Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Exposure Assumptions Underlying Cleanups to Industrial Versus Unrestricted Uses: Comparison of State and Federal Approaches - 17228

The Environmental Protection Agency (EPA) and various states have designated a variety of cleanup levels ranging from restricted (too much residual contamination to allow any use) to unrestricted or residential. Although there are many potential exposure scenarios, the States of Washington and New Jersey identify only two levels for cleanup of chemical contaminants in soil: 'unrestricted' and 'industrial' (Washington) and 'residential' vs 'non-residential' (New Jersey). Other agencies such as EPA and DOE recognize several levels of recreational use, between unrestricted and industrial, and likewise there are several levels of residential use as well. Cleanup criteria may allow or preclude the use of ground water for drinking, swimming pools, gardens, or lawns. Tribal unrestricted scenarios include the use of water (probably surface water in most scenarios) for sweat lodges, and have calculated high level exposure pathways for both dermal and inhalation pathways as well as ingestion. For residential scenarios, inadvertent ingestion of soil, drinking of ground water, and consumption of local foods represent the highest exposure pathways. Intermediate, recreational pathways may be non-consumptive (hiking, bird watching, photography) or consumptive (hunting, fishing, harvesting plants and medicines), the latter entailing much higher potential exposures. For each land-use there is a corresponding exposure scenario, with different assumptions about the maximally exposed individual, their age, and the amounts of air, water, soil, and foods they consume. For each exposure pathway one can compute the ratio between the exposure assumptions for any two scenarios. The product of the ratios comprises a Vulnerability Index. The index is higher for children than adults. For Washington this Index is reflected in the 'industrial' vs 'unrestricted' soil cleanup levels, which are 43.7 times lower for 'unrestricted'. This paper explores the similarities and differences in the exposure scenarios and vulnerability of the maximally exposed individuals and the consequences of a mismatch between current cleanup levels and possible future land uses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cost Effectiveness of Home Energy Retrofits in Pre-Code Vintage Homes in the United States

This analytical study examines the opportunities for cost-effective energy efficiency and renewable energy retrofits in residential archetypes constructed prior to 1980 (Pre-Code) in fourteen U.S. cities. These fourteen cities are representative of each of the International Energy Conservation Code (IECC) climate zones in the contiguous United States. The analysis is conducted using an in-house version of EnergyGauge USA v.2.8.05 named CostOpt that has been programmed to perform iterative, incremental economic optimization on a large list of residential energy efficiency and renewable energy retrofit measures. The principle objectives of the study are to determine the opportunities for cost effective source energy reductions in this large cohort of existing residential building stock as a function of local climate and energy costs; and to examine how retrofit financing alternatives impact the source energy reductions that are cost effectively achievable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Policymaker's Guide to Scaling Home Energy Upgrades

There has never been a better time to launch initiatives to promote residential energy efficiency savings. Over the past several decades, residential retrofit programs have demonstrated that energy efficiency measures contribute to achieving multiple benefits, including but not limited to reductions in home energy consumption, stabilization improvements for the grid by shaving peak loads, saving consumers millions on utility bills, and significantly reducing carbon emissions. Although a number of barriers to widespread uptake of home energy upgrades persist, the lessons learned as a result of the 2009 stimulus funding1 have resulted in a set of policy approaches that create new strategies for taking residential energy efficiency to scale.2 The identification of these approaches is well timed; energy efficiency is often the least expensive and most cost effective way to comply with a variety of federal, state and local policies. This Guide is designed to help state and local policymakers to take full advantage of new policy developments by providing them with a comprehensive set of tools to support launching or accelerating residential energy efficiency programs. It is written primarily for state and local policymakers, including state and local executives, legislators, public utility commissioners, and the staff who advise them.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Efficient Clothes Dryer with IR Heating and Electrostatic Precipitator

