Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “balance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Laboratory Kinetic Studies of OH and CO2 Relevant to Upper Atmospheric Radiation Balance

The purpose of this project was to quantify the rates of two processes which are crucial to our understanding of radiative energy balance in the upper atmosphere. The first process is radiative emission from vibrationally hot OH radicals following the H + O3 reaction in the upper mesosphere. The importance of this process depends strongly on the OH radiative emission coefficients. Our goal was to measure the OH permanent dipole moment in excited vibrational states and to use these measurements to construct an improved OH dipole moment function and improved radiative emission coefficients. Significant progress was made on these experiments including the construction of a supersonic jet source for vibrationally excited OH radicals. Unfortunately, our efforts to transport the OH radicals into a second lower pressure vacuum chamber were not successful, and we were unable to make improved dipole moment measurements for OH. The second key kinetic process which we attempted to quantify during this project is the rate of relaxation of bend-excited CO2 by oxygen atoms. Since excitation of the bending vibrational mode of CO2 is the major cooling mechanism in the upper mesosphere/lower thermosphere, the cooling rate of this region depends crucially on the rate of energy transfer out of this state. It is believed that the most efficient transfer mechanism is via atomic oxygen but the rate for this process has not been directly measured in the laboratory at appropriate temperatures and even the room temperature rate remains controversial. We attempted to directly measure the relaxation rate Of CO2 (010) by oxygen atoms using the discharge flow technique. This experiment was set up at Aerodyne Research. Again, significant progress was achieved in this experiment. A hot CO2 source was set up, bend excited CO2 was detected and the rate of relaxation of bend excited CO2 by He atoms was measured. Unfortunately, the project ran out of time before the oxygen atom kinetic studies could be implemented.

Nelson, David D.↗

PLUM: Parallel Load Balancing for Unstructured Adaptive Meshes

Dynamic mesh adaption on unstructured grids is a powerful tool for computing large-scale problems that require grid modifications to efficiently resolve solution features. By locally refining and coarsening the mesh to capture physical phenomena of interest, such procedures make standard computational methods more cost effective. Unfortunately, an efficient parallel implementation of these adaptive methods is rather difficult to achieve, primarily due to the load imbalance created by the dynamically-changing nonuniform grid. This requires significant communication at runtime, leading to idle processors and adversely affecting the total execution time. Nonetheless, it is generally thought that unstructured adaptive- grid techniques will constitute a significant fraction of future high-performance supercomputing. Various dynamic load balancing methods have been reported to date; however, most of them either lack a global view of loads across processors or do not apply their techniques to realistic large-scale applications.

Oliker, Leonid↗

Micromechanical Oscillating Mass Balance

A micromechanical oscillating mass balance and method adapted for measuring minute quantities of material deposited at a selected location, such as during a vapor deposition process. The invention comprises a vibratory composite beam which includes a dielectric layer sandwiched between two conductive layers. The beam is positioned in a magnetic field. An alternating current passes through one conductive layers, the beam oscillates, inducing an output current in the second conductive layer, which is analyzed to determine the resonant frequency of the beam. As material is deposited on the beam, the mass of the beam increases and the resonant frequency of the beam shifts, and the mass added is determined.

Altemir, David A.↗

Thermal and Hydrologic Signatures of Soil Controls on Evaporation: A Combined Energy and Water Balance Approach with Implications for Remote Sensing of Evaporation

