Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

A portable cryostat for the cold transfer of polarized solid HD targets: HDice-I

We developed a device with moveable liquid nitrogen and liquid helium volumes that is capable of reaching over 2 m into the coldest regions of a cryostat or dilution refrigerator and reliably extracting or installing a target of solid, polarized hydrogen deuteride (HD). This Transfer Cryostat incorporates a cylindrical neodymium rare-earth magnet that is configured as a Halbach dipole, which is maintained at 77 K and produces a 0.1 T field around the HD target. Multiple layers provide a hermetic 77 K-shield as the device is used to maintain a target at 2 K during a transfer between cryostats. Our tests with frozen-spin HD show very little polarization loss for either H (-1±2%, relative) or D (0±3%, relative) over typical transfer periods. Multiple target transfers with this apparatus have shown an overall reliability of about 95% per transfer, which is a significant improvement over earlier versions of the device.

42 ENGINEERING↗

Flow maldistribution in plate heat exchangers – Impact, analysis, and solutions

Plate heat exchangers are commonly used in various industrial applications, such as refrigeration, air conditioning, heat pumps, powerplants, and chemical industries. Plate heat exchangers are well known for their superior heat transfer performance, compactness, and low refrigerant charge. Despite offering several advantages, they suffer from flow maldistribution issues. The flow maldistribution can deteriorate both the heat transfer and pressure drop performance, ultimately resulting in a lower system efficiency where plate heat exchangers are deployed. The flow maldistribution issues become more pronounced when the heat exchanger size is relatively large and the number of plates is higher, limiting the deployment of plate heat exchangers in larger industrial systems. Consequently, analyzing and understanding the flow maldistribution behavior in plate heat exchangers and finding ways to mitigate flow maldistribution related issues become essential topics of interest. Further, this review aims to address the effect of flow maldistribution on plate heat exchanger characteristics. First, the experimental and numerical works on flow maldistribution under single-phase and two-phase conditions are detailed. Subsequently, the end-channel and end-plate effects are discussed. Then, the methods to mitigate flow maldistribution in plate heat exchangers are outlined. Finally, based on a thorough literature survey and industrial requirements, future research directions are recommended.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecular Insight into Fluorocarbon Adsorption in Pore Expanded Metal–Organic Framework Analogs

The rapid growth in the global energy demand for space cooling requires the development of more efficient environmental chillers for which adsorption-based cooling systems can be utilized. Here, in this contribution, we explore sorbents for chiller use via a pore-engineering concept to construct analogs of the 1-dimensional pore metal–organic framework MOF-74 by using elongated organic linkers and stereochemistry control. The prepared pore-engineered MOFs show remarkable equilibrium adsorption of the selected fluorocarbon refrigerant that is translated to a modeled adsorption-based refrigeration cycle. To probe molecular level interactions at the origin of these unique adsorption properties for this series of Ni-MOFs, we combined in situ synchrotron X-ray powder diffraction, neutron powder diffraction, X-ray absorption spectroscopy, calorimetry, Fourier transform infrared techniques, and molecular simulations. Our results reveal the coordination of fluorine (of CH2F in R134a) to the nickel(II) open metal centers at low pressures for each Ni-MOF analog and provide insight into the pore filling mechanism for the full range of the adsorption isotherms. The newly designed Ni-TPM demonstrates exceptional R134a adsorption uptake compared to its parent microporous Ni-MOF-74 due to larger engineered pore size/volume. The application of this adsorption performance toward established chiller conditions yields a working capacity increase for Ni-TPM of about 400% from that of Ni-MOF-74, which combined with kinetics directly correlates to both a higher coefficient of performance and a higher average cooling capacity generated in a modeled chiller.

