Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURFACE CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Evaluation of laminar flow control systems concepts for subsonic commercial transport aircraft

An evaluation was made of laminar flow control (LFC) system concepts for subsonic commercial transport aircraft. Configuration design studies, performance analyses, fabrication development, structural testing, wind tunnel testing, and contamination-avoidance techniques were included. As a result of trade studies, a configuration with LFC on the upper wing surface only, utilizing an electron beam-perforated suction surface, and employing a retractable high-lift shield for contamination avoidance, was selected as the most practical LFC system. The LFC aircraft was then compared with an advanced turbulent aircraft designed for the same mission. This comparison indicated significant fuel savings and reduced direct operating cost benefits would result from using LFC.

Pearce, W. E.↗

Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas

Experiments have shown that it is feasible to use oxygen radicals (specifically, monatomic oxygen) from mild oxygen plasmas to remove organic contaminants and chemical fabrication residues from the surfaces of carbon nanotubes (CNTs) and metal/CNT interfaces. A capability for such cleaning is essential to the manufacture of reproducible CNT-based electronic devices. The use of oxygen radicals to clean surfaces of other materials is fairly well established. However, previously, cleaning of CNTs and of graphite by use of oxygen plasmas had not been attempted because both of these forms of carbon were known to be vulnerable to destruction by oxygen plasmas. The key to success of the present technique is, apparently, to ensure that the plasma is mild . that is to say, that the kinetic and internal energies of the oxygen radicals in the plasma are as low as possible. The plasma oxygen-radical source used in the experiments was a commercial one marketed for use in removing hydrocarbons and other organic contaminants from vacuum systems and from electron microscopes and other objects placed inside vacuum systems. In use, the source is installed in a vacuum system and air is leaked into the system at such a rate as to maintain a background pressure of .0.56 torr (.75 Pa). In the source, oxygen from the air is decomposed into monatomic oxygen by radio-frequency excitation of a resonance of the O2 molecule (N2 is not affected). Hence, what is produced is a mild (non-energetic) oxygen plasma. The oxygen radicals are transported along with the air molecules in the flow created by the vacuum pump. In the experiments, exposure to the oxygen plasma in this system was shown to remove organic contaminants and chemical fabrication residues from several specimens. Many high-magnification scanning electron microscope (SEM) images of CNTs were taken before and after exposure to the oxygen plasma. As in the example shown in the figure, none of these images showed evidence of degradation of CNT structures.

Petkov, Mihail↗

Plasma interactions and surface/material effects

A discussion on plasma interactions and surface/material effects is summarized. The key issues in this area were: (1) the lack of data on the material properties of common spacecraft surface materials; (2) lack of understanding of the contamination and decontamination processes; and (3) insufficient analytical tools to model synergistic phenomena related to plasma interactions. Without an adequate database of material properties, accurate system performance predictions cannot be made. The interdisciplinary nature of the surface-plasma interactions area makes it difficult to plan and maintain a coherent theoretical and experimental program. The shuttle glow phenomenon is an excellent example of an unanticipated, complex interaction involving synergism between surface and plasma effects. Building an adequate technology base for understanding and predicting surface-plasma interactions will require the coordinated efforts of engineers, chemists, and physicists. An interdisciplinary R and D program should be organized to deal with similar problems that the space systems of the 21st century may encounter.

Mandel, M.↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thiol-Functionalized Adsorbents through Atomic Layer Deposition and Vapor-Phase Silanization for Heavy Metal Ion Removal

The removal of toxic heavy metal ions from water resources is crucial for environmental protection and public health. In this study, we address this challenge by developing a surface functionalization technique for the selective adsorption of these contaminants. Our approach involves atomic layer deposition (ALD) followed by vapor-phase silanization of porous substrates. We utilized porous silica gel powder (similar to 100 mu m particles, 89 m 2 /g surface area, similar to 30 nm pores) as an initial substrate. This powder was first coated with similar to 0.5 nm ALD Al 2 O 3 , followed by vapor-phase grafting of a thiol-functional silane. The modified powder, particularly in acidic conditions (pH = 4), showed high selectivity in adsorbing Cd(II), As(V), Pb(II), Hg(II), and Cu(II) heavy metal ions in mixed ion solutions over common benign ions (e.g., Na, K, Ca, and Mg). Langmuir adsorption isotherms and breakthrough adsorption studies were conducted to assess heavy metal binding affinity and revealed the order of Cd(II) < Pb(II) < Cu(II) < As(V) < Hg(II), with a significantly higher affinity for As(V) and Hg(II) ions. Time-dependent uptake studies demonstrated rapid removal of heavy metal ions from aqueous environments, with Hg(II) exhibiting the fastest adsorption kinetics on thiol-modified surfaces. Finally, these findings highlight the potential of ALD and vapor-phase silanization to create effective adsorbents for the targeted removal of hazardous contaminants from water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isolating p- and n-Doped Fingers With Intrinsic Poly-Si in Passivated Interdigitated Back Contact Silicon Solar Cells

