Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Ultrasonic characterization of Ti-5Al-5Mo-5V-3Cr

Metastable β titanium alloys such as Ti-5Al-5Mo-5V-3Cr are of increasing interest due to their excellent corrosion resistance, high strength, and in particular, the ability to manipulate microstructure to a high degree to control the mechanical properties of the material. It is therefore important to consider how this manipulation of mechanical properties will affect the inspection of this material with ultrasonic testing both for the purposes of flaw detection and material characterization. The connection between material properties and ultrasonic characterization techniques will be discussed and then dissected in the context of Ti-5553. This metastable alloy was shown to exhibit remarkable variation in microstructure as well as ultrasonic velocity and attenuation demonstrating these techniques as potential candidates for characterizing Ti-5553 and Ti-5553 as a good candidate for aiding in future studies aimed at learning more about the role of secondary phases in ultrasonic wave propagation.

Sunderman, Ruth↗

Reconstruction of dynamic scenes based on differences between collected view and synthesized view

A system for generating a 4D representation of a scene in motion given a sinogram collected from the scene while in motion. The system generates, based on scene parameters, an initial 3D representation of the scene indicating linear attenuation coefficients (LACs) of voxels of the scene. The system generates, based on motion parameters, a 4D motion field indicating motion of the scene. The system generates, based on the initial 3D representation and the 4D motion field, a 4D representation of the scene that is a sequence of 3D representations having LACs. The system generates a synthesized sinogram of the scene from the generated 4D representation. The system adjusts the scene parameters and the motion parameters based on differences between the collected sinogram and the synthesized sinogram. The processing is repeated until the differences satisfy a termination criterion.

Kim, Hyojin↗

Source identification by non-negative matrix factorization combined with semi-supervised clustering

Machine-learning methods and apparatus are provided to solve blind source separation problems with an unknown number of sources and having a signal propagation model with features such as wave-like propagation, medium-dependent velocity, attenuation, diffusion, and/or advection, between sources and sensors. In exemplary embodiments, multiple trials of non-negative matrix factorization are performed for a fixed number of sources, with selection criteria applied to determine successful trials. A semi-supervised clustering procedure is applied to trial results, and the clustering results are evaluated for robustness using measures for reconstruction quality and cluster separation. The number of sources is determined by comparing these measures for different trial numbers of sources. Source locations and parameters of the signal propagation model can also be determined. Disclosed methods are applicable to a wide range of spatial problems including chemical dispersal, pressure transients, and electromagnetic signals, and also to non-spatial problems such as cancer mutation.

Alexandrov, Boian S.↗

Broadband differential absorption sensor for detecting gaseous species

A remote sensor system comprising a laser transmitter that emits a pulse of broadband laser illumination comprising a plurality of wavelengths and a receiver configured to detect laser illumination backscatter. The sensor system further includes a computing system configured to determine a plurality of species number densities along a travel path of the laser illumination. Determining the plurality of species number densities includes determining a first number density of a first species based on a first set of optical transmission values from the backscatter data for a first subset of wavelengths of the plurality of wavelengths and a first attenuation cross-section of the first species. Additional species are determined based on additional sets of optical transmission values from the backscatter data for additional subsets of wavelengths of the plurality of wavelengths and additional cross-sections of additional species.

Smith, Mark W.↗

Computed axial lithography optimization system

A system for determining a light intensity field for use in manufacturing a 3D object from a volume of material. The system receives a 3D specification of a 3D geometry for the 3D object that specifies voxels within the volume that contain material that is to be part of the 3D object. The system employs a cost function for effectiveness of a light intensity field in manufacturing the 3D object. The cost function may be an adjoint of an Attenuated Radon Transform that models an energy dose that each voxel would receive during manufacture of the 3D object using the light intensity field. The system applies an optimization technique that employs the cost function to generate a measure of the effectiveness of possible light intensity fields and outputs an indication of a light intensity field that will be effective in manufacturing the 3D object.

Shusteff, Maxim↗

Apparatus and methods of detecting transient discharge modes and/or closed loop control of pulsed systems and method employing same

A system and method for differentiating between different modes of pulsed electrical discharges via of an amplitude to time (ATC) conversion circuit is described. A bipolar ATC circuit is used to add together the positive and negative portions of an attenuated and filtered signal derived either from the voltage or current of a pulse. Alternatively, a unipolar ATC circuit may be employed. The resulting processed signal is compared against a reference voltage to generate an output signal that is active for the amount of time that the processed signal exceeds the reference voltage. Discharge mode is determined based on three factors: did a pulse occur, if a pulse occurred when did the pulse start relative to the original pulse event, and what is the duty cycle of the pulse. Subsequent pulse generated may be controlled accordingly.

