Nuclear Forensics Scanning
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Quantifying material damage and degradation under reactor conditions enables researchers to make important predictions regarding reactor safety and efficiency. More specifically, thermal property instruments serve as a powerful tool in quantifying the evolution of thermal properties under irradiation, and hence, are necessary in qualifying fuels and materials for reactor use. In addition to providing insight into thermal properties, some instruments may provide a new means of quantifying radiation damage, a challenge in modern nuclear materials research.
Pulsed-neutron die-away experiments are a promising experimental method that complement criticality benchmarks for nuclear data validation. The experiments have several advantages that include compatibility with non-fissile material, low benchmark uncertainties, and high sensitivity to absorption and scattering cross sections. When validating thermal neutron scattering laws, small targets are desirable for their large sensitivity to the scattering cross section and angular distribution. Unfortunately, room return or scattering from a shielding box limits the use of the very small targets needed to maximize sensitivity to thermal scattering laws. To address this problem, we propose changing the observable of the experiment from leaked thermal neutrons to γ-rays produced by (n, γ) reactions in the target. If feasible, this change allows removal of the shielding box, achieving higher sensitivity to thermal neutron scattering laws. This study focuses on replicating benchmark pulsed-neutron die-away experiments with γ-rays. We compare the integral parameters with γ-rays to those obtained with neutrons. We also discuss experimental design choices such as detector placement, shielding, and the presence of Cd. The results show the integral parameter with γ-rays is sensitive to detector location with respect to the target when Cd shielding is present. In addition, while Pb shielding around the γ-ray detectors do not seem to affect the integral parameter, the presence of Cd shielding does and adds background γ-rays to the die-away curves making it difficult to calculate the integral parameter.
Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.
This study presents the development of an AI-powered Zero-Trust cybersecurity framework for malware prevention in nuclear power plants. The framework aims to enhance the security of critical systems within nuclear power plants by adopting the principles of Zero-Trust and leveraging artificial intelligence (AI) technologies. By assuming no implicit trust in any user or device and continuously authenticating and authorizing access, the framework ensures a robust defense against malware attacks. The integration of AI allows for the detection and prevention of malware through behavioral analytics, endpoint protection, network segmentation, and continuous monitoring. The paper discusses the key considerations, steps, and technologies involved in developing this framework, emphasizing the importance of regular updates, training, compliance, and auditing. The proposed framework serves as a comprehensive approach to safeguarding nuclear power plants from sophisticated malware threats and protecting the integrity and safety of critical infrastructure.
Explore the source record for details and available documents.
Microcalorimetry updates from HERMES-400 located at Idaho National Laboratory will be presented. In particular, the current outlook as well as future upgrades will be discussed. Data will be presented for Byron and TRISO particle fuel measurements highlighting improved energy resolution compared to traditional gamma-ray spectroscopy.
Material for a new LiH shell for neutron shielding has been obtained for the Detector for Advanced Neutron Capture Experiments. This is a critical component for optimizing sensitivity of neutron capture experiments performed in support of Office of Experimental Sciences mission, particularly in the case of small, rare samples.
Presentation to be made on June 15 at the works in progress WebEx. Later the presentation will be uploaded to the Science and technology website.
Training nuclear forensic analysis personnel in post-detonation scenarios is of critical importance to nuclear threat response capabilities. Thus, realistic nuclear debris simulants which resemble the size, color, elemental composition, and radionuclide content of actual nuclear fallout from a recent detonation would be valuable for training nuclear first responders in realistic scenarios. As nuclear fallout types vary significantly in each of these parameters based on detonation environment (rural, urban, maritime etc.) and collection location, the ability to tailor each of these parameters accurately in simulated debris would be of immense benefit to the post-detonation analysis community for training both in-field collections and triage and the validation of laboratory level nuclear forensic techniques. Sol-gel synthesis techniques can provide the tunability of size, shape and composition required for producing surrogate nuclear debris of a wide variety. The sol-gel process consists of forming a metal oxide material, often silica, through polymerization of a metal-alkoxy precursor. In this work, we characterize the ability to load the sol-gel particles with secondary elemental components such as iron, aluminum, and calcium toward approximating the elemental composition of debris from various detonation environments and demonstrate the ability to produce particles with controllable size, shape, and color. We also demonstrate quantitative radionuclide encapsulation toward reproducing the radionuclide content of actual fallout from a recent detonation. Finally, we then employ these techniques in producing simulated aerodynamic debris samples with realistic elemental matrix composition and radionuclide content simulating a recent uranium-fueled detonation taking place in a rural desert environment and compare it to historic fallout from the Nevada Nuclear Security Site.
The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.
Explore the source record for details and available documents.
