Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Thermoacoustic Thermometry for Nuclear Reactor Monitoring

On Friday, March 11, 2011, at 2:46pm (Japan Standard Trme), the Tohoku region on the east coast of northern Japan experi­enced what would become known as the largest earthquake in the country's history at magnitude 9.0 on the Richter scale. The Fukushima Daiichi nuclear power plant suffered exten­sive and irreversible damage. Six operating units were at the site, each with a boiling water reactor. When the earthquake struck, three of the six reactors were operating and the others were in a periodic inspection outage phase. In one reactor, all of the fuel had been relocated to a spent fuel pool in the reactor building. The seismic acceleration caused by the earthquake brought the three operating units to an automatic shutdown. Since there was damage to the power transmission lines, the emergency diesel generators (EDG) were automat­ically started to ensure continued cooling of the reactors and spent fuel pools. The situation was under control until the tsunami hit about forty-five minutes later with a maximum wave height of approximately 15 meters, which was three times taller than the sea wall of 5m. The influx of water submerged the EDGs, the electrical switchgear, and dc batteries, resulting in the total loss of power to five of the six reactors. The flooding also resulted in the loss of instrumentation that would have other­ wise been used to monitor and control the emergency. The ugly aftermath included high radiation exposure to operators at the nuclear power plants and early contamina­tion of food supplies and water within several restricted areas in Japan, where high radiation levels have rendered them un­safe for human habitation. While the rest of the story will remain a tragic history, it is this part of the series of unfortunate events that has inspired our research. It has indubitably highlighted the need for a novel sensor and instrumentation system that can withstand similar or worse conditions to avoid future catastrophe and assume damage prevention as quickly as possible. This is the question which we are attempting to answer: Is it possible to implement a self-powered sensor that could transmit data independently of electronic networks while taking advantage of the harsh operating environment of the nuclear reactor?

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2011 Annual Report [WESTERN AREA POWER ADMINISTRATION]

Western’s achievements for 2011 are reported and include: Experienced a banner water year – meaning more hydropower delivered; Changed energy scheduling— to better support intermittent renewable resources; Maintained reliability— ensuring maximum use of the grid by reducing the frequency and duration of planned and unplanned outages; Connected communities— providing customers energy products and related services at cost-based rates; Managed transmission projects.

13 HYDRO ENERGY↗

PMU Data Integrity Evaluation through Analytics on a Virtual Test-Bed

Power systems are rapidly becoming populated by phasor measurement units (PMUs) in ever increasing numbers. PMUs are critical components of today s energy management systems, designed to enable near real-time wide area monitoring and control of the electric power system. They are able to measure highly accurate bus voltage phasors as well as branch current phasors incident to the buses at which PMUs are equipped. Synchrophasor data is used for applications varying from state estimation, islanding control, identifying outages, voltage stability detection and correction, disturbance recording, and others. However, PMU-measured readings may suffer from errors due to meter biases or drifts, incorrect configurations, or even cyber-attacks. Furthermore, the testing of early PMUs showed a large disparity between the reported values from PMUs provided by different manufacturers, particularly when frequency was off-nominal, during dynamic events, and when harmonic/inter-harmonic content was present. Detection and identification of PMU gross measurement errors are thus crucial in maintaining highly accurate phasor readings throughout the system. In this paper, we present our work in conducting analytics to determine the trustworthiness and worth of the PMU readings collected across an electric network system. By implementing the IEEE 118 bus test case on a virtual test bed (VTB) , we are able to emulate PMU readings (bus voltage and branch current phasors in addition to bus frequencies) under normal and abnormal conditions using (virtual) PMU sensors deployed across major substations in the network. We emulate a variety of failures such as bus, line, transformer, generator, and/or load failures. Data analytics on the voltage phase angles and frequencies collected from the PMUs show that specious (or compromised) PMU device(s) can be identified through abnormal behaviour by comparing the trend of its frequency and phase angle reading with the ensemble of all other PMU readings in the network. If the reading trend of a particular PMU deviates from the weighted average of the reading trends of other PMUs at nearby substations, then it is likely that the PMU is malfunctioning. We assign a weight to each PMU denoting how electric-topology-wise close it is from where the PMU under consideration is located. The closer a PMU is, the higher the weight it has. To compute the closeness between two nodes in the power network, we employ a form of the resistance distance metric. It computes the electrical distance by taking into consideration the underlying topology as well as the physical laws that govern the electrical connections or flows between the network components. The detection accuracy of erroneous PMUs should be improved by employing this metric. We present results to validate the proposed approach. We also discuss the effectiveness of using an end-to-end VTB approach that allows us to investigate different types of failures and their responses as seen by the ensemble of PMUs. The collected data on certain types of events may be amenable to certain types of analysis (e.g., alerting for sudden changes can be done on a small window of data) and hence determine the data analytics architectures is required to evaluate the streaming PMU data.