Polycrystalline silicon on silicon oxide (poly-Si/SiO x ) passivating contacts enable ultra high efficiency interdigitated back contact silicon solar cells. To prevent shunt between n- and p-type doped fingers, an insulating region is required between them. We evaluate the use of intrinsic poly Si for this isolation region. Interdigitated fingers were formed by plasma deposition of doped hydrogenated amorphous silicon through mechanically aligned shadow masks, on top of a full-area intrinsic amorphous silicon layer. High temperature annealing then crystallized the a-Si:H to poly Si and drove in the dopants. Two mechanisms were identified which cause contamination of the intrinsic poly Si gap during processing. During deposition of doped fingers, we show using secondary ion mass spectrometry and conductivity measurements that the intrinsic gap becomes contaminated by doped a-Si:H tails several nanometers thick to concentrations of ~10 20 cm -3 . Another source of contamination occurs during high-temperature annealing, where dopants desorb from doped regions and readsorb onto intrinsic a Si:H. Both pathways reduce the resistivity of the intrinsic gap from ~10 5 Ω·cm to ~10 -1 Ω·cm. We show that plasma etching of the a-Si:H surface before crystallizing with a capping layer can eliminate the contamination of the intrinsic poly-Si, maintaining a resistivity of ~10 5 Ω·cm. Lastly, this demonstrates masked plasma deposition as a dopant patterning method for Si solar cells.

14 SOLAR ENERGY↗

Shuttle orbiter - IUS/DSP satellite interface contamination study

The results of a contamination analysis on the Defense Support Program (DSP) satellite during launch and deployment by the Space Transportation System (STS) are presented. Predicted contaminant deposition was also included on critical DSP surfaces during the period soon after launch when the DSP is in the shuttle orbiter bay with the doors closed, the bay doors open, and during initial deployment. Additionally, a six sided box was placed at the spacecraft position to obtain directional contaminant flux information for a general payload while in the bay and during deployment. The analysis included contamination sources from the shuttle orbiter, IUS and cradle, the DSP sensor and the DSP support package.

Rantanen, R. O.↗

The Design of a Remotely Operated Shutter (ROS) for Thermal Vacuum Testing

Space-flight hardware is required to meet specific outgassing criteria under vacuum conditions in order to reduce the risk of contaminating sensitive optics and spacecraft components. Under certain circumstances, it is desirable to measure the contamination levels that are being released from all surfaces of the test payload. This certification is often accomplished with a Total Outgassing Measurement (TOM) box. The TOM box has one 103.2 square centimeter (16 square inch) opening and one 4.84 square centimeter (0.75 square inches) opening. The larger opening allows contaminants to easily escape the box during the hardware bakeout phase. The smaller opening provides a limited conductance path for outgassed contaminants during the certification phase. A Thermoelectric Quartz Crystal Microbalance (TQCM) monitors the contamination levels inside the box to provide the total outgassing measurement. During transition from the bakeout phase to the certification phase, the TOM box is reconfigured to close the larger opening. For previous certifications, the vacuum chamber was returned to ambient conditions and the larger conductance port was closed manually. The ROS system eliminates the need to enter the chamber by remotely closing the large TOM box opening. Substantial schedule and cost savings are achieved through the use of this system. The ROS system consists of three main components; a shutter, a motion actuator, and an actuator controller. Each of these components was selected or designed to operate in an extreme-temperature and vacuum environment while providing a high level of reliability. Different types of motion actuators were considered for driving the shutter. Design parameters for the actuator included material properties, force capability, reliability, and cost.

Hale, Kathleen L.↗

Design of high pressure oxygen filter for extravehicular activity life support system, volume 1

The experience of the National Aeronautics and Space Administration (NASA) with extravehicular activity life support emergency oxygen supply subsystems has shown a large number of problems associated with particulate contamination. These problems have resulted in failures of high pressure oxygen component sealing surfaces. A high pressure oxygen filter was designed which would (a) control the particulate contamination level in the oxygen system to a five-micron glass bead rating, ten-micron absolute condition (b) withstand the dynamic shock condition resulting from the sudden opening of 8000 psi oxygen system shutoff valve. Results of the following program tasks are reported: (1) contaminant source identification tests, (2) dynamic system tests, (3) high pressure oxygen filter concept evaluation, (4) design, (5) fabrication, (6) test, and (7) application demonstration.

