Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Simulation of Charge Collection to Spacecraft Surfaces: Freja Satellite

As spacecraft travel through space plasma, spacecraft surfaces become charged by the collection of charged particles. This process is referred to as Surface Charging. These charges can be detrimental to the vehicle's electronic subsystems as they present a threat of electrostatic discharge (ESD) to onboard circuitry. The process of Surface Charging is complex and is affected by many elements. The charging of each surface is unique. The potential of an individual surface is dependent upon many variables including but not limited to the surface's geometry, material and its location. Each surface also has unique interactions with the surrounding plasma. Other factors that play large roles in the charging process is the density and temperature of plasma ions and electrons. Using Nascap-2k, a model of the Freja satellite has been constructed, and its auroral plasma environment has been imitated to simulate surface charging characteristics. The charging process of the Freja satellite has been modeled iteratively with incremental changes in both the Maxwellian electron temperature (eV) as well as the Gaussian electron energy (eV). This study provides an analysis of the sensitivity between spacecraft surface charging and these two primary variables of electron differential flux.

Wolfley, Olivia Hope↗

Impact of Charge Degradation on the Life Cycle Climate Performance of a Residential Air-Conditioning System

Vapor compression systems continuously leak a small fraction of their refrigerant charge to the environment, whether during operation or servicing. As a result of the slow leak rate occurring during operation, the refrigerant charge decreases until the system is serviced and recharged. This charge degradation, after a certain limit, begins to have a detrimental effect on system capacity, energy consumption, and coefficient of performance (COP). This paper presents a literature review and a summary of previous experimental work on the effect of undercharging or charge degradation of different vapor compression systems, especially those without a receiver. These systems include residential air conditioning and heat pump systems utilizing different components and refrigerants, and water chiller systems. Most of these studies show similar trends for the effect of charge degradation on system performance. However, it is found that although much experimental work exists on the effect of charge degradation on system performance, no correlation or comparison between charge degradation and system performance yet exists. Thus, based on the literature review, three different correlations that characterize the effect of charge on system capacity and energy consumption are developed for different systems as follows: one for air-conditioning systems, one for vapor compression water-to-water chiller systems, and one for heat pumps. These correlations can be implemented in vapor compression cycle simulation tools to obtain a better prediction of the system performance throughout its lifetime. In this paper, these correlations are implemented in an open source tool for life cycle climate performance (LCCP) based design of vapor compression systems. The LCCP of a residential air-source heat pump is evaluated using the tool and the effect of charge degradation on the results is studied. The heat pump is simulated using a validated component-based vapor compression system model and the LCCP results obtained using the three charge degradation correlations are compared.

Air Conditioning↗

Electrostatic charge buildup and electrostatic discharge monitoring system and method

A system for monitoring electrostatic charge buildup and electrostatic discharge (ESD) remotely comprises a plurality of electrostatic charge measurement units and a data acquisition device. Each electrostatic charge measurement unit includes a primary charge plate, a static sensor device, a secondary charge plate, and a shielded cable. The primary charge plate is positioned proximal to an object. The static sensor device includes an input sensor at which an electric voltage is measured and outputs an electronic signal whose level varies according to the measured electric voltage. The secondary charge plate is positioned in proximity to the input sensor of the static sensor device. The shielded cable includes an inner conductor electrically connected to the primary charge plate and the secondary charge plate and an outer conductor electrically connected to electrical ground. The data acquisition device receives the electronic signal from the static sensor device of each electrostatic charge measurement unit.

