Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Two-stage formation-energy correction (NbZr, TaZr, VZr)

This bundle contains the scripts, the raw and corrected per-structure data, and the manuscript plots for the NbZr / TaZr / VZr BCC binary formation energies and the associated RMSDs. Why a two-stage correction is necessary: The "raw" formation energy of every relaxed VASP configuration is computed in the usual way, FE_raw(c) = E_alloy(c) - sum_i x_i * E_pure_i , where E_pure_i are the per-atom total energies of the pure-element reference structures (Nb, Ta, V, Zr in the same BCC supercell, with identical INCAR / KPOINTS / PAW choices). With perfectly consistent reference runs the raw FE should vanish at the two pure-element endpoints (x = 0 and x = 1) by construction. In practice this does not hold for two reasons that are present in our dataset: 1. Reference-energy inconsistency (composition-dependent bias). Even with identical input parameters, the pure-element runs (stored in `corrected_DFT_pure_element_runs/`) differ slightly from the values that would be implied by the alloy runs at near-pure compositions (a few meV/atom). This bias is approximately linear in concentration, because the residual error in E_pure_Nb (or E_pure_Ta / E_pure_V) propagates into FE_raw(c) as (1 - x) * dE_pure_1, and the corresponding error in E_pure_Zr propagates as x * dE_pure_2. Left uncorrected, this produces a non-physical "tilt" of FE_raw(x) and shifts the entire FE-vs-x cloud away from zero at the endpoints. 2. Endpoint anchoring against the audited true endpoints. The strict endpoint values (FE_x0_meVatom, FE_x1_meVatom in `corrected_fe_strict_endpoints_20260518/strict_endpoint_check_20260518.csv`) were re-derived from an independent cross-check of the pure-element runs. After stage 1 removes the linear bias, the near-pure compositions in the alloy dataset still extrapolate to values that differ slightly from these audited endpoints — because stage 1 is fit from a few near-end alloy bins, not from the audited pure-element references themselves. The README.txt file discusses how these issues are addressed by the two-stage correction, and describes folder layout, pipeline summary, and how to re-run.

36 MATERIALS SCIENCE↗

Reformulation of Density Functional Theory for N-Representable Densities and the Resolution of the v-Representability Problem

Density functional theory for the case of general, N-representable densities is reformulated in terms of density functional derivatives of expectation values of operators evaluated with wave functions leading to a density, making no reference to the concept of potential. The developments provide a complete solution of the v-representability problem by establishing a mathematical procedure that determines whether a density is v-representable and in the case of an affirmative answer determines the potential (within an additive constant) as a derivative with respect to the density of a constrained search functional. It also establishes the existence of an energy functional of the density that, for v-representable densities, assumes its minimum value at the density describing the ground state of an interacting many-particle system. The theorems of Hohenberg and Kohn emerge as special cases of the formalism.

36 MATERIALS SCIENCE↗

Hot, cold, and annual reference atmospheres for Edwards Air Force Base, California (1975 version)

Reference atmospheres pertaining to summer (hot), winter (cold), and mean annual conditions for Edwards Air Force Base, California, are presented from surface to 90 km altitude (700 km for the annual model). Computed values of pressure, kinetic temperature, virtual temperature, and density and relative differences percentage departure from the Edwards reference atmospheres, 1975 (ERA-75) of the atmospheric parameters versus altitude are tabulated in 250 m increments. Hydrostatic and gas law equations were used in conjunction with radiosonde and rocketsonde thermodynamic data in determining the vertical structure of these atmospheric models. The thermodynamic parameters were all subjected to a fifth degree least-squares curve-fit procedure, and the resulting coefficients were incorporated into Univac 1108 computer subroutines so that any quantity may be recomputed at any desired altitude using these subroutines.

