Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Towards Semantic Search in Building Sensor Data

This paper presents a search engine system for sensor time series data and metadata in the context of building management. It takes natural language queries as input, retrieves sensor time series data, ranks them with respect to their relevance to a given query, and visualizes the time series as search results. In addition, the system allows users to interact with the search results: they can define events of interest in the visualized results and search across sensor data for similar events, i.e., the search by example scheme. Quantitative evaluations and user studies demonstrate the value of this system for managing building sensor data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Interdigital Capacitance Sensor for Cable Insulation Test and Monitoring

A substantial body of work suggests feasibility to measure cable jacket and insulation conditions using various forms of interdigital capacitance (IDC) sensors. The sensors can either be used to manually test local cable conditions or as permanently installed sensors. Eligible cables subject to these measurements do not include shielded cables but the set of candidate cables is expanded from only unjacketed cables by the ability to assess insulation condition through the jacket. Dual gap IDC sensors are confirmed to be able to sense the insulation condition beneath a polymer jacket and, moreover, the IDC is the only known way to assess the insulation condition through the jacket. PNNL has filed a patent for this approach and is exploring commercial partnerships to exploit IDC technology for actionable field measurements.

NDE, cable, IDC, capacitance, permittivity, insula↗

Methods and apparatus for calibration and response time testing of level sensors

Systems and methods of diagnosing performance of a level sensor of a fluid test chamber, including a data acquisition and processing unit configured to receive output signals of one or more level sensors that are installed to a fluid chamber, the data acquisition and processing unit being configured to connect to the one or more level sensors to record and process the output signals to test operation of the one or more level sensors.

Hashemian, Alexander Hashem↗

Direct write sensors

A method of making an acoustic wave sensor includes the steps of providing a piezoelectric substrate layer and printing on the substrate layer a sensor layer comprising a first interdigitated acoustic wave transducer, a sensing film, and positioned on an opposing side of the sensing film from the first interdigitated acoustic wave transducer at least one selected from the group consisting of a second interdigitated acoustic wave transducer and a Bragg reflector. An insulation layer can be printed. An antenna can be printed in an antenna layer, and the insulation layer can be interposed between the antenna layer and the sensor layer. An electrical connection can be printed between the antenna and the first interdigitated acoustic wave transducer. An acoustic wave sensor is also disclosed.

McIntyre, Timothy J.↗

Distributed fiber-optic sensor network for sensing the corrosion onset and quantification

Materials, methods of making, and methods of sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion using a hierarchical sensor network A hierarchical sensor network for sensing liquid droplets with high spatial resolution as a signature of the on-set of corrosion, including an interrogation system; and an intermediate sensor array layer in communication with the interrogation system. The network includes an interrogation system and an intermediate sensor array layer in communication with the interrogation system.

Ohodnicki, Paul R.↗

Surface acoustic wave sensor for refrigerant leakage detection

A SAW sensor is optimized for detection of refrigerant leakage in a refrigerant system or other gases, vapors, explosives or chemicals of interest. The SAW sensor includes a piezoelectric substrate; an interdigitated transducer deposited on the piezoelectric substrate, the interdigitated transducer having an input portion that receives input surface acoustic waves and an output portion that emits output surface acoustic waves; and a refrigerant sensor film located between the input portion and the output portion of the interdigitated transducer, the refrigerant sensor film including a sorbent material that is selected for preferential adsorption of a target refrigerant over atmospheric gases. Adsorption of the target refrigerant by the sorbent material results in a frequency shift of a frequency of the output surface acoustic waves relative to a frequency of the input surface acoustic waves. The sorbent material may be a metal organic framework (MOF) material, a covalent organic framework (COF) material, a porous organic cage or organic macrocyles such as calix [n] arene and its related derivatives.

Kunapuli, Raghuit Prasad↗

Edge-computing with enhanced standoff sensors

A system senses analytes through one or more sensors that detect or measure a physical characteristic. The one or more sensor generate a spectroscopic-data signal corresponding to the detection. An edge device communicatively couples the one or more sensors that communicatively couples a wide-area network coupling a cloud service. The edge device includes a data acquisition device that receives spectroscopic data signals from the one or more sensor and a processor that processes the spectroscopic-data signals to identify an analyte. The edge device also includes a transceiver that transmits data identifying the analytes to the cloud service.