and data analytics architecture.↗

Protection requirements for the resistance of meteorite penetration of interplanetary spacecraft systems

The Plutonium Recycle Test Reactor primary coolant pumps use face type mechanical shaft seals and incorporate a large flywheel for emergency ilow during power outages. The test and development work preceding and during initial PRTR operation revealed several major problems. These problems and their solutions are discussed. Mechanical seal life was extended from original rapid failures in a few hours to periods of several thousand hours. (auth)

REACTOR TECHNOLOGY↗

High-Performance Computing for Real-Time Grid Analysis and Operation

Power grids worldwide are undergoing an unprecedented transition as a result of grid evolution meeting information revolution. The grid evolution is largely driven by the desire for green energy. Emerging grid technologies such as renewable generation, smart loads, plug-in hybrid vehicles, and distributed generation provide opportunities to generate energy from green sources and to manage energy use for better system efficiency. With utility companies actively deploying these technologies, a high level of penetration of these new technologies is expected in the next 5-10 years, bringing in a level of intermittency, uncertainties, and complexity that the grid did not see nor design for. On the other hand, the information infrastructure in the power grid is being revolutionized with large-scale deployment of sensors and meters in both the transmission and distribution networks. The future grid will have two-way flows of both electrons and information. The challenge is how to take advantage of the information revolution: pull the large amount of data in, process it in real time, and put information out to manage grid evolution. Without addressing this challenge, the opportunities in grid evolution will remain unfulfilled. This transition poses grand challenges in grid modeling, simulation, and information presentation. The computational complexity of underlying power grid modeling and simulation will significantly increase in the next decade due to an increased model size and a decreased time window allowed to compute model solutions. High-performance computing is essential to enable this transition. The essential technical barrier is to vastly increase the computational speed so operation response time can be reduced from minutes to seconds and sub-seconds. The speed at which key functions such as state estimation and contingency analysis are conducted (typically every 3-5 minutes) needs to be dramatically increased so that the analysis of contingencies is both comprehensive and real time. An even bigger challenge is how to incorporate dynamic information into real-time grid operation. Today’s online grid operation is based on a static grid model and can only provide a static snapshot of current system operation status, while dynamic analysis is conducted offline because of low computational efficiency. The offline analysis uses a worst-case scenario to determine transmission limits, resulting in under-utilization of grid assets. This conservative approach does not necessarily lead to reliability. Many times, actual power grid scenarios are not studied, and they will push the grid over the edge and resulting in outages and blackouts. This chapter addresses the HPC needs in power grid analysis and operations. Example applications such as state estimation and contingency analysis are given to demonstrate the value of HPC in power grid applications. Future research directions are suggested for high performance computing applications in power grids to improve the transparency, efficiency, and reliability of power grids.