The project goal was to develop a revolutionary energy saving technology for residential clothes drying. The team developed an IR (infrared) heating system and NESP (Nebulizer and Electro-Static Precipitator) for integration into a ventless clothes dryer. The proposed technology addresses two of the major inefficiencies in current electric vented dryers by providing effective energy transfer for the removal of the water and recapture of the vapor latent heat. The IR heaters operating in the mid wave (2.5-10um) are very efficient as they target the 3-micron peak absorption of the water molecule. This allows direct energy absorption, unlike conventional element heaters where heat is transferred by convection. The low power NESP removes water vapor from the exhausted stream and recaptures the latent heat in the ESP (Electro-Static Precipitator) exchanger section. This allows the warm dry air to be recirculated back into the drum for additional efficiency savings. The remaining majority of the dryer hardware stays the same. Summing the efficiency gain from the two subcomponents we anticipated the EF (Efficiency Factor) to exceed the goal of 4.04. EF is obtained by dividing the weight (lbs) of water removed by the energy (kWhr) used, where the test load size is 8.45 lbs of bone dry clothing wetted to 57.5% or 4.8lbs of water, and dried to a remaining moisture content of 2.5-5%. Additional benefits include not having to recondition (heat or cool) the large amounts of make-up air to replace the air exhausted by a vented dryer. It was anticipated that the NESP/heat exchanger would be the most challenging and highest risk element in the program. Therefore, the team focused their efforts during Phase 1 of the program on the design, construction, testing, and optimization of the NESP/heat exchanger. At the end Phase 1, the team compared the performance of the NESP/heat exchanger with the system level requirements and made a Go/No-Go decision on proceeding with the second portion of the program. Phase 2 of the program was structured to develop the IR heating system and then integrate it and the NESP/heat exchanger into a residential clothes dryer prototype for final testing. The proposed technology utilizes heat recovery which is known to have the biggest impact on dryer efficiency. The two current mainstream recovery approaches are air to air exchangers and heat pump condenser systems. Air to air exchanges can be very efficient but require large surface areas which are prone to fouling from uncaptured lint. Dryers based on heat pump condenser recovery systems have shown efficiency improvements of 20–60% and are commercially available. The issue with a heat pump condenser approach is the added cost, as typical prices are twice that of standard vented dryers and they are only available in small to medium capacities. The energy factor (EF) for these systems is 5.50 to 6.88 pounds/kWh compared to conventional dryers at 2.75 to 3.67 pounds/kWh. The efficiency improvements for the proposed technology come from the use of IR heating and the NESP. As the concept is in its infancy, and these improvements were difficult to predict without experimental data, assumptions were made based on available literature. IR radiant drying times, when compared to convection, are typically 30% less. This is a result of the fact that radiant energy heats directly and is absorbed at and below the surface, unlike convection heating, that must conduct the heat through the boundary film of air at the clothes surface and rely on wicking of the moisture to the surface. The second area of improvement comes from the NESP. The NESP operation is as follows: 1. Highly charged, micron sized, droplets of water are injected into the dryer exhaust by the Nebulizer. 2. These charged droplets attract water molecules and continue to grow in size, until losing their charge. During this process, latent heat is rejected back into the air stream. 3. The large droplets enter the ESP, where they are recharged and drawn to the ESP wall, to be extracted at the bottom of the ESP. The warm dry air is then recirculated back into the dryer. The proposed technology, at the time of the proposal submission was estimated to have an EF of 4.79. At program completion we have designed, built, tested, integrated and optimized the proposed technologies into a prototype “high efficiency” residential clothes dryer. Testing of the integrated prototype dryer provided insight into the technical effectiveness and economic feasibility of the proposed technologies. The program has the potential of greatly impacting energy savings. The predicted EF of the proposed technology is 4.79, yielding an energy savings of 42% when compared to conventional electric vented dryers. Given there are approximately 84 million dryers in the US consuming ~64 billion kWh per year, a net savings of 27 billion kWh per year or 0.092 quads could be realized. Since the dryer is not vented, make up air from the room is not needed, adding an additional savings of ~1kWh per load, or 23.8 billion kWh per year. In addition, it is envisioned that the proposed ESP, when successful, would potentially find applications in industrial and residential dehumidification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Photovoltaic Adoption in the Southeastern United States

Solar market analysis typically focuses on states with large solar installations in the Western states, notably California, the Northeast, namely Massachusetts, and two states in the Southern US: Florida and North Carolina. Herein we examine the solar PV industry and trends in capacity, production and incentives within the Southeastern US and provide an examination of how existing solar policy has influenced penetration on a state by state basis. In particular, why some states such as South Carolina have high residential solar capacity, while neighboring states, North Carolina and Georgia have high utility-scale penetration. Incentives developed in South Carolina through legislative action have increased solar PV residential installations dramatically since 2015, while utility scale installations continue to grow in North Carolina. North Carolina has the highest growth in non-residential (commercial and industrial) and utility-scale solar PV. It was found that for the residential sector, highest solar PV growth occurs when a) the federal tax credit is augmented with a state-wide tax credit, b) enabling state laws, and c) net-metering and solar leasing programs.