Schantz, Eric T.↗

Charging of Proteins in Native Mass Spectrometry

Factors that influence the charging of protein ions formed by electrospray ionization from aqueous solutions in which proteins have native structures and function were investigated. Protein ions ranging in molecular weight from 12.3 to 79.7 kDa and pI values from 5.4 to 9.6 were formed from different solutions and reacted with volatile bases of gas-phase basicities higher than that of ammonia in the cell of a Fourier-transform ion cyclotron resonance mass spectrometer. The charge-state distribution of cytochrome c ions formed from aqueous ammonium or potassium acetate is the same. Moreover, ions formed from these two solutions do not undergo proton transfer to 2-fluoropyridine, which is 8 kcal/mol more basic than ammonia. These results provide compelling evidence that proton transfer between ammonia and protein ions does not limit protein ion charge in native electrospray ionization. Both circular dichroism and ion mobility measurements indicate that there are differences in conformations of proteins in pure water and aqueous ammonium acetate, and these differences can account for the difference in the extent of charging and proton-transfer reactivities of protein ions formed from these solutions. The extent of proton transfer of the protein ions with higher gas-phase basicity bases trends with how closely the protein ions are charged to the value predicted by the Rayleigh limit for spherical water droplets approximately the same size as the proteins. These results indicate that droplet charge limits protein ion charge in native mass spectrometry and are consistent with these ions being formed by the charged residue mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System dynamic model and charging control of lead-acid battery for stand-alone solar PV system

The lead-acid battery which is widely used in stand-alone solar system is easily damaged by a poor charging control which causes overcharging. The battery charging control is thus usually designed to stop charging after the overcharge point. This will reduce the storage energy capacity and reduce the service time in electricity supply. The design of charging control system however requires a good understanding of the system dynamic behaviour of the battery first. In the present study, a first-order system dynamics model of lead-acid battery at different operating points near the overcharge voltage was derived experimentally, from which a charging control system based on PI algorithm was developed using PWM charging technique. The feedback control system for battery charging after the overcharge point (14 V) was designed to compromise between the set-point response and the disturbance rejection. The experimental results show that the control system can suppress the battery voltage overshoot within 0.1 V when the solar irradiation is suddenly changed from 337 to 843 W/m{sup 2}. A long-term outdoor test for a solar LED lighting system shows that the battery voltage never exceeded 14.1 V for the set point 14 V and the control system can prevent the battery from overcharging. The test result also indicates that the control system is able to increase the charged energy by 78%, as compared to the case that the charging stops after the overcharge point (14 V). (author)

14 SOLAR ENERGY↗

Charge resolved electrostatic diagnostic of colliding copper laser plasma plumes

The collision of two laser generated plasma plumes can result, under appropriate conditions, in the formation of a ''stagnation layer.'' The processes underlying this phenomenon are complex and time dependent. The majority of experiments over the last few decades have focused upon spectroscopic diagnostic of colliding plasmas. We have performed electrostatic diagnosis of multiply charged copper ions (Cu{sup +} to Cu{sup 5+}) generated via Q-switched pulsed laser ({lambda} = 1.06 {mu}m, {tau} = 6 ns, and E{sub L} = 52-525 mJ) generation of copper plasma plumes from a planar target. Time dependent current traces, charge yields, and kinetic energy (K{sub e}) distributions are obtained for single plasma plumes (S{sub p}) and colliding plasma plumes (C{sub p}). The charge yield from a C{sub p} relative to twice that from a S{sub p} is characterized by a charge yield ratio (CYR) parameter. Superior ion yields for all charge states occur for a discrete range of fluences (F) from colliding plasma plumes leading to a CYR parameter exceeding unity. The kinetic energy distributions from colliding plasma plumes display well defined energy compression via narrowing of the distributions for all fluences and charge states. The extent of this energy compression is charge dependent. Space charge forces within the stagnation layer and the resulting charge dependent acceleration of ions are proposed to account for the transfer of ion kinetic energy in favour of collisional ionization mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of a direct current field on the microparticle charge in the plasma afterglow

