Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

A Retrospective Analysis of Distributed Solar Interconnection Timelines and Related State Mandates

Most distributed residential photovoltaic (PV) systems must secure an interconnection agreement prior to operation that ensures the local electrical system will operate safely within the broader electrical grid. PV installers generally submit an interconnection application to the local utility that provides all the necessary details the utility needs to evaluate the proposed system. To encourage timely execution of this process, many states’ utility commissions have established mandates that limit the maximum number of days allowed for utility review and approval of interconnection for certain small, often residential applications. In this paper, we derive the median and range of cycle times for the pre-installation approval phase of the interconnection process (i.e., from application submission to approval by the utility) across 24 U.S. states, using a data set of approximately 170,000 projects. We evaluate the percentage of projects that are approved within respective state-mandated timelines from 2017– 2019. We further evaluate how timelines have evolved since 2012 for a subset of five states: Arizona, California, Colorado, New Jersey, and New York. The analyses are divided into two size ranges: systems that are ≤10 kilowatts (kW), and systems that are 11–50 kW.

14 SOLAR ENERGY↗

Estimation of solar photovoltaic energy curtailment due to volt–watt control

The widespread deployment of autonomous inverter‐based solutions for mitigating voltage and frequency excursions caused by high‐penetration photovoltaic (PV) systems has drawn increased attention due to their potential impact on PV production. It is now important to quantify the amount of solar energy curtailed as a result of the activation of inverter‐based grid support functions (GSFs). This study proposes a methodology for estimating the impact of volt–watt on customer PV energy curtailment using smart meter voltage data. This method estimates maximum possible curtailment for a given volt–watt curve based on the customer smart meter voltage during the time period of interest. This study compares the proposed methodology with field measurements using irradiance and customer inverter data from Hawaii as well as with results from a previous simulation‐driven study on the impact of advanced inverter GSF activation on PV energy curtailment. Results show that the proposed method for estimating lost PV production caused by volt–watt control aligns reasonably well with field measurements and computer simulations for hundreds of customers. The proposed method could be used to estimate customer energy curtailment, which could inform future compensation mechanisms for utilities leveraging customer‐sited resources to mitigate high voltage and defer infrastructure upgrades.

Emmanuel, Michael↗

Estimating and parameterizing mismatch power loss in bifacial photovoltaic systems

Nonuniform irradiance on the rear side of bifacial photovoltaic (PV) systems can cause additional mismatch loss, which may not be appropriately captured in PV energy production estimates and software. We evaluated several scenarios including horizontal single-axis tracking (HSAT) over natural ground-cover and rooftop-mounted systems over high albedo reflective roofs. We found mismatch losses of up to 1.5% annual loss for very close-mounted (0.15 m) rooftop systems, but losses for HSAT systems and high-ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically, the mean absolute difference of irradiance) to the resulting mismatch loss factor, with an R 2 better than .99. Furthermore, this approximate relationship was experimentally validated on mismatched PV modules, and it provides a basis for rapidly estimating bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM. Additional parameters investigated include (a) climate dependence and module orientation, which were not found to have a strong impact on bifacial mismatch losses and (b) PV module fill factor and bifaciality ratio, which did have a strong linear impact on mismatch losses.

14 SOLAR ENERGY↗

Incorporating energy justice into utility-scale photovoltaic deployment: A policy framework

Utility-scale photovoltaic (PV) installations made up 77 GW (6%) of installed capacity in the United States, as of the end of 2021. This will grow to more than 500 GW by 2050 under a mid-case projection or more than 800 GW if solar costs decline more rapidly. While utility-scale PV is projected to grow rapidly, to date, unlike energy efficiency or distributed PV, utility-scale PV has not been used to provide substantial financial benefits to underserved communities, either through ownership, financing of assets, or direct electricity bill reduction. We assess two mechanisms through which utility-scale PV could benefit underserved communities. We find that while a framework for direct electricity bill reduction can be meaningful to customers, this mechanism falls short of providing restorative justice via wealth creation for minority-owned businesses. In contrast, we find that a framework for procurement of utility-scale PV by public and private entities from PV projects that are financed, owned, and/or developed by minority-owned businesses can provide this restorative justice benefit, and thereby facilitate an equitable energy transition. We conclude with concrete recommendations for new policies and programs to ensure that the benefits of utility-scale PV systems are distributed to underserved communities.