Zheng, Jian↗

Magnetocaloric effect in Mn-rich Heusler-derived alloys for room temperature-based applications

Magnetic refrigeration-based technologies rely on the magnetocaloric properties of materials and are crucial for improving energy efficiency and for supporting clean environments. However, materials possessing significant magnetocaloric properties that can be used for room temperature-based applications are still lacking. Heusler alloys (such as Mn–Ni–Ga) show giant magnetocaloric effects, which can be further improved by tuning their composition. Herein, we optimized the ratio of Ni to Ga to achieve an alloy with unique magnetocaloric properties. Here, the alloy demonstrated a substantial magnetocaloric effect, attributed to its narrow temperature range for structural and magnetic phase transitions (near room temperature with minimal hysteresis). Structural phase changes were also observed through high-resolution transmission electron microscopy. Optimum entropy changes, calculated from isothermal magnetization curves (4 Tesla magnetic field), were found to be 24.50 J kg −1 K −1 , which is higher than that of state-of-the-art alloys. Experimental demonstration of the magnetocaloric effect (refrigeration cycle) was also carried out using a thermal imaging camera. Furthermore, first-principles calculations were conducted to validate the experimental findings, specifically focusing on the compositional effects on the structural transitions and magnetic properties of the investigated MNG alloys.

36 MATERIALS SCIENCE↗

Magnetocaloric effect observations near room temperature in few-layered chromium telluride (Cr 2 Te 3 )

Transition metal telluride compositions are explored extensively for their unique magnetic behavior. Few-layered chromium telluride (Cr 2 T e3 ) exhibits a near-room-temperature phase transition, where the material can be effectively used in applications such as magnetic refrigeration. Compared to existing magnetocaloric materials, Heusler alloys, and rare-earth-based alloys, the large-scale synthesis of mechanically exfoliated Cr 2 Te 3 involves less complexity, resulting in a stable composition. Compared to existing tellurides, Cr 2 Te 3 exhibited a large change in magnetic entropy (|ΔS M |) of 1.88 J k g−1 K −1 at a magnetic field of 4 T. A refrigeration capacity (RC) of ∼82 J kg −1 was determined from the change in magnetic entropy versus temperature curve. The results were comparable with those for existing Cr-based compounds. First-principles density functional theory (DFT) confirmed the magnetic properties of Cr 2 Te 3 , including a near-room-temperature Curie temperature, T C , consistent with experimental results. Here, structural transition was also observed using first-principles DFT, which is responsible for the magnetic behavior.

36 MATERIALS SCIENCE↗

A compact flexible pellet injector for the TJ-II stellarator

A compact pellet injector is being built for the TJ-II stellarator. It is an upgraded version of the 'pellet injector in a suitcase' developed at Oak Ridge National Laboratory and installed on the Madison Symmetric Torus where it continues to be used in many plasma experiments. The design aim is to provide maximum flexibility at minimal cost, while allowing for future upgrades. It is a four-barrel system equipped with a cryogenic refrigerator for in situ hydrogen pellet formation, a combined mechanical punch/propellant valve system, pellet diagnostics, and an injection line, destined for use as an active diagnostic and for fueling. In order to fulfill both objectives it will be sufficiently flexible to permit pellets, with diameters from 0.4 to 1 mm, to be fabricated and accelerated to velocities from 150 to {approx}1000 m s{sup -1}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a low-temperature photoelectron spectroscopy instrument using an electrospray ion source and a cryogenically controlled ion trap

The ability to control ion temperatures is critical for gas phase spectroscopy and has been a challenge in chemical physics. A low-temperature photoelectron spectroscopy instrument has been developed for the investigation of complex anions in the gas phase, including multiply charged anions, solvated species, and biological molecules. The new apparatus consists of an electrospray ionization source, a three dimensional (3D) Paul trap for ion accumulation and cooling, a time-of-flight mass spectrometer, and a magnetic-bottle photoelectron analyzer. A key feature of the new instrument is the capability to cool and tune ion temperatures from 10 to 350 K in the 3D Paul trap, which is attached to the cold head of a closed cycle helium refrigerator. Ion cooling is accomplished in the Paul trap via collisions with a background gas and has been demonstrated by observation of complete elimination of vibrational hot bands in photoelectron spectra of various anions ranging from small molecules to complex species. Further evidence of ion cooling is shown by the observation of H{sub 2}-physisorbed anions at low temperatures. Cold anions result in better resolved photoelectron spectra due to the elimination of vibrational hot bands and yield more accurate energetic and spectroscopic information. Temperature-dependent studies are made possible for weakly bonded molecular and solvated clusters, allowing thermodynamic information to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution x-ray spectroscopy with the EBIT Calorimeter Spectrometer