Residual charges of individual microparticles forming dense clouds were measured in a RF discharge afterglow. Experiments were performed under microgravity conditions on board the International Space Station, which ensured particle levitation inside the gas volume after the plasma switch-off. The distribution of residual charges as well as the spatial distribution of charged particles across the cloud were analyzed by applying a low-frequency voltage to the electrodes and measuring amplitudes of the resulting particle oscillations. Upon “free decharging” conditions, the charge distribution had a sharp peak at zero and was rather symmetric (with charges concentrated between −10e and +10e), yet positively and negatively charged particles were homogeneously distributed over the cloud. However, when decharging evolved in the presence of an external DC field (applied shortly before the plasma switch-off) practically all residual charges were positive. In this case, the overall charge distribution had a sharp peak at about +15e and was highly asymmetric, while the spatial distribution exhibited a significant charge gradient along the direction of the applied DC field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge density stabilised local electron spin pair states in insulating polymers

A model is presented that addresses the energy stability of localized electron states in insulating polymers with respect to delocalized free electron-like states at variable charge densities. The model was derived using an effective Hamiltonian for the total energy of electrons trapped in large polarons and spin-paired bipolarons, which includes the electrostatic interaction between charges that occurs when the charge density exceeds the infinite dilution limit. The phase diagram of the various electronic states with respect to the charge density is derived using parameters determined from experimental data for polyethylene, and it is found that a phase transition from excess charge in the form of stable polarons to a stable state of bipolarons with charge = 2 and spin number S = 0 is predicted for a charge density between 0.2 C/m{sup 3} and ∼2 C/m{sup 3}. This transition is consistent with a change from low mobility charge transport to charge transport in the form of pulses with a mobility orders of magnitude higher that has been observed in several insulating polymers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strategies for Enhancing Battery Life Under Fast Charging: Insights from NMC-Based Cell Cycling

Fast charging improves the usability of consumer electronics and electric vehicles (EVs) by reducing range anxiety and downtime but accelerates battery degradation and raises safety concerns. Optimizing operational conditions during fast-charging is critical to mitigating aging and ensuring safety. This study evaluated multilayer Gr/NMC811 cells under various conditions, including depths of discharge (DODs of 68%, 84%, and 100%), upper charge cutoff voltages (4.1–4.2 V), and post-charge rest periods (2–30 min), using a 20 min fast charging protocol for up to 500 cycles (up to 150,000 miles of EV use assuming 3.3 mi/kWh vehicle level energy efficiency). Surprisingly, higher DODs under fast charging improved battery life and performance compared to lower DODs. Reducing the upper charge cut-off voltage helped mitigate degradation. A brief 2 min rest period after charging further reduced aging effects. The primary aging modes were loss of lithium inventory and cathode active material. Although minor lithium plating was observed within 500 cycles, it did not affect performance significantly. These findings suggest that, with optimized conditions, cells can sustain hundreds of fast charge cycles—equivalent to over 100,000 miles of EV use—without significant adverse effects on performance or longevity.

25 - ENERGY STORAGE↗

Understanding EV Charging Pain Points Through Deep Learning Analysis

Current and potential electric vehicle (EV) owners express concerns about the charging infrastructure, mentioning non-functional chargers, prolonged charging times, inconvenient charger locations, long wait times, and high costs as major barriers. Addressing these issues often requires analyzing actual vehicle charging data, which is typically proprietary and inconsistent due to diverse standards and protocols. To understand and improve the EV charging experience, customer reviews are typically used to identify common customer pain points (CPPs). However, there is not a comprehensive method to map customer reviews to a standardized set of CPPs. In collaboration with the National Charging Experience (ChargeX) Consortium, this study bridges these gaps by proposing a Systematic Categorization and Analysis of Large-scale EV-charging Reviews (SCALER) framework. SCALER is an integrated, deep learning framework that segments, actively labels, analyzes, and classifies EV charging customer reviews into six CPP categories. To test its effectiveness, we used SCALER to analyze over 72,000 reviews from customers charging various EV models on different networks across the United States. SCALER achieves a classification accuracy of 92.5%, with an F1 score exceeding 85.7%. By demonstrating real-world applications of SCALER, we enhance the industry’s ability to understand and address CPPs to improve the EV charging experience.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

