Flow visualization equipment operating instructions Final report
Operation and components of density probe high voltage pulse generator, manipulator control, and pressure transducers used for flow visualization
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Operation and components of density probe high voltage pulse generator, manipulator control, and pressure transducers used for flow visualization
Conical bearing transducer suitable for gimbal axis support of gyro
Si semiconductor strain sensors and miniature pressure transducers for cryogenic pressure measurements
Reliable test method based on special strain gauge load transducer for embedment axial stress measurement in electronic modules
Laboratory calibration of piezoelectric transducer used as micrometeoroid impact gauge
Miniature resonator consisting of piezoelectric cadmium sulphide transducer evaporated onto single-crystal quartz wafer
We review historical and methodological approaches to measurements of intramuscular pressure (IMP) in humans. These techniques provide valuable measures of muscle tone and activity as well as diagnostic criteria for evaluation of exertional compartment syndrome. Although the wick and catheter techniques provide accurate measurements of IMP at rest, their value for exercise studies and diagnosis of exertional compartment syndrome is limited because of low frequency response and hydrostatic (static and inertial) pressure artifacts. Presently, most information on diagnosis of exertional compartment syndromes during dynamic exercise is available using the Myopress catheter. However, future research and clinical diagnosis using IMP can be optimized by the use of a miniature transducer-tipped catheter such as the Millar Mikro-tip.
STUDY DESIGN: Brief (30-second) isometric trunk extensions at 5%, 20%, 40%, 60%, and 80% of maximal voluntary contraction (MVC) and 3 minutes of prolonged trunk extension (20% MVC) in erect position were studied in nine healthy male subjects. OBJECTIVES: To investigate the intercorrelation between intramuscular pressure and tissue oxygenation of the paravertebral muscles during submaximal isometric contractions and further, to evaluate paravertebral electromyogram and intramuscular pressure as indicators of force development. SUMMARY OF BACKGROUND DATA: Local physiologic responses to muscle contraction are incompletely understood. METHODS: Relative oxygenation was monitored with noninvasive near-infrared spectroscopy, intramuscular pressure was measured with a transducer-tipped catheter, and surface electromyogram was monitored at three recording sites. RESULTS: The root mean square amplitudes of the paravertebral electromyogram (L4, left and right; T12, right) and intramuscular pressure measured in the lumbar multifidus muscle at L4 increased with greater force development in a curvilinear manner. A significant decrease in the oxygenation of the lumbar paravertebral muscle in response to muscle contraction was found at an initial contraction level of 20% MVC. This corresponded to a paravertebral intramuscular pressure of 30-40 mm Hg. However, during prolonged trunk extension, no further decrease in tissue oxygenation was found compared with the tissue oxygenation level at the end of the brief contractions, indicating that homeostatic adjustments (mean blood pressure and heart rate) over time were sufficient to maintain paravertebral muscle oxygen levels. CONCLUSION: At a threshold intramuscular pressure of 30-40 mm Hg during muscle contraction, oxygenation in the paravertebral muscles is significantly reduced. The effect of further increase in intramuscular pressure on tissue oxygenation over time may be compensated for by an increase in blood pressure and heart rate. Surface electromyogram amplitudes and intramuscular pressure can be used as indicators of paravertebral muscle force.
The present study was designed to validate our noninvasive ultrasonic technique (pulse phase locked loop: PPLL) for measuring intracranial pressure (ICP) waveforms. The technique is based upon detecting skull movements which are known to occur in conjunction with altered intracranial pressure. In bench model studies, PPLL output was highly correlated with changes in the distance between a transducer and a reflecting target (R2 = 0.977). In cadaver studies, transcranial distance was measured while pulsations of ICP (amplitudes of zero to 10 mmHg) were generated by rhythmic injections of saline. Frequency analyses (fast Fourier transformation) clearly demonstrate the correspondence between the PPLL output and ICP pulse cycles. Although theoretically there is a slight possibility that changes in the PPLL output are caused by changes in the ultrasonic velocity of brain tissue, the decreased amplitudes of the PPLL output as the external compression of the head was increased indicates that the PPLL output represents substantial skull movement associated with altered ICP. In conclusion, the ultrasound device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. Our technique makes it possible to analyze ICP waveforms noninvasively and will be helpful for understanding intracranial compliance and cerebrovascular circulation.
To assess the usefulness of intramuscular pressure (IMP) measurement for studying muscle function during gait, IMP was recorded in the soleus and tibialis anterior muscles of 10 volunteers during treadmill walking and running by using transducer-tipped catheters. Soleus IMP exhibited single peaks during late-stance phase of walking [181 +/- 69 (SE) mmHg] and running (269 +/- 95 mmHg). Tibialis anterior IMP showed a biphasic response, with the largest peak (90 +/- 15 mmHg during walking and 151 +/- 25 mmHg during running) occurring shortly after heel strike. IMP magnitude increased with gait speed in both muscles. Linear regression of soleus IMP against ankle joint torque obtained by a dynamometer produced linear relationships (n = 2, r = 0.97 for both). Application of these relationships to IMP data yielded estimated peak soleus moment contributions of 0.95-1.65 N . m/kg during walking, and 1.43-2.70 N . m/kg during running. Phasic elevations of IMP during exercise are probably generated by local muscle tissue deformations due to muscle force development. Thus profiles of IMP provide a direct, reproducible index of muscle function during locomotion in humans.
