At least 1,225 records · Page 68

CRADA Number NFE-19-07846 with Grid Fruit, LLC (CRADA Final Report)

Cooperative Research and Development Agreement (CRADA) NFE-19-07846 between Oak Ridge National Laboratory (ORNL) and Grid Fruit, LLC (Grid Fruit) focused on simulating, monitoring, and adjusting controls of commercial refrigerator and freezer systems to provide load flexibility and demand response services from these machines. Viewing these medium and low-temp coolers as thermal masses, the volumes of chilled air in these coolers make them time-shiftable loads ripe for deployment at optimal times. Grid Fruit is a startup company developing methods to schedule the chilling cycles (e.g., in “build load” and “shed load” grid events) to provide energy efficiency, peak shifting, and other benefits both to the grid and the broader environment. These benefits can be magnified by coordinating chillers with HVAC, lights, computers, and other loads. Grid Fruit completed simulations and then selected and ordered controls hardware to prove the technology were successful, but the diversity of chiller models in the field without digital controls, as well as limited market demand at present, make further exploration necessary before commercialization.

42 ENGINEERING↗

Demand Response in Industrial Facilities: Peak Electric Demand

The US Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) is a voluntary energy efficiency leadership initiative for US manufacturers and water/wastewater entities. The program encourages organizations to commit to reducing the energy intensity of their US operations over a 10-year period, typically by 25%. Companies joining Better Plants are recognized by DOE for their leadership in implementing energy efficiency practices and for reducing their energy intensity. Better Plants Partners are assigned to a Technical Account Manager, who can help companies establish energy intensity baselines, develop energy management plans, and identify key resources and incentives from DOE, other federal agencies, states, utilities, and other organizations that can enable them to reach their goals. Better Plants Partners are expected to report their progress to DOE once a year. This involves establishing an energy intensity baseline upon joining the program and then tracking their progress over time. Demand Response in Industrial Facilities: Peak Electrical Demand is intended to help companies understand peak demand response programs offering by their local utility. Manufacturing industries can learn about time-varying rates and smart technologies they can use to help them reduce their energy bills. This guidance document is applicable to companies participating at either the program or challenge level. Although this guide is intended primarily to assist companies participating in Better Plants, the methodologies and guidance within the document are applicable to any organization interested in understanding peak demand response programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equitable Electrification Analysis for Existing Buildings in Richmond, CA [Slides]

Since June 2022, NREL has provided technical assistance in the form of research and analysis in order to support the City of Richmond in identifying strategies to equitably transition its existing buildings from reliance on natural gas to clean electricity. Building on data from the ResStock and ComStock tools, the analysis looked at the potential impacts of building envelope and electrification improvements on energy consumption and greenhouse gas emissions, residential utility bills, jobs and employment, and indoor air quality. This presentation summarizes the findings from that research and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Communities LEAP Pilot Residential Housing Analysis - Detailed Methodology

This methodology document supports residential building analysis for some communities receiving technical assistance through the Department of Energy Communities LEAP (Local Energy Action Program). Communities LEAP supports community-wide economic and environmental benefits through technical assistance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A VECTOR ANALYTICAL FRAMEWORK FOR POPULATION MODELING

We propose a vector alternative to the typical raster based population modeling framework. When compared with rasters, vectors are more precise, have the ability to hold more information, and are more conducive to areal constructs such as building and parcel outlines. While rasters have traditionally provided computational efficiency, much of this efficiency is reduced at finer resolutions and computational resources are more plentiful today. Herein we describe the approach and implementation methodology. We also describe the output data stack for the United States and provide examples and applications.

Moehl, Jessica↗

Energy conservation, using remote thermal scanning

Airborne thermal infrared scans and thermal maps utilized in NASA's energy conservation program have proven to be efficient cost-effective method for identifying heat losses from building roofs and heating system distribution lines. Method employs commercially available equipment in highly developed way.

