Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Using gamma-ray emission to measure areal density of inertial confinement fusion capsules

Fusion neutrons streaming from a burning inertial confinement fusion capsule generate gamma rays via inelastic nuclear scattering in the ablator of the capsule. The intensity of gamma-ray emission is proportional to the product of the ablator areal density ({rho}R) and the yield of fusion neutrons, so by detecting the gamma rays we can infer the ablator areal density, provided we also have a measurement of the capsule's total neutron yield. In plastic-shell capsules, for example, {sup 12}C nuclei emit gamma rays at 4.44 MeV after excitation by 14.1 MeV neutrons from D+T fusion. These gamma rays can be measured by a new gamma-ray detector under development. Analysis of predicted signals is in progress, with results to date indicating that the method promises to be useful for diagnosing imploded capsules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo calibration of the SMM gamma ray spectrometer for high energy gamma rays and neutrons

The Gamma Ray Spectrometer (GRS) on the Solar Maximum Mission spacecraft was primarily designed and calibrated for nuclear gamma ray line measurements, but also has a high energy mode which allows the detection of gamma rays at energies above 10 MeV and solar neutrons above 20 MeV. The GRS response has been extrapolated until now for high energy gamma rays from an early design study employing Monte Carlo calculations. The response to 50 to 600 MeV solar neutrons was estimated from a simple model which did not consider secondary charged particles escaping into the veto shields. In view of numerous detections by the GRS of solar flares emitting high energy gamma rays, including at least two emitting directly detectable neutrons, the calibration of the high energy mode in the flight model has been recalculated by the use of more sophisticated Monte Carlo computer codes. New results presented show that the GRS response to gamma rays above 20 MeV and to neutrons above 100 MeV is significantly lower than the earlier estimates.

Cooper, J. F.↗

Fissile material measurements using the differential die-away self interrogation technique

Currently, there is substantial research effort focused on quantifying plutonium (Pu) mass in spent fuel using non-destructive assay (NDA) techniques. Of the several techniques being investigated for this purpose, Differential Die-Away Self-Interrogation (DDSI) is a recently proposed, neutron-based NDA technique capable of quantifying the total fissile content in an assembly. Unlike the conventional Differential Die-Away (DDA) technique, DOSI does not require an external neutron source for sample interrogation, but rather, uses the spontaneous fission neutrons originating from {sup 244}Cm within the spent fuel for self-interrogation. The essence of the technique lies in the time separation between the detection of spontaneous fission neutrons from {sup 244}Cm and the detection of induced fission neutrons at a later time. The DDSI detector design imposes this time separation by optimizing the die-away times ({tau}) of the detector and sample interrogation regions to obtain an early and late neutron distribution respectively. The ratio of the count rates in the late gate to the early gate for singles, doubles, and triples is directly proportional to the fissile content present in the sample, which has already been demonstrated for simplified fuel cases using the Monte Carlo N-Particle eXtended (MCNPX) code. The current work applies the DDSI concept to more complex samples, specifically spent Pressurized Water Reactor (PWR) assemblies with varying isotopics resulting from a range of initial enrichment, bumup, and cooling time. We assess the feasibility of using the late gate to early gate ratio as a reliable indicator of overall fissile mass for a range of assemblies by defining a {sup 239}Pu effective mass which indicates the mass of {sup 239}Pu that would yield the same DDSI signal as the combined mass of major fissile isotopes present in the sample. This work is important for assessing the individual capability of the DDSI instrument in quantifying fissile mass in an assembly in order to use this information for a possible integration with another NDA instrument for direct Pu mass determination.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Systematic Assessment of Neutron and Gamma Backgrounds Relevant to Operational Modeling and Detection Technology Implementation

This report summarizes the findings of a two year effort to systematically assess neutron and gamma backgrounds relevant to operational modeling and detection technology implementation. The first year effort focused on reviewing the origins of background sources and their impact on measured rates in operational scenarios of interest. The second year has focused on the assessment of detector and algorithm performance as they pertain to operational requirements against the various background sources and background levels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron spectroscopy of plutonium using a handheld detection system