A system was refined for the determination of the bulk ultrasonic wave propagation velocity in small cortical bone specimens. Longitudinal and shear wave propagations were measured using ceramic, piezoelectric 20 and 5 MHz transducers, respectively. Results of the pulse transmission technique were refined via the measurement of the system delay time. The precision and accuracy of the system were quantified using small specimens of polyoxymethylene, polystyrene-butadiene, and high-density polyethylene. These polymeric materials had known acoustic properties, similarity of propagation velocities to cortical bone, and minimal sample inhomogeneity. Dependence of longitudinal and transverse specimen dimensions upon propagation times was quantified. To confirm the consistency of longitudinal wave propagation in small cortical bone specimens (< 1.0 mm), cut-down specimens were prepared from a normal rat femur. Finally, cortical samples were prepared from each of ten normal rat femora, and Young's moduli (Eii), shear moduli (Gij), and Poisson ratios (Vij) were measured. For all specimens (bone, polyoxymethylene, polystyrene-butadiene, and high-density polyethylene), strong linear correlations (R2 > 0.997) were maintained between propagation time and distance throughout the size ranges down to less than 0.4 mm. Results for polyoxymethylene, polystyrene-butadiene, and high-density polyethylene were accurate to within 5 percent of reported literature values. Measurement repeatability (precision) improved with an increase in the wave transmission distance (propagating dimension). No statistically significant effect due to the transverse dimension was detected.
Leg compression devices have been used extensively by patients to combat chronic venous insufficiency and by astronauts to counteract orthostatic intolerance following spaceflight. However, the effects of elastic and inelastic leggings on the calf muscle pump have not been compared. The purpose of this study was to compare in normal subjects the effects of elastic and inelastic compression on leg intramuscular pressure (IMP), an objective index of calf muscle pump function. IMP in soleus and tibialis anterior muscles was measured with transducer-tipped catheters. Surface compression between each legging and the skin was recorded with an air bladder. Subjects were studied under three conditions: (1) control (no legging), (2) elastic legging, and (3) inelastic legging. Pressure data were recorded for each condition during recumbency, sitting, standing, walking, and running. Elastic leggings applied significantly greater surface compression during recumbency (20 +/- 1 mm Hg, mean +/- SE) than inelastic leggings (13 +/- 2 mm Hg). During recumbency, elastic leggings produced significantly higher soleus IMP of 25 +/- 1 mm Hg and tibialis anterior IMP of 28 +/- 1 mm Hg compared to 17 +/- 1 mm Hg and 20 +/- 2 mm Hg, respectively, generated by inelastic leggings and 8 +/- 1 mm Hg and 11 +/- 1 mm Hg, respectively, without leggings. During sitting, walking, and running, however, peak IMPs generated in the muscular compartments by elastic and inelastic leggings were similar. Our results suggest that elastic leg compression applied over a long period in the recumbent posture may impede microcirculation and jeopardize tissue viability.(ABSTRACT TRUNCATED AT 250 WORDS).
INTRODUCTION: An interim resistance exercise device (iRED) was designed to provide resistive exercise as a countermeasure to spaceflight-induced loss of muscle strength and endurance as well as decreased bone mineral density. The purpose of this project was to compare foot-ground reaction force during iRED exercise in normal gravity (1 G) vs. microgravity (0 G) achieved during parabolic flight. METHODS: There were four subjects who performed three exercises (squat, heel raise, and deadlift) using the iRED during 1 G and 0 G at a moderate intensity (60% of maximum strength during deadlift exercise). Foot-ground reaction force was measured in the three orthogonal axes (x, y, z) using a force plate, and the magnitude of the resultant force vector was calculated (r = square root(x2 + y2 + z2)). Linear displacement (LD) was measured using a linear transducer. Peak force (Fpeak) and an index of total work (TWi) were calculated using a customized computer program. Paired t-tests were used to test if significant differences (p < or = 0.05) were observed between 1 G and 0 G exercise. RESULTS: Fpeak and TWi measured in the resultant axis were significantly less in 0 G for each of the exercises tested. During 0 G, Fpeak was 42-46% and TWi was 33-37% of that measured during 1 G. LD and average time to complete each repetition were not different from 1 G to 0 G. CONCLUSIONS: Crewmembers who perform resistive exercises during spaceflight that include the movement of a large portion of their body mass will require much greater external resistive force during 0 G than 1 G exercise to provide a sufficient stimulus to maintain muscle and bone mass.