National parks in the Western United States draw over 80 million visitors every year, and most visitors rely on personal cars for their road trips (or long-distance travels). Travel to national parks represents distinct travel demand, as they are typically located in remote areas necessitating long-distance trips. This study investigates the quantity and locations of on-route fast charging infrastructure needed by 2030 to enable seamless travel to/from national parks using electric vehicles in seven target states in the region, employing unprecedented high-resolution spatial and temporal analysis. We find that the required number of fast charging ports for on-route charging infrastructure ranges from 1,200 to 22,000, depending on different assumptions of key input parameters - vehicle electrification rate, charging behavior, average gap between charging stations, port utilization rate, and towing trailers. Our analysis also indicates that electrical load for on-route fast charging infrastructure would peak in the afternoon, in the range of 70-400 MW, varying with the key input parameters. This study illustrates how different input parameters result in different degrees of impact on various aspects of charging infrastructure. We also examine the characteristics of projected charging infrastructure in terms of land use type, relationship with traffic volume, size of stations, and other variables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capacitive Deionization Using Alternating Polarization: Effect of Surface Charge on Salt Removal

Alternating polarization (AP) at ±1.2/0 V is performed on a capacitive deionization stack assembled with carbon xerogel (CX) electrodes. Long-term testing shows enhanced cycling stability without the formation of inversion peaks. AP also leads to an arch-shaped plot of salt adsorption capacity (SAC) versus cycling time, with the highest SAC of approximately 3 mg (NaCl) g −1 (CX) during this long-term test. Characterization of both the freshly prepared and cycled electrodes depict that AP results in surface charge of all the electrodes being modified from positive to negative character. Here by leveraging balances of electronic, surface, and ionic charges in carbon micropores, it is found that a portion of the electronic charge contributes to the ionic charge for salt adsorption, and another portion is parasitically consumed to balance the surface charge during the charge reconciliation process. When the consumption of electronic charge for charge reconciliation becomes minimal, both the positive and negative surface charges are nearly equivalent on the CX electrode. Under such a condition, the highest SAC values can be achieved for AP testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The need for ion-exchange membranes with high charge densities

Ion-exchange membranes (IEMs) are essential for controlling ion transport in electrochemical membrane-based technologies for water purification, energy generation, and energy storage. In general, IEMs must exhibit high ionic conductivity and selectivity, both of which are significantly influenced by the charge and water content of the hydrated membrane. In this perspective, we compiled the charge and water contents of approximately 1,000 IEMs reported over the past several decades to assess their range and variability, as well as to reveal gaps and set clear targets for future membrane design. We compared the charge and water content of negatively and positively charged membranes, as well as membranes developed for desalination and energy applications. The majority of IEMs, regardless of structure or intended application, have volumetric charge densities below 3 mol/L[membrane]. This narrow range of charge densities limits the performance of IEMs and contributes to the observed tradeoff between ion throughput and selectivity. It is critical to develop IEMs with higher charge densities to overcome this performance limitation. Further, we highlighted several design strategies that yielded IEMs with fixed charge densities higher than 3 mol/L[membrane]. These strategies provide valuable insights and can guide the design of next-generation IEMs with high charge densities.