The ability to distinguish multiple forms of plutonium from one another, such as oxide and metal, is paramount in areas of nuclear nonproliferation and international safeguards. In its metal form, plutonium can be readily used in a nuclear weapon, while oxide forms are associated with nuclear reactor fuel. Oxide-based plutonium forms emit neutrons with an energy spectrum that is significantly different from the fission neutrons that are emitted from plutonium metal. Organic scintillation detectors output pulses that are proportional to the neutron energy deposited, and therefore present a means of distinguishing these plutonium forms based on their energy spectra. In this work, metal and oxide forms of plutonium were measured using a handheld detection system based on an organic glass scintillator. Monte Carlo modeling of these experiments was performed to provide insight into the origin of the features in the observed light output spectra. Through analysis of multiple regions of these spectra, in a matter of minutes we were able to unambiguously discriminate oxide and metal plutonium forms from one another and from a plutonium-beryllium neutron source, which was considered for comparison because these sources are commonly used in industrial applications. The ability to discriminate weapons-usable material from nuclear reactor fuel has applications in nuclear treaty verification and safeguards.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Real-Time Simultaneous 3D Volumetric Imaging and Mapping of Gamma-ray and Neutron Sources

The invention combines radiation detection instrumentation, data processing algorithms, and visualization software to enable, for the first time ever, simultaneous, real-time imaging of both gamma ray and neutron sources (fast and slow). Radiation detectors sensitive to gamma rays and neutrons are integrated with readout electronics that allow discriminated particles to be incorporated into real-time 3D volumetric reconstructions as two separate data streams. Using the Scene Data Fusion (SDF) conceptual framework and contextual sensors from the Localization and Mapping Platform (LAMP) developed at LBNL, gamma-ray and neutron data are fused onto contextual information from the environment around the detection system. The invention is compatible with radiation detection media capable of detecting and discriminating between gamma rays and neutrons or the pairing of multiple detectors separately capable of detecting gamma rays and/or neutrons. It can be integrated into a compact, lightweight imaging platform for operation as a hand-carry device, on unmanned aerial systems, and with unmanned vehicles. The ability to measure neutron enables the detection and 3D localization of shielded nuclear materials such as Pu-239 which is not possible with means of gamma-ray detection and spectroscopy overcoming of major limitation in the detection of such materials to-date.

Cates, Joshua↗

Development of Fast Measurement System of Neutron Emission Profile Using a Digital Signal Processing Technique in JT-60U

Neutron emission profiles are routinely measured in JT-60U Tokamak. Stinbene neuron detectors (SNDs), which combine a Stilbene organic crystal scintillation detector (Stilbene detector) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure neutron flux efficiently. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to {approx}1x 10{sup 5} counts/s due to the dead time of the analog PSD circuit. To overcome this issue, a digital signal processing (DSP) system using a Flash-ADC has been developed. In this system, anode signals from the photomultiplier of the Stilbene detector are fed to the Flash ADC and digitized. Then, the PSD between neutrons and gamma-rays are performed using software. The photomultiplier tube is also modified to suppress and correct gain fluctuation of the photomultiplier. The DSP system has been installed in the center channel of the vertical neutron collimator system in JT-60U and applied to measurements of neutron flux in JT-60U experiments. Neutron flux are successfully measured with count rate up to {approx}1x 10{sup 6} counts/s without the effect of pile up of detected pulses. The performance of the DSP system as a neutron detector is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RPI LINAC refurbishment and upgrade project

The Electron Linear Accelerator at Rensselaer Polytechnic Institute (RPI) was constructed in the late 1950s and started operation in 1961 [1]. The facility was designed and used primarily for measurements of Nuclear Data (ND) with emphasis on the resonance energy region. As such it was designed to produce short pulses of neutrons (5-5000 ns) and equipped with detection stations at different neutron flight path distances from the source (15 m-250 m). When the LINAC started operation it was one of the most powerful accelerators in the world for high energy-resolution measurements in the resonance region. The original LINAC with some upgrades is still in operation but no longer provides world class capabilities for measurements with short pulses. In 2011 discussions between the RPI ND group, Naval Reactors, and the Nuclear Criticality Safety Program about the future of the LINAC concluded that maintaining the capability to perform world-class nuclear data measurements at RPI was desirable. To that end, it was decided to refurbish the facility and upgrade the accelerator capabilities to enable high accuracy measurement in the resonance region with narrow neutron pulse and high electron beam power. Located at a major US technical university, this project provides a needed US nuclear data capability for both research and education, and also includes external users and industrial applications.

