Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

SU-F-T-27: A Comparative Case Study Among Four Modalities for the Superficial Treatment of Squamous Cell Carcinoma

Purpose: We performed a comparative planning study among High Dose Rate (HDR) brachytherapy, superficial electrons, Volume Modulated Arc Therapy (VMAT), and Helical IMRT (Tomotherapy) for squamous cell carcinoma of the abdominal wall with consideration for the underlining bowel. Methods: A 69-year old female presented with squamous cell carcinoma protruding 8mm beyond the anterior skin surface of the midabdomen was considered for treatment. The patient had a ventral hernia which resulted in the reduction of the abdominal wall thickness and the adjacent small bowel being the dose limiting structure. Four plans were generated using different treatment modalities: a) an enface electron field (eMC, Eclipse v. 11), b) Tomotherapy (HI-Art II v.5.0.5), c) VMAT (Acuros, Eclipse v. 11), and d) HDR using a Freiburg applicator (Oncentra v. 4.3). The following plan objectives were used for all four plans: for the CTV target, V90% ≥90% (61.8Gy2/2).For the small bowel, D0.1cc < 56.2 Gy2/2 was a hard constraint and expressed as a percentage of the prescription for comparison to demonstrate the dose fall-off achieved among the modalities.For HDR, V200% <0.1cc was an additional constraint. Multiple dosimetric parameters, including those listed above, were compared among the four modalities. Results: The HDR plan showed comparable target coverage compared to the Tomotherapy plan and better coverage compared to the electron plan. Small bowel doses (D0.1cc) were lower in HDR plan compared to Tomotherapy, electron, & VMAT plans (88.8%, 89.6%, 90.9%, & 96.6%). Integral dose to the whole body (V5%) was much higher for HDR, VMAT, and Tomotherapy when compared to electron plan by factors of seven, eight, and ten, respectively. After reviewing all treatment modalities, the physician selected HDR owing to better control of the small bowel dose while maintaining adequate target coverage. Conclusion: This case study demonstrated HDR can successfully treat superficial lesions with superior sparing of underlying structures.

60 APPLIED LIFE SCIENCES↗

Is Routine Splenectomy Justified for All Left-Sided Pancreatic Cancers? Histological Reappraisal of Splenic Hilar Lymphadenectomy

Background: Although splenectomy is recommended during resection for left-sided resectable pancreatic ductal adenocarcinoma (PDAC) to perform lymphadenectomy of station 10 (splenic hilum), no level I evidence justifies this procedure. This study aims to evaluate the rate of lymph node (LN) and contiguous involvement of the splenic hilum in resectable distal PDAC. Methods: We retrospectively reviewed all patients who underwent splenopancreatectomy for PDAC in the past 10 years. Station 10 LN were routinely isolated, and all corresponding microscopic slides were reinterpreted by a pathologist. The computed tomography (CT) results of patients with tumoral involvement of the spleen or splenic hilum by contiguity (TISOSH) and ≤ 10 mm between the tumor and spleen on pathology were blindly reviewed by two radiologists to evaluate CT for diagnosis of TISOSH. Results: We included 110 consecutive patients, including 104 with analyzable station 10 LN. The tumor was N+ in 58 (53%) patients. The median number of LN identified at station 10 was 2.0 ± 3.0. No station 10 LNs were detected in 42 (40%) patients. No patients had tumor-positive LN at station 10. TISOSH was found in nine (8%) patients, and was significantly associated with tail location (p = 0.001), tumor size (p = 0.005), and multivisceral involvement (p = 0.015). For diagnosis of TISOSH, the sensitivity and specificity of CT were respectively 89% and 95% for radiologist 1 and 89% and 100% for radiologist 2. Conclusions: Splenic preservation during resection of distal PDAC may be an option in selected patients with body tumors and no suspected splenic or splenic hilum involvement on preoperative CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overuse of Preoperative Staging of Patients Undergoing Neoadjuvant Chemotherapy for Breast Cancer