Passian, Ali↗

High-Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors - ASI Project Summary

The goal of this work is to investigate the performance of sapphire optical fiber temperature sensors and develop clad sapphire optical fibers for in-pile instrumentation. This work tests the distributed sensing performance of sapphire sensors by using optical backscatter reflectometry methods under combined radiation/temperature effects and high fluence. A series of irradiations will be completed to evaluate the effect of irradiation on sapphire optical fiber temperature sensors and to determine an operational limit for the sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques for incorporating sensors into apparatuses and systems

Methods of placing sensors in structures may involve placing first particles including a first material of the structure on or above a support surface. Second particles including a second, different material may be dispersed among the first particles at least within a transition region of the structure proximate to a location where a sensor is to be supported by the structure. A sensor may be placed in the location. The first particles of the first material may be fused to one another and to the second particles of the second material to form the structure with the sensor supported by the structure.

van Rooyen, Isabella J.↗

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a sensor for polypropylene degradation products.

This paper presents the development of a sensor to detect the oxidative and radiation induced degradation of polypropylene. Recently we have examined the use of crosslinked assemblies of nanoparticles as a chemiresistor-type sensor for the degradation products. We have developed a simple method that uses a siloxane matrix to fabricate a chemiresistor-type sensor that minimizes the swelling transduction mechanism while optimizing the change in dielectric response. These sensors were exposed with the use of a gas chromatography system to three previously identified polypropylene degradation products including 4-methyl-2-pentanone, acetone, and 2-pentanone. The limits of detection 210 ppb for 4-methy-2-pentanone, 575 ppb for 2-pentanone, and the LoD was unable to be determined for acetone due to incomplete separation from the carbon disulfide carrier.

36 MATERIALS SCIENCE↗

Compact orthogonal NMR field sensor

A Compact Orthogonal Field Sensor for emitting two orthogonal electro-magnetic fields in a common space. More particularly, a replacement inductor for existing NMR (Nuclear Magnetic Resonance) sensors to allow for NMR imaging. The Compact Orthogonal Field Sensor has a conductive coil and a central conductor electrically connected in series. The central conductor is at least partially surrounded by the coil. The coil and central conductor are electrically or electro-magnetically connected to a device having a means for producing or inducing a current through the coil and central conductor. The Compact Orthogonal Field Sensor can be used in NMR imaging applications to determine the position and the associated NMR spectrum of a sample within the electro-magnetic field of the central conductor.

47 OTHER INSTRUMENTATION↗

Effect of YSZ sintering temperature on mixed potential sensor performance

In this article, the influence of Yttria-Stabilized Zirconia (YSZ) sintering temperature on a Pt/YSZ/La{sub 0.8}Sr{sub 0.2}CrO{sub 3} mixed potential sensor performance is reported. The sintering temperature of YSZ was varied from 1000 to 1200 C. Mercury porosity measurements were performed to estimate the porosity and tortuosity of the YSZ sample as a function of sintering temperature. Further, the surface area of YSZ was computed by the BET method. After YSZ characterization, the unbiased and biased sensor response was recorded. The 1000 C sintered YSZ sample was taken as the reference for comparison purposes. Experimental results indicated a 30% reduction in porosity for the 1200 C sintered YSZ sample, accounting for a 14-fold increase in the sensor response rise time. In addition, for the same sample, a 13-fold increase in sensitivity was observed upon exposure to propylene (100 ppm), associated with a 76% reduction in surface area. The slow response time of the sensor with YSZ sintered at higher temperatures has been attributed to higher tortuosity (delay in gas permeation to the three phase interface). Whereas, reduced heterogeneous catalysis induced by lower surface area accounts for the rise in sensitivity levels. The optimum YSZ sintering temperature was found to lie between 1100 and 1150 C.