Contingency Analysis↗

Design of Refractory Linings for Balanced Energy Efficiency, Uptime, and Capacity in Lime Kilns

The rotary kilns used by the pulp and paper industry to regenerate lime in the Kraft process are very energy intensive. Throughout the 90 s, in response to increasing fuel prices, the industry used back up insulation in conjunction with the high alumina brick used to line the burning zones of their kilns. While this improved energy efficiency, the practice of installing insulating brick behind the working lining increased the inner wall temperatures. In the worst case, due to the increased temperatures, rapid brick failures occurred causing unscheduled outages and expensive repairs. Despite these issues, for the most part, the industry continued to use insulating refractory linings in that the energy savings were large enough to offset any increase in the cost of maintaining the refractory lining. Due to the dramatic decline in the price of natural gas in some areas combined with mounting pressures to increasing production of existing assets, over the last decade, many mills are focusing more on increasing the uptime of their kilns as opposed to energy savings. To this end, a growing number of mills are using basic (magnesia based) brick instead of high alumina brick to line the burning zone of the kiln since the lime mud does not react with these bricks at the operating temperatures of the burning zone of the kiln. In the extreme case, a few mills have chosen to install basic brick in the front end of the kiln running a length equivalent to 10 diameters. While the use of basic brick can increase the uptime of the kiln and reduce the cost to maintain the refractory lining, it does dramatically increase the heat losses resulting from the increased operating temperatures of the shell. Also, over long periods of time operating at these high temperatures, damage can occur in the shell. There are tradeoffs between energy efficiency, capacity and uptime. When fuel prices are very high, it makes sense to insulate the lining. When fuel prices are lower, trading some thermal efficiency for increased uptime and capacity seems reasonable. This paper considers a number of refractory linings in an effort to develop optimized operating strategies that balance these factors. In addition to considering a range of refractory materials, the paper examines other factors such as the chain area, discharge dams and other operating variables that impact the service life of the refractory lining. The paper provides recommendations that will help mill personnel develop a strategy to select a refractory lining that is optimized for their specific situation.

Computational Modeling↗

Incorporating Forecast Uncertainty in Utility Control Center

Uncertainties in forecasting the output of intermittent resources such as wind and solar generation, as well as system loads are not adequately reflected in existing industry-grade tools used for transmission system management, generation commitment, dispatch and market operation. There are other sources of uncertainty such as uninstructed deviations of conventional generators from their dispatch set points, generator forced outages and failures to start up, load drops, losses of major transmission facilities and frequency variation. These uncertainties can cause deviations from the system balance, which sometimes require inefficient and costly last minute solutions in the near real-time timeframe. This Chapter considers sources of uncertainty and variability, overall system uncertainty model, a possible plan for transition from deterministic to probabilistic methods in planning and operations, and two examples of uncertainty-based fools for grid operations.This chapter is based on work conducted at the Pacific Northwest National Laboratory (PNNL)

wind generation, solar generation, Energy managmen↗

Reliability and Geographic Trends of 50,000 Photovoltaic Systems in the USA: Preprint

This paper presents performance and reliability data from nearly 50,000 photovoltaic (PV) systems totaling 1.7 gigawatts installed capacity in the USA from 2009 to 2012 and their geographic trends. About 90% of the normal systems and about 85% of all systems, including systems with known issues, performed to within 10% or better of expected performance. Although considerable uncertainty may exist due to the nature of the data, hotter climates appear to exhibit some degradation not seen in the more moderate climates. Special causes of underperformance and their impacts are delineated by reliability category. Hardware-related issues are dominated by inverter problems (totaling less than 0.5%) and underperforming modules (totaling less than 0.1%). Furthermore, many reliability categories show a significant decrease in occurrence from year 1 to subsequent years, emphasizing the need for higher-quality installations but also the need for improved standards development. The probability of PV system damage because of hail is below 0.05%. Singular weather events can have a significant impact such as a single lightning strike to a transformer or the impact of a hurricane. However, grid outages are more likely to have a significant impact than PV system damage when extreme weather events occur.

