Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VALVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Atrial Septal Aneurysm and Patent Foramen Ovale as Risk Factors for Cryptogenic Stroke in Patients Less Than 55 Years of Age: A Study using Transesophageal Echocardiography

Background and Purpose: An association between atrial septal aneurysm and embolic events has been suggested. Atrial septal aneurysm has been shown to be associated with patent foramen ovale and,.in some reports, with mitral valve prolapse. These two latter cardiac disorder; have been identified as potential risk factors for ischemic stroke. The aim of this prospective study was to assess the role of atrial septal aneurysm as an independent risk factor for stroke, especially for cryptogenic stroke. Methods: We studied the prevalence of atrial septal aneurysm, patent foramen ovale, and mitral valve prolapse in 100 consecutive patients <55 years of age with ischemic stroke who underwent extensive etiological investigations. We compared these results with those in a control group of 50 consecutive patients. The diagnosis of atrial septal aneurysm and patent foramen ovale relied on transesophageal echocardiography with a contrast study and that of mitral valve prolapse, on two-dimensional transthoracic echocardiography. Results: Stepwise logistic regression analysis showed that atrial septal aneurysm (odds ratio, 4.3; 95% confidence interval, 1.3 to 14.6; P=.01) and patent foramen ovale (odds ratio, 3.9; 95% confidence interval, 1.5 to 10; P=.003) but not mitral valve prolapse were significantly associated with the diagnosis of cryptogenic stroke. The stroke odds of a patient with both atrial septal aneurysm and patent foramen ovale were 33.3 times (95% confidence interval, 4.1 to 270) the stroke odds of a patient with neither of these cardiac disorders. For a patient with atrial septal aneurysm of >lo-mm excursion, the stroke odds were approximately 8 times the stroke odds of a patient with atrial septal aneurysm of <10 mm. Conclusions: This study shows that atrial septal aneurysm and patent foramen ovale are both significantly associated with cryptogenic stroke and that their association has a marked synergistic effect. Atrial septal aneurysms of >lo-mm excursion are associated with a higher risk of stroke. (Stroke. 1993;24:1865-1873.) KEY WORDS aneurysm echocardiography foramen ovale, patent mitral valve prolapse o young adults

Cabanes, L.↗

GUI for Computational Simulation of a Propellant Mixer

Control Panel is a computer program that generates a graphical user interface (GUI) for computational simulation of a rocket-test-stand propellant mixer in which gaseous hydrogen (GH2) is injected into flowing liquid hydrogen (LH2) to obtain a combined flow having desired thermodynamic properties. The GUI is used in conjunction with software that models the mixer as a system having three inputs (the positions of the GH2 and LH2 inlet valves and an outlet valve) and three outputs (the pressure inside the mixer and the outlet flow temperature and flow rate). The user can specify valve characteristics and thermodynamic properties of the input fluids via userfriendly dialog boxes. The user can enter temporally varying input values or temporally varying desired output values. The GUI provides (1) a set-point calculator function for determining fixed valve positions that yield desired output values and (2) simulation functions that predict the response of the mixer to variations in the properties of the LH2 and GH2 and manual- or feedback-control variations in valve positions. The GUI enables scheduling of a sequence of operations that includes switching from manual to feedback control when a certain event occurs.

Figueroa, Fernando↗

Improved Electrohydraulic Linear Actuators

A product line of improved electrohydraulic linear actuators has been developed. These actuators are designed especially for use in actuating valves in rocket-engine test facilities. They are also adaptable to many industrial uses, such as steam turbines, process control valves, dampers, motion control, etc. The advantageous features of the improved electrohydraulic linear actuators are best described with respect to shortcomings of prior electrohydraulic linear actuators that the improved ones are intended to supplant. The flow of hydraulic fluid to the two ports of the actuator cylinder is controlled by a servo valve that is controlled by a signal from a servo amplifier that, in turn, receives an analog position-command signal (a current having a value between 4 and 20 mA) from a supervisory control system of the facility. As the position command changes, the servo valve shifts, causing a greater flow of hydraulic fluid to one side of the cylinder and thereby causing the actuator piston to move to extend or retract a piston rod from the actuator body. A linear variable differential transformer (LVDT) directly linked to the piston provides a position-feedback signal, which is compared with the position-command signal in the servo amplifier. When the position-feedback and position-command signals match, the servo valve moves to its null position, in which it holds the actuator piston at a steady position.