The EBIT Calorimeter Spectrometer (ECS) is a production-class 36 pixel x-ray calorimeter spectrometer that has been continuously operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory for almost 2 years. The ECS was designed to be a long-lifetime, turn-key spectrometer that couples high performance with ease of operation and minimal operator intervention. To this end, a variant of the Suzaku/XRS spaceflight detector system has been coupled to a low-maintenance cryogenic system consisting of a long-lifetime liquid He cryostat, and a closed cycle, {sup 3}He pre-cooled adiabatic demagnetization refrigerator. The ECS operates for almost 3 weeks between cryogenic servicing and the ADR operates at 0.05 K for more than 60 hours between automatic recycles under software control. Half of the ECS semiconductor detector array is populated with mid-band pixels that have a resolution of 4.5 eV FWHM, a bandpass from 0.05-12 keV, and a quantum efficiency of 95% at 6 keV. The other half of the array has thick HgTe absorbers that have a bandpass from 0.3 to over 100 keV, an energy resolution of 33 eV FWHM, and a quantum efficiency of 32% at 60 keV. In addition, the ECS uses a real-time, autonomous, data collection and analysis system developed for the Suzaku/XRS instrument and implemented in off-the-shelf hardware for the ECS. Here we will discuss the performance of the ECS instrument and its implementation as a turnkey cryogenic detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent advances in the microstructure design of materials for near room temperature magnetic cooling (invited)

Successful operation of a magnetic cooling device depends crucially on the performance of active magnetic refrigerant material. Extensive research activity has been concentrated on optimizing the magnetic properties of these materials by chemical composition modification. Here, it is shown how the design of appropriate microstructure can be used to control the magnetic properties as well as mechanical stability of refrigerant materials experiencing a first-order magnetic phase transition. In particular, introducing porosity in LaFe{sub 13-x}Si{sub x} alloys provides long-term stability by sacrificing only a small fraction of the magnetocaloric effect and results in the desired reduction of the magnetic and thermal hysteresis by a factor of 5, as compared to bulk alloys. Reducing crystallite size down to the nanometer range is shown to substantially lower magnetic hysteresis. On the other hand, the magnetocaloric effect is weakened by about 40% and 60% in alloys with grain size of 70 and 44 nm, respectively.

36 MATERIALS SCIENCE↗

Status of cryogenic system for spallation neutron source's superconducting radiofrequency test facility at Oak Ridge National Lab

The Spallation Neutron Source (SNS) at Oak Ridge National Lab (ORNL) is building an independent cryogenic system for its Superconducting Radiofrequency Test Facility (SRFTF). The system will provide refrigeration for the SNS cryomodule test and cavity test at both 2K (using vacuum pumped helium) and 4.5K for the maintenance purposes and the Power Upgrade Project of SNS. It will also provide the part of the cooling power needed to backup the existing CHL to keep the Linac at 4.5K during CHL future maintenance periods. The system will be constructed in multiple phases. The first phase is to construct an independent 4.5K helium refrigeration system with a helium Dewar and distribution box as the load interface. It is scheduled to be commissioned in 2013. Here we report on the design concept for the system and the status of the first phase of this project.

