PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hotor combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR =2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (along the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part 1 report. The rest of the data will be published in a future report, Part 2, along with planned CFD predictions of the complex cooling film flow.The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Mark P Wernet↗

1- by 1-Foot Supersonic Wind Tunnel Sidewall Flowfield Compression Plate Study

A method for locally increasing the dynamic pressure in the test section of a supersonic wind tunnel is investigated from a theoretical, computational and experimental perspective, culminating in a reduced-scale, proof-of-concept test at Mach 3.44. Symmetric, variable-angle compression plates along the test section sidewalls generate oblique shockwaves to elevate the test section dynamic pressure (q). The experimental effort utilizes boundary-layer pitot rakes to sample the incoming flow near the floor, pitot and static rakes to measure the high-q core flow and numerous surface taps to map out the static pressure distribution along the floor, ceiling and sidewalls. A reliable and robust starting procedure is developed to establish supersonic flow in the test section and behind the compression plates. A characterization of the incoming floor boundary layer reveals previously documented features (such as a bulge toward the centerline) and an unexpected (and as-yet-unexplained) thickening of the boundary layer with increasing Reynolds number around total pressures of 40–60 psia. The high-q core flow is characterized for eight compression plate angles (4.0–8.0°), eight tunnel total pressures (20–139 psia) and three axial stations (24.95–27.35 inches). The peak dynamic pressure rise exceeds expectations. At conditions relevant to full-scale testing (6.0° and 139 psia), the dynamic pressure increases by a factor of 1.73, the Mach number becomes 2.85 and the total pressure drops imperceptibly. Basic distortion metrics show transverse non-uniformity of less than 5 %. Limited spatial resolution in the static rake measurements warrants additional, higher fidelity testing or computational analysis. Surface-mounted, fast-response instrumentation suggests minimal unsteadiness in the flow, less than a few percent of the mean (comparable to the sensor accuracy).

Wind tunnel testing, test techniques/methods, dyna↗

Multiphysics Computational Analysis of a Perforated Plate Cooling Flow

A multiphysics analysis of a film cooling flow was conducted using a computational fluid dynamics (CFD) solver in conjunction with a conjugate heat transfer (CHT) solver. The film cooling problem consisted of a square nozzle producing a heated subsonic jet over a perforated plate with three sections of 45 cooling holes each. Results from the multiphysics analysis were compared to a CFD-only approach and experimental results. Reynolds-averaged Navier-Stokes (RANS) computations were employed first, with and without the CHT solver. The multiphysics approach provided much closer agreement with experimentally measured plate temperatures than the CFD-only approach. Comparisons of computed velocities and temperatures were also made with experimental data. Hybrid RANS-large eddy simulation calculations employing the Delayed Detached Eddy Simulation (DDES) approach were also conducted within the multiphysics framework. The DDES approach was unable to resolve turbulent structures in the near wall regions. Hence, the RANS part of the DDES model was used in near wall regions, and produced surface temperatures along with velocity and temperature profiles close to the wall that were very similar to the RANS results. The DDES approach did resolve structures in the outer portion of the boundary layer especially near the end of the plate where the boundary layer was thicker. The key result was the improved surface temperatures produced by the multiphysics approach employing CHT over the fluid-only approach.

Computational Fluid Dynamics↗

Computational Study of Low-Speed Boundary-Layer Laminar-Turbulent Transition over a 30º Swept Plate in a Channel