Background: Guidelines of the American Society of Clinical Oncology (ASCO), the National Comprehensive Cancer Network (NCCN), and the European Society for Medical Oncology (ESMO) discourage the use of imaging to stage newly diagnosed early breast cancer (stages 1 and 2). This study aimed to evaluate preoperative staging imaging rates among patients with stage 1 or 2 breast cancer treated with neoadjuvant chemotherapy (NAC). Methods: From a prospectively maintained database, 303 patients with stage 1 or 2 breast cancer who had NAC from 2008 to 2016 were identified. The main outcome measures were the rate and outcomes of staging imaging performed. Results: The mean age of the 303 patients with stage 1 or 2 breast cancer was 51 years (range, 26–87 years). Of these 303 patients, 278 (92.4%) had invasive ductal cancer. 90 (30.2%) had estrogen receptor (ER)-positive disease, 79 (26.5%) had triple-negative disease, and 127 (42.6%) had human epidermal growth factor receptor 2 (HER2)-positive disease. Staging positron emission tomography (PET) or computed tomography (CT) scan was performed for 258 patients (85.2%), brain imaging for 94 patients (31%), bone scans for 117 patients (38.6%), and all three for 48 patients (15.8%). As a result, 15 patients (4.9%) with a positive PET/CT scan were upstaged to stage 4 breast cancer. No difference was observed among the ER-positive (p = 1.000), HER2-positive (p = 0.259), or triple-negative (p = 0.369) receptor profiles of the patients upstaged to stage 4 disease. One patient (1.1%) had positive brain imaging. Five patients (4.3%) had a positive bone scan, and three of these patients (60%) had bone metastasis also shown on the PET/CT scan. Conclusion: Despite guideline recommendations, a high rate of preoperative staging imaging is completed for patients with clinical stage 1 or 2 breast cancer who receive NAC, with few positive results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Automated Dissolution and Analysis Techniques for Radionuclides in Recycle Process Streams

The analysis of process samples for radionuclide content is an important part of current procedures for material balance and accountancy in the different process streams of a recycling plant. The destructive sample analysis techniques currently available necessitate a significant amount of time. It is therefore desirable to develop new sample analysis procedures that allow for a quick turnaround time and increased sample throughput with a minimum of deviation between samples. In particular, new capabilities for rapid sample dissolution and radiochemical separation are required. Most of the radioanalytical techniques currently employed for sample analysis are based on manual laboratory procedures. Such procedures are time- and labor-intensive, and not well suited for situations in which a rapid sample analysis is required and/or large number of samples need to be analyzed. To address this issue we are currently investigating radiochemical separation methods based on extraction chromatography that have been specifically optimized for the analysis of process stream samples. The influence of potential interferences present in the process samples as well as mass loading, flow rate and resin performance is being studied. In addition, the potential to automate these procedures utilizing a robotic platform is evaluated. Initial studies have been carried out using the commercially available DGA resin. This resin shows an affinity for Am, Pu, U, and Th and is also exhibiting signs of a possible synergistic effects in the presence of iron.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic Surface Tension and Diffusivity Measurements of NG-CSSX Next Generation Solvent

Since 2008, the Savannah River Site has processed more than four million gallons of radioactive supernatant. To continue compliance with downstream processes, MCU is switching to the improved solvent called Next Generation Solvent (NG-CSSX). The new solvent formulation promises higher cesium removal efficiency and laboratory testing suggests the potential of higher processing rates. Similarly, laboratory testing demonstrated improvements in separation of the solvent from the effluent aqueous streams. To complete implementation at MCU, additional work was needed to develop methods that can measure physical properties relevant to the performance of the new solvent. This work measures two relevant physical properties: static interfacial tension and diffusvity. Both properties play a relevant role in mixing and separating immiscible liquids. This work evaluated the impact of changes in composition or aqueous phase on these physical properties to gauge the sensitivity of the system to the losses of chemical components.