The overall goal of this research is to examine the feasibility of applying a newly developed diagnostic model of soil water evaporation to large land areas using remotely sensed input parameters. The model estimates the rate of soil evaporation during periods when it is limited by the net transport resulting from competing effects of capillary rise and drainage. The critical soil hydraulic properties are implicitly estimated via the intensity and duration of the first stage (energy limited) evaporation, removing a major obstacle in the remote estimation of evaporation over large areas. This duration, or "time to drying" (t(sub d)), is revealed through three signatures detectable in time series of remote sensing variables. The first is a break in soil albedo that occurs as a small vapor transmission zone develops near the surface. The second is a break in either surface to air temperature differences or in the diurnal surface temperature range, both of which indicate increased sensible heat flux (and/or storage) required to balance the decrease in latent heat flux. The third is a break in the temporal pattern of near surface soil moisture. Soil moisture tends to decrease rapidly during stage 1 drying (as water is removed from storage), and then become more or less constant during soil limited, or "stage 2" drying (as water is merely transmitted from deeper soil storage). The research tasks address: (1) improvements in model structure, including extensions to transpiration and aggregation over spatially variable soil and topographic landscape attributes; and (2) applications of the model using remotely sensed input parameters.

Salvucci, Guido D.↗

Balanced Rotating Spray Tank and Pipe Cleaning and Cleanliness Verification System

A system for cleaning and verifying the cleanliness of the interior surfaces of hollow items, such as small bottles, tanks, pipes and tubes, employs a rotating spray head for supplying a gas-liquid cleaning mixture to the item's surface at a supersonic velocity. The spray head incorporates a plurality of nozzles having diverging cross sections so that the incoming gas-liquid mixture is first converged within the spray head and then diverged through the nozzles, thereby accelerating the mixture to a supersonic velocity. In the preferred embodiment, three nozzles are employed; one forwardly facing nozzle at the end of the spray head and two oppositely facing angled nozzles exiting on opposite sides of the spray head which balance each other, and therefore impart no net side load on the spray head. A drive mechanism is provided to rotate the spray head and at the same time move the head back and forth within the item to be cleaned. The drive mechanism acts on a long metal tube to which the spray head is fixed, and thus no moving parts are exposed to the interior surfaces of the items to be cleaned, thereby reducing the risk of contamination.

Caimi, Raoul E. B.↗

Performance Analysis and Portability of the PLUM Load Balancing System

The ability to dynamically adapt an unstructured mesh is a powerful tool for solving computational problems with evolving physical features; however, an efficient parallel implementation is rather difficult. To address this problem, we have developed PLUM, an automatic portable framework for performing adaptive numerical computations in a message-passing environment. PLUM requires that all data be globally redistributed after each mesh adaption to achieve load balance. We present an algorithm for minimizing this remapping overhead by guaranteeing an optimal processor reassignment. We also show that the data redistribution cost can be significantly reduced by applying our heuristic processor reassignment algorithm to the default mapping of the parallel partitioner. Portability is examined by comparing performance on a SP2, an Origin2000, and a T3E. Results show that PLUM can be successfully ported to different platforms without any code modifications.

Oliker, Leonid↗

Wind Tunnel Magnetic Suspension and Balance Systems With Transversely Magnetized Model Cores

This paper discusses the possibility of using vertically magnetized model cores for wind tunnel Magnetic Suspension and Balance Systems (MSBS) in an effort to resolve the traditional "roll control" problem. A theoretical framework is laid out, based on previous work related to generic technology development efforts at NASA Langley Research Center. The impact of the new roll control scheme on traditional wind tunnel MSBS configurations is addressed, and the possibility of demonstrating the new scheme with an existing electromagnet assembly is explored. The specific system considered is the ex- Massachusetts Institute of Technology (MIT), ex-NASA, 6-inch MSBS currently in the process of recommissioning at Old Dominion University. This system has a sufficiently versatile electromagnet configuration such that straightforward "conversion" to vertically magnetized cores appears possible.

Britcher, Colin P.↗

Application of Spaceborne Scatterometer to Study Typhoon, Tropical Hydrologic Balance and El Nino

The high spatial resolution and global coverage of a spaceborne microwave scatterometer make it a power instrument to study phenomena ranging from typhoon to El Nino Southern Oscillation which have regional and short term economic and ecological impacts as well as effects on long term and global climate changes. In this report, the application of scatterometer data, by itself, to study the intensity and the evolution of typhoon is demonstrated. The potential of combining wind vector and precipitable water derived from two spaceborne sensors to study the hydrologic balance in the tropics is discussed. The role of westerly wind bursts as a precursor of anomalous warming in the equatorial Pacific is investigated with coincident data from microwave scatterometer, altimeter and radiometer.