Reliable boundary-layer laminar-turbulent transition predictions are critical for the design of aircraft that use natural or controlled laminar flow to achieve low drag and better fuel efficiency. During cruise flight through low turbulence, the three-dimensional boundary layer over swept surfaces can transition prematurely due to stationary crossflow instabilities induced by surface roughness. Parabolized stability equations analyses have been successfully used to explain the different phases of the transition process under well controlled perturbations such as steps or discrete roughness elements. However, methodologies are still lacking to model the boundary layer receptivity to distributed random roughness, and the following non-linear instability stages leading to transition. For engineering applications, several semi-empirical methods based on linear amplification factors or local helicity have found growing adoption, but their reliability is limited by their level of simplification and the sparsity of data they are based on. To address this gap, a new study of the effect of distributed random surface roughness on crossflow transition was started, using a 30◦ swept plate as a test vehicle. The plate, which is mounted in the 2 Foot × 3 Foot Low-Speed Boundary-Layer Channel at the NASA Langley Research Center, has been tested with micro-scale roughness of varied geometry near the leading edge. In order to analyze the flow in the test section and prepare Direct Numerical Simulations with resolved roughness, Reynolds-Averaged Navier-Stokes (RANS) simulations of the flow over the plate installed in the wind tunnel test section were performed using the Langtry-Menter transition model with stationary crossflow extension. This paper presents the results of these simulations, with comparison to the experiment.

ARMD↗

Parallel-Plate Capacitor TiN KIDs for Infrared Astronomy

The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will characterize dust in the vicinity of high-mass stars. It requires detectors with NEPs from 2x10 -16 W Hz -1/2 to 6x10 -17 W Hz -1/2 from 25-250 microns, respectively. The mission’s sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor deposited on a Silicon (Si) substrate. The parallel plate capacitor geometry allows for reduction of the pixel spacing. We present the optical performance of a prototype BEGINS KID array at 25 microns when coupled to Fresnel zone plate lenses. We present sensitivity, optical efficiency and quasiparticle lifetime measurements taken in a cryogenic test bed with a cryogenic blackbody.

Joanna Perido↗

Short-Transverse Tensile Fracture Behavior of Thick AA2219 Plate - Effects of Theta (Al2Cu) Particle Size and Distribution

An investigation was conducted to obtain a better understanding on the microstructural characteristics of 5-inch-thick AA2219-T87 plate material and the mechanism that led to the unexpected low ductility in the short-transverse (ST) orientation. Materials characterization techniques were utilized to observe the microstructure of fractured tensile specimens and remnant plate material. The mechanism and cause of low ST ductility in the thick plate material is presented and discussed in this report.

Short-Transverse Orientation↗

Disruption Analysis and Response Implicattions of Passive Plates for the NSTX Upgrade

The NSTX upgrade project requires analysis qualifications of existing vacuum vessel and passive stabilizing plates for increased plasma performance. Vertical stability is critically dependent on the passive conducting structure that surrounds the plasma. In this paper, the passive conducting structure is analyzed for the upgrade condition during plasma disruption to ensure the level of stress in the stabilizing plates and the fastener is within its design limits. The counter-bore of the passive plates for bolting is evaluated in details and counter-bore bushing is redesigned to prevent shear failure during disruptions as a result of high pulling and pushing forces, particularly for support at the corner bolts

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fuel cell repeater unit including frame and separator plate

An example fuel cell repeater includes a separator plate and a frame establishing at least a portion of a flow path that is operative to communicate fuel to or from at least one fuel cell held by the frame relative to the separator plate. The flow path has a perimeter and any fuel within the perimeter flow across the at least one fuel cell in a first direction. The separator plate, the frame, or both establish at least one conduit positioned outside the flow path perimeter. The conduit is outside of the flow path perimeter and is configured to direct flow in a second, different direction. The conduit is fluidly coupled with the flow path.