Xu, Ting↗

Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples

High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °C ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the magnetocaloric entropy change by field sweep using a heat flux setup

We report on a simple setup using a heat flux sensor adapted to a Quantum Design Physical Property Measurement System to determine the magnetocaloric entropy change (ΔS). The major differences for the existing setups are the simplicity of this assembly and the ease to obtain the isothermal entropy change either by a field sweep or a temperature sweep process. We discuss the use of these two processes applied to Gd and Gd{sub 5}Ge{sub 2}Si{sub 2} samples. The results are compared to the temperature sweep measurements and they show the advantages of this setup and of the field sweep procedure. We found a significant reduction of ΔS and on the refrigerating cooling power (RCP) at low field changes in a field sweep process when the sample is not driven to the same initial state for each temperature. We show that the field sweep process without any measuring protocol is the only correct way to experimentally determine ΔS and RCP for a practical regenerative refrigerator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gd 5 (Si,Ge) 4 thin film displaying large magnetocaloric and strain effects due to magnetostructural transition

Magnetic refrigeration based on the magnetocaloric effect is one of the best alternatives to compete with vapor-compression technology. Despite being already in its technology transfer stage, there is still room for optimization, namely, on the magnetic responses of the magnetocaloric material. In parallel, the demand for different magnetostrictive materials has been greatly enhanced due to the wide and innovative range of technologies that emerged in the last years (from structural evaluation to straintronics fields). In particular, the Gd 5 (Si x Ge 1–x ) 4 compounds are a family of well-known alloys that present both giant magnetocaloric and colossal magnetostriction effects. Despite their remarkable properties, very few reports have been dedicated to the nanostructuring of these materials: here, we report a ~800 nm Gd 5 Si 2.7 Ge 1.3 thin film. The magnetic and structural investigation revealed that the film undergoes a first order magnetostructural transition and as a consequence exhibits large magnetocaloric effect (–ΔS mMAX ~8.83 J kg –1 K –1 , ΔH = 5T) and giant thermal expansion (12000 p.p.m). The thin film presents a broader magnetic response in comparison with the bulk compound, which results in a beneficial magnetic hysteresis reduction. The ΔS mMAX exhibited by the Gd 5 (Si,Ge) 4 thin film makes it a promising candidate for micro/nano magnetic refrigeration area.

36 MATERIALS SCIENCE↗

Sub-Kelvin magnetic and electrical measurements in a diamond anvil cell with in-situ tunability

We discuss techniques for performing continuous measurements across a wide range of pressure-field-temperature phase space, combining the milli-Kelvin temperatures of a helium dilution refrigerator with that of the giga-Pascal pressures of a diamond anvil cell and the Tesla magnetic fields of a superconducting magnet. With a view towards minimizing remnant magnetic fields and background magnetic susceptibility, we then characterize high-strength superalloy materials for the pressure cell assembly, which allows high fidelity measurements of low-field phenomena such as superconductivity below 100 mK at pressures above 10 GPa. In situ tunability and measurement of the pressure permit experiments over a wide range of pressure, while at the same time making possible precise steps across abrupt phase transitions such as that from insulator to metal.

36 MATERIALS SCIENCE↗

Millikelvin cooling by heavy-fermion-based tunnel junctions

This paper addresses a high-performance electron-tunneling cooler based on a novel heavy-fermion/insulator/superconductor junction for millikelvin cooling applications. We show that the cooling performance of an electronic tunneling refrigerator could be significantly improved using a heavy-fermion metal to replace the normal metal in a conventional normal metal/insulator/superconductor junction. The calculation, based on typical parameters, indicates that, for a bath temperature of 300 mK, the minimum cooling temperature of an electron tunneling refrigerator is reduced from around 170 mK to below 50 mK if a heavy-fermion metal is employed in place of the normal metal. The improved cooling is attributed to an enhancement in electron tunneling due to the existence of a resonant density of states at the Fermi level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of Gd substitution on the structural, magnetic, and magnetocaloric properties of HoCrO 3