Johnson, D. L.↗

Efficient optimal minimum error discrimination of symmetric quantum states

This article deals with the quantum optimal discrimination among mixed quantum states enjoying geometrical uniform symmetry with respect to a reference density operator rho{sub 0}. It is well known that the minimal error probability is given by the positive operator-valued measure obtained as a solution of a convex optimization problem, namely a set of operators satisfying geometrical symmetry, with respect to a reference operator PI{sub 0} and maximizing Tr(rho{sub 0}PI{sub 0}). In this article, by resolving the dual problem, we show that the same result is obtained by minimizing the trace of a semidefinite positive operator X commuting with the symmetry operator and such that X>=rho{sub 0}. The new formulation gives a deeper insight into the optimization problem and allows to obtain closed-form analytical solutions, as shown by a simple but not trivial explanatory example. In addition to the theoretical interest, the result leads to semidefinite programming solutions of reduced complexity, allowing to extend the numerical performance evaluation to quantum communication systems modeled in Hilbert spaces of large dimension.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Group Additivity Determination for Oxygenates, Oxonium Ions, and Oxygen-Containing Carbenium Ions

Bio-oil produced from biomass fast pyrolysis often requires catalytic upgrading to remove oxygen and acidic species over zeolite catalysts. The elementary reactions in the mechanism for this process involve carbenium and oxonium ions. In order to develop a detailed kinetic model for the catalytic upgrading of biomass, rate constants are required for these elementary reactions. The parameters in the Arrhenius equation can be related to thermodynamic properties through structure-reactivity relationships, such as the Evans-Polanyi relationship. For this relationship, enthalpies of formation of each species are required, which can be reasonably estimated using group additivity. However, the literature previously lacked group additivity values for oxygenates, oxonium ions, and oxygen-containing carbenium ions. In this work, 71 group additivity values for these types of groups were regressed, 65 of which had not been reported previously and six of which were newly estimated based on regression in the context of the 65 new groups. Heats of formation based on atomization enthalpy calculations for a set of reference molecules and isodesmic reactions for a small set of larger species for which experimental data was available were used to demonstrate the accuracy of the Gaussian-4 quantum mechanical method in estimating enthalpies of formation for species involving the moieties of interest. Isodesmic reactions for a total of 195 species were constructed from the reference molecules to calculate enthalpies of formation that were used to regress the group additivity values. The results showed an average deviation of 1.95 kcal/mol between the values calculated from Gaussian-4 and isodesmic reactions versus those calculated from the group additivity values that were newly regressed. Importantly, the new groups enhance the database for group additivity values, especially those involving oxonium ions.

09 BIOMASS FUELS↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

Stable Adaptive Inertial Control of a Doubly-Fed Induction Generator

This paper proposes a stable adaptive inertial control scheme of a doubly-fed induction generator. The proposed power reference is defined in two sections: the deceleration period and the acceleration period. The power reference in the deceleration period consists of a constant and the reference for maximum power point tracking (MPPT) operation. The latter contributes to preventing a second frequency dip (SFD) in this period because its reduction rate is large at the early stage of an event but quickly decreases with time. To improve the frequency nadir (FN), the constant value is set to be proportional to the rotor speed prior to an event. The reference ensures that the rotor speed converges to a stable operating region. To accelerate the rotor speed while causing a small SFD, when the rotor speed converges, the power reference is reduced by a small amount and maintained until it meets the MPPT reference. The results show that the scheme causes a small SFD while improving the FN and the rate of change of frequency in any wind conditions, even in a grid that has a high penetration of wind power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Global Reference Atmospheric Model (GRAM) Suite Overview and Current Status

• Engineering-oriented atmospheric models that estimate mean values and statistical variations of atmospheric properties for numerous planetary destinations • Currently available for Earth, Mars, Venus, Titan, Neptune, Uranus, and Jupiter • Outputs include atmospheric density, temperature, pressure, chemical composition, radiative fluxes (for Mars-GRAM), and wind components along a user-defined path – Includes seasonal, diurnal, geographic, and altitude variations • Widely used by the engineering community because of their ability to create realistic atmospheric dispersions • Can be integrated into high fidelity flight dynamic simulations of launch, entry, descent and landing (EDL), aerobraking and aerocapture • Optional trajectory input file consisting of time, height, latitude, and longitude can be used to provide the GRAM trajectory path • Optional auxiliary profile consisting of height, latitude, longitude, temperature, pressure, density, eastward wind, and northward wind may be used to replace model data in the GRAMs • Not a forecast model

atmospheric models↗

SU-G-206-08: How Should Focal Spot Be Chosen for Optimized CT Imaging with Dose Modulation?

