Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UTILITIES SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Experiments on solar photovoltaic power generation using concentrator and liquid cooling

Calculations and experimental data are presented leading to the development of a practical, economical solar photovoltaic power supply. The concept involves concentration of sunlight up to about 100 times normal solar intensity in a solar tracking collector and directing this to an array of solar cells. The cells are immersed in water circulated from a thermal reservoir which limits cell temperature rise to about 20 C above ambient during the day and which cools to ambient temperature during the night. Experiments were conducted on solar cells using a Fresnel lens for magnification, a telescope equatorial mount with clock drive, and tap water circulated through the solar cell holder cavity. Test results show that cells operate satisfactorily under these conditions. Power outputs achieved experimentally with cell optimized for 25 suns were linear with concentration to about 15 suns. Cells optimized for 100 suns were not available, but a corresponding linear relation of power output with concentration is anticipated. Test results have been used in a design analysis of the cost of systems utilizing this technique.

Beam, B. H.↗

Kinetics of the reaction OH + HNO3 yields H2O + NO3

The reaction OH + HN3 yields H2O + NO3 was studied over the temperature range 270-470 K in a flow system utilizing UV resonance fluorescence detection of OH. A temperature independent rate constant of (8.9 plus or minus 1.3) x 10 to the -14 cu cm/s was obtained, where the reported uncertainty represents a single standard deviation including estimates of systematic errors.

Margitan, J. J.↗

PERT TIME III

System utilizing time oriented network structure is automated aid for monitoring and scheduling various activities within particular project. Program provides management with means to evaluate accurately status of project and helps control time, cost, and manpower.

Source record↗

The application of digital computers to near-real-time processing of flutter test data

Procedures used in monitoring, analyzing, and displaying flight and ground flutter test data are presented. These procedures include three digital computer programs developed to process structural response data in near real time. Qualitative and quantitative modal stability data are derived from time history response data resulting from rapid sinusoidal frequency sweep forcing functions, tuned-mode quick stops, and pilot induced control pulses. The techniques have been applied to both fixed and rotary wing aircraft, during flight, whirl tower rotor systems tests, and wind tunnel flutter model tests. An hydraulically driven oscillatory aerodynamic vane excitation system utilized during the flight flutter test programs accomplished during Lockheed L-1011 and S-3A development is described.

Hurley, S. R.↗

All-weather ice information system for Alaskan arctic coastal shipping

A near real-time ice information system designed to aid arctic coast shipping along the Alaskan North Slope is described. The system utilizes a X-band Side Looking Airborne Radar (SLAR) mounted aboard a U.S. Coast Guard HC-130B aircraft. Radar mapping procedures showing the type, areal distribution and concentration of ice cover were developed. In order to guide vessel operational movements, near real-time SLAR image data were transmitted directly from the SLAR aircraft to Barrow, Alaska and the U.S. Coast Guard icebreaker Glacier. In addition, SLAR image data were transmitted in real time to Cleveland, Ohio via the NOAA-GOES Satellite. Radar images developed in Cleveland were subsequently facsimile transmitted to the U.S. Navy's Fleet Weather Facility in Suitland, Maryland for use in ice forecasting and also as a demonstration back to Barrow via the Communications Technology Satellite.

Gedney, R. T.↗

Sail intelligent terminal evaluation

Engineering assessments, recommendations, and equipment necessary to solve the operational problems are described, and operational flexibility of the intelligent terminal facility are extended. The following capabilities were considered: (1) the operation of at least two D/D stations and one remote graphics terminal simultaneously; (2) the capability to run plotter, AIDS and FORTRAN programs simultaneously; (3) simultaneous use of system utility routines of D/D stations and remote graphics terminal; (4) the capability to provide large volume hardcopy of data and graphics; and (5) the capability to eliminate or at least ease the current operation/programming problems with related labor costs. The overall intelligent terminal development, and plans guiding the analysis and equipment acquisitions were studied, and the assessments and analyses performed are also summarized.

Pruitt, J. L.↗

Feasibility study of microprocessor systems suitable for use in developing a real-time for the 4.75 GHz scatterometer

A class of signal processors suitable for the reduction of radar scatterometer data in real time was developed. The systems were applied to the reduction of single polarized 13.3 GHz scatterometer data and provided a real time output of radar scattering coefficient as a function of incident angle. It was proposed that a system for processing of C band radar data be constructed to support scatterometer system currently under development. The establishment of a feasible design approach to the development of this processor system utilizing microprocessor technology was emphasized.