Fitzpatrick, Joseph F.↗

Methods, systems, and computer-readable storage media for enhanced phase-contrast x-ray imaging

Systems and methods that directly image attenuation-based object grid, use a source grid to improve imaging of the object grid using a high-energy polychromatic source, and use a detector grid having gratings oriented substantially orthogonally to that of the object grid, can address artifacts and beam hardening effects that limit the quality and discriminatory power of high-energy x-ray imaging that includes phase contrast.

Miller, Erin A.↗

Pilot Test Remediation of a Fractured Bedrock Aquifer at the Maywood Superfund Site, Maywood, New Jersey - 20073

The U.S. Army Corps of Engineers (USACE) and Cabrera Services are conducting a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Pilot Test treatment of a fractured bedrock aquifer at the Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) located in Maywood, New Jersey (NJ), USA. The Maywood Chemical Company Superfund Site in Bergen County, NJ is listed on the United States Environmental Protection Agency (USEPA) Superfund National Priorities List (NPL). The National Superfund Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) identification number is NJD980529762. The Maywood Chemical Company Superfund Site (hereafter referred to as the FMSS) consists of 92 designated properties in the communities of Maywood, Lodi and Rochelle Park, NJ. These are collectively known as FMSS 'Vicinity Properties' and include property owned by the federal government (the Maywood Interim Storage Site, or MISS); the Stepan Company (former location of the Maywood Chemical Works, or MCW); 62 residential properties; three properties owned by the state or federal government; four municipal properties; and 21 commercial properties. The Stepan Company property includes contaminated buildings and three remediated U.S. Nuclear Regulatory Commission (NRC) licensed burial pits; the MISS also includes a contaminated building. Contamination on the FMSS is being addressed under three separate actions coordinated by the lead regulator USEPA Region 2. The USACE is addressing thorium (Th) and other wastes at the site defined as 'FUSRAP waste' in the Soils and Buildings and Groundwater Records of Decision (ROD) for the FMSS. Stepan Company is addressing other chemical wastes (non-FUSRAP waste) at the FMSS. The Groundwater ROD [1] was signed into agreement by USACE Division Commander in June 2012 and USEPA Region 2 Administrator in July 2012 and presents the selected remedial actions for Operable Unit (OU) 2 groundwater at the MISS and adjacent properties. The selected remedial action is removal of non-radiologically contaminated soils on the MISS containing arsenic, lithium, and benzene with concentrations above cleanup levels, and monitored natural attenuation (MNA) of arsenic, lithium, and benzene in groundwater. In situ treatment of arsenic in the overburden aquifer using oxidation reduction (redox) alteration will also be performed if needed to meet the groundwater cleanup levels after the source soil is removed. The need for in situ treatment will be determined during the Groundwater ROD review at least three to four years after the contaminated source soil removal is completed. The third action addressing non-FUSRAP chemical wastes will be the responsibility of the Stepan Company as a primary responsible party in this action. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a Convolutional Neural Network Classifier for Data Starved Spectra - 20199

The Institute for Clean Energy Technology (ICET) at Mississippi State University is exploring the utility of machine learning in augmenting its mobile radiation surveying platforms, which are currently being developed as means to survey depleted uranium contaminated areas in support of remediation and decommissioning efforts. Mobile survey platforms provide a means to efficiently scan large areas of interest while reducing human exposure to radiation and other hazards. The survey platforms can also be used for scanning for any gamma emitting isotope in addition to depleted uranium. The spectral data that the platforms collect may be data starved with relatively low counts and poorly defined spectral features depending on the speed of the platforms and scintillation detector selection. Such data-starved spectra are difficult to use for isotope identification, requiring advanced knowledge of the possible radionuclides that could be present and environmental factors that could attenuate signals or introduce background noise. These factors in combination with the volume of survey data increases the time it takes to perform analysis of survey data when the source type is unknown. There are a number of algorithms in the field of machine learning that can be used to classify data that would be challenging and time-consuming for a human to identify. Supervised machine learning algorithms train models based on extensive amounts of human-labeled training data. Once sufficiently trained, these models can be used to quickly make high-fidelity predictions on new data. Convolutional neural networks are machine learning algorithms that excel in learning representations of 'shapes'. They do this by taking numerical input data and convolving them with spatial feature detectors referred to as filters. These filters are incrementally adjusted to reduce the prediction error on the data during the backpropagation step of training. Discussed in this paper is the development of a convolutional neural network classifier (CNNC) that can utilize spectral survey data for source discrimination and isotope identification. Bench-top laboratory experiments data using LaBr{sub 3}(Ce) scintillation detectors were used to train and evaluate the performance of the developed CNNC. The CNNC is capable of discriminating a variety of gamma emitting source types, differentiating different forms of uranium (depleted vs. natural), and estimating the amount of uranium for a known geometry. The discussed CNNC may be useful in scenarios where survey systems are deployed in situations where hazardous radioactive material maybe present, but the type is unknown. When used in remediation applications the CNNC can be used to screen-out false positives, helping reduce remediation costs. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Multivariate Linear Models for In Situ Monitoring of Low-Activity Nuclear Waste Using Infrared and Raman Spectroscopy - 20218