Control of water and air in the root zone of plants remains a challenge in the microgravity environment of space. Due to limited flight opportunities, research aimed at resolving microgravity porous media fluid dynamics must often be conducted on Earth. The NASA KC-135 reduced gravity flight program offers an opportunity for Earth-based researchers to study physical processes in a variable gravity environment. The objectives of this study were to obtain measurements of water content and matric potential during the parabolic profile flown by the KC-135 aircraft. The flight profile provided 20-25 s of microgravity at the top of the parabola, while pulling 1.8 g at the bottom. The soil moisture sensors (Temperature and Moisture Acquisition System: Orbital Technologies, Madison, WI) used a heat-pulse method to indirectly estimate water content from heat dissipation. Tensiometers were constructed using a stainless steel porous cup with a pressure transducer and were used to measure the matric potential of the medium. The two types of sensors were placed at different depths in a substrate compartment filled with 1-2 mm Turface (calcined clay). The ability of the heat-pulse sensors to monitor overall changes in water content in the substrate compartment decreased with water content. Differences in measured water content data recorded at 0, 1, and 1.8 g were not significant. Tensiometer readings tracked pressure differences due to the hydrostatic force changes with variable gravity. The readings may have been affected by changes in cabin air pressure that occurred during each parabola. Tensiometer porous membrane conductivity (function of pore size) and fluid volume both influence response time. Porous media sample height and water content influence time-to-equilibrium, where shorter samples and higher water content achieve faster equilibrium. Further testing is needed to develop these sensors for space flight applications.
A novel cryogenic capacitive pressure transducer was developed.
An in-service health monitoring system is needed for steam pipes to track through their wall the condensation of water. The system is required to measure the height of the condensed water inside the pipe while operating at temperatures that are as high as 250 deg. C. The system needs to be able to make real time measurements while accounting for the effects of cavitation and wavy water surface. For this purpose, ultrasonic wave in pulse-echo configuration was used and reflected signals were acquired and auto-correlated to remove noise from the data and determine the water height. Transmitting and receiving the waves is done by piezoelectric transducers having Curie temperature that is significantly higher than 250 deg. C. Measurements were made at temperatures as high as 250 deg. C and have shown the feasibility of the test method. This manuscript reports the results of this feasibility study.
An experimental campaign was conducted on a 7-degree half-angle cone in the NASA Langley Research Center 20-Inch Mach 6 Wind Tunnel to examine the influence of arrays of regularly spaced roughness elements on instability growth and transition. The primary element shape was a pair of elliptical planform ramps that were inclined at equal and opposite angles with respect to the local streamwise direction. The element shapes were designed to induce transient growth disturbances that would lead to sustained azimuthal modulation of the boundary layer flow while limiting the nearfield disturbances to avoid an immediate, i.e., effective tripping of the boundary layer. The bulk of the run matrix consisted of testing different element height sat free stream unit Reynolds numbers ranging from 9.8 to 13.1 million per meter. Other element shapes previously designed for tripping hypersonic boundary layers were also implemented. The model was instrumented with surface mounted Kulite ® and PCB ® pressure transducers and thermocouples. Spectra from the PCBs ® indicated clear suppression of the second-mode instability; however, neither the PCB ® spectra nor the heat transfer data presented strong evidence for delayed turbulent flow. Complementary stability computations likewise demonstrated second-mode reduction, particularly just downstream of the roughness, but also revealed a rise in first mode (streak-instability) amplitudes from the baseline that was likely responsible for the earlier transition observed for taller roughness cases.
An experimental campaign was conducted on a 7-degree half-angle cone in the NASA Langley Research Center 20-Inch Mach 6 Wind Tunnel to examine the influence of arrays of regularly spaced roughness elements on instability growth and transition. The primary element shape was a pair of elliptical planform ramps that were inclined at equal and opposite angles with respect to the local streamwise direction. The element shapes were designed to induce transient growth disturbances that would lead to sustained azimuthal modulation of the boundary layer flow while limiting the nearfield disturbances to avoid an immediate, i.e., effective tripping of the boundary layer. The bulk of the run matrix consisted of testing different element height sat free stream unit Reynolds numbers ranging from 9.8 to 13.1 million per meter. Other element shapes previously designed for tripping hypersonic boundary layers were also implemented. The model was instrumented with surface mounted Kulite ® and PCB ® pressure transducers and thermocouples. Spectra from the PCBs ® indicated clear suppression of the second-mode instability; however, neither the PCB ® spectra nor the heat transfer data presented strong evidence for delayed turbulent flow. Complementary stability computations likewise demonstrated second-mode reduction, particularly just downstream of the roughness, but also revealed a rise in first mode (streak-instability) amplitudes from the baseline that was likely responsible for the earlier transition observed for taller roughness cases.