Source record↗

Preliminary design study of a baseline MIUS

Results of a conceptual design study to establish a baseline design for a modular integrated utility system (MIUS) are presented. The system concept developed a basis for evaluating possible projects to demonstrate an MIUS. For the baseline study, climate conditions for the Washington, D.C., area were used. The baseline design is for a high density apartment complex of 496 dwelling units with a planned full occupancy of approximately 1200 residents. Environmental considerations and regulations for the MIUS installation are discussed. Detailed cost data for the baseline MIUS are given together with those for design and operating variations under climate conditions typified by Las Vegas, Nevada, Houston, Texas, and Minneapolis, Minnesota. In addition, results of an investigation of size variation effects, for 300 and 1000 unit apartment complexes, are presented. Only conceptual aspects of the design are discussed. Results regarding energy savings and costs are intended only as trend information and for use in relative comparisons. Alternate heating, ventilation, and air conditioning concepts are considered in the appendix.

Wolfer, B. M.↗

A fusible heat sink concept for extravehicular activity /EVA/ thermal control

This paper describes the preliminary design and analysis of a heat sink system, utilizing a phase change slurry material, to be used for astronaut and equipment cooling during manned space missions. During normal use, excess heat in the liquid cooling garment (LCG) coolant is transferred to a regenerable fusible heat sink. Recharge is accomplished by disconnecting the heat sink from the liquid cooling garment and placing it in an onboard freezer for simultaneous slurry refreeze and power supply recharge.

Roebelen, G. J., Jr.↗

Precision pointing of the international ultraviolet explorer /IUE/ scientific instrument using a gyroscopic and stellar reference

The Attitude Control System for the IUE spacecraft is described. The basic mission objectives are stated and a sequential discussion of the mission is presented. Desired accuracy for each mission phase is noted and where applicable the onboard control mechanization is shown. Sensors and actuator systems utilized by the control algorithms are described. Finally, onboard software is discussed to a level necessary to understand the prime mission mode operation.

Moore, J. V.↗

Development of an in situ calibration technique for combustible gas detectors

This paper describes the development of an in situ calibration procedure for combustible gas detectors (CGD). The CGD will be a necessary device for future space vehicles as many subsystems in the Environmental Control/Life Support System utilize or produce hydrogen (H2) gas. Existing calibration techniques are time-consuming and require support equipment such as an environmental chamber and calibration gas supply. The in situ calibration procedure involves utilization of a water vapor electrolysis cell for the automatic in situ generation of a H2/air calibration mixture within the flame arrestor of the CGD. The development effort concluded with the successful demonstration of in situ span calibrations of a CGD.

Shumar, J. W.↗

Damage-detection system for LNG carriers

System utilizes array of acoustical transducers to detect cracks and leaks in liquefied natural gas (LNG) containers onboard ships. In addition to detecting leaks, device indicates location and leak rate.

Mastandrea, J. R.↗

Helicopter position stabilizing system

System utilizes vertical gyroscope mounted on telescope handled by onboard observer, to help helicopter pilot fly precise circles over ground target without use of ground observer. Other possible uses include cargo discharge or pickup without ground controller, and hovering over invisible target with known coordinates.

Jenkin, K. R.↗

Solar heating system

A system is disclosed for using solar energy to heat the interior of a structure. The system utilizes a low cost solar collector to heat a recirculating air mass which then flows through a series of interconnected ducts and passageways without the use of exterior fans or blowers. Heat is transferred from the air mass to the structure's interior and the air mass is then reheated.

Jensen, R. N.↗

Ion tracking in an electrostatic potential distribution

An ion tracking system utilizing a single detector was designed to resolve two dimensional potential distributions in a vacuum. The ion detector consisted of a continuous dynode electron multiplier tube mounted behind a series of aperture plates. The detector was located on a track below a wedge shaped structure used to produce the desired potential distribution. A 150 volt electron beam aimed at selected regions, ionized the residual gas in the chamber. The ions were ejected from their source points by electrostatic forces causing them to drift downward toward the detector. Measurements of particle energy, detector position, and entry angle of the incoming particle flux were used to initialize a computer trajectory-tracing program. The program assumes a known theoretically calculated potential distribution near the wedge for computation of particle trajectories, providing a basis for evaluating the data. Special attention was given to characterization of the ion detector.

Ross, D. P.↗

Wideband electronics for ultrasonic tissue characterization

System utilizing natural ringing frequency of electronic circuit coupled to wideband transducer is used to determine frequency dependence of ultrasonic properties of tissue. With procedure frequency data can be obtained rapidly and inexpensively.

Gammell, P.↗

Thermal Storage Applications Workshop. Volume 2: Contributed Papers

The solar thermal and the thermal and thermochemical energy storage programs are described as well as the technology requirements for both external (electrical) and internal (thermal, chemical) modes for energy storage in solar power plants. Specific technical issues addressed include thermal storage criteria for solar power plants interfacing with utility systems; optimal dispatch of storage for solar plants in a conventional electric grid; thermal storage/temperature tradeoffs for solar total energy systems; the value of energy storage for direct-replacement solar thermal power plants; systems analysis of storage in specific solar thermal power applications; the value of seasonal storage of solar energy; criteria for selection of the thermal storage system for a 10 MW(2) solar power plant; and the need for specific requirements by storage system development teams.

Source record↗