Fondeur, F. F.↗

Digital-computer normal shock position and restart control of a Mach 2.5 axisymmetric mixed-compression inlet

Digital computer control of a mixed-compression inlet is discussed. The inlet was terminated with a choked orifice at the compressor face station to dynamically simulate a turbojet engine. Inlet diffuser exit airflow disturbances were used. A digital version of a previously tested analog control system was used for both normal shock and restart control. Digital computer algorithms were derived using z-transform and finite difference methods. Using a sample rate of 1000 samples per second, the digital normal shock and restart controls essentially duplicated the inlet analog computer control results. At a sample rate of 100 samples per second, the control system performed adequately but was less stable.

Neiner, G. H.↗

Control systems synthesis for a large flexible space antenna

The problem of control systems synthesis is considered for controlling the rigid-body attitude and elastic motion of a large deployable space-based antenna. Two methods for control systems synthesis are considered. The first method utilizes the stability and robustness properties of the controller consisting of torque actuators and collocated attitude and rate sensors. The second method is based on the linear-quadratic-Gaussian (LQG) control theory. A combination of the two methods, which results in a two-level hierarchical control system, is also briefly discussed. The performance of the controllers is analyzed by computing the variances of pointing errors, feed misalignment errors and surface contour errors in the presence of sensor and actuator noise.

Joshi, S. M.↗

Structural Tailoring of SSME Blades (vanes)

The engine blade design optimization program STAEBL (Structural Tailoring of Engine Blades) is available at the NASA Lewis computer facility. The analysis capabilities of this program were extended to typical loading conditions for SSME turbopump blades including thermal and pressure loading. Input files for representative SSME blade designs were developed and sample optimization studies for these blades completed. The structural tailoring program combines a general optimization package and a finite element blade analysis package. The analysis package's capabilities include natural frequency, maximum stress, and forced response computation, and fatigue life and flutter analysis. Optimization is performed using the feasible directions method. The current design is modified by perturbing the design variables so that the design constraints are satisfied while the objective function, such as blade weight, is reduced at the maximum rate. The program's geometric design variables include blade thickness distribution, thickness to chord ratios, and root chord.

Rubinstein, R.↗

Development of a coded 16-ary CPFSK coherent demodulator

Theory and hardware are described for a proof-of-concept 16-ary continuous phase frequency shift keying (16-CPFSK) digital modem. The 16 frequencies are spaced every 1/16th baud rate for 2 bits/sec/Hz operation. Overall rate 3/4 convolutional coding is incorporated. The demodulator differs significantly from typical quadrature phase detector approaches in that phase is coherently measured by processing the baseband output of a frequency discriminator. Baud rate phase samples from the baseband processor are decoded to yield the original data stream. The method of encoding onto the 16-ary phase nodes, together with convolutional coding gain, results in near quad PSK (QPSK) performance. The modulated signal is of constant envelope; thus the power amplifier can be saturated for peak performance. The spectrum is inherently bandlimited and requires no RF filter.

Clarke, Ken↗

Atomic oxygen undercutting of defects on SiO2 protected polyimide solar array blankets

Low Earth Orbital (LEO) atomic oxygen can oxidize SiO2-protected polyimide kapton solar array blanket material which is not totally protected as a result of pinholes or scratches in the SiO2 coatings. The probability of atomic oxygen reaction upon initial impact is low, thus inviting oxidation by secondary impacts. The secondary impacts can produce atomic oxygen undercutting which may lead to coating mechanical failure and ever increasing mass loss rates of kapton. Comparison of undercutting effects in isotropic plasma asher and directed beam tests are reported. These experimental results are compared with computational undercutting profiles based on Monte Carlo methods and their implication on LEO performance of protected polymers.