Purpose: To choose the preferred focal spot for achieving optimized CT image quality with balanced tube heating considerations. Methods: An anthropomorphic pelvic phantom was scanned using a GE Discovery CT750 HD at 120 and 140kVp, 0.8s rotation time, and pitch of 0.984. “Smart mA” was enabled to simulate a routine abdomen–pelvis CT scan. Permissible mA values at 120 and 140 kVp were obtained from the Serial Load Rating table (for mimicking a busy CT clinical operation) in the scanner Technical Reference Manual. At each kVp station and two Noise Index levels, the mA Upper Limit was set above/below the permissible mA values. Scanned mA values and focal spot (FS) used were obtained from the DICOM header of each image, and the FS-mA relationship was analyzed. For visual confirmation beyond recorded FS information, a CatPhan with a fat-ring attached for mimicking patient size/shape was scanned at 120kVp. A group of radiologists/physicists compared a pair of CatPhan images qualitatively. Lastly, a number of patient cases were evaluated to confirm the FS-mA relationship. Results: When preset Upper Limit values were above the permissible mA values, the Large FS (labeled 1.2) was used in scans, even if the maximum scanned mA values were much lower than the permissible values at both 120 and 140 kVp. Otherwise the Small FS (labeled 0.7) was used. Visual evaluation of the high contrast module of CatPhan and additional analysis of patient cases further confirmed that the preset Upper Limit determines which focal spot is to be used, not the actual maximum mA value to be scanned. Conclusion: Specific FS can be selected by setting up appropriate mA Upper Limit in a protocol. CT protocols could be optimized by selecting appropriate FS for improving patient image quality, especially benefiting the small size and pediatric patients.

60 APPLIED LIFE SCIENCES↗

A High Precision Measurement of the Proton Charge Radius at JLab

The elastic electron-proton (e-p) scattering and the spectroscopy of hydrogen atoms are the two traditional methods to determine the proton charge radius (r p ). In 2010, a new method using muonic hydrogen (µH) 1 spectroscopy reported a r p result that was nearly ten times more precise but significantly smaller than the values from the compilation of all previous r p measurements. This discrepancy is often referred to as the "proton charge radius puzzle". In order to investigate the puzzle, the PRad experiment (E12-11-106) was first proposed in 2011 and performed in 2016 in Hall B at the Thomas Jefferson National Accelerator Facility, with both 1.1 and 2.2 GeV electron beams. The experiment measured the e-p elastic scattering cross sections in an unprecedented low values of momentum transfer squared region (Q 2 = 2.1× 10 -4 -0.06 (GeV/c) 2 ), with a sub-percent precision. The PRad experiment utilized a calorimetric method that was magnetic-spectrometer-free. Its detector setup included a large acceptance and high resolution calorimeter (HyCal), and two large-area, high spatial-resolution Gas Electron Multiplier (GEM) detectors. To have a better control over the systematic uncertainties, the absolute e-p elastic scattering cross section was normalized to that of the well-known Møller scattering process, which was measured simultaneously during the experiment. For each beam energy, all data with different Q 2 were collected simultaneously with the same detector setup, therefore sharing the same integrated luminosity. The windowless H 2 gas-flow target utilized in the experiment largely removed a typical background source, the target cell windows. The proton charge radius was determined as r p = 0.831±0.007 stat. ±0.012 p fm, which is smaller than the average r p from previous e-p elastic scattering experiments, but in agreement with the µH spectroscopic results within the experimental uncertainties.

Source record↗

Compositional variability of the Martian surface

Spectral reflectance data from Viking Landers and Orbiters and from telescopic observations were analyzed with the objective of isolating compositional information about the Martian surface and assessing compositional variability. Two approaches were used to calibrate the data to reflectance to permit direct comparisons with laboratory reference spectra of well characterized materials. In Viking Lander multispectral images (six spectral bands) most of the spectral variation is caused by changes in lighting geometry within individual scenes, from scene to scene, and over time. Lighting variations are both wavelength independent and wavelength dependent. By calibrating lander image radiance values to reflectance using spectral mixture analysis, the possible range of compositions was assessed with reference to a collection of laboratory samples, also resampled to the lander spectral bands. All spectra from the lander images studied plot (in six-space) within a planar triangle having at the apexes the respective spectra of tan basaltic palagonite, gray basalt, and shale. Within this plane all lander spectra fit as mixtures of these three endmembers. Reference spectra that plot outside of the triangle are unable to account for the spectral variation observed in the images.

