Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Rapid multidimensional data acquisition in scanning probe microscopy applied to local polarization dynamics and voltage dependent contact mechanics

A rapid multidimensional spectroscopic imaging approach in scanning probe microscopy is developed and applied to piezoresponse force spectroscopy. Evolution of resonance frequency, dissipation, and piezoresponse signal at each point during acquisition of local hysteresis loops provides information on polarization dynamics and voltage dependent contact mechanics of ferroelectric surfaces. The measurements illustrate significant frequency shifts during piezoresponse force spectroscopy, necessitating the use of frequency-tracking methods. The method is universal and can be extended to other scanning probe microscopy techniques. (C) 2008 American Institute of Physics.

Jesse, Stephen↗

Implementation on a desktop computer of the real time feedback control loop of a scanning probe microscope

A software package has been developed to implement the real time feedback control loop needed in scanning probe microscopy on a general purpose desktop computer of the current high-speed/multicore generation. The main features of the implementation of both the feedback loop and the control of the experiment on the same computer are discussed. The package can work with several general purpose data acquisition boards and can be extended in a modular way to further board models; timing performance has been tested with several hardware configurations and some applications common in scanning probe microscopy. The package is available under an Open Source license.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-scan measurement of conductance of a quartz crystal microbalance array coupled with resonant markers for biosensing in liquid phase

This work presents a method for sensing the viscoelastic property of liquid/solid interface using a quartz crystal microbalance (QCM) array. Each sensor in a QCM array has a unique resonant frequency and can be identified by a single-scan measurement of admittance (or impedance). The resonant frequency encoding at each sensor in an array was realized by connecting a capacitor with a known capacitance, called a resonant marker, to the sensor in series. Changes in the resonant frequency of all sensors in an array can be determined using an impedance analyzer and a program that determines the frequencies at which the conductance is at a local maximum. The sensing method allows every sensor output (resonant frequency) to be obtained without the use of time-consuming multiplexed hardware and software. Adsorptions of biomolecules by multiple sensor are monitored in the liquid phase to demonstrate the feasibility of frequency encoding using resonant markers and the single-scan measurement of conductance of a QCM array.

36 MATERIALS SCIENCE↗

A PORTABLE MICROWAVE INTERFERENCE SCANNING SYSTEM FOR NONDESTRUCTIVE TESTING OF MULTI-LAYERED DIELECTRIC MATERIALS

A portable, microwave interference scanning system, that can be used in situ, with one-sided, non-contact access, has been developed. It has demonstrated capability of damage detection on composite ceramic armor. Specimens used for validation included specially fabricated surrogates, and non-ballistic impact-damaged specimens. Microwave data results were corroborated with high resolution direct-digital x-ray imaging. Microwave interference scanning detects cracks, laminar features and material properties variations. This paper will present details of the system and discuss results obtained.

36 MATERIALS SCIENCE↗

Out-of-field Dose for Scanned and Scattered Proton Beams

The dose delivered outside of the primary field to non-target tissues is of concern in all types of radiotherapy. For a given radiation type, this dose is dependent upon the delivery technique. Proton beams may be spread laterally to cover the target volume using scattering foils or magnetic scanning. Although scattered beams always use apertures or multi-leaf collimators to limit the radiation to normal tissues, scanning beams may or may not use them. A direct comparison of out-of-field dose for different proton delivery techniques has been thwarted because no institution had, as of April 2008, used multiple delivery techniques and comparisons have had to make extrapolations from measurements or calculations made using different field sizes, ranges, modulations, collimator-to-skin distances, and collimator materials. In this study, the Monte Carlo program MCNPX was used to simulate the dose deposited outside of the primary field for scattered/collimated (STC), scanned/collimated (SNC), and scanned/uncollimated (SNU) beams that have the same field size and penetration depth within a simulated patient. The out-of-field doses ranged from 10{sup -2} to 10{sup -7} of the prescribed dose. The ratio of STC to SNU dose varied from 2 to 420 depending upon the depth and distance off-axis while the SNC to SNU dose varied from 1.2 to 140. As the out-of-field doses are very small for all beam delivery techniques, decisions regarding which technique is appropriate for a given patient or facility should be based upon the magnitude of the out-of-field dose per unit prescribed dose and other issues rather than the ratio of doses for the different beam delivery techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Image formation, resolution, and height measurement in scanning ion conductance microscopy