Wilson, B. A.↗

A facility for the simulation of environmental parameters and qualification of flight thermal coatings

There is a continuing interest and need for investigation and development of, various paints, coatings, multi-layer insulation, and electrically conductive paints and coatings used for thermal control and electrical discharge of spacecraft surfaces. Degradation of these surfaces by solar-wind energy particles and ultraviolet irradiation, as well as contamination by the outgassing of materials used in conjunction or close proximity to these surfaces, continues to be a matter of concern. The following is a description of a facility with the capability of evaluating the synergistic effects encountered in the space environment. Actual flight qualification programs are also described.

Paczkowski, F. N.↗

Serrating Nozzle Surfaces for Complete Transfer of Droplets

A method of ensuring the complete transfer of liquid droplets from nozzles in microfluidic devices to nearby surfaces involves relatively simple geometric modification of the nozzle surfaces. The method is especially applicable to nozzles in print heads and similar devices required to dispense liquid droplets having precise volumes. Examples of such devices include heads for soft printing of ink on paper and heads for depositing droplets of deoxyribonucleic acid (DNA) or protein solutions on glass plates to form microarrays of spots for analysis. The main purpose served by the present method is to ensure that droplets transferred from a nozzle have consistent volume, as needed to ensure accuracy in microarray analysis or consistent appearance of printed text and images. In soft printing, droplets having consistent volume are generated inside a print head, but in the absence of the present method, the consistency is lost in printing because after each printing action (in which a drop is ejected from a nozzle), a small residual volume of liquid remains attached to the nozzle. By providing for complete transfer of droplets (and thus eliminating residual liquid attached to the nozzle) the method ensures consistency of volume of transferred droplets. An additional benefit of elimination of residue is prevention of cross-contamination among different liquids printed through the same nozzle a major consideration in DNA microarray analysis. The method also accelerates the printing process by minimizing the need to clean a printing head to prevent cross-contamination. Soft printing involves a hydrophobic nozzle surface and a hydrophilic print surface. When the two surfaces are brought into proximity such that a droplet in the nozzle makes contact with the print surface, a substantial portion of the droplet becomes transferred to the print surface. Then as the nozzle and the print surface are pulled apart, the droplet is pulled apart and most of the droplet remains on the print surface. The basic principle of the present method is to reduce the liquid-solid surface energy of the nozzle to a level sufficiently below the intrinsic solid-liquid surface energy of the nozzle material so that the droplet is not pulled apart and, instead, the entire droplet volume becomes transferred to the print surface. In this method, the liquid-solid surface energy is reduced by introducing artificial surface roughness in the form of micromachined serrations on the inner nozzle surface (see figure). The method was tested in experiments on soft printing of DNA solutions and of deionized water through 0.5-mm-diameter nozzles, of which some were not serrated, some were partially serrated, and some were fully serrated. In the nozzles without serrations, transfer was incomplete; that is, residual liquids remained in the nozzles after printing. However, in every nozzle in which at least half the inner surface was serrated, complete transfer of droplets to the print surface was achieved.

Kim, Chang-Jin "CJ"↗

Comprehensive Baseline Environmental Monitoring of an Interim Legacy Waste Store in Arid Zone Australia - 20062

Radionuclide containing soil and rubble from the clean-up of a former uranium, thorium and rare earth minerals processing research facility carried out in the early 50's and 60's is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to developing a final disposal pathway commensurate with waste acceptance criteria, a comprehensive baseline environmental monitoring has been carried out to establish the background radiation levels. The survey included in situ gamma scanning of the surface soil ({sup 238}U, {sup 232}Th, {sup 40}K), a laboratory analysis of 86 soil samples (from 0-20 cm depth), which involved XRF measurements (U, Th, and rare earth metals) and spectroscopic analysis ({sup 238}U, {sup 232}Th, {sup 226}Ra and daughter nuclides). A time series of radon concentration measurements in air was established, while soil radon ({sup 222}Rn) and thoron ({sup 220}Rn) flux measurements were undertaken at 18 different locations. The 2018 comprehensive baseline survey demonstrated radiation levels in the immediate vicinity of the Woomera interim waste store are typical background values of soil and rock. No contamination was detected. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rust transformation/rust compatible primers