14 SOLAR ENERGY↗

A Retrospective Analysis of Distributed Solar Interconnection Timelines and Related State Mandates

Most distributed residential photovoltaic (PV) systems must secure an interconnection agreement prior to operation that ensures the local electrical system will operate safely within the broader electrical grid. PV installers generally submit an interconnection application to the local utility that provides all the necessary details the utility needs to evaluate the proposed system. To encourage timely execution of this process, many states’ utility commissions have established mandates that limit the maximum number of days allowed for utility review and approval of interconnection for certain small, often residential applications. In this paper, we derive the median and range of cycle times for the pre-installation approval phase of the interconnection process (i.e., from application submission to approval by the utility) across 24 U.S. states, using a data set of approximately 170,000 projects. We evaluate the percentage of projects that are approved within respective state-mandated timelines from 2017– 2019. We further evaluate how timelines have evolved since 2012 for a subset of five states: Arizona, California, Colorado, New Jersey, and New York. The analyses are divided into two size ranges: systems that are ≤10 kilowatts (kW), and systems that are 11–50 kW.

14 SOLAR ENERGY↗

Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial construction. Such products typically consist of five layers installed over the top of a water resistive barrier as follows: (1) Adhesive (2) Foam insulation (3) Base coat (4) Reinforcing mesh embedded in the base coat (5) Top or finish coat. They can be applied to new or existing buildings that employ wood or masonry construction, and can utilize an insulation thickness of up to 16 in. However, such systems are rarely used in lowrise residential retrofits. Reasons for this might include a lack of demand for or knowledge of the systems in residential retrofit industry, high cost, and/or lack of suitable distribution channels serving the residential market. While the final appearance of an EIFS installation resembles stucco, it is a distinctly different system. Stucco is a generic cementitious-based material, whereas EIFSs are proprietary synthetic formulations distributed by manufacturers to a network of authorized applicators. An EIFS is composed of polymeric (organic) bonded aggregate and cement reinforced with a glass mesh. Stucco is made of inorganic cement, sand, and lime. In this project, a home was retrofitted using a site-applied 4-in.-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS were documented. The case study home was modeled using version 2 of the National Renewable Energy Laboratory-developed Building Energy Optimization (BEopt) energy and cost analysis software. While a package utilizing the 4-in. EIFS is the optimal retrofit of the options analyzed in terms of annualized energy-related costs, it is higher cost than replacing the siding with midrange vinyl alone. However, compared to high-end vinyl, the EIFS package has a lower annualized energy cost. This held true for both the Islip, New York (climate zone 4) and Boston (climate zone 5) case studies. The report discusses the risks, selection criteria, interactions with other building systems, cost, performance, and other aspects of using an EIFS in a deep energy retrofit. EIFSs do not require special site safety precautions beyond general construction site precautions. Moisture design is important. Trapping moisture between two vapor/air barriers is a risk of all wall systems, including EIFS cladding applications if an interior vapor barrier exists and if there is not adequate ventilation through the drainage plane behind the insulation layer. Face-sealed approaches that rely on exposed sealants do not provide acceptable rain control or durability and are very risky. Generally, fire codes permit EIFSs for most building types and conditions.

airtightness↗

Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life

In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. In this project, the U.S. Department of Energy Building America team Partnership for Advanced Residential Retrofit examined the impact that common installation practices and age-induced equipment degradation may have on the installed performance of natural gas furnaces over the life of the product, as measured by steady-state efficiency and annual efficiency. The team identified 12 furnaces of various ages and efficiencies that were operating in residential homes in the Des Moines, Iowa, metropolitan area and worked with a local heating, ventilation, and air conditioning contractor to retrieve furnaces and test them at the Gas Technology Institute laboratory for steady-state efficiency and annual efficiency. Prior to removal, system airflow, static pressure, equipment temperature rise, and flue loss measurements were recorded for each furnace as installed in the house.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing suburban soil and microbial properties along a soil age chronosequence

Abstract Rapid urbanization is drastically altering ecosystem processes in landscapes around the world. In particular, suburban residential neighborhoods comprise novel ecosystems with water and nutrient inputs that differ greatly from the surrounding land area. These impacts generate concern over the sustainability of urban ecosystems, especially whether they will be characterized by net carbon gain or loss over time. To address this knowledge gap, we established a chronosequence of residential yards in Southern California to test how urban soils change after development. We predicted that urbanized soils would experience shifts in physical characteristics and microbial function over time consistent with ecological succession theory, but residential soils would maintain novel moisture and nutrient regimes compared to undeveloped soils, never “recovering” to a pre‐developed state. We compared different vegetation types to quantify impacts of homeowner landscaping choices and characterized yard soils and their microbial communities. We found that yard soils were nutrient‐ and moisture‐enriched compared to an adjacent undeveloped ecosystem, and turfgrass was associated with higher levels of water and nitrogen. Despite high respiration rates, yard soils accumulated carbon and nitrogen over time. We conclude that suburban residential soils comprise dynamic and heterogeneous ecosystems that are highly influenced by landscaping choices and management practices, and warrant closer study at small management‐relevant scales.

