Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “YIn”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Frequency Injection Based HVDC Attack-Defense Control Via Squeeze-Excitation Double CNN

Due to the independent controllability and fast power regulation capability, the High Voltage Direct Current (HVDC) system could be a prospective technology to provide multiple ancillary services to the system besides conventional bulk power transmission. However, with the increase of False Data Injection Attacks (FDIAs) on PMU data, the HVDC system could have the wrong response once the collected data that the HVDC system relied on is attacked, thus threatening the system operating security. How to ensure the security of the PMU-based HVDC ancillary service control become an urgent issue. To mitigate the risk, this paper proposed an HVDC attack-defense control based on the FDIAs detection method. Firstly, the Squeeze-Excitation based Double Convolutional Neural Networks (SE-DCNN) is proposed to realize fast identification of the attacking frequency type based on the time and frequency domain signals. Furthermore, the duration time of FDIAs is detected by the local outlier factor. Then, utilizing the results from SE-DCNN, HVDC ancillary service control framework is reorganized and an HVDC attack defense control is proposed for suppressing the potential influence of various types of FDIAs on the HVDC system ancillary service. Different experiments results demonstrate that the proposed method has the ability to significantly mitigate the frequency deviation and oscillation under the FDIA.

42 ENGINEERING↗

Physics-Informed Evolutionary Strategy Based Control for Mitigating Delayed Voltage Recovery

Here, in this work we propose a novel data-driven, real-time power system voltage stability control method based on the physics-informed guided meta evolutionary strategy (ES). The main objective is to quickly provide an adaptive control strategy to secure system voltage stability. The problem is challenging due to the high-dimensional feature of the power system model and the fast-changing and uncertain nature of power system operation scenarios. To this end, a model-free and derivative-free guided ES method is applied. The method is further combined with a meta-learning strategy to make the learnt control policy automatically adapted to unseen operation conditions and fault scenarios, which is highly desired for real-time emergency control. Last but not least, physical knowledge is embedded in the above method through a trainable action mask technique to rule out unnecessary load shedding actions for better learning and control performance. Case studies on the IEEE 300-bus system and comparisons with other state-of-the-art benchmark methods verify the superiority of the proposed physics-informed guided meta ES method in realizing fast and adaptive power system voltage stability control.

42 ENGINEERING↗

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. Here, in this paper, we mitigate these limitations by developing a novel deep meta-reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method, which achieves superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods for Analysis and Quantification of Power System Resilience

This paper summarizes the report prepared by an IEEE PES Task Force. Resilience is a fairly new technical concept for power systems, and it is important to precisely delineate this concept for actual applications. As a critical infrastructure, power systems have to be prepared to survive rare but extreme incidents (natural catastrophes, extreme weather events, physical/cyber-attacks, equipment failure cascades, etc.) to guarantee power supply to the electricity-dependent economy and society. Thus, resilience needs to be integrated into planning and operational assessment to design and operate adequately resilient power systems. Quantification of resilience as a key performance indicator is important, together with costs and reliability. Quantification can analyze existing power systems and identify resilience improvements in future power systems. Given that a 100% resilient system is not economic (or even technically achievable), the degree of resilience should be transparent and comprehensible. Several gaps are identified to indicate further needs for research and development.

42 ENGINEERING↗

Real-Time Detection and Localization of Line Trip Event Via Relative Phase Angles

Line trip events widely exist in power systems. They can result in power outages and a huge economic loss if not promptly detected and localized. To provide a fast and precise solution, this paper presents a Complete Coverage of Voltage Measurement (CCVM)-based line trip event detection algorithm and a Relative Phase Angle (RPA)-based line trip event localization algorithm. First, frequency and relative phase angle features during a line trip event are calculated. Then, the CCVM-based algorithm is proposed from both frequency and rate of change of frequency estimation algorithm aspects. Additionally, the RPA-based algorithm is presented, and two cases are studied to demonstrate the uniqueness of the proposed algorithm. Various experiments are conducted, where the simulation results demonstrate that the proposed CCVM-based algorithm can detect a line trip event as short as 2.07 ms. In addition, the RPA-based algorithm has 1.26 times higher localization accuracy compared with the frequency magnitude-based and phase angle-based algorithms. In conclusion, the experiment results on the examples from two interconnected power systems in the U.S. verified the performance of the proposed algorithms in wide-area power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Disturbance Event Detection Based on Synchrophasors and Deep Learning

Power system frequency disturbances are caused by various generation and transmission events including generator trips, load disconnections, line trips, etc. Accurate detections of the events are crucial to bulk power system situation awareness and event investigation. This paper utilizes the recent advances of deep learning to build a convolutional neural network model to detect events in an accurate yet straightforward manner. Herein, the rate of change of frequency and the relative angle shift are converted to images as the inputs of the proposed model. Finally, this paper uses two convolutional neural networks and classifier fusion to achieve the detection result. Compared with the conventional event detection algorithm and the frequency only deep learning model, the proposed model improves the detection accuracy by over 48%. As a promising tool for bulk power system situation awareness, the proposed model requires a short decision time, which is suitable for practical scenarios.