Hamtil, James↗

Compact Instruments Measure Helium-Leak Rates

Compact, lightweight instruments have been developed for measuring small flows of helium and/or detecting helium leaks in solenoid valves when the valves are nominally closed. These instruments do not impede the flows when the valves are nominally open. They can be integrated into newly fabricated valves or retrofitted to previously fabricated valves. Each instrument includes an upstream and a downstream thermistor separated by a heater, plus associated analog and digital heater-control, signal- conditioning, and data-processing circuits. The thermistors and heater are off-the-shelf surface mount components mounted on a circuit board in the flow path. The operation of the instrument is based on a well-established thermal mass-flow-measurement technique: Convection by the flow that one seeks to measure gives rise to transfer of heat from the heater to the downstream thermistor. The temperature difference measured by the thermistors is directly related to the rate of flow. The calibration curve from temperature gradient to helium flow is closely approximated via fifth-order polynomial. A microprocessor that is part of the electronic circuitry implements the calibration curve to compute the flow rate from the thermistor readings.

Stout, Stephen↗

Larger-Stroke Piezoelectrically Actuated Microvalve

A proposed normally-closed microvalve would contain a piezoelectric bending actuator instead of a piezoelectric linear actuator like that of the microvalve described in the preceding article. Whereas the stroke of the linear actuator of the preceding article would be limited to approximately equal to 6 micrometers, the stroke of the proposed bending actuator would lie in the approximate range of 10 to 15 micrometers-large enough to enable the microvalve to handle a variety of liquids containing suspended particles having sizes up to 10 m. Such particulate-laden liquids occur in a variety of microfluidic systems, one example being a system that sorts cells or large biomolecules for analysis. In comparison with the linear actuator of the preceding article, the bending actuator would be smaller and less massive. The combination of increased stroke, smaller mass, and smaller volume would be obtained at the cost of decreased actuation force: The proposed actuator would generate a force in the approximate range of 1 to 4 N, the exact amount depending on operating conditions and details of design. This level of actuation force would be too low to enable the valve to handle a fluid at the high pressure level mentioned in the preceding article. The proposal encompasses two alternative designs one featuring a miniature piezoelectric bimorph actuator and one featuring a thick-film unimorph piezoelectric actuator (see figure). In either version, the valve would consume a power of only 0.01 W when actuated at a frequency of 100 Hz. Also, in either version, it would be necessary to attach a soft elastomeric sealing ring to the valve seat so that any particles that settle on the seat would be pushed deep into the elastomeric material to prevent or reduce leakage. The overall dimensions of the bimorph version would be 7 by 7 by 1 mm. The actuator in this version would generate a force of 1 N and a stroke of 10 m at an applied potential of 150 V. The actuation force would be sufficient to enable the valve to handle a fluid pressurized up to about 50 psi (approximately equal to 0.35 MPa). The overall dimensions of the unimorph version would be 2 by 2 by 0.5 mm. In this version, an electric field across the piezoelectric film on a diaphragm would cause the film to pull on, and thereby bend, the diaphragm. At an applied potential of 20 V, the actuator in this version would generate a stroke of 10 micrometers and a force of 0.01 N. This force level would be too low to enable handling of fluids at pressures comparable to those of the bimorph version. This version would be useful primarily in microfluidic and nanofluidic applications that involve extremely low differential pressures and in which there are requirements for extreme miniaturization of valves. Examples of such applications include liquid chromatography and sequencing of deoxyribonucleic acid.