Liu, W. Timothy↗

Chromospheric and Coronal Structure of Polar Plumes: Magnetic Structure and Radiative Energy Balance - 1

The Multi-Spectral Solar Telescope Array (MSSTA), a rocket-borne solar observatory, was successfully launched from White Sands Missile Range, New Mexico, on May 13, 1991 at 19:05 UT. The telescope systems onboard the MSSTA obtained several full disk solar images in narrow bandpasses centered around strong soft X-ray, EUV, and FUV emission lines. Each telescope was designed to be sensitive to the coronal plasmas at a particular temperature, for seven temperatures ranging from 20,000 K to 4,000,000 K. We report here on the images obtained during the initial flight of the MSSTA, and on the chromospheric and coronal structure of polar plumes observed over both poles of the Sun. We have also co-aligned the MSSTA images with Kitt Peak magnetograms taken on the same day. We are able to positively identify the magnetic structures underlying the polar plumes we analyze as unipolar. We discuss the plume observations and present a radiative energy balance model derived from them.

Allen, Maxwell J.↗

Significance of Landsat-7 Spacecraft Level Thermal Balance and Thermal Test for ETM+Instrument

The thermal design and the instrument thermal vacuum (T/V) test of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) instrument were based on the Landsat-4, 5 and 6 heritage. The ETM+ scanner thermal model was also inherited from Landsat-4, 5 and 6. The temperature predictions of many scanner components in the original thermal model had poor agreement with the spacecraft and instrument integrated sun-pointing safehold (SPSH) thermal balance (T/B) test results. The spacecraft and instrument integrated T/B test led to a change of the Full Aperture Calibrator (FAC) motor stack "solar shield" coating from MIL-C-5541 to multi-layer insulation (MLI) thermal blanket. The temperature predictions of the Auxiliary Electronics Module (AEM) in the thermal model also had poor agreement with the T/B test results. Modifications to the scanner and AEM thermal models were performed to give good agreement between the temperature predictions and the test results. The correlated ETM+ thermal model was used to obtain flight temperature predictions. The flight temperature predictions in the nominal 15-orbit mission profile, plus margins, were used as the yellow limits for most of the ETM+ components. The spacecraft and instrument integrated T/B and TN test also revealed that the standby heater capacity on the Scan Mirror Assembly (SMA) was insufficient when the Earth Background Simulator (EBS) was 1 50C or colder, and the baffle heater possibly caused the coherent noise in the narrow band data when it was on. Also, the cooler cool-down was significantly faster than that in the instrument T/V test, and the coldest Cold Focal Plane Array (CFPA) temperature achieved was colder.

Choi, Michael K.↗

A Preliminary Model for Spacecraft Propulsion Performance Analysis Based on Nuclear Gain and Subsystem Mass-Power Balances

Rapid transportation of human crews to destinations throughout the solar system will require propulsion systems having not only very high exhaust velocities (i.e., I(sub sp) >= 10(exp 4) to 10(exp 5) sec) but also extremely low mass-power ratios (i.e., alpha <= 10(exp -2) kg/kW). These criteria are difficult to meet with electric propulsion and other power-limited systems, but may be achievable with propulsion concepts that use onboard power to produce a net gain in energy via fusion or some other nuclear process. This paper compares the fundamental performance of these gain-limited systems with that of power-limited systems, and determines from a generic power balance the gains required for ambitious planetary missions ranging up to 100 AU. Results show that energy gain reduces the required effective mass-power ratio of the system, thus enabling shorter trip times than those of power-limited concepts.