43 PARTICLE ACCELERATORS↗

Neutron camera employing row and column summations

For each photomultiplier tube in an Anger camera, an R.times.S array of preamplifiers is provided to detect electrons generated within the photomultiplier tube. The outputs of the preamplifiers are digitized to measure the magnitude of the signals from each preamplifier. For each photomultiplier tube, a corresponding summation circuitry including R row summation circuits and S column summation circuits numerically add the magnitudes of the signals from preamplifiers for each row and for each column to generate histograms. For a P.times.Q array of photomultiplier tubes, P.times.Q summation circuitries generate P.times.Q row histograms including R entries and P.times.Q column histograms including S entries. The total set of histograms include P.times.Q.times.(R+S) entries, which can be analyzed by a position calculation circuit to determine the locations of events (detection of a neutron).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the neutrino-spin correlation parameter B neutron decay using ultracold neutrons

We present a new approach to measuring the neutrino-spin correlation parameter B in neutron decay. The approach combines the technology of large-area ion-implanted silicon detectors being developed for the abBA experiment, with an ultracold neutron source to provide more precise neutron polarimetry. The technique detects both proton and electron from the neutron decay in coincidence. B is determined from an electron-energy-dependent measurement of the proton spin asymmetry. This approach will provide a statistical precision of 1 x 10-4 . The systematic precision is still being evaluated, but is expected to be below 1 x 10-3 , and could approach 1 x 10-4 . A measurement of B with this precision would place constraints on supersymmetric extensions to the Standard Model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Uncertainty Quantification of Spatial Correction Factor for Sjoestrand Method due to Cross-section Data

Accelerator-driven System (ADS), which couples a subcritical core with a spallation neutron source, is proposed as a nuclear transmutation technology to reduce the radioactive half-life of high-level waste. To maintain a safe operation in ADS, the core should be kept in subcritical state. Thus, the subcritical state of the core must be quantified through measurement of subcriticality, which is a quantitative margin from critical state. The area ratio method, or the Sjoestrand method, is one of the subcriticality measurement techniques applicable to the ADS. In this method, the absolute value of subcriticality can be obtained by analyzing the temporal variation of neutron density in the core due to the periodic injection of neutron pulses. In practice, the value of subcriticality is measured by the temporal variation of neutron count rate detected by a detector in the core. Time integrals of count rates due to prompt and delayed neutrons A{sub p} and A{sub d}, are measured. Then, the ratio of A{sub p} to A{sub d}, which is called as the area ratio, yields negative reactivity -ρ, i.e. subcriticality, in dollar units: A{sub p}/A{sub d} ≅ -ρ/β{sub eff'} (1) where β{sub eff} is the effective delayed neutron fraction. Equation (1) represents the basic idea of the Sjoestrand method. Note, however, that Eq. (1) is approximately derived using the point kinetics model. In an actual subcritical system, the measured area ratio is not necessarily equal to the exact value of subcriticality in dollar units, due distortion by spatial higher-order modes. Hence, in the actual measurement, this spatial effect is corrected by a spatial correction factor such as the Bell and Glasstone correction factor (the Bell factor), or by extraction of the fundamental mode (so-called the extrapolated area ratio method). In addition, there is an effect due to the neutron detector materials (e.g. {sup 3}He(n,p) and {sup 235}U(n,f)). These effects must be considered in the correction of the measured area ratio. In this study, we focused on the uncertainty of Bell factor. The Bell factor f is defined by the ratio of the area ratio to the subcriticality as follows: f ≡ -[ρ/β{sub eff}]/[A{sub p}/A{sub d}] (2) The Bell factor f can be evaluated by a core analysis. By multiplying the measured area ratio by the Bell factor?, the spatial higher-order mode effect in the area ratio can be corrected. However, the uncertainty of the Bell factor due to uncertainties of cross-section data (covariance data) has not been quantitatively evaluated so far. In this study, we propose a method to quantify the uncertainty of the Bell factor in an actual core analysis. As a feasibility study, the uncertainty quantification is carried out in a simple one-dimensional subcritical core system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron proton crystallography station (PCS)

The PCS (Protein Crystallography Station) at Los Alamos Neutron Science Center (LANSCE) is a unique facility in the USA that is designed and optimized for detecting and collecting neutron diffraction data from macromolecular crystals. PCS utilizes the 20 Hz spallation neutron source at LANSCE to enable time-of-flight measurements using 0.6-7.0 {angstrom} neutrons. This increases the neutron flux on the sample by using a wavelength range that is optimal for studying macromolecular crystal structures. The diagram below show a schematic of PCS and photos of the detector and instrument cave.

59 BASIC BIOLOGICAL SCIENCES↗

Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination

Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.