Yang, Eui-Hyeok↗

Waterhammer Transient Simulation and Model Anchoring for the Robotic Lunar Lander Propulsion System

Waterhammer transients have the potential to adversely impact propulsion system design if not properly addressed. Waterhammer can potentially lead to system plumbing, and component damage. Multi-thruster propulsion systems also develop constructive/destructive wave interference which becomes difficult to predict without detailed models. Therefore, it is important to sufficiently characterize propulsion system waterhammer in order to develop a robust design with minimal impact to other systems. A risk reduction activity was performed at Marshall Space Flight Center to develop a tool for estimating waterhammer through the use of anchored simulation for the Robotic Lunar Lander (RLL) propulsion system design. Testing was performed to simulate waterhammer surges due to rapid valve closure and consisted of twenty-two series of waterhammer tests, resulting in more than 300 valve actuations. These tests were performed using different valve actuation schemes and three system pressures. Data from the valve characterization tests were used to anchor the models that employed MSCSoftware.EASY5 v.2010 to model transient fluid phenomena by using transient forms of mass and energy conservation. The anchoring process was performed by comparing initial model results to experimental data and then iterating the model input to match the simulation results with the experimental data. The models provide good correlation with experimental results, supporting the use of EASY5 as a tool to model fluid transients and provide a baseline for future RLL system modeling. This paper addresses tasks performed during the waterhammer risk reduction activity for the RLL propulsion system. The problem of waterhammer simulation anchoring as applied to the RLL system is discussed with results from the corresponding experimental valve tests. Important factors for waterhammer mitigation are discussed along with potential design impacts to the RLL propulsion system.

Stein, William B.↗

NASA Manufacturing and Test Requirements for Normally Closed Pyrovalves for Hazardous Flight Systems Applications

Pyrovalves (figure 1, Basic Pyrovalve Design and Features,) are typically lighter, more reliable, and in most cases less expensive than other types of valves. They also consume less electrical power. They are single-use devices that are used in propulsion systems to isolate propellants or pressurant gases. These fluids may be hazardous because of their toxicity, reactivity, temperature, or high pressure. Note that in the simplified block diagram below not all detail features are shown so that those of major interest are more prominent. The diagram is provided to point out the various features that are discussed in this Specification. Features of some NC parent metal valve designs may differ. In 2013, the NESC concluded an extensive study of the reliability and safety of NC parent metal valves used in payloads carried aboard ELVs. The assessment successfully evaluated technical data to determine the risk of NC parent metal valve leakage or inadvertent activation in ELV payloads. The study resulted in numerous recommendations to ensure personnel and hardware/facility safety during ground processing of ELV payloads. One of those recommendations was to establish a NASA specification for NC parent metal valves. This Specification is a result of that recommendation, which is documented in NESC-RP-10-00614.