14 SOLAR ENERGY↗

Understanding the Effect of Baseline Modeling Implementation Choices on Analysis of Demand Response Performance

Accurate evaluation of the performance of buildings participating in Demand Response (DR) programs is critical to the adoption and improvement of these programs. Typically, we calculate load sheds during DR events by comparing observed electric demand against counterfactual predictions made using statistical baseline models. Many baseline models exist and these models can produce different shed calculations. Moreover, modelers implementing the same baseline model can make different modeling implementation choices, which may affect shed estimates. In this work, using real data, we analyze the effect of different modeling implementation choices on shed predictions. We focused on five issues: weather data source, resolution of data, methods for determining when buildings are occupied, methods for aligning building data with temperature data, and methods for power outage filtering. Results indicate sensitivity to the weather data source and data filtration methods as well as an immediate potential for automation of methods to choose building occupied modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Calculating Design Heating Loads for Superinsulated Buildings, Ithaca, New York; Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)

Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, CARB monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Calculating Design Heating Loads for Superinsulated Buildings

Designing a superinsulated home has many benefits including improved comfort, reduced exterior noise penetration, lower energy bills, and the ability to withstand power and fuel outages under much more comfortable conditions than a typical home. Extremely low heating and cooling loads equate to much smaller HVAC equipment than conventionally required. Sizing the mechanical system to these much lower loads reduces first costs and the size of the distribution system needed. While these homes aren't necessarily constructed with excessive mass in the form of concrete floors and walls, the amount of insulation and the increase in the thickness of the building envelope can lead to a mass effect, resulting in the structures ability to store much more heat than a code built home. This results in a very low thermal inertia making the building much less sensitive to drastic temperature swings thereby decreasing the peak heating load demand. Alternative methods that take this inertia into account along with solar and internal gains result in smaller more appropriate design loads than those calculated using Manual J version 8. During the winter of 2013/2014, the Consortium for Advanced Residential Buildings team monitored the energy use of three homes in climate zone 6 in an attempt to evaluate the accuracy of two different mechanical system sizing methods for low load homes. Based on the results, it is recommended that internal and solar gains be included and some credit for thermal inertia be used in sizing calculations for superinsulated homes.

Building America↗

Water Network Tool for Resilience v. 1.0

WNTR is a python package designed to simulate and analyze resilience of water distribution networks. The software includes: - Pressure driven and demand driven hydraulic simulation - Water quality simulation to track concentration, trace, and water age - Conditional controls to simulate power outages - Models to simulate pipe breaks - A wide range of resilience metrics - Analysis and visualization tools

Source record↗

PNNL’s Shared Perspectives Technology

Shared Perspectives, one of the technologies within the PNNL-developed GridOPTICS capability suite, enables neighboring organizations, such as different electric utilities, to more effectively partner to solve outages and other grid problems. Shared Perspectives provides a means for organizations to safely stream information from different organizational service areas; the technology then combines and aligns this information into a common, global view, enhancing global situation awareness that can reduce the time it takes to talk through a problem and identify solutions. The technology potentially offers applications in other areas, such as disaster response; collaboration in the monitoring/assessment of real-time events (e.g., hurricanes, earthquakes, and tornadoes); as well as military uses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BENCHMARK ACCELERATED AGING OF HARVESTED HYPALON/EPR AND CSPE/XLPE POWER AND I&C CABLE IN NUCLEAR POWER PLANTS