Rare-earth chromites are a novel type of magnetoelectric multiferroics. Here, a Ho 0.33 Gd 0.67 CrO 3 powder sample was synthesized via a citrate route, and the structural properties were characterized by X-ray diffraction, scanning electron microscopy, and the Raman technique. The UV-Visible optical absorbance spectra were also measured in the wavelength range of 200–800 nm. The valence state of Cr was found to be purely 3+ according to the X-ray photoelectron spectroscopy. The temperature-dependent dielectric constant and loss tangent data measured between the frequencies of 1 kHz and 1 MHz show no anomalies around the magnetic transition temperature of the material. The dc magnetization measurements show that the ordering temperature of Cr 3+ ( T N C r ) is 155 K for Ho 0.33 Gd 0.67 CrO 3 , which is larger than 140 K for HoCrO 3 . The positive slope of the Arrott plots from 0 T to 7 T reveals that the antiferromagnetic-paramagnetic phase transition is second-order in nature. At a field of 7 T, the Ho 0.33 Gd 0.67 CrO 3 sample showed a giant magnetocaloric entropy change, -ΔS, of ~23.3 J/kg K at 5 K, and a refrigeration capacity of ~481.2 J/kg, which are much higher than those of pure bulk HoCrO 3 . This renders this material prospective for magnetic refrigeration in the low temperature (<30 K) range.

36 MATERIALS SCIENCE↗

Significant enhancement of magnetocaloric effect in a NiMnCuGa Heusler alloy through textural modification

Magnetocaloric materials are of increasing interest to bring magnetic refrigeration to everyday households and drastically impact the energy demands for temperature control devices. In this work, a polycrystalline Heusler alloy of composition Ni2Mn0.76Cu0.24Ga with coinciding structural and magnetic transformation temperatures was subjected to compressive stress assisted thermal cycling (SATC) to enhance the magnetic properties by inducing a preferred orientation in the martensite. Isofield magnetization measurements showed a sharpening of the transformation between ferromagnetic martensite and paramagnetic austenite due to SATC. In isothermal magnetization measurements, SATC was seen to increase the magnetostructural coupling. With a 2 T applied magnetic field, the magnetocaloric effect (MCE) increased from ∼10 to ∼25 J/kg K and the refrigeration capacity (RC) almost doubled due to SATC. Heat capacity measurements were largely unaffected by SATC. The change in adiabatic temperature was estimated by using Cp and change in magnetic entropy (ΔSM) calculations. SATC was seen to increase ΔTad from ∼1.2 K to 2 K for an applied magnetic field of 2 T. Neutron diffraction measurements revealed highly textured martensite in the as received state that rotated to a more ideal preferred orientation after SATC that enhanced the magnetostructural transformation; and thus, improving the MCE and ΔTad.

McLeod, M. V. (ORCID:0000000329883516)↗

Simulation and Experimental Study of Metal Organic Frameworks Used in Adsorption Cooling

Metal-organic frameworks (MOFs) have recently attracted enormous interest over the past few years in energy storage and gas separation, yet there have been few reports for adsorption cooling applications. Adsorption cooling technology is an established alternative to mechanical vapor compression refrigeration systems and is an excellent alternative in industrial environments where waste heat is available. We explored the use of MOFs that have very high mass loading and relatively low heats of adsorption, with certain combinations of refrigerants to demonstrate a new type of highly efficient adsorption chiller. Computational fluid dynamics combined with a system level lumped-parameter model have been used to project size and performance for chillers with a cooling capacity ranging from a few kW to several thousand kW. These systems rely on stacked micro/mini-scale architectures to enhance heat and mass transfer. Recent computational studies of an adsorption chiller based on MOFs suggests that a thermally-driven coefficient of performance greater than one may be possible, which would represent a fundamental breakthrough in performance of adsorption chiller technology. Presented herein are computational and experimental results for hydrophyilic and fluorophilic MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