Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Energy Efficiency Improvements to Wundar Hall, a Historic Building on the Concordia Campus, Milwaukee, Wisconsin

The Forest County Potawatomi Community (FCPC or Community) implemented energy efficiency improvements to revitalize Wundar Hall, a 34,000 square foot (SF) building that was formerly used as a dormitory and is listed on the National Registry of Historic Places, into an office building. Wundar Hall is the first of many architecturally and historically significant buildings that the Community hopes to renovate at the former Concordia College campus, property on the near west side of Milwaukee that was taken into trust for the Community by the United States on July 10, 1990 (collectively, the Concordia Trust Property). As part of this project, which was conducted with assistance from the Department of Energy's Tribal Energy Program (TEP), the Community updated and/or replaced the building envelope, mechanical systems, the plumbing system, the electrical infrastructure, and building control systems. The project is expected to reduce the building's natural gas consumption by 58% and the electricity consumption by 55%. In addition, the project was designed to act as a catalyst to further renovation of the Concordia Trust Property and the neighborhood. The City of Milwaukee has identified redevelopment of the Concordia Trust Property as a Catalytic Project for revitalizing the near west side. The Tribe envisions a revitalized, mixed-use campus of community services, education, and economic development—providing services to the Indian community and jobs to the neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Support Document: Development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings - 50% Energy Savings

This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-MBBR) ASHRAE et al. (2011b). The AEDG-MBBR is intended to provide recommendations for achieving 50% whole-building energy savings in retail stores over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-MBBR was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Monitoring and Analysis

This project aimed to develop a standard methodology for building energy data definition, collection, presentation, and analysis; apply the developed methods to a standardized energy monitoring platform, including hardware and software, to collect and analyze building energy use data; and compile offline statistical data and online real-time data in both countries for fully understanding the current status of building energy use. This helps decode the driving forces behind the discrepancy of building energy use between the two countries; identify gaps and deficiencies of current building energy monitoring, data collection, and analysis; and create knowledge and tools to collect and analyze good building energy data to provide valuable and actionable information for key stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Summary of Building Protection Factor Studies for External Exposure to Ionizing Radiation

Radiation dose assessments are used to help inform decisions to minimize health risks in the event of an atmospheric release of radioactivity including, for example, from a Radiological Dispersal Device, an Improvised Nuclear Device detonation, or a Nuclear Power Plant accident. During these incidents, radiation dose assessments for both indoor and outdoor populations are needed to make informed decisions. These dose assessments inform emergency plans and decisions including, for example, identifying areas in which people should be sheltered and determining when controlled population evacuations should be made. US dose assessment methodologies allow consideration of the protection, and therefore dose reduction, that buildings provide their occupants. However, these methodologies require an understanding of the protection provided by various building types that is currently lacking. To help address this need, Lawrence Livermore National Laboratory, in cooperation with Sandia National Laboratories and the Nuclear Regulatory Commission, was tasked with (a) identifying prior building protection studies, (b) extracting results relevant to US building construction, and (c) summarizing building protection by building type. This report focuses primarily on the protection against radiation from outdoor fallout particles (external gamma radiation).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

STTR Phase I: Low-Cost, High-Accuracy, Whole-Building Carbon Dioxide Monitoring for Demand Control Ventilation

This STTR Phase I project assessed the feasibility of a new CO 2 sensing system optimized for low-cost, high-accuracy, whole-building monitoring for use in demand control ventilation. The focus was on the development of a wireless networking platform and associated firmware to provide signal conditioning and conversion, fault- and disruptiontolerant networking, and multi-hop routing at building scales to avoid wiring costs. Early exploration of a bridge (or “gateway”) to direct digital control services was also explored. Results of the project contributed to an improved understanding of a new electrochemical sensor for monitoring indoor CO 2 concentrations, as well as the electronics and networking infrastructure required to deploy those sensors at building scales. New knowledge was acquired concerning the sensor’s accuracy, environmental response, and failure modes, and the acquisition electronics required to achieve accuracy over a wide range of CO 2 concentrations. The project demonstrated that the new sensor offers repeatable correspondence with commercial optical sensors, with supporting electronics that offer gain accuracy within 0.5%, and acquisition accuracy within 1.5% across three orders of magnitude variation in generated current. Considering production, installation, and maintenance costs, the technology presents a foundation for achieving whole-building CO 2 sensing at a price point below $0.066 / sq-ft – meeting economic feasibility criteria established by the Department of Energy. The technology developed under this award addresses obstacles on the critical path to enabling whole-building CO 2 sensing and demand control ventilation in commercial retrofits, small commercial buildings, residential complexes, and other highpotential structures that have been slow to adopt these technologies. It presents an opportunity to significantly reduce energy use throughout the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Health and Energy Efficiency in Multi-Family Buildings

