surface and centerline temperatures of the surrogate pellets in lieu of the thermal camera. A LabVIEW data acquisition system has been set up for collecting useful data during experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Net energy gain in direct laser acceleration due to enhanced dephasing induced by an applied magnetic field

Even in the situation where an electron interacts with a single plane wave, the well-known dynamical adiabaticity can be broken when an applied magnetic field is present, which will act to increase the dephasing rate of the electron during the interaction. Here we demonstrate this for the case where there is a uniform static magnetic field which is oriented either parallel or perpendicular to the electric field of the incident plane wave, and perpendicular to the direction of its propagation. The described energy gain phenomenon has direct relevance to laser-plasma interactions that involve external magnetic fields generated by laser-driven capacitor coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of magnetic field error in ExtendedEBIS

The upgrade of the EBIS, called ExtendedEBIS, is now in progress in Brookhaven National Laboratory. Two 5T-superconducting solenoids have been placed in series with 200 mm distance from each other for higher trap capacity and production of polarized 3He ions. Since the two superconducting solenoids are used, the field error is expected to be larger. In this research, the field error is estimated based on simulation. It was found that the magnetic field line can be 17 mm off from the center axis at the entrance of the collector, and this offset can be adjusted by three types of correction coils. Additionally, mismatch of the spin direction of polarized 3He due to the misalignment was estimated to be small.

Ikeda, Shunsuke (ORCID:0000000339800577)↗

Z-pinch fusion

The Z-pinch configuration offers the promise of a compact fusion device owing to its simple geometry, unity beta, and absence of external magnetic field coils. Increasing the axial current compresses the plasma, resulting in a rapid rise of the fusion reaction rate. Historically, the Z pinch has been plagued by fast growing instabilities that limit plasma lifetimes. Recent progress has resulted from investigating approaches that provide stability. One approach exploits sheared-flow stabilization to produce an equilibrium Z pinch, which sustains the compressed plasma state for durations much longer than other plasma timescales. Recent experimental and simulation results encourage pursuit of the stabilized Z pinch to explore its fusion performance limits.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positron orbit effects during injection and confinement in a magnetic dipole trap

Lossless injection of positrons into a magnetic dipole trap and their subsequent confinement have been demonstrated. Here, we investigate by numerical single-particle simulations how the radial distribution of positrons in the trap is affected by the measurement itself, the choice of injection parameters, the asymmetry of the electric potential, and by elastic collisions. The results are compared to experimental data. A comprehensive understanding of these effects is a milestone on the road to creating an electron–positron plasma in a trap with a levitating superconducting coil.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A tungsten external heater for BX90 diamond anvil cells with a range up to 1700 K

Resistive heating of a sample in a diamond anvil cell (DAC) can generate a homogeneous temperature field across the sample chamber with reliable temperatures measured by a thermocouple. It is of importance in experiments aiming at exploring phase diagrams and quantifying thermoelastic properties of materials. Here, we present a ring-heater design developed for BX90 diamond anvil cells (DACs). Furthermore, it is made of a ring-shaped aluminum oxide holder hosting a tungsten wire coil inside and coupled with Ar + 2% H 2 gas to prevent oxidation during experiment. This modular plug-and-play design enables in situ studies of samples via x-ray diffraction up to a temperature of 1700 K. Temperature in the BX90 sample volume as measured through a thermocouple was calibrated using the melting point of gold. As an application of this design, we report the thermal expansion coefficient of MgO at 9.5(1) GPa.

47 OTHER INSTRUMENTATION↗

An improved theory of the response of DIII-D H-mode discharges to static resonant magnetic perturbations and its implications for the suppression of edge localized modes

The plasma response to an externally generated, static, n = 2, resonant magnetic perturbation (RMP) in the pedestal region of DIII-D H-mode discharge #158115 is investigated using a toroidal generalization of the asymptotic matching model presented by Fitzpatrick [Phys. Plasmas 27, 042506 (2020)]. Just as in a recent paper [Q. M. Hu et al., Phys. Plasmas 26, 120702 (2019)], it is hypothesized that the density pump-out phenomenon is due to locked magnetic island chains induced at the bottom of the pedestal, whereas the suppression of edge localized modes is associated with a locked magnetic island chain induced at the top of the pedestal. Neutral penetration inside the last closed magnetic flux-surface is found to have a significant influence on locked magnetic island chain formation at the bottom of the pedestal. It is found that locked island formation at the top of the pedestal is only possible when q95 lies in certain narrow windows. Finally, it is inferred that, in order to successfully induce a locked island chain at the top of the pedestal, an external RMP field-coil system must generate a magnetic field that is simultaneously strongly amplified by the plasma (via the ideal kink response) and has a large resonant component at a rational surface that lies close to the top of the pedestal.

Fitzpatrick, R. (ORCID:0000000162379309)↗

Parallel high-frequency magnetic sensing with an array of flux transformers and multi-channel optically pumped magnetometer for hand MRI application

Here, we investigate an approach for parallel high-frequency magnetic sensing based on a multi-channel radio frequency (RF) optically pumped magnetometer (OPM) coupled to multiple flux transformers (FTs) with a focus on hand magnetic resonance imaging (MRI) application at ultra-low field (ULF). Multiple RF OPM sensing channels are realized by using a single large-area alkali-metal vapor cell and two laser beams for pumping and probing, shared for all the channels. This design leads to significant cost reduction when multi-channel sensing is desirable, as in the case of ULF MRI. The FT, composed of two connected coils, serves as a transmitter of a target magnetic field to the OPM, while decoupling the OPM from untargeted magnetic fields in the sensing area that can limit the OPM performance. For hand MRI application, theoretical and numerical analysis is performed to determine an optimal geometry for the FT array that could improve signal-to-noise ratio (SNR) and sufficiently reduce crosstalk between FTs. We estimate that the optimized multi-channel FT-OPM sensor can achieve a magnetic field sensitivity of the order of 1 fT / Hz 1 / 2 above 100 kHz, which would be sufficient for 1 mm resolution MRI. In general, the multi-channel capability enables simultaneous magnetic measurements, thus reducing the sensing time and improving the SNR, and we anticipate many applications of the multi-channel FT-OPM sensor beyond the targeted here hand MRI: anatomical parallel ULF MRI of the human brain and other parts of the body, airport security screening, magnetic material imaging, and many others.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of magnetic noise from conductive shields in the 10–300 kHz frequency range

Here we present experimental and theoretical investigations of magnetic noise originating from radio-frequency (RF) conductive shields of flat geometry in the inductance-dominated impedance regime below 300 kHz. The measurement is based on a Q-factor determination of a coil that provides a sufficient sensitivity, placed at the position where the shield magnetic noise is measured. The theory is based on calculations of magnetic field and inductance of one or a few flat rings that emulate a conductive shield. The theoretical model is found to be in close agreement with experimental data. It can be used to predict the magnetic noise of a conductive shield with different thicknesses, conductivities, and temperatures at different distances for a wide range of frequencies. Although the model can be generalized for a more arbitrary shield geometry, in its presented form, it can be applied to the magnetic noise predictions when the shield surface curvature is not large. One important conclusion is that the RF conductive shield can generate the magnetic noise much lower than femtotesla, and, thus, it can be used in many precision experiments targeting minute high-frequency magnetic signals, such as detection of magnetic resonance imaging and nuclear quadrupole resonance signals and search for axion dark matter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