36 MATERIALS SCIENCE↗

Charge Transport in Zirconium-Based Metal–Organic Frameworks

Metal–organic frameworks (MOFs) are a class of crystalline porous materials characterized by inorganic nodes and multitopic organic linkers. Because of their molecular-scale porosity and periodic intraframework chemical functionality, MOFs are attractive scaffolds for supporting and/or organizing catalysts, photocatalysts, chemical-sensing elements, small enzymes, and numerous other functional-property-imparting, nanometer-scale objects. Notably, these objects can be installed after the synthesis of the MOF, eliminating the need for chemical and thermal compatibility of the objects with the synthesis milieu. Thus, postsynthetically functionalized MOFs can present three-dimensional arrays of high-density, yet well-separated, active sites. Depending on the application and corresponding morphological requirements, MOF materials can be prepared in thin-film form, pelletized form, isolated single-crystal form, polycrystalline powder form, mixed-matrix membrane form, or other forms. For certain applications, most obviously catalytic hydrolysis and electro- or photocatalytic water splitting, but also many others, an additional requirement is water stability. MOFs featuring hexa-zirconium(IV)-oxy nodes satisfy this requirement. For applications involving electrocatalysis, charge storage, photoelectrochemical energy conversion, and chemiresistive sensing, a further requirement is electrical conductivity, as embodied in electron or hole transport. As most MOFs, under most conditions, are electrically insulating, imparting controllable charge-transport behavior is both a chemically intriguing and chemically compelling challenge. Herein, we describe three strategies to render zirconium-based metal–organic frameworks (MOFs) tunably electrically conductive and, therefore, capable of transporting charge on the few nanometers (i.e., several molecular units) to few micrometers (i.e., typical dimensions for MOF microcrystallites) scale. The first strategy centers on redox-hopping between periodically arranged, chemically equivalent sites, essentially repetitive electron (or hole) self-exchange. Zirconium nodes are electrically insulating, but they can function as grafting sites for (a) redox-active inorganic clusters or (b) molecular redox couples. Alternatively, charge hopping based on linker redox properties can be exploited. Marcus’s theory of electron transfer has proven useful for understanding/predicting trends in redox-hopping based conductivity, most notably, in accounting for variations as great as 3000-fold depending on the direction of charge propagation through structurally anisotropic MOFs. In MOF environments, propagation of electronic charge via redox hopping is necessarily accompanied by movement of charge-compensating ions. Consequently, rates of redox hopping can depend on both the identity and concentration of ions permeating the MOF. In the context of electrocatalysis, an important goal is to transport electronic charge fast enough to match or exceed the inherent activity of MOF-based or MOF-immobilized catalysts. Bandlike electronic conductivity is the focus of an alternative strategy: one based on the introduction of molecular guests capable of forming donor–acceptor charge transfer complexes with the host framework. Theory again can be applied predictively to alter conductivity. A third strategy similarly emphasizes electronic conductivity, but it makes use of added bridges in the form of molecular oligomers or inorganic clusters that can then be linked to span the length of a MOF crystallite. For all strategies, retention of molecular-scale porosity is emphasized, as this property is key to many applications. Lastly, while our focus is on Zr-MOFs, the described approaches clearly are extendable to other MOF compositions, as has already been demonstrated, in part, in studies by others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wall-loss distribution of charge breeding ions in an electron cyclotron resonance ion source

The ion loss distribution in an electron cyclotron resonance ion source (ECRIS) was investigated to understand the element dependence of the charge breeding efficiency in an electron cyclotron resonance (ECR) charge breeder. The radioactive {sup 111}In{sup 1+} and {sup 140}Xe{sup 1+} ions (typical nonvolatile and volatile elements, respectively) were injected into the ECR charge breeder at the Tokai Radioactive Ion Accelerator Complex to breed their charge states. Their respective residual activities on the sidewall of the cylindrical plasma chamber of the source were measured after charge breeding as functions of the azimuthal angle and longitudinal position and two-dimensional distributions of ions lost during charge breeding in the ECRIS were obtained. These distributions had different azimuthal symmetries. The origins of these different azimuthal symmetries are qualitatively discussed by analyzing the differences and similarities in the observed wall-loss patterns. The implications for improving the charge breeding efficiencies of nonvolatile elements in ECR charge breeders are described. The similarities represent universal ion loss characteristics in an ECR charge breeder, which are different from the loss patterns of electrons on the ECRIS wall.