The intersection between health and the built environment has long been known. Since the 18 th century, public health officials have been targeting building issues, such as crowding, poor sanitation, and inadequate ventilation in efforts to reduce infectious diseases and fire hazards. More recently, federal agencies, such as the U.S. Environmental Protection Agency (EPA), the Centers for Disease Control and Prevention, HUD, and the DOE have been working to reduce or eliminate indoor building factors that are known to have adverse health impacts on Americans, including reducing lead in housing and indoor air pollution that causes respiratory disease, and ensuring access to adequate heating, cooling, and moisture control. PNNL, in support of FEMP’s HBI, undertook a review of literature and existing best practices to identify current activities and research on the intersection between traditional energy-efficiency measures and occupant health within multi-family buildings. While the HBI methodology has focused on traditional office building spaces, it is now expanding into additional building use types. This overview explores some of the most impactful resources to help property owners and managers understand more about multi-family residential buildings that are both healthy and energy efficient. The federal government provides direct oversight and operation across several types of multi-family residential housing, including dormitories, barracks, and senior community living centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report Series: Finding of Effect and Mitigation Documentation for Building 23-W10, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

Finding of Effect: The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-W10 in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15228), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-W10, a supply warehouse, was installed in Mercury in 1962 (NNSS GIS Database) and served as a support facility for nuclear testing throughout much of the Cold War. It was likely produced during World War II (WWII) and previously installed at Camp Desert Rock. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource #D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-W10 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-W10 was also identified in Appendix C of the Mercury PA as a Category II contributing element. Category II properties are those that have several representatives in the MHD, such as warehouses, but may possess different engineering or architectural characteristics that distinguish them from other classes of similar elements. Building 23-W10 is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation: The purpose of this letter report is to support the mitigation of the demolition of Building 23-W10 (Nevada State Historic Preservation Office [SHPO] Resource No. B15228) in the Mercury Historic District (MHD, SHPO Resource #D230) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The warehouse is considered contributing to the significance of the district both for its historic importance in relation to nuclear testing under Criterion A and as a part of the distinctive design and construction of the district under Criterion C. This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Report Series: Finding of Effect and Mitigation Documentation for Building 23-153, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

Finding of Effect: The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-153, the Mechanical Calibration Laboratory (Calibration Lab), in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15271), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada. The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-153 was constructed in Mercury in 1982 as the Mechanical Calibration Laboratory and served as a support facility for nuclear testing throughout the last decade of the Cold War. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-153 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-153 was also identified in Appendix C of the Mercury PA as a Category II contributing element. Category II properties are those that have several representatives in the MHD but may possess different engineering or architectural characteristics that distinguish them from other classes of similar elements. Building 23-153 is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation: The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-153, the Mechanical Calibration Laboratory (Calibration Lab, Nevada State Historic Preservation Office [SHPO] Resource No. B15271), in the Mercury Historic District (MHD, SHPO Resource No. D230) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The Calibration Lab is considered contributing to the significance of the district both for its historic importance in relation to nuclear testing under Criterion A and as a part of the distinctive design and construction of the district under Criterion C. This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Building 23-620, Los Alamos Scientific Laboratory J-3 Office, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-620, the Los Alamos Scientific Laboratory (LASL) J-3 Office Building (Nevada State Historic Preservation Office [SHPO] Resource No. B15283) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The NNSA/NFO is implementing a long-term project to modernize the town of Mercury for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800. In 2018, Desert Research Institute (DRI) completed an architectural survey of the town of Mercury. This effort resulted in the identification, recordation, and evaluation of the Mercury Historic District (MHD, SHPO Resource No. D230), including the identification of its contributing elements (Reno et al. 2018). The MHD was recommended eligible for listing in the National Register of Historic Places (NRHP, National Register) under the Secretary of the Interior’s (SOI) Significance Criteria A and C, as defined in 36 CFR Part 60.4, as a significant concentration of buildings and structures with a direct and important association with Cold War-era nuclear testing from 1951 through 1992. It has not been evaluated under Criteria B and D to date. As part of a larger modernization program for Mercury, the NNSA/NFO and the SHPO executed the 2018 Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (Mercury PA). The Mercury PA includes streamlined Section 106 procedures for undertakings in the MHD based on contributing element categories. Building 23-620 is identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of Section 106 compliance and subject to the stipulations of the Mercury PA. Per Stipulation VI of the Mercury PA, when the Area of Potential Effect (APE) for an undertaking includes Category I elements, the NNSA/NFO must evaluate the Category I elements for individual NRHP eligibility under all of the SOI Significance Criteria prior to initiating any activity that may affect the elements. The purpose of this report is to evaluate Building 23-620 as a potential individually eligible historic property in fulfillment of Stipulation VI of the Mercury PA. The evaluation detailed herein concludes that Building 23-620 is not individually eligible for listing in the NRHP. Although it retains aspects of integrity and continues to contribute to the MHD, it is not individually significant under any of the SOI Significance Criteria.