14 SOLAR ENERGY↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks: Q1 2021

Based on our bottom-up modeling, the Q1 2021 PV and energy storage cost benchmarks are: $\$2.65$ per watt DC (WDC) (or $\$3.05$/WAC) for residential PV systems, 1.56/WDC (or $\$1.79$/WAC) for commercial rooftop PV systems, $\$1.64$/WDC (or $\$1.88$/WAC) for commercial ground-mount PV systems, $\$0.83$/WDC (or $\$1.13$/WAC) for fixed-tilt utility-scale PV systems, $\$0.89$/WDC (or $\$1.20$/WAC) for one-axis-tracking utility-scale PV systems, $\$30,326$-$\$33,618$ for a 7.15-kWDC residential PV system with 5 kW/12.5 kWh nameplate of storage, $\$2.04$ - $\$2.10$ million for a 1-MWDC commercial ground-mount PV system colocated with 600 kW/2.4 MWhusable of storage, $\$166$ - $\$167$ million for a 100-MWDC one-axis tracker PV system colocated with 60 MW/240 MWhusable of storage. Between 2020 and 2021, there were 3.3% ($\$0.0$9/W), 10.7% ($\$0.19$/W), and 12.3% ($\$0.13$/W) reductions (in 2020 USD) in the residential, commercial rooftop, and utility-scale (one-axis) PV system cost benchmarks respectively. Balance of system (BOS) costs have either increased or remained flat across sectors, year-on-year, unlike in previous benchmark reports, which generally have reported declining BOS costs. The increase in BOS cost has been offset by a 17% reduction in module cost. Overall, modeled PV installed costs across the three sectors have declined compared to our Q1 2020 system costs.

14 SOLAR ENERGY↗

Unfounded concerns about photovoltaic module toxicity and waste are slowing decarbonization

Unsubstantiated claims that fuel growing public concern over the toxicity of photovoltaic modules and their waste are slowing their deployment. Clarifying these issues will help to facilitate the decarbonization that our world depends on. Harnessing the potential of photovoltaic (PV) electricity generation is a key part of the transition to less carbon-intensive energy sources. The most recent energy production forecasts call for a massive 75 TW of global PV capacity by 2050 to have a chance of limiting global temperature rise to 1.5 °C and minimizing the impacts of climate change. This is more than a tenfold increase in the current manufacturing and deployment rate in less than 15 years. PV modules are new to many people, so increasing PV deployment has led to growing concerns about the quantity of waste that may arise from decommissioning them (if they are not recycled), and their potential to leach toxic metals. In conclusion, debunking misinformation about PV modules and PV module waste is the first step in addressing these concerns that are unnecessarily slowing PV deployment.

14 SOLAR ENERGY↗

Characterization of Performance Degradation Mechanisms in Low-Cost High Throughput DI-O3 Layer for Passivated Contact Silicon Solar Cells

Characterization and mitigating performance limiting defects in Silicon (Si) PV is one of key areas to be addressed to improve PV hardware costs and energy yield in order to lower the levelized cost of energy (LCOE) of installed PV cost to $0.02/kWh. As Si PV cells efficiencies have surpassed 22% and approaching 23%, the recombination at the metal contacts have become the focus point to be addressed. Passivated contact technologies—having a heterojunction with a band-gap larger than silicon between the metal and silicon—have emerged as a great potential for future highand ultrahigh-efficiency solar cells, as it concurrently reduces recombination and increases carrier selectivity, by incorporating thin films within the contact structure. Passivated contact Si solar cell technologies use a wide variety of tunnel layers—playing a crucial role to passivate metal contacts and tunnel charge carriers—including stoichiometric silicon oxide (SiO 2 ) grown by thermal oxidation and Low-Pressure Chemical Vapor Deposition (LPCVD) technique and silicon oxide (SiO x ) by hot nitric acid. However, thorough investigations on understanding the failure and performance degradation mechanisms associated with tunnel layers are still limited to date. Unlocking those degradation characteristics in crucial tunnel layers could improve the reliability and energy yield of passivated contact Si solar cells. Besides, the technique of growing aforementioned tunneling layers are low throughput, and requires high temperature processes and/or a vacuum environment. In this project, we investigated the performance degradation mechanisms of a low-cost high-throughput ozonated oxide (DI-O 3 ) tunnel layer for the passivated contact Si solar cells.

