Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Background and Lunar Neutron Populations Detected by LEND and Average Concentration of Near-Surface Hydrogen near the Moon's Poles

Neutron flux measurements by the Lunar Exploration Neutron Detector (LEND) on the Lunar Reconnaissance Orbiter (LRO) enable quantifying hydrogen-bearing volatiles in the lunar surface from orbit. Accurately determining hydrogen abundance requires discriminating between the instrument background detection rate and the population of lunar-sourced neutrons that are sensitive to surficial hydrogen. We have investigated the detection rate for lunar and non-lunar (spacecraft-sourced) neutrons in LEND by modeling maps of measured count rate in three LEND detector systems using linear combinations of maps compiled from LEND detectors and from the Lunar Prospector Neutron Spectrometer. We find that 30% of the global-average 24.926 0.020 neutron counts per second (cps) detected by the LEND STN3 thermal-energy neutron sensor are lunar-sourced neutrons in the thermal energy range (E < 0.4 eV), 65% are lunar-sourced neutrons in the epithermal and fast energy range (E > 0.4 eV), and 5% are from spacecraft-sourced background signal. In the SETN epithermal neutron detector, 90% of the 10.622 0.002 neutron detections per second are consistent with a lunar source of epithermal and fast neutrons combined (E > 0.4 eV), with 3% due to lunar-sourced thermal neutron leakage into the detector (E < 0.4 eV), and background signal accounting for 7% of total detections. Background signal due to spacecraft-derived neutrons is substantial in the CSETN collimated detector system, accounting for 57% of the global average detection rate of 5.082 0.001 cps, greater than the 48% estimated from cruise-phase data. Lunar-sourced epithermal and fast neutrons account for 43% of detected neutrons, including neutrons in collimation as well as neutrons that penetrate the collimator wall to reach the detector. We estimate a lower limit of 17% of lunar-sourced neutrons detected by CSETN are epithermal neutrons in collimation (0.37 cps), with an upper limit estimate of 54 11% of lunar-sourced neutrons received in collimation, or 1.2 0.2 cps global average. The pole-to-equator contrast ratio inepithermal and high-energy epithermal neutron flux indicates that the average concentration of hydrogen in the polar regolith above 80 north or south latitude is ~105 ppmw (parts per million by weight), or 0.095 0.01 wt% water-equivalent hydrogen. Above 88 north or south, the concentration increases to ~140 ppmw, or 0.13 0.02 wt% water-equivalent hydrogen. The similar pattern of neutron flux suppression at both poles suggests that hydrogen concentration generally increases nearer the pole and is not closely associated with a specific feature such as Shackleton Crater at the lunar south pole that has no northern counterpart. Epithermal neutron flux decreases with increasing latitude outside the polar regions, consistent with surface hydration that increases with latitude if that hydration extends to ~13-40 cm into the surface.

Livengood, Timothy A.↗

Inferring neutron yields using indium activation samples for small fractions of tritium added to deuterium fuel in inertial confinement fusion (ICF) experiments

In inertial confinement fusion experiments, the neutron yield is an important metric for thermonuclear fusion performance. Neutron activation diagnostics can be used to infer neutron yields. The material used for neutron activation diagnostic undergoes a threshold reaction so that only neutrons having energies above the threshold energy are observed. For thermonuclear experiments using deuterium (D) and tritium (T) fuel constituents, neutrons arising from D + D reactions (DD-neutrons) and neutrons resulting from D + T reactions (DT-neutrons) are of primary interest. Indium has two neutron activation reactions that can be used to infer yields of DD-neutrons and DT-neutrons. One threshold is high enough that only DT-neutrons can induce activation, the second reaction can be activated by both DD-neutrons and DT-neutrons. Thus, to obtain the DD-neutron yield, the contribution made by DT-neutrons to the total induced activity must be extracted. In DD-fuel experiments, DT-neutrons arise from secondary reactions, which are significantly lower in number than primary DD-neutrons, and their contribution to the inferred DD-neutron yield can be ignored. When the DD- and DT-neutron yields become comparable, such as when low tritium fractions are added to DD-fuel, the contribution of DT-neutrons must be extracted to obtain accurate yields. A general method is described for this correction to DD-neutron yields.