Bowman, R. L.↗

Italian and French Experiments on Wind Tunnels

Given here are the results of experiments conducted by Colonel Costanzi of the Italian Army to determine the influence of the surrounding building in which a wind tunnel was installed on the efficiency of the installation, and how the efficiency of the installation was affected by the design of the tunnel. Also given are the results of a series of experiments by Eiffel on 34 models of tunnels of different dimensions. This series of experiments was started in order to find out if, by changing the shape of the nozzle or of the diffuser of the large tunnel at Auteuil, the efficiency of the installation could be improved.

Knight, WM↗

An authoring system for creating a practice environment in the network service field

This paper describes an authoring system whose main purpose is to reduce the cost of developing and maintaining courseware which contains procedural knowledge used in the network service field. This aim can be achieved by considering the characteristics of this field. Material knowledge is divided into two parts, behavioral knowledge and procedural knowledge. We show that both of these parts are constructed by an easy authoring methods and efficient modification algorithms. This authoring system has been used to build several types of courseware, and the development costs have been reduced.

Kiyama, Minoru↗

Submonolayer Quantum Dot Infrared Photodetector

A method has been developed for inserting submonolayer (SML) quantum dots (QDs) or SML QD stacks, instead of conventional Stranski-Krastanov (S-K) QDs, into the active region of intersubband photodetectors. A typical configuration would be InAs SML QDs embedded in thin layers of GaAs, surrounded by AlGaAs barriers. Here, the GaAs and the AlGaAs have nearly the same lattice constant, while InAs has a larger lattice constant. In QD infrared photodetector, the important quantization directions are in the plane perpendicular to the normal incidence radiation. In-plane quantization is what enables the absorption of normal incidence radiation. The height of the S-K QD controls the positions of the quantized energy levels, but is not critically important to the desired normal incidence absorption properties. The SML QD or SML QD stack configurations give more control of the structure grown, retains normal incidence absorption properties, and decreases the strain build-up to allow thicker active layers for higher quantum efficiency.

Ting, David Z.↗

PRSEUS Pressure Cube Test Data and Response

NASA s Environmentally Responsible Aviation (ERA) Program is examining the hybrid wing body (HWB) aircraft, among others, in an effort to increase the fuel efficiency of commercial aircraft. The HWB design combines features of a flying wing with features of conventional transport aircraft, and has the advantage of simultaneously increasing both fuel efficiency and payload. Recent years have seen an increased focus on the structural performance of the HWB. The key structural challenge of a HWB airframe is the ability to create a cost and weight efficient, non-circular, pressurized shell. Conventional round fuselage sections react cabin pressure by hoop tension. However, the structural configuration of the HWB subjects the majority of the structural panels to bi-axial, in-plane loads in addition to the internal cabin pressure, which requires more thorough examination and analysis than conventional transport aircraft components having traditional and less complex load paths. To address this issue, while keeping structural weights low, extensive use of advanced composite materials is made. This report presents the test data and preliminary conclusions for a pressurized cube test article that utilizes Boeing's Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS), and which is part of the building block approach used for HWB development.

Lovejoy, Andrew E.↗

Multi-Angle Imager for Aerosols (MAIA) spectral and radiometric calibration

The Multi-angle Imaging SpectroRadiometer (MISR) was launched as part of NASA’s Terra satellite suite of instruments. Still operational, it makes use of observations from multiple view angles to retrieve aerosol abundance and particle properties. The Multi-Angle Imager for Aerosols (MAIA) instrument improves on this heritage by incorporating polarimetry and an expanded spectral range. Combining these data with surface measurements, the relationship between pollution and human health will be explored. MAIA has just completed camera testing, building on the experience from MISR. Spectral calibration now makes use of a double subtractive monochromator, built with the intent to allow the exit slit output to be uniform in spectral content. For radiometric testing, hardware upgrades have included adding UV lamps to the 1.65 cm (65") integrating sphere, use of a NIST-traceable sphere to establish absolute radiances, and the addition of a UV transfer spectrometer to support characterization of the sphere output from 300 to 2500 nm. During camera build, Newton’s rings were observed in the detector Quantum Efficiency (QE) measurements. This is due to etaloning within the detector itself. Etaloning was also evident in the spectral and radiometric characterizations performed on the completed camera. Spectral metrics, including center wavelength and width, are presented here using a moment’s analysis. This better represents the band properties, particularly in bands where fringing is observed, as compared to a full-width at half-maximum determination. It is believed that the MAIA camera has been carefully characterized, and meet its spectral and radiometric requirements.