43 PARTICLE ACCELERATORS↗

The ReA electron-beam ion trap charge breeder for reacceleration of rare isotopes

ReA is a post-accelerator at the National Superconducting Cyclotron Laboratory at Michigan State University. ReA is designed to reaccelerate rare isotopes to energies of a few MeV/u following production by projectile fragmentation and thermalization in a gas cell. The facility consists of four main components: an electron-beam ion trap (EBIT) charge breeder, an achromatic charge-over-mass (Q/A) separator, a radio-frequency quadrupole accelerator, and a superconducting radio-frequency linear accelerator. The EBIT charge breeder was specifically designed to efficiently capture continuous beams of singly charged ions injected at low energy (<60 keV), charge breed in less than 50 ms, and extract highly charged ions to the Q/A separator for charge-state selection and reacceleration through the accelerator structures. The use of highly charged ions to reach high beam energies is a key aspect that makes ReA a compact and cost-efficient post-accelerator. The EBIT is characterized by a high-current electron gun, a long multi-electrode trap structure and a dual magnet to provide both the high electron-beam current density necessary for fast charge breeding of short-lived isotopes as well as the high capture probability of injected beams. This paper presents an overview and the status of the ReA EBIT, which has extracted for reacceleration tests stable {sup 20}Ne{sup 8+} ion beams produced from injected gas and more recently {sup 39}K{sup 16+} beams by injecting stable {sup 39,41}K{sup +} ions from an external ion source.

43 PARTICLE ACCELERATORS↗

Negative differential mobility for negative carriers as revealed by space charge measurements on crosslinked polyethylene insulated model cables

Among features observed in polyethylene materials under relatively high field, space charge packets, consisting in a pulse of net charge that remains in the form of a pulse as it crosses the insulation, are repeatedly observed but without complete theory explaining their formation and propagation. Positive charge packets are more often reported, and the models based on negative differential mobility(NDM) for the transport of holes could account for some charge packets phenomenology. Conversely, NDM for electrons transport has never been reported so far. The present contribution reports space charge measurements by pulsed electroacoustic method on miniature cables that are model of HVDC cables. The measurements were realized at room temperature or with a temperature gradient of 10 °C through the insulation under DC fields on the order 30–60 kV/mm. Space charge results reveal systematic occurrence of a negative front of charges generated at the inner electrode that moves toward the outer electrode at the beginning of the polarization step. It is observed that the transit time of the front of negative charge increases, and therefore the mobility decreases, with the applied voltage. Further, the estimated mobility, in the range 10{sup −14}–10{sup −13} m{sup 2} V{sup −1} s{sup −1} for the present results, increases when the temperature increases for the same condition of applied voltage. The features substantiate the hypothesis of negative differential mobility used for modelling space charge packets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High spatial resolution charge sensing of quantum Hall states

Charge distribution offers a unique fingerprint of important properties of electronic systems, including dielectric response, charge ordering, and charge fractionalization. Here, we develop an architecture for charge sensing in two-dimensional electronic systems in a strong magnetic field. We probe local change of the chemical potential in a proximitized detector layer using scanning tunneling microscopy, allowing us to infer the chemical potential and the charge profile in the sample. Our technique has both high energy (<0.3 meV) and spatial (<10 nm) resolution exceeding that of previous studies by an order of magnitude. We apply our technique to study the chemical potential of quantum Hall liquids in monolayer graphene under high magnetic fields and their responses to charge impurities. The chemical potential measurement provides a local probe of the thermodynamic gap of quantum Hall ferromagnets and fractional quantum Hall states. The screening charge profile reveals spatially oscillatory response of the quantum Hall liquids to charge impurities and is consistent with the composite Fermi liquid picture close to the half-filling. Our technique also paves the way to map moiré potentials, probe Wigner crystals, and investigate fractional charges in quantum Hall and Chern insulators.

charge sensing↗