Banks, Bruce A.↗

The temperature dependent variation of bulk and surface composition of In(x)Ga(1-x)As on GaAs grown by chemical beam epitaxy studied by RHEED, X-ray diffraction and XPS

The paper investigates the bulk as well as near-surface composition of In(x)Ga(1-x)As epilayers on GaAs grown by chemical beam epitaxy (CBE) as a function of triethylindium flow rate and substrate temperature by reflection high energy electron diffraction (RHEED), X-ray diffraction, and XPS. To clarify whether the bulk stoichiometry of CBE-grown ternaries can be extracted from the growth rate change as determined by the change in the period of RHEED oscillations from binary to ternary compound growth, a systematic study of growth rate change as a function of ternary bulk composition determined by X-ray diffraction was performed at various temperatures. It is shown that for low growth temperatures there is a linear relationship between the two methods of determination, whereas no correlation is found for higher growth temperatures, in contrast to the MBE case where the two methods of determination yield identical results. In the near surface region the epilayer composition is determined in situ by XPS.

Hansen, H. S.↗

Effects of through-the-thickness stitching on impact and interlaminar fracture properties of textile graphite/epoxy laminates

This study investigated the effects of through-the-thickness stitching on impact damage resistance, impact damage tolerance, and mode I and mode II fracture toughness of textile graphite/epoxy laminates. Uniweave resin-transfer-molded 48 ply graphite/epoxy (AS4/3501-6) laminates were stitched with Kevlar and glass yarns of different linear densities and stitch spacings. Delaminations were implanted during processing to simulate impact damage. Sublaminate buckling tests were performed to determine the effects of stitching on the compressive strength. The results showed outstanding improvements of up to 400 percent in the compression strength over the unstitched laminates. In impact and static indentation tests the onset of damage occurred at the same level, but the extent of damage was less in stitched laminates. Mode I fracture toughness of 24 ply Uniweave unidirectional (AS4/3501-6) stitched laminates was measured by conducting double-cantilever-beam tests. The critical strain energy release rate (G(sub Ic)) was found to be up to 30 times higher than the unstitched laminates. Mode II fracture toughness of the Uniweave laminates was measured by performing end-notched-flexure tests. Two new methods to compute the apparent G(sub IIc) are presented. The apparent G(sub IIc) was found to be at least 5-15 times higher for the stitched laminates.

Sharma, Suresh K.↗

A Parametric Study of a Plug Nozzle, Using the Liquid Propellant Program (LPP) Code

The Liquid Propellant Program (LPP) computer code is a super-set of the industry standard Two Dimensional Kinetics (TDK) computer code. The TDK code uses a two dimensional method of characteristics solution with fully coupled finite rate kinetics for axially symmetric nozzles. The chemical reactions are modeled with a generalized reaction package that include three dimensional body efficiencies and four reaction rate forms. The code performs optional solutions for frozen or equilibrium flow. TDK evaluates discrete shocks, both attached or induced. The Transonic module models variable mixture ratio profiles from the combustion chamber injector. The Mass Addition Boundary Layer module (MABL) calculates the boundary parameters with the same chemistry options, and includes transpiration or tangential slot injection of gas at the wall. The LPP upgrades include: planar nozzle, scarfed nozzles, plug nozzles, and scramjet nozzle configurations. The code evaluates both upper and lower wall flow simulation, and includes the interaction with the external flow. The MABL module evaluates equilibrium radiation heat transfer for both upper and lower walls. In addition, LPP code models combustion effects due to injector inefficiencies with the Spray Combustion Analysis Program (SCAP) module. The LPP package provides extensive post plotting capabilities for flow visualization. The LPP is sufficiently fast and robust to provide performance predictions for extensive parametric studies and sufficiently accurate to provide flow field and performance solutions for detailed studies.

Dunn, Stuart S.↗

Protein Crystal Growth With the Aid of Microfluidics

Protein crystallography is one of three well-known methods to obtain the structure of proteins. A major rate limiting step in protein crystallography is protein crystal nucleation and growth, which is still largely a process conducted by trial-and-error methods. Many attempts have been made to improve protein crystal growth by performing growth in microgravity. Although the use of microgravity appears to improve crystal quality in some attempts, this method has been inefficient because several reasons: we lack a fundamental understanding of macromolecular crystal growth in general and of the influence of microgravity in particular, we have to start with crystal growth conditions in microgravity based on conditions on the ground and finally the hardware does not allow for experimental iteration without reloading samples on the ground. To partially accommodate the disadvantages of the current hardware, we have used microfluidic technology (Lab-on-a-Chip devices) to design the concept of a more efficient crystallization device, suitable for use on the International Space Station and in high-throughput applications on the ground. The concept and properties of microfluidics, the application design process, and the advances in protein crystal growth hardware will be discussed in this presentation. Some examples of proteins crystallized in the new hardware will be discussed, including the differences between conventional crystallization versus crystallization in microfluidics.