Adams, John B.↗

Is There an Additional Value of {sup 11}C-Choline PET-CT to T2-weighted MRI Images in the Localization of Intraprostatic Tumor Nodules?

Purpose: To investigate the additional value of {sup 11}C-choline positron emission tomography (PET)-computed tomography (CT) to T2-weighted (T2w) magnetic resonance imaging (MRI) for localization of intraprostatic tumor nodules. Methods and Materials: Forty-nine prostate cancer patients underwent T2w MRI and {sup 11}C-choline PET-CT before radical prostatectomy and extended lymphadenectomy. Tumor regions were outlined on the whole-mount histopathology sections and on the T2w MR images. Tumor localization was recorded in the basal, middle, and apical part of the prostate by means of an octant grid. To analyze {sup 11}C-choline PET-CT images, the same grid was used to calculate the standardized uptake values (SUV) per octant, after rigid registration with the T2w MR images for anatomic reference. Results: In total, 1,176 octants were analyzed. Sensitivity, specificity, and accuracy of T2w MRI were 33.5%, 94.6%, and 70.2%, respectively. For {sup 11}C-choline PET-CT, the mean SUV{sub max} of malignant octants was significantly higher than the mean SUV{sub max} of benign octants (3.69 {+-} 1.29 vs. 3.06 {+-} 0.97, p < 0.0001) which was also true for mean SUV{sub mean} values (2.39 {+-} 0.77 vs. 1.94 {+-} 0.61, p < 0.0001). A positive correlation was observed between SUV{sub mean} and absolute tumor volume (Spearman r = 0.3003, p = 0.0362). No correlation was found between SUVs and prostate-specific antigen, T-stage or Gleason score. The highest accuracy (61.1%) was obtained with a SUV{sub max} cutoff of 2.70, resulting in a sensitivity of 77.4% and a specificity of 44.9%. When both modalities were combined (PET-CT or MRI positive), sensitivity levels increased as a function of SUV{sub max} but at the cost of specificity. When only considering suspect octants on {sup 11}C-choline PET-CT (SUV{sub max} {>=} 2.70) and T2w MRI, 84.7% of these segments were in agreement with the gold standard, compared with 80.5% for T2w MRI alone. Conclusions: The additional value of {sup 11}C-choline PET-CT next to T2w MRI in detecting tumor nodules within the prostate is limited.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-CAMPUS-I-05: Internal Dosimetric Calculations for Several Imaging Radiopharmaceuticals in Preclinical Studies and Quantitative Assessment of the Mouse Size Impact On Them. Realistic Monte Carlo Simulations Based On the 4D-MOBY Model

Purpose: Commonly used radiopharmaceuticals were tested to define the most important dosimetric factors in preclinical studies. Dosimetric calculations were applied in two different whole-body mouse models, with varying organ size, so as to determine their impact on absorbed doses and S-values. Organ mass influence was evaluated with computational models and Monte Carlo(MC) simulations. Methods: MC simulations were executed on GATE to determine dose distribution in the 4D digital MOBY mouse phantom. Two mouse models, 28 and 34 g respectively, were constructed based on realistic preclinical exams to calculate the absorbed doses and S-values of five commonly used radionuclides in SPECT/PET studies (18F, 68Ga, 177Lu, 111In and 99mTc).Radionuclide biodistributions were obtained from literature. Realistic statistics (uncertainty lower than 4.5%) were acquired using the standard physical model in Geant4. Comparisons of the dosimetric calculations on the two different phantoms for each radiopharmaceutical are presented. Results: Dose per organ in mGy was calculated for all radiopharmaceuticals. The two models introduced a difference of 0.69% in their brain masses, while the largest differences were observed in the marrow 18.98% and in the thyroid 18.65% masses.Furthermore, S-values of the most important target-organs were calculated for each isotope. Source-organ was selected to be the whole mouse body.Differences on the S-factors were observed in the 6.0–30.0% range. Tables with all the calculations as reference dosimetric data were developed. Conclusion: Accurate dose per organ and the most appropriate S-values are derived for specific preclinical studies. The impact of the mouse model size is rather high (up to 30% for a 17.65% difference in the total mass), and thus accurate definition of the organ mass is a crucial parameter for self-absorbed S values calculation.Our goal is to extent the study for accurate estimations in small animal imaging, whereas it is known that there is a large variety in the anatomy of the organs.