McDougle, Stephen H.↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

The Iodine Satellite (iSat) Propellant Feed System - Design and Demonstration

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm3 and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high Delta V maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. One of the systems under development to support such a technology is the propellant feed system, which must be capable of storing solid iodine propellant, applying heat to sublime the stored solid into the vapor phase, and then control the flow of low-pressure gaseous iodine to both the thruster and cathode. In a test conducted in 2016, a first-generation iodine propellant feed system was integrated with a cathode and Hall thruster. While this test had to be terminated, the feed system in this first test was able to support both cathode and integrated cathode and thruster operation prior to the termination of the test. In the present paper, we describe work performed since that initial integrated test. The effort uses lessons learned from the previous integrated test, retiring risk associated with the iodine propellant feed system, answering open design-space questions, and demonstrating iodine flow control in an integrated system. The work is undertaken at both the component level and then at the integrated subsystem level to systematically improve the feed system design, improving the hardware fidelity so the appearance and operation of the system are as flight-like as possible. At the component level, the work focuses on the propellant tank, the feed system tubing, the valves used to control the flow to the cathode and thruster, and the heaters that maintain the temperature of the flowpaths and keep iodine from redepositing and clogging the system. Work on the propellant reservoir focuses on fabricating a tank that matches the geometry of the flight design, which allows for the identification of flight tank fabrication issues that may arise and permits thermal testing of a tank possessing the same size and thermal mass as the flight design, which can be used to anchor thermal modeling of the component. This is critical for finalizing the tank heater power requirements that feed into the heater design. All metallic materials in the feed system are hastelloy or Inconel, as these materials are resistant to chemical attack by the highly-reactive iodine vapor. The tubing in the iodine feed system must possess ports to permit a neutral gas purge of the system that clear impurities after iodine is loaded into the propellant tank. A procedure is discussed whereby these ports are crimped and sealed after the purge process is completed so as to not re-expose the iodine system to air. The valves are a critical component for control of the flow to the thruster and the cathode. Significant effort has gone into upgrading the materials of the valves to make them more resistant to chemical attack and into developing an understanding of the use of these valves during the startup and operation of the cathode and thruster. The heaters that line the entire feed system are designed to draw minimal power from the power processing unit (PPU) while still having the capacity to maintain all the feed system components at the temperatures required to discourage iodine deposition inside components downstream of the propellant tank exit. The heaters possess two separate resistive traces, giving the design redundancy should a failure occur in the primary heater circuit of one of the heater zones. The task of operating a feed system in conjunction with a thruster and cathode is undertaken in a series of sub-steps. The system is first assembled and operated on xenon gas, using the valves for cathode startup and thruster control based on measurement of the discharge current. After startup and control on xenon are demonstrated, the thruster will be transitioned to iodine operation, demonstrating thruster startup and feed system control while using a xenon-fed cathode. Finally, the last step is to integrate an iodine-compatible cathode with the system, demonstrate autonomous cathode start-up with open-loop control and thruster start-up with closed-loop control for multiple cycles.

Polzin, Kurt A.↗

Thermal design and validation of Mars 202 gas Dust Removal Tool (gDRT)

As part of the science goals for the planned Mars 2020 mission, two instruments, PIXL and SHERLOC, intend to study the Mars surface at a close scale. These two instruments are planned to be used on smooth rock surfaces that are free of dust and other particles. Such surfaces are prepared by using a drill with an abrading drill bit; residual dust and particles are then blown away using a compressed gas system—the Gas Dust Removal Tool (gDRT). Early in the design process a risk of valve leakage below the vendor’s -20C rating was identified. To mitigate this risk a parallel path was implemented: 1) qualify the valves to operate at -135C, and 2) develop thermal control capability to elevated temperatures in case qualification efforts are unsuccessful. While qualification efforts are ongoing, it is expected that the valves will be qualified to an operating temperature of -135C. In the event that qualification is not successful, thermal control has been realized via a thermally isolated valve configuration and thermostatically controlled heaters. Thermal testing of gDRT has validated this design and enabled thermal model correlation in order to provide more accurate survival energy predictions. The resulting energy consumption for heating the valves at the Jezero landing site represents a minimal impact to the Rover energy budget.

Novak, Keith↗

High Pressure Vent Line Mishap: Investigation Summary

During testing on the E-1 Test Stand, the High Pressure (HP) Liquid Hydrogen (LH) vent line was displaced off its supports, damaging the expansion joints (EJ), piping, and pipe supports of the line. The damage to the vent line is believed to have occurred during Cell 3 testing on Thursday, September 21, during the first test of the day. The fuel systems being used for Cell 3 testing are connected to the LP and HP LH Vent systems and are being used in Liquid Natural Gas (LNG) service. The Cell 3 interface bleed valve that discharges to the HP LH Vent system was inadvertently left at 100% open during the chill-in process for longer than the typical amount of time. Since this valve is usually at a lower set point or intermittently closed during the chill-in process, more than the typical amount of LNG flowed into the vent line as pre-test procedures continued as normal. The open bleed valve was noticed before test preparations were completed and prior to refilling of the HP LH Tank before test. The test sequence was started, run, and shutdown normally. Video of the flare stack showed an atypical discharge of liquid at the flare stack exit. Pressure downstream of the Cell 3 interface bleed valve (a valve connected to the southernmost part of the vent system) spiked to a higher-than-normal level. No evidence of damage was captured at the time of the event. The system was used in a typical fashion after the event and for 4 subsequent tests on Thursday and Friday, before the damage was observed. A drive-by inspection of the flare stack was performed on Friday (September 22nd) morning before sunrise and before test activities began, but no damage of the vent line was observed at that time. No abnormal system behavior was observed during testing on Friday. The damage was discovered and reported to NASA Test Operations on Monday, initiating the Incident Response Team. The Mishap appointment letter was issued September 27th to formally initiate the Mishap Investigation.