14 SOLAR ENERGY↗

Solar panel field array support system and apparatus and method for construction use

A combined PV panel assembly jig and forklift transport pallet is used to assemble PV panels for transport to a field array from a protected manufacturing environment. The panels are assembled to have adhesively applied rails for transport by a robotic drone on a ground-support rack and are pre-wired. The PV panel assembly jig holds, protects, and aligns the PV panels in an upside down position, opposite to their operational position, for ease of wiring in order to decrease the manual labor required in the field. Once the pallet is transported to the load station at the end of a row of solar panel racks in the field array, a robotic loader lifts the upside down PV panels from the combined PV panel assembly jig and forklift transport pallet in an arcing overhead motion that lifts, tilts, and deposits the PV panels in an upright position at the loading station of a railed rack support as ground-mounted in a solar panel field array.

14 SOLAR ENERGY↗

Economic Incentives for Agrivoltaics Systems with Commodity Crops in the Midwestern United States

Declining costs of photovoltaic (PV) technology and rising market and policy incentives are leading to the growing deployment of PV on cropland in the US Midwest, leading to concerns about the displacement of food and feed crop production. Agrivoltaic (AV) technology enables the dual use of land by co-locating PV energy and crop production, potentially reducing land-use competition with crop production. We develop a benefit-cost analysis framework to compare the net economic returns from AV to those with stand-alone PV and crop production on a representative field and show conditions under which AV can be more profitable for both a solar developer and a farmer. We integrate it with a crop and solar energy model to simulate the performance of various field designs and space and height configurations in AV systems to accommodate soybean production with conventional farm equipment under representative conditions in the US Midwest. We find that an AV system with soybean production is less profitable than PV alone for a solar developer due to the high capital costs of raising panel height, and less profitable for a farmer than leasing land for PV due to its adverse effects of shading on crop yield. We discuss the changes in technology and market prices of solar energy and soybeans that are necessary to make the AV system profitable for solar developers and farmers. We show that AV can worsen rather than mitigate the conflict between food crops and solar energy production in the Midwest.

14 SOLAR ENERGY↗

Solar Resource and Infrastructure Assessment for the Town of Blandford

This report is a solar resource and infrastructure assessment for the town of Blandford, Massachusetts. The assessment was funded through the National Renewable Energy Laboratory, Solar Energy Innovation Network (NREL SEIN) Solar in Rural Communities Program, as part of a project to develop a Community-Informed Proactive Solar Siting and Financing Model. As a first step, the project lead organization, UMass Clean Energy Extension prepared an assessment of existing infrastructure, resources, and potential solar development opportunities in participating municipalities, including Blandford. This assessment was designed to describe relevant bylaws and infrastructure within the town, identify the types of solar facilities that could be developed, and quantify the total space available for each type of facility. In this report, we reviewed existing electricity grid infrastructure, and the potential to interconnect additional solar facilities. At the present time, most distribution lines providing electricity to Blandford are over-saturated with authorized and proposed solar projects, and cannot accommodate additional solar projects to interconnect to the grid. We can expect significant upgrades to these circuits, if any of the in-process projects are to proceed, which might then free up additional capacity for new projects. There is one circuit which serves a section of North Blandford Road that is not over-saturated; for the immediate future, this is the most cost-effective location for new large-scale projects to be sited. Meanwhile, most three-phase lines could likely accommodate additional small-to-medium scale projects (under 200 kW), and most single-phase lines could likely accommodate additional projects under 50 kW in size. This description represents the local grid infrastructure as it is - planning for future scenarios of development could include recommendations for areas of grid infrastructure improvement to allow siting of distributed generation in preferred locations. Future scenarios may also include the addition energy storage and other "non-wires alternatives."