Scanning ion conductance microscopy (SICM) is an emerging tool for the noncontact investigation of biological samples such as live cells. It uses an ion current through the opening of a tapered nanopipette filled with an electrolyte for topography measurements. Despite its successful application to numerous systems no systematic investigation of the image formation process has yet been performed. Here, we use finite element modeling to investigate how the scanning ion conductance microscope images small particles on a planar surface, providing a fundamental characterization of the imaging process. We find that a small particle appears with a height that is only a fraction of its actual height. This has significant consequences for the quantitative interpretation of SICM images. Furthermore, small and low particles are imaged as rings in certain cases. This can cause small, closely spaced particles to appear with a lateral orientation that is rotated by 90 deg. Considering both real space and spatial frequency space we find that a reasonable and useful definition of lateral resolution of SICM is the smallest distance at which two small particles can clearly be resolved from each other in an image. We find that this resolution is approximately equal to three times the inner radius of the pipette tip opening.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OPTIMIZING A PORTABLE MICROWAVE INTERFERENCE SCANNING SYSTEM FOR NONDESTRUCTIVE TESTING OF MULTI-LAYERED DIELECTRIC MATERIALS

The projected microwave energy pattern, wave guide geometry, positioning methods and process variables have been optimized for use of a portable, non-contact, lap-top computer-controlled microwave interference scanning system on multi-layered dielectric materials. The system can be used in situ with one-sided access and has demonstrated capability of damage detection on composite ceramic armor. Specimens used for validation included specially fabricated surrogates, and ballistic impact-damaged specimens. Microwave data results were corroborated with high resolution direct-digital x-ray imaging. Microwave interference scanning detects cracks, laminar features and material properties variations. This paper presents the details of the system, the optimization steps and discusses results obtained.

36 MATERIALS SCIENCE↗

LINEAR SCANNING METHOD BASED ON THE SAFT COARRAY

This work presents a method to obtain B-scan images based on linear array scanning and 2R-SAFT. Using this technique some advantages are obtained: the ultrasonic system is very simple; it avoids the grating lobes formation, characteristic in conventional SAFT; and subaperture size and focussing lens (to compensate emission-reception) can be adapted dynamically to every image point. The proposed method has been experimentally tested in the inspection of CFRP samples.

36 MATERIALS SCIENCE↗

Experimental verification of tomographic phase-space imaging for beams with space-charge using a pinhole-scan

A model is described for tomographic phase-space mapping and emittance measurement in beams with space-charge. The tomographic results of an experiment with a 10 keV space-charge dominated electron beam are presented. The data are compared against a direct experimental sampling of the phase-space using a pinhole scan. It is found that the accuracy of the tomographic method is within 10% for beams with space-charge intensity less than 90%. With the aid of numerical simulation the observed similarities and differences between the tomography method and pinhole scan are discussed.

43 PARTICLE ACCELERATORS↗

Synchronized monochromator and insertion device energy scans at SLS

Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

43 PARTICLE ACCELERATORS↗

A spinning mirror for fast angular scans of EBW emission for magnetic pitch profile measurements

A tilted spinning mirror rapidly steers the line of sight of the electron Bernstein wave (EBW) emission radiometer at the Mega-Amp Spherical Tokamak (MAST). In order to resist high mechanical stresses at rotation speeds of up to 12 000 rpm and to avoid eddy current induced magnetic braking, the mirror consists of a glass-reinforced nylon substrate of a special self-balanced design, coated with a reflecting layer. By completing an angular scan every 2.5-10 ms, it allows one to characterize with good time resolution the Bernstein-extraordinary-ordinary mode-conversion efficiency as a function of the view angles. Angular maps of conversion efficiency are directly related to the magnetic pitch angle at the cutoff layer for the ordinary mode. Hence, measurements at various frequencies provide the safety factor profile at the plasma edge. Initial measurements and indications of the feasibility of the diagnostic are presented. Moreover, angular scans indicate the best launch conditions for EBW heating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pencil Beam Scanning System Based On A Cyclotron

Sumitomo Heavy Industries, Ltd. (SHI) has developed a new pencil beam scanning system (PBS) for proton therapy in collaboration with National Cancer Center Hospital East (NCCHE). Taking advantage of the continuous beam from the cyclotron P235, the line scanning method is employed in order to realize continuous irradiation with high dose rate. 3D uniform and sphere field was irradiated and compared with the simulation.