Chakrabarti, S.↗

Method of Manufacturing a Micromechanical Oscillating Mass Balance

A micromechanical oscillating mass balance and method adapted for measuring minute quantities of material deposited at a selected location, such as during a vapor deposition process. The invention comprises a vibratory composite beam which includes a dielectric layer sandwiched between two conductive layers.The beam is positioned in a magnetic field. An alternating current passes through one conductive layers, the beam oscillates, inducing an output current in the second conductive layer, which is analyzed to determine the resonant frequency of the beam. As material is deposited on the beam, the mass of the beam increases and the resonant frequency of the beam shifts, and the mass added is determined.

Altemir, David A.↗

The Effect of Age in the Alteration in Fluid Balance of Rats in Response to Centrifugation

With an increase in gravity load induced by centrifugation or upon return to Earth following spaceflight, there is a period of adjustment in fluid balance in rats. With centrifugation there is a reduced fluid intake with maintenance of the rate of urine excretion. Following spaceflight there is an increase in urine output and maintenance of fluid intake. The initial period of acclimation to hypergravity is associated with a net loss of fluids. In the present study in response to centrifugation at 2.0 G this period of acclimation is present in mature rats for a longer period of time, about 24 hours. Following this initial response a period of over compensation has previously been reported. In the present study this was not observed. The net effect of these alterations in water intake and output in response to centrifugation for 14 days was slight increase in the percent total body water, with effective compensation seen in both young and mature rats. Older rats have been shown to have a reduced relative thirst and compensatory renal function in response to hypohydration, hyperosmolality and pharmacological stimuli. Responsiveness to these stimuli are delayed and/or attenuated in older animals. Similar findings were noted in the present study in the initial response to centrifugation. The older animal had a delayed return of fluid intake to control levels. The delay of one day did not appear to effect long-term fluid homeostasis, as there was difference in the response of percent total body water at the end of 14 days of centrifugation with both age groups having a slight but significant increase. This increase has been attributed to the increase in lean body mass induced by centrifugation.

Fuller, Charles A.↗

System Risk Balancing Profiles: Software Component

The Software QA / V&V guide will be reviewed and updated based on feedback from NASA organizations and others with a vested interest in this area. Hardware, EEE Parts, Reliability, and Systems Safety are a sample of the future guides that will be developed. Cost Estimates, Lessons Learned, Probability of Failure and PACTS (Prevention, Avoidance, Control or Test) are needed to provide a more complete risk management strategy. This approach to risk management is designed to help balance the resources and program content for risk reduction for NASA's changing environment.

Kelly, John C.↗

Capillary Pressure Balance with Repeated Head-Up Tilt in Humans

We measured blood density (BD). plasma density (PD) and hematocrit (Ht) during repeated 70 deg head-up tilt (HUT) consisting of a pre-drink period with two supine (P and P3) and two HUT (P2 and P4) phases of 45 min each. At the end of P4 test subjects (N=8) drank 10 ml/kg body weight of isotonic (290 mOsm/kg) sodium chloride (ISO) or hypotonic (<10 mOsm/kg) unsweetened us (HYP), or nothing (control: CON). The following periods continued the supine (P5, P7) / upright (P6) sequence. Mass density of plasma and whole blood using a "mechanical oscillation" technique were measured from ear lobe blood. Tilting altered (p<0.001) BD, PD, and Ht in all consecutive Phases. BD and PD were different (p<0.05) between CON. HYP. and ISO Phases 6 and 7. The computed mass density of fluid (FD). which moved between intra. and extravascular compartments. averaged 1008 g/l and was the same in any conditions. In the non-drink treatment (P3, P5, P7), supine PV steadly decreased when compared to P1. Tilt-induced PV shifts ranged from 9.7 to 16.7% when compared to PV du. ring the respective previous Phases. After drinking, PV increased above CON values at the end of Phase 7 by 12.9% with ISO, and by 6.6% with HYP. Progressive hemoconcentration. occurred during non-drink supine; isotonic saline ingestion increased supine PV a control level but did not stop or reverse the decrease of upright hemoconcentration. Upright density values were not slowed with repeated upright tilting; decreased fluid loss occurred in consecutive upright periods. Upright capillary pressure balance was achieved with diminished plasma volume loss during repeated tilting.