60 APPLIED LIFE SCIENCES↗

The use of stellite scatterometer winds to drive a primitive equation model of the Indian Ocean: The impact of bandlike sampling

The aim of this study is to evaluate the impact of the bandlike sampling of spaceborne scatterometers on the ability of scatterometer winds to successfully force the mean flow and seasonal cycle of an ocean model in the context of equatorial and tropical dynamics. The equatorial ocean is simulated with a four-layer, primitive equation, reduced gravity model of the Indian Ocean. The variable wind stress used in this study is derived from one year (1988) of 6-hour analyses of the 10-m wind vector over the Indian Ocean performed at the European Centre for Medium-Range Weather Forecasts (ECMWF). It is applied as a forcing at every grid point of the model to drive a reference circulation. Scatterometer winds are simulated from ECMWF winds, using the nominal configurations and orbital parameters of the European Remote Sensing 1 (ERS-1) and NASA Scatterometer (NSCAT) missions. The model is forced in real time under swaths with the raw scatterometer winds of ERS-1 and NSCAT, with a persistence condition (i.e., the wind is kept constsnt until the next passage of the satellite provides a new value). The circulation obtained for each of the scatterometer experiments is compared with the reference circulation. The seasonal circulation of the Indian Ocean with NSCAT winds is very similar to the reference. The perturbations introduced by the bandlike sampling and the persistance condition have an impact similar to that of a small uncorrelated noise added to the reference forcing. The persistence condition for ERS-1 does not give results which are as good as those obtained for NSCAT.

Barnier, Bernard↗

Extension of frozen natural orbital approximation to open-shell references: Theory, implementation, and application to single-molecule magnets

Natural orbitals are often used to achieve a more compact representation of correlated wave-functions. Using natural orbitals computed as eigenstates of the virtual–virtual block of the state density matrix instead of the canonical Hartree–Fock orbitals results in smaller errors when the same fraction of virtual space is frozen. This strategy, termed frozen natural orbital (FNO) approach, is effective in reducing the cost of regular coupled-cluster (CC) calculations and some multistate methods, such as EOM-IP-CC (equation-of-motion CC for ionization potentials). This contribution extends the FNO approach to the EOM-SF-CC ansatz (EOM-CC with spin-flip). In contrast to EOM-IP-CCSD, EOM-SF-CCSD relies on high-spin open-shell references. Using FNOs computed for an open-shell reference leads to an erratic behavior of the EOM-SF-CC energies and properties due to an inconsistent truncation of the α and β orbital spaces. A general solution to problems arising in the EOM-CC calculations utilizing open-shell references, termed OSFNO (open-shell FNO), is proposed. Furthermore, by means of singular value decomposition (SVD) of the overlap matrix of the α and β orbitals, the OSFNO algorithm identifies the corresponding orbitals and determines virtual orbitals corresponding to the singly occupied space. This is followed by SVD of the singlet part of the state density matrix in the remaining virtual orbital subspace. The so-computed FNOs preserve the spin purity of the open-shell orbital subspace to the extent allowed by the original reference, thus facilitating a safe truncation of the virtual space. The performance of OSFNO is benchmarked for selected diradicals and triradicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Generic repository design concepts and thermal analysis (FY11).