Proper surface preparation has been the key to obtain good performance by a surface coating. The major obstacle in preparing a corroded or rusted surface is the complete removal of the contaminants and the corrosion products. Sandblasting has been traditionally used to remove the corrosion products before painting. However, sandblasting can be expensive, may be prohibited by local health regulations and is not applicable in every situation. To get around these obstacles, Industry developed rust converters/rust transformers and rust compatible primers (high solids epoxies). The potential use of these products for military equipment led personnel of the Belvoir Research, Development and Engineering Center (BRDEC) to evaluate the commercially available rust transformers and rust compatible primers. Prior laboratory experience with commercially available rust converters, as well as field studies in Hawaii and Puerto Rico, revealed poor performance, several inherent limitations, and lack of reliability. It was obvious from our studies that the performance of rust converting products was more dependent on the amount and type of rust present, as well as the degree of permeability of the coating, than on the product's ability to form an organometallic complex with the rust. Based on these results, it was decided that the Military should develop their own rust converter formulation and specification. The compound described in the specification is for use on a rusted surface before the application of an organic coating (bituminous compounds, primer or topcoat). These coatings should end the need for sandblasting or the removing of the adherent corrosion products. They also will prepare the surface for the application of the organic coating. Several commercially available rust compatible primers (RCP) were also tested using corroded surfaces. All of the evaluated RCP failed our laboratory tests for primers.

Emeric, Dario A.↗

Determination of space vehicle contamination

The contamination and degradation of externally exposed sensitive experimental and functional surfaces of the Skylab by the self-induced atmosphere surrounding the vehicle are studied. It is shown that the major contamination sources of long-term deposits on Skylab are primarily outgassing from nonmetallic coatings and rocket engine exhaust products. Analysis showed that the characteristic decay time of the outgassing source rate may be as long as 4100 hr, and that essentially 20% of RCS deposits that stick at temperatures of 0 C will remain after sublimating at a rate whose characteristic decay time is 72 hr.

Rantanen, R. O.↗

International Low-Earth-Orbit Spacecraft Materials Test Program Initiated for Better Prediction of Durability and Performance

Spacecraft in low Earth orbit (LEO) are subjected to many components of the environment, which can cause them to degrade much more rapidly than intended and greatly shorten their functional life. The atomic oxygen, ultraviolet radiation, and cross contamination present in LEO can affect sensitive surfaces such as thermal control paints, multilayer insulation, solar array surfaces, and optical surfaces. The LEO Spacecraft Materials Test (LEO-SMT) program is being conducted to assess the effects of simulated LEO exposure on current spacecraft materials to increase understanding of LEO degradation processes as well as to enable the prediction of in-space performance and durability. Using ground-based simulation facilities to test the durability of materials currently flying in LEO will allow researchers to compare the degradation evidenced in the ground-based facilities with that evidenced on orbit. This will allow refinement of ground laboratory test systems and the development of algorithms to predict the durability and performance of new materials in LEO from ground test results. Accurate predictions based on ground tests could reduce development costs and increase reliability. The wide variety of national and international materials being tested represent materials being functionally used on spacecraft in LEO. The more varied the types of materials tested, the greater the probability that researchers will develop and validate predictive models for spacecraft long-term performance and durability. Organizations that are currently participating in the program are ITT Research Institute (USA), Lockheed Martin (USA), MAP (France), SOREQ Nuclear Research Center (Israel), TNO Institute of Applied Physics (The Netherlands), and UBE Industries, Ltd. (Japan). These represent some of the major suppliers of thermal control and sensor materials currently flying in LEO. The participants provide materials that are exposed to selected levels of atomic oxygen, vacuum ultraviolet radiation, contamination, or synergistic combined environments at the NASA Lewis Research Center. Changes in characteristics that could affect mission performance or lifetime are then measured. These characteristics include changes in mass, solar absorptance, and thermal emittance. The durability of spacecraft materials from U.S. suppliers is then compared with those of materials from other participating countries. Lewis will develop and validate performance and durability prediction models using this ground data and available space data. NASA welcomes the opportunity to consider additional international participants in this program, which should greatly aid future spacecraft designers as they select materials for LEO missions.