This paper presents the use of in situ monitoring tools for molecular analysis of non-radioactive species found in the supernatant liquid and dissolvable salt cake of nuclear waste at Hanford. We have selected two in situ spectroscopic techniques that do not require any sample preparation or consumables: infrared (in the form of attenuated total reflectance Fourier transform infrared or ATR-FTIR) and Raman spectroscopy. This work aims to evaluate their performance for liquid waste simulants representative of the Hanford DFLAW (Direct Feed Low-Activity Waste) feed. In addition, we have evaluated the performance of four multivariate linear models that extract concentrations from spectral measurements for a data set that was designed to include key molecular species found in liquid low-activity waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Challenge of Achieving Site Closure of a Complex Groundwater Plume - 20531

Over the last three decades, DOE has made substantial progress in nearly every area of nuclear waste cleanup and has closed and transitioned 91 of the 107 sites in the EM complex. Several of the remaining groundwater plumes at Hanford, Los Alamos, Paducah, Oak Ridge, and Savannah River are complex and tend to have unique site or contaminant characteristics which provide an almost impossible challenge to remediate to regulatory levels. As a result, these complex sites will require a large investment to remediate. In order for DOE to achieve regulatory closure, a technically sound case must be developed and presented to regulators and stakeholders that clearly demonstrates that remedial goals have been or will be irreversibly achieved or that there is an alternate acceptable end-state. Five lines of evidence are required: - A conceptual site model that is as complete as possible, with the knowledge that it may continue to evolve with time; - Demonstration that trends in contaminant concentrations, or flux, versus time indicate that remedial goals will be achieved on schedule or within a reasonable time thereafter and that trends that deviate from this path are explainable by the conceptual model; - Demonstration that remobilization of attenuated contaminants is unlikely to occur in the future; - Explicit consideration of remedial contingencies, should deviations in the path toward remedial goals occur; - Development of an effective long-term monitoring plan to detect any conditions that might alter the path toward remedial goals. SRS has made significant progress in the remediation of contamination associated with the F-area and H-Area Seepage Basins, and it is currently developing a strategic closure path that addresses each of these lines of evidence and identifies both basic and applied scientific issues that will need to be addressed in order to obtain regulatory closure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultra-Long Distance BOTDA Sensor System Employing Hybrid Amplification and Advanced Noise Reduction Techniques

Brillouin Optical Time Domain Analysis (BOTDA) sensor systems play a pivotal role in distributed sensing, which enables precise measurements of strain and temperature across extensive fiber lengths. This research offers a comprehensive strategy to extend the sensing range of BOTDA systems beyond tens of kilometers while maintaining high spatial resolutions. Such enhanced sensing is realized through the integration of distributed Raman amplification, inline amplification using erbium-doped fiber amplifiers (EDFA), and advanced noise reduction techniques. Optimizing Raman pump and probe wave profiles ensures the robustness of Brillouin scattering signals, effectively countering attenuation-induced losses. Additionally, enhancing weak Brillouin signals by strategically placing EDFAs at optimal fiber locations keeps sensor sensitivity high. Leveraging inherent redundancy in measured data as a function of frequency and fiber distance, the non-local means (NLM) filter removes noise while preserving essential physical information. In summary, this research has shown a holistic exploration of extending BOTDA’s distance sensing capabilities up to 150 km with spatial resolutions of 8 meters.