54 ENVIRONMENTAL SCIENCES↗

Finding of Adverse Effect and Proposed Mitigation for the Demolition of Building 23-530, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-530 in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15270), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada. The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-530, a dormitory called Freedom Hall, was constructed in Mercury in 1982 and served as a support facility for nuclear testing for the last decade of the Cold War. The town of Mercury and the immediate surrounding area have been determined eligible for listing in the National Register of Historic Places (NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992 (Reed 2019). Building 23-530 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-530 was also identified in Appendix C of the Mercury PA as a Category II contributing element. Category II properties are those that have several representatives in the MHD but may possess different engineering or architectural characteristics that distinguish them from other classes of similar elements. Building 23-530 is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-530 (Nevada State Historic Preservation Office [SHPO] Resource No. B15270) in the Mercury Historic District (MHD, SHPO Resource No. D230) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The dormitory is considered contributing to the significance of the district both for its historic importance in relation to nuclear testing under Criterion A and as a part of the distinctive design and construction of the district under Criterion C. This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Equitable Strategies for Residential Building Energy Efficiency and Electrification in San José, California

Hotter summers, heat waves, wildfires, and droughts are already affecting San Jose residents, with historically marginalized communities impacted first and worst. The City of San Jose has ambitious goals to make the city climate-neutral by 2030 and serve as an example for cities to accelerate climate action around the world. Electrifying and decarbonizing residential buildings are important priorities to achieve San Jose's plans to reach carbon neutrality while enabling residents to live the "Good Life 2.0" - a vision that aligns with community-identified priorities of safety, health, freedom, community, and positive experiences. This technical assistance built upon the Electrify San Jose: Framework for Existing Building Electrification to identify actionable strategies to make single- and multi-family buildings both energy-efficient and all-electric. This report is intended to provide the San Jose Climate Smart team and their partners with relevant data, insights, and actionable analysis to aid in-depth and nuanced engagements with key stakeholders. In particular, the findings in this report highlight opportunities and challenges for San Jose City Council, residents, building owners, developers, financial institutions, and utility partners instrumental in building support and earning buy-in for energy efficiency and electrification upgrades in existing buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Equitable Strategies for Residential Building Energy Efficiency and Electrification in San José, California [Slides]

Hotter summers, heat waves, wildfires, and droughts are already affecting San Jose residents, with historically marginalized communities impacted first and worst. The City of San Jose has ambitious goals to make the city climate-neutral by 2030 and serve as an example for cities to accelerate climate action around the world. Electrifying and decarbonizing residential buildings are important priorities to achieve San Jose's plans to reach carbon neutrality while enabling residents to live the "Good Life 2.0" - a vision that aligns with community-identified priorities of safety, health, freedom, community, and positive experiences. This technical assistance built upon the Electrify San Jose: Framework for Existing Building Electrification to identify actionable strategies to make single- and multi-family buildings both energy-efficient and all-electric. This report is intended to provide the San Jose Climate Smart team and their partners with relevant data, insights, and actionable analysis to aid in-depth and nuanced engagements with key stakeholders. In particular, the findings in this report highlight opportunities and challenges for San Jose City Council, residents, building owners, developers, financial institutions, and utility partners instrumental in building support and earning buy-in for energy efficiency and electrification upgrades in existing buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of Model Building Energy Codes

The Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program. A 2016 study looked more broadly at overall code impacts and this report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced emissions at the state level and at aggregated levels. In 2021, DOE conducted an interim and limited update to its 2016 study to evaluate potential building code updates using the 2016 methodology. That interim update includes estimated savings resulting from updates to the model energy codes, including the ANSI/ASHRAE/IES Standard 90.1-2016 (ASHRAE 90.1-2016) and 2019 editions, as well as the 2018 and 2021 International Energy Conservation Code (IECC). In 2023, DOE developed a fully updated report that includes code updates (ASHRAE 90.1-2019 and 2021 IECC), as well as additional enhancements and updates, including updated energy prices, annual floorspace additions, state code adoption dates, and emission factors, among others. This current version is another fully updated report that includes code updates (ASHRAE 90.1-2022 and 2024 IECC), as well as additional enhancements and updates, including updated energy prices, state code adoption dates, emission factors, and renewable energy contribution among others. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when the new code is implemented and builders, architects, and engineers are required to comply with the new provisions. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. The contributions of all three phases are crucial to the overall impact of codes and are considered in this assessment. Figure ES.1 schematically describes the analysis framework. Energy savings are expressed in terms of energy use intensity (EUI) in the figure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine Learning Based Metamodel for Faster Life Cycle Assessment of Large Portfolio of Buildings