42 ENGINEERING↗

Laser Shockwave Technique For Characterization Of Nuclear Fuel Plate Interfaces

The US National Nuclear Security Agency is tasked with minimizing the worldwide use of high-enriched uranium. One aspect of that effort is the conversion of research reactors to monolithic fuel plates of low-enriched uranium. The manufacturing process includes hot isostatic press bonding of an aluminum cladding to the fuel foil. The Laser Shockwave Technique (LST) is here evaluated for characterizing the interface strength of fuel plates using depleted Uranium/Mo foils. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves and is therefore well adapted to the quality assurance of this process. Preliminary results show a clear signature of well-bonded and debonded interfaces and the method is able to classify/rank the bond strength of fuel plates prepared under different HIP conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Shutdown-induced tensile stress in monolithic miniplates as a possible cause of plate pillowing at very high burnup

Post-irradiation examination of Reduced Enrichment for Research and Test Reactors (RERTR)-12 miniplates showed that in-reactor pillowing occurred in at least 4 plates, rendering performance of these plates unacceptable. To address in-reactor failures, efforts are underway to define the mechanisms responsible for in-reactor pillowing, and to suggest improvements to the fuel plate design and operational conditions. To achieve these objectives, the mechanical response of monolithic fuel to fission and thermally-induced stresses was modeled using a commercial finite element analysis code. Calculations of stresses and deformations in monolithic miniplates during irradiation and after the shutdown revealed that the tensile stress generated in the fuel increased from 2 MPa to 100 MPa at shutdown. The increase in tensile stress at shutdown possibly explains in-reactor pillowing of several RERTR-12 miniplates irradiated to the peak local burnup of up to 1.11x1022 fissions/cm3 . This paper presents the modeling approach and calculation results, and compares results with post-irradiation examinations and mechanical testing of irradiated fuel. The implications for the safe use of the monolithic fuel in research reactors are discussed, including the influence of fuel burnup and power on the magnitude of the shutdown-induced tensile stress.

rertr↗

Testing Single Phase IGBT H-Bridge Switch Plates for the High Voltage Converter Modulator at the Spallation Neutron Source

Three IGBT H-bridge switching networks are used in each High Voltage Converter Modulator (HVCM) system at the Spallation Neutron Source (SNS) to generate drive currents to three boost transformer primaries switching between positive and negative bus voltages at 20 kHz. Every switch plate assembly is tested before installing it into an operational HVCM. A Single Phase Test Stand has been built for this purpose, and it is used for adjustment, measurement and testing of different configurations of switch plates. This paper will present a description of the Test Stand configuration and discuss the results of testing switch plates with two different types of IGBT gate drivers currently in use on the HVCM systems. Comparison of timing characteristics of the original and new drivers and the resulting performance reinforces the necessity to replace the original H-bridge network drivers with the upgraded units.

Gate Driver↗

Effusion plate using additive manufacturing methods

Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

33 ADVANCED PROPULSION SYSTEMS↗

Systems and methods for forming microchannel plate (MCP) photodetector assemblies

A MCP photodetector assembly includes an anode plate including a plurality of electrical traces positioned thereon, a plurality of MCPs and a plurality of grid spacers. The MCPs are positioned between the grid spacers. The grid spacers have a grid spacer shape defining at least one aperture. A plurality of shims are positioned between the grid spacers and the MCPs so as to form a stack positioned on the anode plate. Each of the plurality of shims have a shim shape which is the same as the grid spacer shape such that each of the plurality of shims and each of the plurality of grid spacers overlap so as to define at least one MCP aperture. At least a portion of the plurality of MCPs are positioned within the MCP aperture. The shims are structured to electrically couple the MCPs to the anode plate.

47 OTHER INSTRUMENTATION↗

Dielectric-plate-implanted Higher Order Mode (HOM) Waveguide for High Intensity Multi-beam Device Application

A mode-selective oversized RF-beam channel has been investigated for high intensity multi-beam devices. Implanting the equi-spaced dielectric plates at the transverse positions where longitudinal electric fields of a HOM are minimal in the mic ro-metallic structure strongly suppresses all lower energy modes and other wakefield modes. The dielectric lattice captures only a single HOM of the wavelengths that correspond to the plate spacing. Electromagnetic simulations have shown that the lower en ergy modes, TE10 and TE20 modes, are suppressed down to < ~ -60 dB by two plate loads, while TE310-mode prominently propagates through the 2 mm long waveguide only with 4 dB (= -2dB/mm) at 1 THz. The numerical calculation indicated that the TE30 mode has ~ a few times higher Q than the lower energy modes. The strong single mode selectivity has been extensively looked into with a more highly overmoded structure. Feasibility analysis of the HOM structure for multi-beam device application is under investiga tion. Particle-in-cell (PIC) simulation has shown coherent beam bunching and energy gain from THz driving signal.