Hinghofer-Szalkay, H. G.↗

Spatial Orientation and Balance Control Changes Induced by Altered Gravito-Inertial Force Vectors in Vestibular Deficient Patients

Eight chronic vestibular deficient (VD) patients (bilateral N = 4, unilateral N = 4, ages 18-67 were exposed to an interaural centripetal acceleration of 1 G (resultant 45 degree roll tilt of 1.4 G) on a 0.8 meter radius centrifuge for up to 90 minutes in the dark. The patients sat with head fixed upright, except every 4 of 10 minutes when instructed to point their nose and eyes towards a visual target (switched on every 3 to 5 seconds at random places within plus or minus 30 deg) in the Earth horizontal plane. Eye movements, including directed saccades for subjective Earth-and head-referenced planes, were recorded before, during, and after centrifugation using electro-oculography. Postural sway was measured before and within ten minutes after centrifugation using a sway-referenced or earth-fixed support surface, and with or without a head movement sequence. The protocol was selected for each patient based on the most challenging condition in which the patient was able to maintain balance with eyes closed.

Kaufman, Galen D.↗

Spatial Orientation and Balance Control Changes Induced by Altered Gravito-Inertial Force Vectors

Seventeen healthy and eight vestibular deficient subjects were exposed to an interaural centripetal acceleration of 1 G (resultant 45 deg roll tilt of 1.4 G) on a 0.8 meter radius centrifuge for a period of 90 minutes in the dark. The subjects sat with head fixed upright, except every 4 of 10 minutes when instructed to rotate their head so that their nose and eyes pointed towards a visual point switched on every 3 to 5 seconds at random places (within +/- 30 deg) in the Earth horizontal plane. Motion sickness caused some subjects to limit their head movements during significant portions of the 90 minute period, and led three normal subjects to stop the test earlier. Eye movements, including directed saccades for subjective Earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation using electro-oculography. Postural stability measurements were made before and within ten minutes after centrifugation. In normal subjects, postural sway and multisegment body kinematics were gathered during an eyes-closed head movement cadence (sway-referenced support platform), and in response to translational/rotational platform perturbations. A significant increase in postural sway, segmental motion amplitude and hip frequency was observed after centrifugation. This effect was short-lived, with a recovery time of several postural test trials. There were also asymmetries in the direction of post-centrifugation center of sway and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). To delineate the effect of the magnitude of the gravito-inertial vector versus its direction during the adaptive centrifugation period, we tilted eight normal subjects in the roll axis at a 45 deg angle in the dark for 90 minutes without rotational motion. Their postural responses did not change following the period of tilt. Based on verbal reports, normal subjects overestimated roll-tilt during 90 minutes of both tilt and centrifugation stimuli. Subjective estimates of head-horizontal, provided by directed saccades, revealed significant errors after approximately 30 minutes that tended to increase only in the group who underwent centrifugation. Immediately after centrifugation, subjects reported feeling tilted on average 10 degrees in the opposite direction, which was in agreement with the direction of their earth-directed saccades. In vestibular deficient (VD) subjects, postural sway was measured using a sway-referenced or earth-fixed support surface, and with or without a head movement sequence. 'Me protocol was selected for each patient during baseline testing, and corresponded to the most challenging condition in which the patient was able to maintain balance with eyes closed. Bilaterally VD subjects showed no postural decrement after centrifugation, while unilateral VD subjects had varying degrees of decrement. Unilateral VD subjects were tested twice; they underwent centrifugation both with right ear out and left ear out. Their post-centrifuation center of sway shifted at right angles depending on the centrifuge GIF orientation. Bilateral VD subjects bad shifts as well, but no consistent directional trend. VD subjects underestimated roll-tilt during centrifugation, These results suggest that orientation of the gravito-inertial vector and its magnitude arc both used by the central nervous system for calibration of multiple orientation systems. A change in the background gravito-inertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

Kaufman, Galen D.↗