Suratt, Andie [Department of Ecology and Evolution↗

Impact of model predictive control-enabled home energy management on large-scale distribution systems with photovoltaics

Residential customers use more than one-quarter of the electricity in the world. Optimally managing home energy consumption is an effective way of easing the operational challenges facing the electric grid with increasing solar photovoltaics (PV). This paper studies the impact of the future proliferation of home energy management systems (HEMS) in the presence of PV on large-scale distribution systems. First, we present a stochastic HEMS model that minimizes residential customers' thermal discomfort and energy costs under uncertainty. The HEMS model schedules the optimal operations of residential appliances in the presence of PV within a mixed-integer linear programming-based model predictive control framework that links the proposed HEMS to a quasi-steady-state time-series simulation tool. Additionally, extensive simulations are conducted for a stand-alone residential home using two tariff structures and for 1977 homes on an 8,500-node distribution feeder. Simulation results quantify the impact of the future proliferation of HEMS on the large-scale distribution system with PV.

14 SOLAR ENERGY↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗

Source Contributions to Fine Particulate Matter and Attributable Mortality in India and the Surrounding Region

Fine particulate matter (PM 2.5 ) is a leading mortality risk factor in India and the surrounding region of South Asia. This study evaluates the contribution of emission sectors and fuels to PM 2.5 mass for 29 states in India and 6 surrounding countries (Pakistan, Bangladesh, Nepal, Bhutan, Sri Lanka, and Myanmar) by combining source-specific emission estimates, stretched grid simulations from a chemical transport model, high resolution hybrid PM 2.5 , and disease-specific mortality estimates. We find that 1.02 (95% Confidence Interval (CI): 0.78-1.26) million deaths in South Asia attributable to ambient PM 2.5 in 2019 were primarily from three leading sectors: residential combustion (28%), industry (15%), and power generation (12%). Solid biofuel is the leading combustible fuel contributing to the PM 2.5 -attributable mortality (31%), followed by coal (17%), and oil and gas (14%). State-level analyses reveal higher residential combustion contributions (35%-39%) in states (Delhi, Uttar-Pradesh, Haryana) with high ambient PM 2.5 (>95 µg/m 3 ). The combined mortality burden associated with residential combustion (ambient) and household air pollution (HAP) in India is 0.72 million (95% CI:0.54-0.89) (68% attributable to HAP, 32% attributable to residential combustion). Our results illustrate the potential to reduce PM 2.5 mass and improve population health by reducing emissions from traditional energy sources across multiple sources in South Asia.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Fabric properties and electric efficiency limits of mechanical moisture extraction from fabrics

Residential clothes drying consume about 650 TBtu of primary energy per year in the United States, equivalent to 3% of primary residential energy consumption. There is a strong impetus to reduce the energy consumption of clothes dryers by both improving existing technology and developing alternatives that use fundamentally different drying mechanisms. Clothes drying technologies are broadly classified into either evaporative or mechanical drying. The focus of this paper is on mechanical drying, including vibrational, centrifugal, and press-based methods. In this work, the physical processes involved in these mechanical fabric drying processes were analyzed to develop general theories of mechanical cloth drying energy efficiency. Quantitative evaluation of the theories requires measured fabric properties. To accomplish this, a set of experiments was conducted on samples of a standard test fabric. The fabric was a cotton-polyester blend specified by the US Department of Energy to evaluate the standardized efficiency of all residential clothes dryers in the US. Mercury porosimetry experiments were conducted to determine the fabric pore size distribution, apparent density, and porosity. Elasticity experiments were conducted to determine the fabric’s Young’s modulus. Isostatic press experiments were conducted to establish a relationship between compression force and fabric moisture content. The data resulting from these experiments were combined with mathematical models developed in this work to calculate the theoretical maximum performance limits for mechanical drying of the standard fabric. The results of the analysis are used to make recommendations for the most promising technologies that offer the greatest potential energy savings for residential clothes drying.