Reference concepts for geologic disposal of used nuclear fuel and high-level radioactive waste in the U.S. are developed, including geologic settings and engineered barriers. Repository thermal analysis is demonstrated for a range of waste types from projected future, advanced nuclear fuel cycles. The results show significant differences among geologic media considered (clay/shale, crystalline rock, salt), and also that waste package size and waste loading must be limited to meet targeted maximum temperature values. In this study, the UFD R&D Campaign has developed a set of reference geologic disposal concepts for a range of waste types that could potentially be generated in advanced nuclear FCs. A disposal concept consists of three components: waste inventory, geologic setting, and concept of operations. Mature repository concepts have been developed in other countries for disposal of spent LWR fuel and HLW from reprocessing UNF, and these serve as starting points for developing this set. Additional design details and EBS concepts will be considered as the reference disposal concepts evolve. The waste inventory considered in this study includes: (1) direct disposal of SNF from the LWR fleet, including Gen III+ advanced LWRs being developed through the Nuclear Power 2010 Program, operating in a once-through cycle; (2) waste generated from reprocessing of LWR UOX UNF to recover U and Pu, and subsequent direct disposal of used Pu-MOX fuel (also used in LWRs) in a modified-open cycle; and (3) waste generated by continuous recycling of metal fuel from fast reactors operating in a TRU burner configuration, with additional TRU material input supplied from reprocessing of LWR UOX fuel. The geologic setting provides the natural barriers, and establishes the boundary conditions for performance of engineered barriers. The composition and physical properties of the host medium dictate design and construction approaches, and determine hydrologic and thermal responses of the disposal system. Clay/shale, salt, and crystalline rock media are selected as the basis for reference mined geologic disposal concepts in this study, consistent with advanced international repository programs, and previous investigations in the U.S. The U.S. pursued deep geologic disposal programs in crystalline rock, shale, salt, and volcanic rock in the years leading up to the Nuclear Waste Policy Act, or NWPA (Rechard et al. 2011). The 1987 NWPA amendment act focused the U.S. program on unsaturated, volcanic rock at the Yucca Mountain site, culminating in the 2008 license application. Additional work on unsaturated, crystalline rock settings (e.g., volcanic tuff) is not required to support this generic study. Reference disposal concepts are selected for the media listed above and for deep borehole disposal, drawing from recent work in the U.S. and internationally. The main features of the repository concepts are discussed in Section 4.5 and summarized in Table ES-1. Temperature histories at the waste package surface and a specified distance into the host rock are calculated for combinations of waste types and reference disposal concepts, specifying waste package emplacement modes. Target maximum waste package surface temperatures are identified, enabling a sensitivity study to inform the tradeoff between the quantity of waste per disposal package, and decay storage duration, with respect to peak temperature at the waste package surface. For surface storage duration on the order of 100 years or less, waste package sizes for direct disposal of SNF are effectively limited to 4-PWR configurations (or equivalent size and output). Thermal results are summarized, along with recommendations for follow-on work including adding additional reference concepts, verification and uncertainty analysis for thermal calculations, developing descriptions of surface facilities and other system details, and cost estimation to support system-level evaluations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PV Reference Cells for Outdoor Use: An Investigation of Calibration Factors

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as a low-cost alternative to thermopile radiometers. But reference cell characteristics differ substantially from the latter, therefore measurements made by one category of instrument cannot be substituted for or directly compared with the other. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of 39 units of 10 distinct types made by 6 manufacturers. This report compares the calibration factors provided by manufacturers - which most users rely upon - to those measured at a high level of accuracy by NREL's Cell Lab. It also reports on the application of the Broadband Outdoor Radiometer Calibration (BORCAL) method to reference cells. As a group, the factory calibrations for the crystalline silicon cells showed a small positive bias of +0.7%, with a tight distribution around this value. This is a very good result for the manufacturers. The two World Photovoltaic Scale cells constituted outliers, with a mean deviation of -0.8%, which is still within the reported uncertainty ranges. The data collected during the BORCAL procedures show a strong and systematic fluctuation of the apparent responsivity of the reference cells over the course of a day, which was anticipated. Consequently, the standard BORCAL R@45 calibration factors underestimated the reference cell responsivities by 1%-4%. An alternate responsivity indicator was developed, R'@30, incorporating adjustments for temperature response, spectral response, and directional response. This reduced the mean deviation to -0.4% compared to the Cell Lab. Further, two independent BORCAL sessions were able to produce the same values to within ±0.2%. This could be a viable approach for verifying reference cells using existing BORCAL infrastructure, for example, to evaluate their long-term stability. The daily profiles of responsivity obtained during the BORCAL sessions (provided in Appendix A) show clear patterns of differences between models, which provides evidence that their directional responses differ from each other; thus, two sensors that are calibrated correctly might give the same reading at 30° zenith angle but systematically different readings at 60°. The impact of these inconsistencies in field operation will be quantified using the long-term observations started in 2020.

14 SOLAR ENERGY↗