Managing a large portfolio of buildings involves decisions on reuse, retrofit, renovation, rehabilitation, and new construction, influenced by trade-offs between performance metrics such as cost, time, and operational flexibility over the building's life cycle. Traditional life cycle assessment tools for evaluating these metrics can be labor- and compute-intensive, requiring extensive data and modeling for each building. Metamodels (or surrogate models) using machine learning have been explored as faster alternatives, but training these models has been hindered by the limited availability of comprehensive data on key life cycle metrics. Recent advancements in machine learning, particularly deep learning techniques like zero-shot and few-shot learning, allow models to learn from sparse or limited data. We propose a machine learning-based metamodel that leverages these techniques for rapid estimation of key building life cycle metrics. This presentation will cover the model architecture, data collection, training, and validation processes, along with an ongoing case study applied to a large portfolio of buildings. We will discuss the model's performance in terms of accuracy, compute time, limitations, and its potential for expanding to additional life cycle metrics. This data-driven approach offers a promising direction for the rapid evaluation of large building portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Y-12 Sustainable Design Principles for Building Design and Construction

B&W Y-12 is committed to modernizing the Y-12 complex to meet future needs with a sustainable and responsive infrastructure and to integrating sustainability principles and practices into Y-12 work (Y72-001, B&W Y-12 Environmental, Safety and Health Policy). This commitment to sustainability and specifically sustainable design of buildings is also incorporated into Presidential Executive Orders (EO), DOE Orders (DOE O), and goals. Sustainable building design is an approach to design, construct, and operate facilities in an efficient and environmentally sound manner that will produce a healthful, resource-efficient and productive working environment that is inherently protective of the environment. The DOE has established the following 5 Guiding Principles for High Performance Sustainable Building (HPSB), and has issued directives that require Y-12 to incorporate the principles and a number of supporting specific practices and techniques into building design, construction and renovation projects: (1) Employ Integrated Design Principles; (2) Optimize Energy Performance; (3) Protect and Conserve Water; (4) Enhance Indoor Environmental Quality; and (5) Reduce Environmental Impact of Materials. The purpose of this document is to present the required sustainable building principles, practices and techniques, summarize the key drivers for incorporating them into Y-12 projects, and present additional recommendations and resources that can be used to support sustainable buildings to enhance the environmental and economic performance of the Y-12 Complex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Best Practices Series, Volume 9: Builders Challenge Guide to 40% Whole-House Energy Savings in the Hot-Dry and Mixed-Dry Climates

This best practices guide is the ninth in a series of guides for builders produced by the U.S. Department of Energy’s Building America Program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-dry and mixed-dry climates can achieve homes that have whole house energy savings of 40% over the Building America benchmark (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code) with no added overall costs for consumers. These best practices are based on the results of research and demonstration projects conducted by Building America’s research teams. The guide includes information for managers, designers, marketers, site supervisors, and subcontractors, as well as case studies of builders who are successfully building homes that cut energy use by 40% in the hot-dry and mixed-dry climates.

54 ENVIRONMENTAL SCIENCES↗

Identification Approach to Alleviate Effects of Unmeasured Heat Gains for MIMO Building Thermal Systems

It is important to have practical methods for constructing a good mathematical model for a building's thermal system for energy audits, retrofit analysis and advanced building controls, e.g. model predictive control. Identification approaches based on semi-physical model structures are popular in building science for those purposes. However conventional gray box identification approaches applied to thermal networks would fail when significant unmeasured heat gains present in estimation data. Although this situation is very common and practical, there has been little research to tackle this issue in building science. This paper presents an overall identification approach to alleviate influences of unmeasured disturbances, and hence to obtain improved gray-box building models. The approach was applied to an existing open space building and the performance is demonstrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of the U.S. Policies, Codes, and Standards of Zero-Carbon Buildings

The global issue of climate change has accelerated the international commitment to net-zero carbon emission development. Decarbonizing the building sector has been put on several governments’ sustainable development agendas. To provide a reference for decarbonizing the building sector, this paper summarizes the U.S. experience in zero-carbon buildings (ZCBs) from the aspects of policies, codes, and standards at the federal and local levels and those of professional societies. Based on the definition and boundaries of ZCBs, this paper introduces policies on building energy efficiency, electrification, on-site renewable energy deployment, and “buy clean”, illustrating highlights in building phases, energy systems, materials production, and fiscal incentives. The synergic efforts and coordination between federal and local levels and with professional societies are also introduced. Successful experiences in policy and standard implementation are summarized, including the systemic work of multilevel governance, clearly defined goals and stringent policies, constant upgrades of codes and standards, transparency in reporting and information sharing, and increased financial and investment opportunities. This paper provides concrete recommendations for developing zero-carbon building policies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