LNG↗

Engine control system having pressure-based timing

A control system for an engine having a first cylinder and a second cylinder is disclosed having a first engine valve movable to regulate a fluid flow of the first cylinder and a first actuator associated with the first engine valve. The control system also has a second engine valve movable to regulate a fluid flow of the second cylinder and a sensor configured to generate a signal indicative of a pressure within the first cylinder. The control system also has a controller that is in communication with the first actuator and the sensor. The controller is configured to compare the pressure within the first cylinder with a desired pressure and selectively regulate the first actuator to adjust a timing of the first engine valve independently of the timing of the second engine valve based on the comparison.

33 ADVANCED PROPULSION SYSTEMS↗

Two phase exhaust for internal combustion engine

An internal combustion engine having a reciprocating multi cylinder internal combustion engine with multiple valves. At least a pair of exhaust valves are provided and each supply a separate power extraction device. The first exhaust valves connect to a power turbine used to provide additional power to the engine either mechanically or electrically. The flow path from these exhaust valves is smaller in area and volume than a second flow path which is used to deliver products of combustion to a turbocharger turbine. The timing of the exhaust valve events is controlled to produce a higher grade of energy to the power turbine and enhance the ability to extract power from the combustion process.

33 ADVANCED PROPULSION SYSTEMS↗

Characterization of Engine Control Authority on HCCI Combustion as the High Load Limit is Approached

While the potential emissions and efficiency benefits of homogeneous charge compression ignition (HCCI) combustion are well known, realizing the potentials on a production intent engine presents numerous challenges. In this study we focus on characterizing the authority of the available engine controls as the high load limit of HCCI combustion is approached. The experimental work is performed on a boosted single-cylinder research engine equipped with direct injection (DI) fueling, cooled external exhaust gas recirculation (EGR), and a hydraulic valve actuation (HVA) valve train to enable the negative valve overlap (NVO) breathing strategy. Valve lift and duration are held constant while phasing is varied in an effort to make the results as relevant as possible to production intent cam-based variable valve actuation (VVA) systems on multi-cylinder engines. Results presented include engine loads from 350 to 650 kPa IMEPnet and manifold pressure from 98 to 190 kPaa at 2000 rpm. It is found that in order to increase engine load to 650 kPa IMEPnet, it is necessary to increase manifold pressure and external EGR while reducing the NVO duration. Both NVO duration and fuel injection timing are effective means of controlling combustion phasing, with NVO duration being a coarse control and fuel injection timing being a fine control. NOX emissions are low throughout the study, with emissions below 0.1 g/kW-h at all boosted HCCI conditions, while good combustion efficiency is maintained (>96.5%). Net indicated thermal efficiency increases with load up to 600 kPa IMEPnet, where a peak efficiency of 41% is achieved. Results of independent parametric investigations are presented on the effect of external EGR, intake effect of manifold pressure, and the effect of NVO duration. It is found that increasing EGR at a constant manifold pressure and increasing manifold pressure at a constant EGR rate both have the effect of retarding combustion phasing. It is also found that combustion phasing becomes increasingly sensitive to NVO duration as engine load increases. Finally, comparisons are made between three commonly used noise metrics (AVL noise meter, ringing intensity (RI), and maximum pressure rise rate (MPRR)). It is found that compared to the AVL noise meter, RI significantly underestimates combustion noise under boosted conditions.

control sensitivity↗

Dedicated EGR engine with dynamic load control

An internal combustion engine comprises a first engine bank and a second engine bank. A first intake valve is disposed in an intake port of a cylinder of the first engine bank, and is configured for metering the first flow of combustion air by periodically opening and closing according to a first intake valve lift and duration characteristic. A variable valve train control mechanism is configured for affecting the first intake valve lift and duration characteristic. Either a lift or duration of the first intake valve is modulated so as to satisfy an EGR control criterion.