36 MATERIALS SCIENCE↗

Scalable Hybrid Classification-Regression Solution for High-Frequency Nonintrusive Load Monitoring

Residential buildings with the ability to monitor and control their net-load (sum of load and generation) can provide valuable flexibility to power grid operators. We present a novel multiclass nonintrusive load monitoring (NILM) approach that enables effective net-load monitoring capabilities at high-frequency with minimal additional equipment and cost. The proposed machine learning based solution provides accurate multiclass state predictions while operating at a faster timescale (able to provide a prediction for each 60- Hz ac cycle used in US power grid) without relying on event-detection techniques. We also introduce an innovative hybrid classification-regression method that allows for the prediction of not only load on/off states but also individual load operating power levels. A test bed with eight residential appliances is used for validating the NILM approach. Results show that the overall method has high accuracy, good scaling and generalization properties.

feature extraction↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

Interconnection of Three Single-Phase Feeders in North America Distribution Systems

This paper proposes a solution for maintaining power balance within all three phases at residential level during islanded mode of operation. Grid abnormalities can lead to isolating the residential microgrid from the main grid, and as a result, distributed generation (DG) units take the full responsibility of supplying local loads. However, in such condition, some phases might face the challenge of meeting local load demand due to the lack of enough power generation, resulting in voltage drop and frequency variation across household loads. In order to resolve this issue, the proposed method in this paper seamlessly interconnects all three single-phase feeders during islanded mode and forms a unified single-phase residential microgrid. Consequently, the load demands in all three phases are met, leading to enhanced voltage and frequency profiles. For this purpose, a seamless transition algorithm is defined which monitors the system condition in real time, and coordinates the operation of all inverter-based DG units in residential microgrid accordingly during transitions. Case study results are provided to verify the validity of proposed method.

Pilehvar, Mohsen S.↗

Energy Transmission and Infrastructure Northern Ohio (OH)

The objective of Energy Transmission and Infrastructure Northern Ohio (OH) was to lay the conceptual and analytical foundation for an energy economy in northern Ohio that will: • improve the efficiency with which energy is used in the residential, commercial, industrial, agricultural, and transportation sectors for Oberlin, Ohio as a district-wide model for Congressional District OH-09; • identify the potential to deploy wind and solar technologies and the most effective configuration for the regional energy system (i.e., the ratio of distributed or centralized power generation); • analyze the potential within the district to utilize farm wastes to produce biofuels; • enhance long-term energy security by identifying ways to deploy local resources and building Ohio-based enterprises; • identify the policy, regulatory, and financial barriers impeding development of a new energy system; and • improve energy infrastructure within Congressional District OH-09. This objective of laying the foundation for a renewable energy system in Ohio was achieved through four primary areas of activity: 1. district-wide energy infrastructure assessments and alternative-energy transmission studies; 2. energy infrastructure improvement projects undertaken by American Municipal Power (AMP) affiliates in the northern Ohio communities of Elmore, Oak Harbor, and Wellington; 3. Oberlin, OH-area energy assessment initiatives; and 4. a district-wide conference held in September 2011 to disseminate year-one findings. The grant supported 17 research studies by leading energy, policy, and financial specialists, including studies on: current energy use in the district and the Oberlin area; regional potential for energy generation from renewable sources such as solar power, wind, and farm-waste; energy and transportation strategies for transitioning the City of Oberlin entirely to renewable resources and considering pedestrians, bicyclists, and public transportation as well as drivers in developing transportation policies; energy audits and efficiency studies for Oberlin-area businesses and Oberlin College; identification of barriers to residential energy efficiency and development of programming to remove these barriers; mapping of the solar-photovoltaic and wind-energy supply chains in northwest Ohio; and opportunities for vehicle sharing and collaboration among the ten organizations in Lorain County from the private, government, non-profit, and educational sectors. With non-grant funds, organizations have begun or completed projects that drew on the findings of the studies, including: creation of a residential energy-efficiency program for the Oberlin community; installation of energy-efficient lighting in Oberlin College facilities; and development by the City of Oberlin and Oberlin College of a 2.27 megawatt solar photovoltaic facility that is expected to produce 3,000 megawatt-hours of renewable energy annually, 12% of the College’s yearly power needs. Implementation of these and other projects is evidence of the economic feasibility and technical effectiveness of grant-supported studies, and additional projects are expected to advance to implementation in the coming years. The public has benefited through improved energy-delivery systems and reduced energy use for street lighting in Elmore, Oak Harbor, and Wellington; new opportunities for assistance and incentives for residential energy efficiency in the Oberlin community; new opportunities for financial and energy savings through vehicle collaboration within Lorain County; and decreased reliance on fossil fuels and expanded production of renewable energy in the region. The dissemination conference and the summary report developed for the conference also benefited the public, but making the findings and recommendations of the regional studies broadly available to elected officials, city managers, educators, representatives of the private sector, and the general public.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