36 MATERIALS SCIENCE↗

Future prospects of nuclear reactions induced by gamma-ray beams at ELI-NP

The future prospects of photonuclear reactions studies at the new Extreme Light Infrastructure—Nuclear Physics (ELI-NP) facility are discussed in view of the pursuit of investigating the electromagnetic response of nuclei using γ-ray beams of unprecedented energy resolution and intensity characteristics. We present here the features of the γ-ray beam source, the emerging ELI-NP experimental program involving photonuclear reactions cross section measurements and spectroscopy and angular measurements of γ-rays and neutrons along with the detection arrays currently under implementation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time encoded radiation imaging

The various technologies presented herein relate to detecting nuclear material at a large stand-off distance. An imaging system is presented which can detect nuclear material by utilizing time encoded imaging relating to maximum and minimum radiation particle counts rates. The imaging system is integrated with a data acquisition system that can utilize variations in photon pulse shape to discriminate between neutron and gamma-ray interactions. Modulation in the detected neutron count rates as a function of the angular orientation of the detector due to attenuation of neighboring detectors is utilized to reconstruct the neutron source distribution over 360 degrees around the imaging system. Neutrons (e.g., fast neutrons) and/or gamma-rays are incident upon scintillation material in the imager, the photons generated by the scintillation material are converted to electrical energy from which the respective neutrons/gamma rays can be determined and, accordingly, a direction to, and the location of, a radiation source identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron counter based on beryllium activation

The fusion reaction occurring in DD plasma is followed by emission of 2.45 MeV neutrons, which carry out information about fusion reaction rate and plasma parameters and properties as well. Neutron activation of beryllium has been chosen for detection of DD fusion neutrons. The cross-section for reaction {sup 9}Be(n, α){sup 6}He has a useful threshold near 1 MeV, which means that undesirable multiple-scattered neutrons do not undergo that reaction and therefore are not recorded. The product of the reaction, {sup 6}He, decays with half-life T{sub 1/2} = 0.807 s emitting β{sup −} particles which are easy to detect. Large area gas sealed proportional detector has been chosen as a counter of β–particles leaving activated beryllium plate. The plate with optimized dimensions adjoins the proportional counter entrance window. Such set-up is also equipped with appropriate electronic components and forms beryllium neutron activation counter. The neutron flux density on beryllium plate can be determined from the number of counts. The proper calibration procedure needs to be performed, therefore, to establish such relation. The measurements with the use of known β–source have been done. In order to determine the detector response function such experiment have been modeled by means of MCNP5–the Monte Carlo transport code. It allowed proper application of the results of transport calculations of β{sup −} particles emitted from radioactive {sup 6}He and reaching proportional detector active volume. In order to test the counter system and measuring procedure a number of experiments have been performed on PF devices. The experimental conditions have been simulated by means of MCNP5. The correctness of simulation outcome have been proved by measurements with known radioactive neutron source. The results of the DD fusion neutron measurements have been compared with other neutron diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma-rays and neutrons as a probe of the proton spectrum during the solar flare of 1988 December 16

We have previously reported on high-energy gamma-rays and neutrons from the flare of 1988 December 16 detected by the Gamma-Ray Spectrometer on the SMM satellite. In this paper, we present results on gamma-ray lines seen by the same detector during this flare. Together, these measurements constitute a powerful probe of the proton spectrum that produces the flare neutrals. Analysis of the data suggests a Bessel-function proton spectrum with a shape parameter (alpha T) of 0.054 +/- 0.004 and the number of protons above 30 MeV equal to (9.0 +/- 0.9) x 10 exp 32. The number of neutrons detected from this flare is much smaller than what is predicted from an isotropic distribution of the protons, indicating that the distribution may be nonisotropic.

Dunphy, P. P.↗

Detection of vapor nanobubbles by small angle neutron scattering (SANS)

Experiments using boiling water on untreated (roughness 100–300 nm) metal surfaces using small-angle neutron scattering (SANS) show the appearance of structures that are 50–70 nm in size when boiling is present. The scattering signal disappears when the boiling ceases, and no change in the signal is detected at any surface temperature condition below saturation. This confirms that the signal is caused by vapor nanobubbles. Two boiling regimes are evaluated herein that differ by the degree of subcooling (3–10 °C). A polydisperse spherical model with a log-normal distribution fits the SANS data well. In conclusion, the size distribution indicates that a large number of nanobubbles exist on the surface during boiling, and some of them grow into large bubbles.

74 ATOMIC AND MOLECULAR PHYSICS↗