Harten, Gerard Van↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Providence Performing Arts Center (PPAC): Energy Efficient Upgrades

The Energy Efficient Upgrades project at the Providence Performing Arts Center represents a significant investment in modernizing infrastructure, enhancing performance capabilities and improving visitor experience, all while promoting sustainability. The project’s primary goals included the installation of building-wide WIFI coverage, replacement of the outdated theatrical lighting system with energy-efficient alternatives, upgrades to the telephone systems and enhancements to the internal sound systems, both backstage and in the lobby.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Getting Beyond Widgets: Performance of Efficient Indoor Air Quality System Retrofit Packages for Schools A report on the modeled energy, greenhouse gas, and cost savings of several multi-measure retrofit packages for energy efficiency and indoor air quality in primary schools

School facilities are often underfunded with aging and poorly maintained HVAC and lighting systems. Most existing school buildings stand to benefit significantly from retrofits in terms of energy, cost, and emissions savings. Ventilation and indoor air quality (IAQ), which are important aspects of a healthy and productive learning environment, can also be enhanced by some energy efficiency measures (EEMs). Packaging energy efficiency and IAQ systems retrofits may represent a golden opportunity to improve performance in this critical building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Stirling Convertor Extended Operation Testing and Data Analysis at Glenn Research Center

Extended operation of Stirling convertors is essential to the development of radioisotope power systems and their potential use for longduration missions. To document the reliability of the convertors, regular monitoring and analysis of the extended operation data is particularly valuable, allowing us to better understand and quantify long-life characteristics of the convertors. Furthermore, investigation and comparison of the extended operation data to baseline performance data provides an opportunity to understand system behavior should any off-nominal performance occur. Glenn Research Center (GRC) has tested 16 Stirling convertors under 24-hr unattended extended operation, including four that have operated in a thermal vacuum environment and two that are operating in the Advanced Stirling Radioisotope Generator Engineering Unit. Ten of the sixteen convertors are the Advanced Stirling Convertors (ASC) developed by Sunpower, Inc. with GRC. These are highly efficient (conversion efficiency of up to 38 percent for the ASC-1), low-mass convertors that have evolved through technologically progressive convertor builds. Six convertors at GRC are Technology Demonstration Convertors from Infinia Corporation. They have achieved greater than 27 percent conversion efficiency and have accumulated over 185,000 of the total 265,000 hr of extended operation at GRC. This paper presents the extended operation testing and data analysis of free-piston Stirling convertors at NASA GRC as well as how these tests have contributed to the Stirling convertor s progression toward flight.

Cornell, Peggy A.↗

Literature Review for Sensor Impact Evaluation and Verification Use Cases - Building Controls and Fault Detection and Diagnosis (FDD)

This report summarizes a comprehensive literature review for the selected sensor suites used in building controls and fault detection and diagnostics (FDD), which is a Q2 deliverable of the Sensor Impact Evaluation and Verification project. The project’s overarching goal is to develop a framework for investigating the impact of sensor deployment and configuration for building energy optimization, fault detection and diagnosis (FDD), occupants’ thermal comfort, and potential grid efficiency. While the first phase of the literature review performed in Q1 reviewed the current methods of various sensor selection and placements and their impact, this report focuses on high impactful potential use cases for the selected sensor suites in building control and FDD. The use cases identified in this literature review will be further investigated and be included in the final sensor impact evaluation framework. For the review, the multi-laboratory team reviewed 241 research papers, technical reports, and books to identify existing technologies, the potential impact on energy savings and thermal comfort, and future research opportunities for the selected use cases in building controls and FDD. Along with the literature review, the team conducted a series of interviews with experts in sensors and controls area to identify the state-of-art sensor technologies, and the most impactful use cases in controls and FDD areas. The interview results will also be incorporated with the findings from the literature review in the next quarter, and the final use cases to be evaluated will be selected.

47 OTHER INSTRUMENTATION↗