42 ENGINEERING↗

Materials for Advanced Ultra-Supercritical (AUSC) Steam Turbines – AUSC Component Demonstration

The work by the United States Department of Energy (U.S. DOE)/Ohio Coal Development Office (OCDO) Advanced Ultra-Supercritical (AUSC) Steam Boiler and Turbine Materials Consortia from 2001 through September 2015 was primarily focused on lab scale and pilot scale materials testing. The field testing included air-cooled probes and steam-cooled “loops” that were installed into existing utility boilers to gain exposure of these materials to realistic conditions of high temperature and corrosion due to the constituents in the coal ash. Successful research and development resulted in identification of metallic alloy materials and fabrication processes suited for power generation applications with metal temperatures up to approximately 1472°F (800°C). These materials or alloys have shown, in extensive laboratory tests and shop fabrication studies, to have excellent applicability for high-efficiency low CO2 transformational power generation technologies. However, as valuable as these material field tests have been for obtaining information, their scale is significantly below that required to minimize the risk associated with a power company building a multi-billion-dollar AUSC power plant. To decrease the identified risk barriers to full-scale implementation of these advanced materials, the U.S. DOE/OCDO AUSC Steam Boiler and Turbine Materials Consortia identified the key areas of the technology that need to be tested at a larger scale. Based upon the recommendations and outcome of a Consortia-sponsored workshop with the U.S.’s leading utilities, a Component Test (ComTest) Program for AUSC was proposed. The AUSC ComTest program would define materials performance requirements, plan for overall advanced system integration, design critical component tests, fabricate components for testing from advanced materials, and carry out the tests. A Pre-FEED evaluation of the test facility including the evaluation of three potential sites has been completed and previously reported. This report describes the Front-End Engineering Design (FEED), Detailed Engineering and the Environmental Assessment of the ComTest project. A significant amount of work was accomplished during Phase 1 to identity the components, as well as the component size, that would be manufactured from advanced alloys such as INCONEL 740H or HAYNES 282 alloys. Pathways to supply these components for ComTest have been identified as well as any further development that would be required. Every project of this nature has challenges and this project was no exception. The greatest challenge has been the project cost. Largely due to the infrastructure and balance of plant equipment upgrades required for Youngstown Thermal, the estimated project cost for the “base case” project was greater than originally budgeted. The project team spent a significant amount of time exploring opportunities for reducing the project cost. These options included: • Youngstown Thermal was exploring building a Combined Heat and Power (CHP) unit at their facility. The Youngstown Thermal staff, supported by Thermal Engineering Group, worked with the project team to determine whether it was economically desirable to supply ComTest with steam and other utilities, which would be supplied by the CHP project. • The project team also evaluated opportunities to optimize the project scope to reduce cost, such as reducing project scope by eliminating the Superheater Outlet Header test. • Southern Company had offered two sites as possible host locations for ComTest. Both sites had infrastructure in place such as steam from an existing unit, natural gas, cooling water and ample electrical power that would be required to be added at the Youngstown Thermal site. Utilizing this existing infrastructure could reduce the project cost. An additional project challenge was the departure of Babcock and Wilcox from the project in September 2016. This project setback was overcome by GE Power’s willingness to assume the design of the ComTest superheater. Since the project could not proceed without the superheater, this was a very positive project development. The merger of the GE Power and Alstom Power steam turbine divisions created synergies leading to the conclusion that instead of building a small-scale turbine, a more practical and useful endeavor would be to validate the manufacturing technology and supplier readiness for fabricating and machining full scale steam turbine components. Consequently, in March 2017, GE Power decided that a steam turbine test would not be necessary as part of the ComTest demonstration. Removing the operational testing of the steam turbine from ComTest further reduced the total project cost. Additionally, there was an opportunity to move ComTest from Youngstown Thermal to one of the Southern Company sites and operate ComTest at supercritical steam conditions and test the steam turbine main stop/control valve at a temperature and pressure that would be representative of the conditions of a high pressure steam turbine inlet valve. The steam could also possibly be returned to the host boiler so there would be no economic penalty of using this steam for ComTest. Relocating the project could further reduce the project cost due to the infrastructure already in place, including high pressure natural gas and cooling water, and the potential for heat integration, allowing a reduction of operating costs. Due to these potential cost reductions, it was decided to move the project away from Youngstown Thermal in March 2017. As integrating ComTest at the Southern Company site was explored, an issue was raised regarding the integration of the ComTest cycle with the plant steam cycle. Steam would be supplied to ComTest at nominally ~3865 psia and 775°F. The steam would be heated with natural gas to 1400°F for the valve test and then cooled to 1000°F so that the steam would be returned to the host boiler at the same conditions as their high pressure steam turbine inlet. However, there were concerns raised that the addition of the energy (natural gas) to the steam could trigger a New Source Review on the unit. Southern Company did not want ComTest to cause this review, so condensing all of the steam exiting ComTest and returning it to the host steam cycle as condensate was explored to insure there would be no implication that ComTest was adding energy to the host plant’s steam cycle. Ultimately, Southern Company decided that they wanted to “decouple” ComTest from the operating unit, making ComTest self-supporting, similar to the Youngstown Thermal “base case.” Without the steam turbine, the project team reached a consensus that operating the ComTest Superheater and steam turbine valves at the typical pressure of a package boiler (~1000 psig) would not generate enough useful technical information to justify the cost of the test. Therefore, it was decided in the December 2017 project quarterly meeting to cancel the operational phase of ComTest. Throughout the engineering phase of ComTest, manufacturing and supply chain challenges were identified. When GE Power recommended dropping the steam turbine test from ComTest, they identified many important manufacturing issues that should be evaluated and demonstrated. Other challenges had been raised by the GE Power group designing the superheater as well as those engineering components such as pressure relief and steam turbine bypass valves. In the December 2017 meeting, the project team decided that it was more beneficial to the AUSC technology to pursue these manufacturing and supply chain issues as Phase 2 of the ComTest project. This report is organized in the following manner: • Section 2 discusses the ComTest project background and organization. • Section 3 discussed project management. • Section 4 discusses the design of the ComTest AUSC components – the Superheater, steam turbine and Superheater Outlet Header. • Section 5 discusses the implementation of ComTest at Youngstown Thermal and the Southern Company site. • Section 6 discusses the development of the AUSC Supply Chain • Section 7 discusses the recommended plan for Phase 2 of ComTest