As part of the Light Water Reactor and Sustainability (LWRS) program in the U.S. Department of Energy (DOE) Office of Nuclear Energy, material aging and degradation research is currently geared to support the long-term operation of existing nuclear power plants (NPPs) as they move beyond their initial 40 year licenses. The goal of this research is to provide information so that NPPs can develop aging management programs (AMPs) to address replacement and monitoring needs as they look to operate for 20 years, and in some cases 40 years, beyond their initial operating lifetimes. For cable insulation and jacket materials that support instrument, control, and safety systems, accelerated aging data are needed to determine priorities in cable aging management programs. Before accelerated thermal and radiation aging of harvested, representative cable insulation and jacket materials, the benchmark performance of a new test capability at Oak Ridge National Laboratory (ORNL) was evaluated for temperatures between 70 and 135 C, dose rates between 100 and 500 Gy/h, and accumulated doses up to 20 kGy, Samples that were characterized and are representative of current materials in use were harvested from the Callaway NPP near Fulton, Missouri, and the San Onofre NPP north of San Diego, California. From the Callaway NPP, a multiconductor control rod cable manufactured by Boston Insulated Wire (BIW), with a Hypalon/ chorolosulfonated polyethylene (CSPE) jacket and ethylene-propylene rubber (EPR) insulation, was harvested from the auxiliary space during a planned outage in 2013. This cable was placed into service when the plant was started in 1984. From the San Onofre NPP, a Rockbestos Firewall III (FRIII) cable with a Hypalon/ CSPE jacket with cross-linked polyethylene (XLPE) insulation was harvested from an on-site, climate-controlled storage area. This conductor, which was never placed into service, was procured around 2007 in anticipation of future operation that did not occur. Benchmark aging for both jacket and insulation material was carried out in air at a temperature of 125 C or in uniform 140 Gy/h gamma irradiation over a period of 60 days. Their mechanical properties over the course of their exposures were compared with reference data from comparable cable jacket/insulation compositions and aging conditions. For both accelerated thermal and radiation aging, it was observed that the mechanical properties for the Callaway BIW control rod cable were consistent with those previously measured. However, for the San Onofre Rockbestos FRIII, there was an observable functional difference for accelerated thermal aging at 125 C. Details on possible sources for this difference and plans for resolving each source are given in this paper.

Duckworth, Robert C↗

Utilizing Genetic Programming to Identify Failures in ICS Networks

Previously, researchers have attempted to apply machine learning techniques to network anomaly detection problems. Due to the staggering amount of variety that can occur in normal networks, the results have often been underwhelming. These challenges are far less pronounced when considering industrial control system (ICS) networks. The recurrent nature of these networks results in less noise and more consistent patterns for a machine learning algorithm to recognize. Here, we propose a method of evolving decision trees through genetic programming (GP) in order to detect network anomalies, such as device outages. Our approach extracts over a dozen features from network packet captures and netflows, normalizes them, and relates them in decision trees using fuzzy logic operators. Furthermore, the trees were used to detect three specific network events from three different points on the network across a statistically significant number of runs and achieved 100% accuracy on five of the nine experiments. When the trees attempted to detect more challenging events at points of presence further from the occurrence, the accuracy averaged to above 98%. Finally, using our method, all of the evolutionary cycles of the GP algorithm are computed a-priori, allowing the best resultant trees to be deployed as semi-real-time sensors with little overhead.

97 MATHEMATICS AND COMPUTING↗

Energy System Modeling with REopt

This poster details how REopt - NREL's software modeling platform for energy systems integration and optimization - can help to model energy systems. Some benefits of modeling with REopt include optimizing behind the meter storage for cost and resiliency, optimizing lab testing, optimizing dispatch of utility scale storage, and quantifying renewable energy impact on outage survivability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Defending the Power Grid from Hackers

A new initiative underway at the National Renewable Energy Laboratory is intended to prevent hackers from gaining control of parts of the nation's power grid, potentially damaging electrical equipment and causing localized power outages. Our nation's power grid is evolving to be more responsive to changing power needs, more able to integrate renewable energy, more efficient, and more reliable. One key element of this evolution is adding communication and control devices to the power grid, closer to the end user, so that utilities have greater situational awareness of the grid and can respond quickly to disturbances. But these new devices and their communications requirements can also open up the power grid to potential cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Method of Synchrophasor Technology for Detecting and Analyzing Cyber-Attacks

Studying cybersecurity events and analyzing their impacts encourage planners and operators to develop innovative approaches for preventing attacks in order to avoid outages and other disruptions. This work considers two parts in security studies; detecting an integrity attack and examining its effects on power system generators. The detection was conducted through employing synchrophasor technology to provide authentication of ACG commands based on observed system operating characteristics. The examination of an attack is completed via a detailed simulation of a modified IEEE 68-bus benchmark model to show the associated power system dynamic response. The results of the simulation are discussed for assessing the impacts of cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