The Department of Energy Office of Nuclear Energy (DOE-NE) vision is to “Advance nuclear energy science and technology to meet U.S. energy, environmental, and economic needs.” The Materials and Fuels Complex (MFC) serves as the foundation of a nuclear RD&D enabling test bed at Idaho National Laboratory (INL) and is an integral part of a National Reactor Innovation Center (NRIC) strategy. MFC facilities focus on developing and maintaining RD&D capabilities that can increase research throughput, reduce barriers to deployment, and facilitate commercialization of new ideas and technologies for clean and secure sources of energy.
Idaho National Laboratory is designing and constructing a solvent extraction test bed, Beartooth, as part of a nuclear fuel cycle stewardship initiative. The test bed will provide facilities and equipment for testing novel extraction processes and give early career scientists opportunities to gain skills in performing separations chemistry. The test bed is being uniquely designed to enable machine learning capabilities for the characterization of chemical process operations. One of the intentions of incorporating machine learning methods is to provide process operators with enhanced situational awareness for the optimization of separations techniques and possible detection of a diversion event. As a result, the objective of this Laboratory Directed Research and Development project is to develop a multi-sensor data collections system and implement machine learning techniques on signals from an existing centrifugal contactor cascade to identify equipment usage and process events. This presentation will provide an overview of sensors used and experiments conducted to date.
A suite of six neutron time of flight detectors capable of measuring the primary DT neutron energy spectrum has recently been completed on the OMEGA Laser System. The detectors are positioned along multiple quasi-orthogonal lines of sight (LOS’s) in either a stand-alone, collinear, or antipodal configuration. The collinear detector configuration enables one to measure the neutron velocity along the detector LOS independent of the neutron-production history, while the antipodal detector configuration enables one to directly measure of the hot-spot velocity along the detector axis and Gamow velocity shift due to the plasma ion temperature. Using these six measurements of the primary DT neutron energy spectrum, the neutron-averaged hot-spot velocity and Gamow velocity shift of DT fusion neutrons have been measured in cryogenic experiments on OMEGA for the first time. Finally, the detector suite is operable between DT neutron yields of 1 × 10 13 to 2 × 10 14 with an uncertainty of ~14 km/s in the neutron-averaged hot-spot velocity measurement.
A novel 6 MeV hybrid photo-injector has been designed and constructed, based on a smaller-scale prototype previously built in UCLA’s Particle Beam Physics Laboratory. It has been commissioned at Ariel University in Israel as an on-going collaboration between the two universities. This unique, new generation design provides a radically simpler approach to RF feeding of a gun/buncher system, leading to a much shorter beam via velocity bunching owed to an attached traveling wave section of the photo-injector. This design offers better performance in beam parameters, providing a high quality electron beam, with energy of 6 MeV. The hybrid photo-injector was designed to provide emittance of approximately 3 μm, and pulse duration of 150 fs at up to 1 nC per pulse. The hybrid gun is driven by a SLAC XK5 klystron as the high power RF source, and third harmonic of a ~35 fs IR Laser amplifier (266 nm) to extract electrons from the photo-cathode. The unique electron gun will produce a bunched electron pulse to drive a THz FEL, which will operate at the super-radiant regime, and therefore requires ambitious beam properties. This paper describes the gun and presents experimental results from the gun and its sub-systems, including energy and charge measurements, compared with the design simulations.
The main goal of development of the new Dubna Gas-Filled Recoil Separator (DGFRS-2) is to sufficiently improve the efficiency of studies on heavy and superheavy nuclei at the Super Heavy Element Factory of the Flerov Laboratory of Nuclear Reactions (FLNR) at the Joint Institute for Nuclear Research. The use of beams with the intensity up to 6×10 13 s -1 (10 pμA) delivered by the DC280 cyclotron requires an effective setup providing high suppression of background reaction products. Additionally, the described gas-filled separator is optimized for synthesis and study of heavy isotopes produced in complete fusion reactions of massive nuclei. Basic characteristics of DGFRS-2, as well as the results of the first test experiments, are presented. In comparison to the DGFRS-1, the transmission efficiency was doubled, and the background was reduced by a factor 200.
In this work, we have designed and tested a large-area (0.15 m 2 ) neutron detector based on neutron capture on 6Li. The neutron detector design has been optimized for the purpose of tagging the scattering angle of keV-scale neutrons. These neutron detectors would be employed to calibrate the low-energy (<100 eV) nuclear recoil in detectors for dark matter and coherent elastic neutrino nucleus scattering (CE$\textit{v}$NS). We describe the design, construction, and characterization of a prototype. The prototype is designed to have a tagging efficiency of ~25% at the relevant $\mathcal{O}$(keV) neutron energies, and with a mean capture time of ~ 17 μs. The prototype was characterized using a 252 Cf neutron source and agreement with the simulation was observed within a few percent level.