01 COAL, LIGNITE, AND PEAT↗

Flow and pressure estimators in a waste heat recovery system

An apparatus includes a pump circuit structured to receive pump data indicative of an operating characteristic of a pump feeding a fluid to a waste heat recovery (WHR) system; a flow circuit structured to receive valve position data indicative of a position of a valve downstream of the pump, estimate a flow rate of the fluid exiting the pump, and estimate the flow rate of the fluid exiting the valve; and a pressure circuit structured to receive pressure data indicative of the pressure of the fluid exiting the valve, estimate a change in pressure of the fluid across the WHR system, and determine a pressure of the fluid in a hot section of the WHR system based on the pressure of the fluid exiting the valve and the change in the pressure of the fluid across the WHR system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cooler for optics transmitting high intensity light

A system and an apparatus having an optic and a cooling system for cooling the optic. In one example an optically addressed light valve forms the optic. The cooling system includes first and second windows on opposing surfaces of the optically addressed light valve which constrain a cooling fluid to flow over the opposing surfaces. The fluid pressure outside the optically addressed light valve is low enough that it does not compress a liquid crystal gap of the optically addressed light valve. The cooling fluid is also transparent to a high powered light beam which is projected through the first and second windows, and also through the optically addressed light valve, during an additive manufacturing operation.

42 ENGINEERING↗