43 PARTICLE ACCELERATORS↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniaturized hand held microwave interference scanning system for NDE of dielectric armor and armor systems

Inspection of ceramic-based armor has advanced through development of a microwave-based, portable, non-contact NDE system. Recently, this system was miniaturized and made wireless for maximum utility in field applications. The electronic components and functionality of the laboratory system are retained, with alternative means of position input for creation of scan images. Validation of the detection capability was recently demonstrated using specially fabricated surrogates and ballistic impact-damaged specimens. The microwave data results have been compared to data from laboratory-based microwave interferometry systems and digital x-ray imaging. The microwave interference scanning has been shown to reliably detect cracks, laminar features and material property variations. The authors present details of the system operation, descriptions of the test samples used and recent results obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scanning capacitance microscopy of ErAs nanoparticles embedded in GaAs pn junctions

Scanning capacitance microscopy is used to characterize the electronic properties of ErAs nanoparticles embedded in GaAs pn junctions grown by molecular beam epitaxy. Voltage-dependent capacitance images reveal localized variations in subsurface electronic structure near buried ErAs nanoparticles at lateral length scales of 20-30 nm. Numerical modeling indicates that these variations arise from inhomogeneities in charge modulation due to Fermi level pinning behavior associated with the embedded ErAs nanoparticles. Statistical analysis of image data yields an average particle radius of 6-8 nm--well below the direct resolution limit in scanning capacitance microscopy but discernible via analysis of patterns in nanoscale capacitance images.

36 MATERIALS SCIENCE↗

Quick-scanning x-ray absorption spectroscopy system with a servo-motor-driven channel-cut monochromator with a temporal resolution of 10 ms

We have developed a quick-scanning x-ray absorption fine structure (QXAFS) system and installed it at the recently constructed synchrotron radiation beamline BL33XU at the SPring-8. Rapid acquisition of high-quality QXAFS data was realized by combining a servo-motor-driven Si channel-cut monochromator with a tapered undulator. Two tandemly aligned monochromators with channel-cut Si(111) and Si(220) crystals covered energy ranges of 4.0-28.2 keV and 6.6-46.0 keV, respectively. The system allows the users to adjust instantly the energy ranges of scans, the starting angles of oscillations, and the frequencies. The channel-cut crystals are cooled with liquid nitrogen to enable them to withstand the high heat load from the undulator radiation. Deformation of the reflecting planes is reduced by clamping each crystal with two cooling blocks. Performance tests at the Cu K-edge demonstrated sufficiently high data quality for x-ray absorption near-edge structure and extended x-ray absorption fine-structure analyses with temporal resolutions of up to 10 and 25 ms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Luminescence-based magnetic imaging with scanning x-ray transmission microscopy

We demonstrate the imaging of the magnetic domain configuration of cobalt structures fabricated on MgO(001) using x-ray induced optical luminescence in a scanning transmission microscope. The technique relies on the measurement of the magnetization-dependent x-ray absorption probed by the optical luminescence radiated from the MgO substrate and induced by the x-rays transmitted through the magnetic layer. This method enables the measurement of the electronic and magnetic spectroscopic properties of single crystalline layers and buried heterostructures with nanometer lateral resolution and elemental sensitivity and opens scanning transmission x-ray microscopy to materials which cannot be grown on membranes or as freestanding thin films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new adaptive light beam focusing principle for scanning light stimulation systems

In this article a novel principle to achieve optimal focusing conditions or rather the smallest possible beam diameter for scanning light stimulation systems is presented. It is based on the following methodology: First, a reference point on a camera sensor is introduced where optimal focusing conditions are adjusted and the distance between the light focusing optic and the reference point is determined using a laser displacement sensor. In a second step, this displacement sensor is used to map the topography of the sample under investigation. Finally, the actual measurement is conducted, using optimal focusing conditions in each measurement point at the sample surface, that are determined by the height difference between camera sensor and the sample topography. This principle is independent of the measurement values, the optical or electrical properties of the sample, the used light source, or the selected wavelength. Furthermore, the samples can be tilted, rough, bent, or of different surface materials. In the following the principle is implemented using an optical beam induced current system, but basically it can be applied to any other scanning light stimulation system. Measurements to demonstrate its operation are shown, using a polycrystalline silicon solar cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