Experimental Characterization and Modeling of Thermal Battery Insulation Materials.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Conventional UO{sub 2} nuclear fuel is susceptible to oxidation via the formation of hyperstoichiometric uranium dioxide (UO{sub 2+x}) when exposed to air or high temperature water vapor in the event of a cladding breach during operation or storage. Below 1130 deg. C intermediate oxides U{sub 4}O{sub 9} and U{sub 3}O{sub 7} form; which degrades the thermal conductivity of the fuel. Understanding how the thermal conductivity degrades as a function of oxygen content and phase fractions is an important engineering problem for future fuel performance codes for safe and efficient reactor operation. (authors)
Explore the source record for details and available documents.
The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 degrees Centigrade and the heater power goal is to be within 5 percent of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.
International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.
The Fast Auroral SnapshoT explorer (FAST) spacecraft, the second of NASA's Small Explorer (SMEX) series of scientific satellites, was launched on August 21, 1996 by a Pegasus XL launch vehicle. Due to slightly higher than expected temperatures during early orbit operations, an extensive thermal model correlation effort was undertaken to understand and characterize FAST's thermal performance in order to properly orient the spacecraft's attitude during its mission. FAST's thermal design and the on-orbit thermal model correlation and resolution are described. Finally, the correlated model's predictions are compared with nine months of flight data.
Thermal comfort is a decisive factor for the well-being, productivity, and overall satisfaction of commercial building occupants. Many commercial building automation systems either use a fixed zone-wide temperature set-point for all occupants or they rely on extensive sensor deployments with frequent online interaction with occupants. This results in inadequate comfort levels or significant training effort from users, respectively. However, the increasing ubiquity of cheap, depth-based occupancy tracking systems has enabled an improvement in inferential capabilities. We propose the novel system OccuTherm to model thermal comfort of occupants. We conducted a laboratory study with 77 participants to collect data for the implementation of a thermal comfort model that derives thermal comfort using the human body shape. Based on the comparison with model baselines and ablations, we show that our approach infers thermal comfort of individuals with 60 % accuracy when body shape information is taken into account; 6 % more than state-of-the-art approaches. We make our code, mobile app, datasets, and models freely available.
Building thermal models, which characterize the properties of a building’s envelope and thermal mass, are essential for accurate indoor temperature and cooling/heating demand prediction. Because of their flexibility and ease of use, data-driven models are increasingly used. Here, this study compared and analyzed the performance of gray-box (resistance-capacitance) and black-box (recurrent neural network) models for predicting indoor air temperature in a real multi-zone commercial building. The developed resistance-capacitance model served as a benchmark model for which full sets of temporal data and building information were used as inputs. The recurrent neural network models were trained and tested assuming various available types and amounts of temporal data and known building physical information to investigate the effects of data and information availability. Feature importance analysis was conducted to select the key variables for different prediction targets under different scenarios. This research provides guidance in selecting an appropriate building thermal response modeling method based on the measured data availability, building physical information, and application.
An algorithm and supporting database for rapid thermal repository loading calculation was implemented in CYDER. This algorithm employs a Specific Temperature Change (STC) method and has resulted from combining detailed spent nuclear fuel composition data with a detailed thermal repository performance analysis tool from Lawrence Livermore National Laboratory (LLNL), Argonne National Laboratory (ANL), and the Used Fuel Disposition (UFD) campaign. By abstraction of and benchmarking against these detailed thermal models, CYDER captures the dominant physics of thermal phenomena affecting repository capacity in various geologic media and as a function of spent fuel composition. Abstraction based on detailed computational thermal repository performance calculations with the LLNL semi-analytic model has resulted in implementation of the STC estimation algorithm and a supporting reference dataset. This method is capable of rapid estimation of temperature increase near emplacement tunnels as a function of waste composition, limiting radius, waste package spacing, near field thermal conductivity and near field thermal diffusivity. The sensitivity analyses and validation efforts conducted in this work demonstrate the capability of the CYDER tool to provide repository capacity and performance metrics in the context of dynamic fuel cycle.
Large Liquid Hydrogen (LH2) storage tanks are vital infrastructure for NASA. Eventually, air may leak into the evacuated and perlite filled annular region of these tanks. Although the vacuum level is monitored in this region, the extremely cold temperature causes all but the helium and neon constituents of air to freeze. A small, often unnoticeable pressure rise is the result. As the leak persists, the quantity of frozen air increases, as does the thermal conductivity of the insulation system. Consequently, a notable increase in commodity boil-off is often the first indicator of an air leak. Severe damage can result from normal draining of the tank. The warming air will sublimate which will cause a pressure rise in the annulus. When the pressure increases above the triple point, the frozen air will begin to melt and migrate downward. Collection of liquid air on the carbon steel outer shell may chill it below its ductility range, resulting in fracture. In order to avoid a structural failure, as described above, a method for the safe removal of frozen air is needed. A thermal model of the storage tank has been created using SINDA/FLUINT modeling software. Experimental work is progressing in an attempt to characterize the thermal conductivity of a perlite/frozen nitrogen mixture. A statistical mechanics model is being developed in parallel for comparison to experimental work. The thermal model will be updated using the experimental/statistical mechanical data, and used to simulate potential removal scenarios. This paper will address methodologies and analysis techniques for evaluation of two proposed air removal methods.
An empirical heating model, thermal protection system unit weight correlation, and trajectory analysis were used to develop a computation procedure for studying the sensitivity of thermal protection system weights to variations in pertinent trajectory parameters. The analytical techniques used in developing this computer program are described. Application of the analysis to a Space Shuttle Orbiter configuration was performed to demonstrate gross thermal protection system weight trends with selected entry trajectory parameters.