36 MATERIALS SCIENCE↗

Planar optical waveguide based sandwich assay sensors and processes for the detection of biological targets including early detection of cancers

An assay element is described including recognition ligands adapted for binding to carcinoembryonic antigen (CEA) bound to a film on a single mode planar optical waveguide, the film from the group of a membrane, a polymerized bilayer membrane, and a self-assembled monolayer containing polyethylene glycol or polypropylene glycol groups therein and an assay process for detecting the presence of CEA is described including injecting a possible CEA-containing sample into a sensor cell including the assay element, maintaining the sample within the sensor cell for time sufficient for binding to occur between CEA present within the sample and the recognition ligands, injecting a solution including a reporter ligand into the sensor cell; and, interrogating the sample within the sensor cell with excitation light from the waveguide, the excitation light provided by an evanescent field of the single mode penetrating into the biological target-containing sample to a distance of less than about 200 nanometers from the waveguide thereby exciting any bound reporter ligand within a distance of less than about 200 nanometers from the waveguide and resulting in a detectable signal.

60 APPLIED LIFE SCIENCES↗

Planar optical waveguide based sandwich assay sensors and processes for the detection of biological targets including protein markers, pathogens and cellular debris

An assay element is described including recognition ligands bound to a film on a single mode planar optical waveguide, the film from the group of a membrane, a polymerized bilayer membrane, and a self-assembled monolayer containing polyethylene glycol or polypropylene glycol groups therein and an assay process for detecting the presence of a biological target is described including injecting a biological target-containing sample into a sensor cell including the assay element, with the recognition ligands adapted for binding to selected biological targets, maintaining the sample within the sensor cell for time sufficient for binding to occur between selected biological targets within the sample and the recognition ligands, injecting a solution including a reporter ligand into the sensor cell; and, interrogating the sample within the sensor cell with excitation light from the waveguide, the excitation light provided by an evanescent field of the single mode penetrating into the biological target-containing sample to a distance of less than about 200 nanometers from the waveguide thereby exciting the fluorescent-label in any bound reporter ligand within a distance of less than about 200 nanometers from the waveguide and resulting in a detectable signal.

47 OTHER INSTRUMENTATION↗

Learning a detection map for a network of unattended ground sensors.

We have developed algorithms to automatically learn a detection map of a deployed sensor field for a virtual presence and extended defense (VPED) system without apriori knowledge of the local terrain. The VPED system is an unattended network of sensor pods, with each pod containing acoustic and seismic sensors. Each pod has the ability to detect and classify moving targets at a limited range. By using a network of pods we can form a virtual perimeter with each pod responsible for a certain section of the perimeter. The site's geography and soil conditions can affect the detection performance of the pods. Thus, a network in the field may not have the same performance as a network designed in the lab. To solve this problem we automatically estimate a network's detection performance as it is being installed at a site by a mobile deployment unit (MDU). The MDU will wear a GPS unit, so the system not only knows when it can detect the MDU, but also the MDU's location. In this paper, we demonstrate how to handle anisotropic sensor-configurations, geography, and soil conditions.

54 ENVIRONMENTAL SCIENCES↗

A scalable design of experiments framework for optimal sensor placement

Here, we present a scalable design of an experiments framework for sensor placement in systems described by partial differential equations (PDEs). In particular, we aim to compute optimal sensor locations by minimizing the uncertainty of parameters estimated from Bayesian inverse problems and where the system. The resulting problem is a computationally intractable mixed-integer nonlinear program constrained by PDEs. We approach this problem with two heuristics used in compressed sensing and optimal control literature: a sparsity-inducing approach and a sum-up rounding approach. We also investigate metrics to guide the design of experiments (the total flow variance and the A-optimal design criterion) and analyze the effect of different noise structures (white and colored). Using an application in natural gas pipelines, we conclude that the sum-up rounding approach approach gives the best results and produces shrinking gaps with increasing mesh resolution. We also observe that convergence for the white noise measurement error case is slower than for the colored noise case. For A-optimal design, the solution is close to a uniform distribution of sensors along the pipeline while for the flow variance design the distribution is unstructured.

42 ENGINEERING↗