Mangan, M. A. (ORCID:000000034583700X)↗

Thermal Flux Maximization from a DD Neutron Generator

The University of Sharjah recently acquired a model DD-109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. The neutron ports are plugged with polyethylene layers of different thickness in order to control the neutron flux at different regions in the port. Neutron Activation Analysis (NAA) is an important analysis technique to determine the amounts of isotopes in a sample at different concentrations. For many isotopes the ability to precisely determine their concentrations is enhanced by utilizing thermal neutrons in the activation process; where the capture cross section is greatest. It is thus important to subject the sample to the maximum thermal flux in order to minimize the time required to activate the sample and consequently extend the lifetime of the neutron generator. A detailed MCNP model of the neutron generator has been developed for the purpose of determining the moderator thickness required to maximize the thermal neutron flux in the neutron port. The maximization of the neutron flux must therefore take into account both the forward and backscattered neutrons reaching the sample. Also provided in this work is a mapping of the thermal flux at different moderator thicknesses in order to study the variation of the flux over the area of the sample. The developed model will be used as the basis for optimizing experiments and predicting their results. A study was performed to determine the moderator thickness needed to maximize the thermal neutron flux that can be obtained from a DD neutron generator. This has a significant role in the efficient utilization of the neutron generator. The maximum thermal neutron flux was found at approximately a 3.2 cm moderator thickness. The thermal neutron flux is resulting from both the directly moderated neutrons and the backscattered neutrons from the surrounding polyethylene. The results obtained in this work will be verified experimentally by irradiating samples at different moderator thickness and performing a neutron activation analysis for these samples. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Production of Neutrons by Transport of a GCR Solar Minimum Spectrum through Shielding - Paper 112

The requirements for radiation instrumentation in space can be quite different from those used for terrestrial applications. For example, most neutron instruments used for dosimetry applications used on Earth are sensitive to fission neutron energies and lower, and as such are only useful for neutron energies below 20 to 50 MeV. In space, neutrons are created by galactic cosmic ray (GCR) and solar energetic particle (SEP) interactions in materials, and as such can attain TeV energies and higher. The purpose of this study is to determine the significance of the flux of high energy neutrons in space, and to what degree neutron instruments in space must be sensitive to those high energy neutrons. PHITS transport code calculations of secondary neutron production through various thicknesses of aluminum and water shielding indicate that a significant fraction of the neutron flux and neutron effective dose comes from neutrons above 20 MeV. Measurement of high energy neutrons in space is a difficult task, especially given that the measurement will take place in a mixed radiation field where any signal from an incident neutron must be separated from signals generated by gamma rays, electrons and charged hadrons. Conventional neutron detection methodology dictates that the ability to detect high energy neutrons with a sufficient efficiency depends on the mass of the neutron detector, to first order. The more mass a neutron detector has, the higher the probability of detecting a high energy neutron. However, adding mass comes at a premium in space, often adding costs that prohibit the implementation of a new design with more mass. Thus, to accurately measure the effective dose to humans in space from secondary neutron irradiation, it requires novel methodologies that can stretch the limits of low-mass neutrons detectors, such as developing versatile response functions that are well characterized and can function over a wide range of very different neutron energy spectra. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secondary neutron spectrum from 250-MeV passively scattered proton therapy: Measurement with an extended-range Bonner sphere system

Purpose: Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. Methods: The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. Results: The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. Conclusions: The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire energy range being measured, i.e., thermal to 250 MeV. The authors used the neutron fluence spectrum to demonstrate experimentally the contribution of neutrons with different energies to the total dose equivalent and in particular the contribution of high-energy neutrons (≥20 MeV). These are valuable reference data that can be directly compared with Monte Carlo and experimental data in the literature.