43 PARTICLE ACCELERATORS↗

Extended Plate Wall System Expands Adoption of High-R Envelope Solutions

For decades, the residential building industry has worked to expand opportunities to increase the thermal resistance of walls. Multiple high-R wall construction methods have been developed, yet market adoption remains low because of perceived complexity and cost. One appealing solution is an extended plate wall system (EPW). Framing for top and bottom plates is one nominal dimension larger than for studs, which provides space for a 2-inch layer of foam plastic insulative sheathing (FPIS). Wood structural sheathing (OSB or plywood) is then installed on the exterior, fastened directly to the plates and nailed through the foam to the studs. In contrast to the conventional method of installing FPIS as a fully exterior layer, the EPW greatly simplifies air sealing, installation and detailing of windows and doors, an application of a weather resistive barrier, and attachment of cladding.

Building America↗

Variable stiffness flyer plate for penetration device

A penetration device including a casing, a propellant positioned in the casing, and a flyer plate. The flyer plate is coupled to the casing and adjacent to the propellant. The flyer plate includes a center portion having a substantially constant first thickness and includes a peripheral portion around the center portion and defining an edge. The peripheral portion includes one or more recesses in a first surface of the peripheral portion.

Muha, Nicholas B.↗

Developing a New Criticality Safety Hands-On Training Utilizing ZPPR Plates

Nuclear criticality safety is an extremely important part of the work at Los Alamos National Laboratory (LANL). As part of the work LANL performs to continue to keep criticality safety a top priority, LANL has developed and regularly teaches nuclear criticality safety training classes for both the United States Department of Energy Nuclear Criticality Safety Program as well as internal trainings for LANL employees. A portion of the training classes is comprised of hands-on demonstrations, where students get the opportunity to handle special nuclear material at the National Criticality Experiments Research Center (NCERC). One hands-on demonstration uses the “Class foils,” thin HEU foils which are stacked with lucite moderator plates. A hand-stack is performed until the multiplication reaches the “three-quarters rule,” where the demonstration is continued remotely on a vertical lift assembly up until the system is critical. This hands-on demonstration eventually achieves a critical configuration and follows the ANS-1 guidelines on an approach to critical. Another hands-on demonstration involves handling clad plutonium and neptunium spheres, and follows procedures using criticality safety evaluations to ensure that the hands-on demonstrations remain subcritical.This hands-on demonstration also involves the use of polyethylene shells around the plutonium sphere to demonstrate how additional reflector increases the criticality of a system. This paper is focused on developing a new hands-on demonstration using Zero Power Physics Reactor (ZPPR) plates. This new hands-on demonstration will follow the ANS-8 standards as it is not desired to achieve criticality with the ZPPR plates during the hands-on demonstration. A hands-on demonstration using multiple plutonium parts will likely be more applicable to personnel who handle plutonium on a daily basis, such as LANL glovebox operators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration technique of wall shear stress sensors using oscillating plate

Disclosed are a system and methods for calibrating wall shear stress sensors. The system includes an oscillating plate coupled to an actuator and mounted on a rolling elements, and one or more sensors coupled to a height adjusting device. The system can further comprise a height control rod coupled to a height control base and a sensor holder configured to house the one or more sensors and supported on a connector, the connector configured to be rotatably disposed about the height control rod. The system can be calibrated by causing the actuator to oscillate the oscillating plate at a frequency, sensing, using the one or more sensors, shear stress at a wall, the shear stress at the wall being associated with a velocity field, and determining a theoretical wall shear stress based on fluid properties, the frequency, and the height of the one or more sensors above the oscillating plate.