42 ENGINEERING↗

Model-Free Data Authentication for Cyber Security in Power Systems

With the development and wide deployment of measurement equipment, data can be automatically measured and visualized for situation awareness in power systems. However, the cyber security of power systems is also threated by data spoofing attacks. This letter proposed a measurement data source authentication (MDSA) algorithm based on feature extraction techniques including ensemble empirical mode decomposition (EEMD) and fast Fourier transform (FFT), and machine learning for real-time measurement data classification. Compared with previous work, the proposed algorithm can achieve higher accuracy of MDSA using a shorter window of data from closely located synchrophasor measurement sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience-Motivated Distribution System Restoration Considering Electricity-Water-Gas Interdependency

A major outage in the electricity distribution system may affect the operation of water and natural gas supply systems, leading to an interruption of multiple services to critical customers. Therefore, enhancing resilience of critical infrastructures requires joint efforts of multiple sectors. In this paper, a distribution system service restoration method considering the electricity-water-gas interdependency is proposed. The objective is maximizing the supply of electricity, water, and gas to critical customers after an extreme event. The operational constraints of electricity, water, and natural gas networks are considered. Additionally, the characteristics of electricity-driven coupling components, including water pumps and gas compressors, are also modeled. Relaxation techniques are applied to non convex constraints posed by physical laws of those networks. Consequently, the restoration problem is formulated as a mixed-integer second-order cone program, which can readily be solved by the off-the-shelf solvers. The proposed method is validated by numerical simulations on an electricity-water-gas integrated system, developed based on benchmark models of the subsystems. The results indicate that considering the interdependency refines the allocation of limited generation resources and demonstrate the exactness of the proposed convex relaxation

24 POWER TRANSMISSION AND DISTRIBUTION↗

Restoration Strategy for Active Distribution Systems Considering Endogenous Uncertainty in Cold Load Pickup

Cold load pickup (CLPU) phenomenon is identified as the persistent power inrush upon a sudden load pickup after an outage. Under the active distribution system (ADS) paradigm, where distributed energy resources (DERs) are extensively installed, the decreased outage duration can induce a strong interdependence between CLPU pattern and load pickup decisions. In this paper, we propose a novel modelling technique to tractably capture the decision-dependent uncertainty (DDU) inherent in the CLPU process. Subsequently, a two-stage stochastic decision-dependent service restoration (SDDSR) model is constructed, where first stage searches for the optimal switching sequences to decide step-wise network topology, and the second stage optimizes the detailed generation schedule of DERs as well as the energization of switchable loads. Further, to tackle the computational burdens introduced by mixed-integer recourse, the progressive hedging algorithm (PHA) is utilized to decompose the original model into scenario-wise subproblems that can be solved in parallel. The numerical test on modified IEEE 123-node test feeders has verified the efficiency of our proposed SDDSR model and provided fresh insights into the monetary and secure values of DDU quantification.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

Multifractal Characterization of Distribution Synchrophasors for Cybersecurity Defense of Smart Grids

“Source ID Mix” spoofing emerged as a new type of cyber-attack on Distribution Synchrophasors (DS) where adversaries have the capability to swap the source information of DS without changing the measurement values. Accurate detection of such a highly-deceptive attack is a challenging task especially when the spoofing attack happens on short fragments of DS recorded within a relatively small geographical scale. Herein this letter proposes an effective approach to detect this cyber-attack by realizing the multifractal characteristics of DS measurements. First, the multifractal cross-correlation of DS measured at multiple intra-state locations is revealed. Then the derived correlation is integrated with weighted two-dimensional multifractal surface interpolation to reconstruct quasi high-resolution signals. Finally, informative location-specific signatures are extracted from the high-resolution DS and they are integrated with advanced machine learning techniques for source authentication. Experiments using the real-life DS are performed to verify the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Enhancement for Multi-Infeed High-Voltage DC Systems

Composed of multiple two-terminal high-voltage DC (HVDC) transmission systems, a multi-infeed HVDC (MIDC) system exchanges massive power among multiple asynchronous AC systems. However, as an intrinsically cyber-physical system, an MIDC system could suffer from cyber-attacks, leading to massive power mismatches in multiple AC systems, and resulting in catastrophic consequences. Since the sequential responses of an MIDC system and interconnected AC systems are in different timescales, this paper first establishes a two-timescale model to evaluate the sequential impacts caused by cyber-attacks. Then, an event-triggered cyber-defense strategy is proposed to enhance the cybersecurity of an MIDC system by mitigating multiple non-simultaneous cyber-attacks. Whenever new cyber-attack events occur, the proposed cyber-defense strategy, which is mathematically modeled as a mixed-integer quadratic programming problem, is executed on-line and updated in an event-triggered manner. Here, simulation results on an MIDC system demonstrate that the low-cost and almost blind cyber-attacks can cause severe frequency deviations, and the proposed strategy can mitigate multi-cyber-attacks effectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilient Control of Networked Microgrids Using Vertical Federated Reinforcement Learning: Designs and Real-Time Test-Bed Validations