14 SOLAR ENERGY↗

Cadmium Telluride Accelerator Consortium (CTAC)

The United States is the leader in cadmium telluride (CdTe) photovoltaic (PV) manufacturing, and CdTe is the second most-deployed solar technology in the world. The CdTe Accelerator Consortium (CTAC) was formed to enhance U.S. technology leadership and competitiveness in CdTe photovoltaics (PV) including increasing cell efficiencies, decreasing module costs, and maintaining or increasing domestic CdTe PV material and module production. Leadership for the 3-year consortium was selected by an NREL team through a competitive solicitation. CTAC was formally announced on August 1st by U.S. Secretary of Energy Jennifer M. Granholm and U.S. Representative Marcy Kaptur at an event held at University of Toledo. We will give an overview of CTAC research directions along with their goals and activities. We can also discuss how CTAC relates to the National Renewable Energy Laboratory (NREL) and to the U.S. Manufacturing of Advanced Cadmium Telluride Photovoltaics Consortium (US-MAC). Visit our poster to find out who leads CTAC and how you can get involved.

costs↗

Validation of SolarWorld Modules at the NREL Regional Test Center Site (CRADA CRD-15-595 Final Report)

SolarWorld and the National Renewable Energy Laboratory (NREL) are entering into a cooperative research and development agreement (CRADA) in order to perform validation testing of SolarWorld’s Photovoltaic (PV) modules through the Department of Energy (DOE) Regional Test Center (RTC) program. This CRADA describes testing activities conducted specifically at the NREL-managed Colorado RTC site.

14 SOLAR ENERGY↗

On-Device Lead Detention for Perovskite Solar Cells

As the power conversion efficiency (PCE) of perovskite solar cells (PSCs) have reached above 25.5%, the commercialization of PSCs appears to be imminent due to its lower fabrication cost, simpler manufacturing processes, and larger processing area over Si-based solar cells that dominate the current photovoltaic (PV) market. While many efforts have focused on tackling the stability and scalability issues with promising advances, the potential lead (Pb) toxicity issue has remained a concern of PSCs. Unlike the metallic Pb, the Pb 2+ in perovskite generally exhibit high solubility in water. However, Pb 2+ has so far appeared to be a necessary component in all high-efficiency PSCs. Handful methods have been explored to mitigate the potential Pb2+ leaking issue, which can be generally categorized as physical encapsulation and our pioneering chemical absorption method, which was extended by others later. Since device damage is inevitable in outdoor conditions, physical encapsulation alone is not sufficient to mitigate the long-term risk of leakage of soluble Pb 2+ to the environment under severe weather conditions. As a result, the chemical absorption approach has recently attracted significant attention as a more effective solution to confine the potential lead leakage. Hence, it is of great value to develop durable and highly efficient Pb-absorbing components that can be conveniently mounted onto the standard PSC stack as an add-on accessory in line with the encapsulation of PSCs instead of modifying the standard device fabrication and/or device configuration.

14 SOLAR ENERGY↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

2022 Annual Technology Baseline (ATB) Cost and Performance Data for Electricity Generation Technologies

These data provide the 2022 update of the Electricity Annual Technology Baseline (ATB). Starting in 2015 NREL has presented the ATB, consisting of detailed cost and performance data, both current and projected, for electricity generation and storage technologies. The ATB products now include data (Excel workbook, Tableau workbooks, and structured summary csv files), as well as documentation and user engagement via a website, presentation, and webinar. Starting in 2021, the data are cloud optimized and provided in the OEDI data lake. The data for 2015 - 2020 are can be found on the NREL Data Search Page. The website documentation can be found on the ATB Website.

Array↗

Results from an International Interlaboratory Study on Light- and Elevated Temperature-Induced Degradation (LETID) in Solar Modules

This presentation reports recently submitted results from an international interlaboratory comparison study on light- and elevated temperature-induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection, and screen a large and diverse set of prototype modules for LETID. We summarize the range of observed degradation and provide initial conclusions on the reproducibility of results across labs. In LETID-sensitive modules, both open-circuit voltage (VOC) and short-circuit current (ISC) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the direct LETID-related losses. We summarize the conclusions drawn from the study, provide an update on a forthcoming standard technical specification for LETID testing of PV modules (IEC TS 63342 ED1), and discuss unresolved questions and potential future work on LETID in PV modules.

degradation↗