Rutledge, Sharon K.↗

Plasma Surface Interactions: Predicting the Performance and Impact of Dynamic PFC Surfaces

The objective of this project is to develop, and integrate, high-performance simulation tools capable of predicting plasma-facing component (PFC) operating lifetime and the impact of the evolving surface morphology of tungsten-based PFCs on plasma contamination, including the dynamic recycling of fuel species and tritium retention, in future magnetic fusion devices. Establishing a fundamental physical understanding and developing predictive capabilities of plasma-surface interactions (PSI) requires simultaneously addressing complex and diverse physics occurring over a wide range of length (Angstroms to meters) and time (femtoseconds to years) scales, as well as integrating extensive physical processes across the plasma–surface interface. This requires development of not only detailed physics models and computational strategies at each scale, but also algorithms and methods to couple them effectively in a way that can be robustly validated. Deploying these tools requires the continued development and coupling of leadership-scale computational codes to describe the boundary plasma and the evolving PFC surface, as well as a host of simulations that bridge disparate scales to address complex physical and computational issues at the plasma–surface interface in multi-component materials systems for magnetic fusion energy development beyond ITER.

36 MATERIALS SCIENCE↗

Performance Restoration of Iron Electrodes by Polarity Reversal after Long-Term Surface Fouling in Wastewater Electrocoagulation

Iron electrocoagulation (Fe-EC) performance often declines with time, producing lower contaminant removal efficiencies and higher energy requirements due to formation of a fouling layer on the electrodes. Here, we investigate the formation of the fouling layer and the effectiveness of polarity reversal to restore the Fe-EC performance. A thin, porous iron oxide layer initially forms on the anode, thickening into a dense, over 150-μm thick crystalline layer after extended operation. This fouling layer restricts dissolution and diffusion of Fe ions into the bulk solution, thus increasing the anode potential required to maintain a desired electrical current and decreasing Faradaic efficiency. Polarity reversal applied when performance decline is observed effectively removes the fouling layer, thereby restoring Faradaic and contaminant removal efficiencies and decreasing energy consumption. Our findings suggest that gas generation at the cathode surface after polarity reversal causes removal of the fouling layer. This study enhances the current understanding of fouling-layer formation in Fe-EC and offers a practical approach, involving polarity reversal, to maintain electrode reactivity and optimal Fe-EC performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Nature and State of Groundwater Contamination at the Nevada National Security Site: What Have We Learned from Decades of Groundwater Analysis? - 20337

The regulatory framework for remediating radionuclide contamination from underground nuclear testing at the Nevada National Security Site (NNSS) is based on a combination of characterization and modeling studies, monitoring, and institutional controls [1]. Currently, tritium is the largest contributor (∼90%) to the estimated 44.6 million-curie radionuclide inventory resulting from underground testing [2]. Because of its short half-life (12.32 years), its relative contribution reduces below 10% of the total radiologic inventory over the next 120 years as a result of radioactive decay. Although tritium levels are observed well above the Safe Drinking Water Act (SDWA) maximum contaminant levels (MCLs) in groundwater, other radionuclides are well below their MCLs except within the nuclear test near-field (nuclear test cavity and chimney) environment. In fact, most device-derived radionuclides are below their MCL in groundwater even in samples collected from this near-field environment. The distribution of radionuclides following the nuclear detonation greatly influences the availability of potential contaminants for groundwater transport. Tritium is initially distributed in the gas phase, later as tritiated water in steam, and finally as liquid water, and is available to groundwater transport away from the near-field environment. Other radionuclides that are mobile in groundwater are {sup 14}C, {sup 36}Cl, {sup 99}Tc, and {sup 129}I though their radiologic inventory is small when compared to tritium. Many radionuclides (e.g. U, Pu, Am) are incorporated to a significant extent into the melt glass at the bottom of the cavity and are accessible to groundwater primarily through the slow process of glass dissolution. These radionuclides are also adsorbed to the surfaces of the crushed rock within the cavity and chimney which limits their migration in groundwater. Although colloid facilitated transport of radionuclides at the NNSS has been observed [3], radionuclide concentrations decrease with time and migration distances due to desorption and colloid filtration processes. Current studies indicate that radionuclides associated with colloids are unlikely to migrate downgradient from NNSS underground nuclear tests at concentrations above the SDWA MCL [4][5]. The results of over 50 years of sampling, along with an understanding of these post detonation processes, indicate that tritium is the only contaminant of concern downgradient of testing and that even tritium will not exceed its MCL in groundwater after ∼120 years. Although other longer-lived radionuclides may continue to be released slowly from the near-field environment they will likely never reach levels exceeding their MCLs in groundwater downgradient of the NNSS. Groundwater monitoring will continue to verify these observations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