Improving system-level resiliency of networked microgrids against adversarial cyber-attacks is an important aspect in the current regime of increased inverter-based resources (IBRs). To achieve that, this paper contributes in designing a hierarchical control layer, in conjunction with the existing control layers, resilient to adversarial attack signals. Considering model complexities, unknown dynamical behaviors of IBRs, and privacy issues regarding data sharing in multi-party-owned microgrids, designing such a control layer is non-trivial. Here, to tackle these issues, a novel federated reinforcement learning (Fed-RL) method is proposed. To grasp the interconnected dynamics of networked microgrids, the paper develops Federated Soft Actor-Critic (FedSAC) algorithm following the vertical structure of implementing Fed-RL. Next, utilizing the OpenAI Gym interface, we built a custom set-up in GridLAB-D/HELICS co-simulation platform, named Resilient RL Co-simulation (ResRLCoSIM), to train the RL agents with IEEE 123-bus benchmark comprising 3 interconnected microgrids. Finally, the learned policies in the simulation are transferred to the real-time hardware-in-the-loop (HIL) test-bed developed using the high-fidelity Hypersim platform. Finally, experiments show that the simulator-trained RL controllers achieve desirable performance with the test-bed platform, validating the minimization of the sim-to-real gap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchro-Waveform-Based Event Identification Using Multi-Task Time-Frequency Transform Networks

Influenced by the transient dynamics and reduced inertia characteristics of high-penetration renewable energy systems, power system events frequently exhibit distinct characteristics such as high-frequency components including wide-band oscillations and hyper-harmonics. This makes standard systems face challenges including significant latency and reduced accuracy due to limited data resolution. However, current methods face significant limitations, including insufficient pattern capture ability, low noise immunity, limited feature learning, and restricted localization capabilities, thereby hindering real-time performance. To tackle this issue, this paper proposed a novel synchro-waveform-based event identification approach via a Multi-task Time-frequency Transform Network (MTTNet). Initially, a Time-frequency Transform Block (TTB) is developed to extract both local and global information. The TTB leverages both Fourier and S-transforms to derive comprehensive time-frequency information from synchro-waveforms. Subsequently, a multi-task learning strategy is employed to identify the type and distinguish localization of events. Integrating the TTB and multi-task learning, the MTTNet is designed for synchro-waveform-based event identification, incorporating an adaptive weighting strategy and simplified computation for the S-transform. Two different datasets, comprising simulated and actual synchro-waveforms, are collected from the IEEE 123 bus system and a real-world high-penetration renewable energy system using a universal grid analyzer. Extensive experiments on various conditions are carried out. In conclusion, results demonstrated that the MTTNet consistently surpasses both basic and advanced baselines, with maximum improvements of 13.24% and 9.86%, respectively, while reducing the calculation burden by 15-19 times to achieve real-time event identification.

Event identification↗

Neural Networks-Based Inverter Control: Modeling and Adaptive Optimization for Smart Distribution Networks

The optimal voltage control of inverter-based resources, especially under the high penetration of solar photovoltaics, is critical to the stability of the distribution power system. However, the computational complexity as well as the coordinated operation performance of the voltage control optimization in the distribution power system limits the real-time applications. To mitigate this issue, a model-free based adaptive optimal control scheme for the smart inverter is proposed to maximize the active power generation, minimize the power loss, and maintain the bus voltages in smart distribution networks. An inverter-based optimization model for coordinated operation is first established, considering the uncertainties of renewable power generation. Subsequently, by collecting the data and control strategies, the neural networks (NNs) based algorithm is proposed to efficiently predict the best possible control strategy. The main objective of this scheme is to accurately predict candidate optimal solutions with near-negligible feasibility and optimization gaps, with the advantage of avoiding complicated iteration-based numerical algorithms. Thereafter, the co-simulation among OpenDSS, MATLAB, and Python is set up to fully take advantage of the three individual software. Experiments are conducted based on different control parameter characteristics and structures of NNs. Finally, the results reveal that an average mean squared error of 0.013 and 1 ms response time are achieved, which is lower than some state-of-the-art methods.

42 ENGINEERING↗

Distributionally Robust Bilevel Optimization Model for Distribution Network With Demand Response Under Uncertain Renewables Using Wasserstein Metrics

Here, we consider a distribution network integrating demand response (DR) participants in the presence of uncertain renewable suppliers and outdoor temperatures. A bilevel optimization model is proposed to capture the intricate dynamics between price-incentivized DR participants and distribution system operations, including energy procurement and active/reactive power flows. The model is formulated as a distributional robust bilevel optimization using Wasserstein metrics. We show favorable data-driven properties including out-of-sample guarantee and asymptotic consistency. Furthermore, we present a tractable mixed-integer linear programming reformulation and characterize the worst-case distribution. Computational experiments are conducted on a modified 33-bus system. Our findings underscore the efficacy of the pricing strategies derived from the proposed bilevel optimization model. These strategies not only effectively manage DR participants' behavior but also bring equity considerations among households with various characteristics to light. The results contribute to a deeper understanding of the interplay between distribution system operators and DR participants.

24 POWER TRANSMISSION AND DISTRIBUTION↗