vanderWoerd, Mark↗

DSMC Simulations of Hypersonic Flows and Comparison With Experiments

This paper presents computational results obtained with the direct simulation Monte Carlo (DSMC) method for several biconic test cases in which shock interactions and flow separation-reattachment are key features of the flow. Recent ground-based experiments have been performed for several biconic configurations, and surface heating rate and pressure measurements have been proposed for code validation studies. The present focus is to expand on the current validating activities for a relatively new DSMC code called DS2V that Bird (second author) has developed. Comparisons with experiments and other computations help clarify the agreement currently being achieved between computations and experiments and to identify the range of measurement variability of the proposed validation data when benchmarked with respect to the current computations. For the test cases with significant vibrational nonequilibrium, the effect of the vibrational energy surface accommodation on heating and other quantities is demonstrated.

Moss, James N.↗

MIT Participation in the Data Analysis of the XRS and XIS Instruments on the Astro-E2 Mission

Since the inception of this grant six weeks ago, we have completed the initial activation of the Suzaku X-ray Imaging Spectrometer (XIS) (on 13 August) and we have supported initial calibration observations. The instrument is performing very well in all respects. We have characterized the spectral resolution and effective area of each XIS sensor. We are especially excited about the scientific opportunities provided by the XIS'S back- illuminated sensor, which exhibits spectral resolution in the sub-keV band unmatched by any X-ray CCD currently in orbit. As specified in our proposal, we have established a web site (http://space.mit.edu/XIS) on which we maintain an up-to-date summary of instrument performance characteristics. Gain, spectral resolution and system noise, as well as residual background rates, are currently available on this site. Although the particle background level is low compared with Chandra and XMM, we are currently evaluating methods to reduce it still further. Techniques under study include use of 5x5 mode information and alternative grade selection methods. Although the primary responsibility for development of instrument response functions rests with our Japanese colleagues, we are incorporating our latest measurements of spectral resolution into some temporary response functions which we hope to make available to the Suzaku General Observer Facility and the Science Working Group(SWG). We are also preparing proposals for use of SWG observing time.

Bautz, Mark↗

Calculating Soil Wetness, Evapotranspiration and Carbon Cycle Processes Over Large Grid Areas Using a New Scaling Technique

Soil wetness typically shows great spatial variability over the length scales of general circulation model (GCM) grid areas (approx 100 km ), and the functions relating evapotranspiration and photosynthetic rate to local-scale (approx 1 m) soil wetness are highly non-linear. Soil respiration is also highly dependent on very small-scale variations in soil wetness. We therefore expect significant inaccuracies whenever we insert a single grid area-average soil wetness value into a function to calculate any of these rates for the grid area. For the particular case of evapotranspiration., this method - use of a grid-averaged soil wetness value - can also provoke severe oscillations in the evapotranspiration rate and soil wetness under some conditions. A method is presented whereby the probability distribution timction(pdf) for soil wetness within a grid area is represented by binning. and numerical integration of the binned pdf is performed to provide a spatially-integrated wetness stress term for the whole grid area, which then permits calculation of grid area fluxes in a single operation. The method is very accurate when 10 or more bins are used, can deal realistically with spatially variable precipitation, conserves moisture exactly and allows for precise modification of the soil wetness pdf after every time step. The method could also be applied to other ecological problems where small-scale processes must be area-integrated, or upscaled, to estimate fluxes over large areas, for example in treatments of the terrestrial carbon budget or trace gas generation.

Sellers, Piers↗