Bhatta, Hari↗

Realization of a high luminosity muon beam at the Jefferson Lab

The proton is the major component of the visible matter of our universe, so being able to determine its fundamental properties, such as its charge radius, is of vital importance. In recent years, several experiments have been performed for the accurate measurement of the proton radius with different experimental techniques. The main and most common are based on two different techniques: ep scattering and Lamb shift spectroscopy of regular hydrogen atoms. The latter can also be performed on muonic hydrogen atoms with a significant improvement in accuracy. Recent measurements that use this method have highlighted a discrepancy between the results obtained with the diffusion of electrons and those obtained with the spectroscopic technique leading to the so-called ?proton radius puzzle?. The explanation of why this difference between the measured values exists is still a matter of discussion. The last attempt to address the puzzle was the PRad Experiment. It was performed with a unique experimental setup that gave the scientists an excellent control on the systematic errors that are usually present in electron-proton scattering experiments. This has significantly increased the precision of the measurement, bringing it in the same area as the spectroscopic ones done on muonic hydrogen atoms, which are considered the most precise. However, to solve the puzzle once and for all, even more precise electron scattering measurements are needed. Alternatively, new methods can be used, such as eg. muon-proton scattering at low transferred momenta in order to lower the systematic errors that comes with the measurement. This thesis tries to address this problem by studying the set up of an intense muon beam at the Jefferson Laboratory (JLab) that can be used to carry out a high-precision m ? p scattering experiment. Using Montecarlo simulations I studied the muon production resulting from the interaction of the primary electron beam with the beam-dump at JLab Hall-A. The simulations were performed using the FLUKA package via the FLAIR graphical interface. In this study, I modified an existing geometry (built for the ?Beam Dump eXperiment?) and performed several studies in order to optimize the muon beam parameters. In order to estimate the beam intensity, I studied the muon generation and transportation through the concrete bunker surrounding the Hall-A beam-dump. Detailed studies on muon attenuation and dispersion at different depth allowed me to track the beam profile in space and momentum as a function of the distance from the beam-dump. Last, but not least, I studied a possible tagging system for the muon beam. The tagging system will allow us to know with good precision (O(1=1000)) the energy of each muon of the beam. Based on the results obtained, I created an event generator that incorporates the detailed description of the muon beam (energy, position, emittance) useful to define and optimize the experimental setup for a future measurement of the proton radius at the JLab.

Fulci, Antonino↗

Elimination LArTPC Simulation Uncertainty

Liquid Argon Time Projection Chambers (LArTPC) are crucial for measuring muons and neutrinos by capturing the paths of fast-moving particles through argon gas. However, these detectors face challenges such as electron-ion recombination, diffusion, and attenuation, which introduce uncertainties in simulation models. This study, conducted by Ka ren Mkrtchyan at FERMILAB, aims to reduce these uncertainties by adjusting the amplitude and width of signals detected by the TPC wires. Initial findings indicate that the current modification algorithm requires further refinement to better align simulations with observed data. Ongoing work focuses on correcting computational bugs and enhancing the simulation model for improved accuracy and statistical confidence.

Mkrtchyan, Ka'ren↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Passive continuous variable quantum key distribution scheme using a thermal source

A passive continuous variable quantum key distribution scheme, where Alice splits the output of a thermal source into two beams, measures one locally and transmits the other mode to Bob after applying attenuation. A secure key can be established based on measurements of the two beams without the use of a random number generator or an optical modulator.

Qi, Bing↗

Modeling and analyzing parasitic parameters in high frequency converters

This research focuses on electromagnetic interference (EMI) / electromagnetic compatibility (EMC) design and analysis in power electronics systems. To limit the EMI under the standards, different methods and strategies are investigated. Parasitic parameters of high frequency (HF) transformer are analyzed using a novel analytical method, finite element method (FEM), and experimental measurements for different structures and windings arrangements. Also, the magnetic field, electric field, electric displacement, and electric potential distribution are simulated and analyzed. Moreover, a high voltage system is considered and analyzed to improve the EMC. The EMI propagation paths are analyzed. The EMI noise level of the system is obtained and compared to the IEC61800-3 standard. To improve the EMC, the parasitic parameters of the transformer, as the main path of EMI circulation, are analyzed and optimized to block the propagation. Furthermore, the geometry structure of the HF transformer is optimized to lower the parasitics in the system. Three pareto-optimal techniques are investigated for the optimization. The models and results are verified by 3D-FEM and experimental results for several given scenarios. Furthermore, the EMC modeling and conducted EMI analysis are developed for a system including an AC-DC-DC power supply (rectifier and dual active bridge (DAB) converter). Moreover, the common mode (CM) EMI noise propagation through the system is discussed and the noise sources and effect of components on the noise are analyzed. Additionally, the CM impedance of different parts of the system and the noise levels are discussed. Finally, EMI attenuation techniques were applied to the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Non-destructive Post-Transient Examination Results of the MOXTOP-1 Experiment

The MOXTOP-1 experiment has been assembled and irradiated in INL’s HFEF and TREAT facilities followed by disassembly of the experiment to enable initial post-transient examination. Results of neutron radiography of the fuel pin still in the THOR capsule were somewhat inconclusive due to the additional scatter and attenuation from the iron heat sink included in the design. Nonetheless, no obvious failure or fuel relocation could be identified in the radiography. Following disassembly of the fuel pin from the capsule, initial visual inspections were performed, and documented via images obtained through the hot cell window. No obvious signs of fuel failure were identified, indicating that the fuel pin remained intact during the transient. Some discoloration was observed near the middle of the fuel pin, likely corresponding to the fueled zone indicating that that region may have reached a relatively high temperature. Pre-transient, and post-transient profilometry of the fuel pin were performed and compared. Some additional strain displacement in the bottom portion of the fuel zone is identified, but remains well below 1%.

Mixed Oxide↗