07 ISOTOPE AND RADIATION SOURCES↗

Notes on the Lumped Backward Master Equation for the Neutron Extinction/Survival Probability

The expected or mean neutron number (or density) provides an adequate characterization of the neutron population and its dynamical excursions in most neutronic applications, in particular power reactors. Fluctuations in the neutron number, originating from the inherent randomness of neutron interactions and fission neutron multiplicities, are relatively small and ignorable for operational purposes, although measurements of the variance and time correlations provide valuable diagnostic information on fundamental reactor physics parameters. However, it is well known that there exist situations of great interest and importance in which a strictly deterministic description, or even one supplemented with a knowledge of low order statistical averages (variance, correlation), provides an incomplete and very unsatisfactory description of the state of the neutron population. These situations are marked by persistent large fluctuations in the neutron number where the emergence of a deterministic phase is suppressed. Such situations are strongly stochastic and therefore unpredictable (i.e., the mean is not representative of the actual population), and can arise either by design or by accident. Examples where the stochastic behavior of neutron populations must be taken into account include: nuclear weapon single-point safety assessment; criticality excursions in spent fuel storage and in the handling of fissile solutions in fuel fabrication and reprocessing; approach to critical under suboptimal reactor start-up conditions; preinitiation in fast burst research reactors; and weak nuclear signatures in the passive detection of nuclear materials. What distinguishes strongly stochastic neutronic systems from strongly deterministic systems is that, in the former, neutron multiplication occurs in the presence of weak neutron sources, such as spontaneous fission and background (cosmic) radiation. Weak sources (in a sense that can be made quite precise) lead to well separated fission chains (a fission chain is defined as the initial source neutron and all its subsequent progeny) in which some chains are short lived while others propagate for unusually long times. Under these conditions, fission chains do not overlap strongly and this precludes the cancellation of neutron number fluctuations necessary for the mean to become established as the dominant measure of the neutron population. The fate of individual chains then plays a defining role in the evolution of the neutron population in strongly stochastic systems, and of particular interest and importance in supercritical systems is the extinction probability, defined as the probability that the neutron chain (initiating neutron and its progeny) will be extinguished at a particular time, or its complement, the time-dependent survival probability. The time-asymptotic limit of the latter, the probability of divergence, gives the probability that the neutron population will grow without bound, and is more commonly known as the probability of initiation or just POI. The ability to numerically compute these probabilities, with high accuracy and without overly restricting the underlying physics (e.g., fission neutron multiplicity, reactivity variation) is clearly essential in developing an understanding of the behavior of strongly stochastic systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Energy Selective Neutron Imaging at the PULSTAR Reactor

Neutron imaging is complementary to X-ray imaging where both are used to investigate the internal features of objects nondestructively. Historically, it only began three years after discovery of the neutron in 1932, however, neutron radiographs with reasonable quality were first made in the mid-fifties. Conventionally, the image is produced by placing the object between the neutron source and a two-dimensional position sensitive detector. The source commonly has a full energy spectrum (white beam) of thermal or cold neutrons to obtain high intensity in the sample and short exposure time. As a result, all neutron energies contribute to the obtained radiograph. Since the interaction of the neutron with matter is energy dependent, different energies produce different contrast on the radiographic image, hence, additional information about the object can be obtained. Neutron imaging that utilizes a narrow spectrum of energy instead of white beam is called energy selective neutron imaging. Many techniques have been explored to select a narrow band of neutron energy for the use in imaging such as the use velocity selectors, double crystal Monochromators, and time of flight techniques (at pulsed neutron sources). The PULSTAR reactor of North Carolina State University (1 MWth) currently has an operational neutron powder diffractometer (NPD) installed on beam tube no. 4, which was designed for neutron scattering experiments and can provide a monoenergetic beam of neutrons. The neutron energy could be selected by diffraction means using a Si bent perfect crystal as a Monochromator. In this work, an investigation of energy selective neutron imaging at the NPD is discussed in terms of the system performance and the ability of material discrimination on a test sample by observing the contrast variations of the neutron radiographs obtained using different neutron energies. Energy selective neutron imaging experiment was successfully tested at the PULSTAR reactor's NPD. Although, the uniform region is small and the exposure time is long in comparison with the NIF, both facilities exhibit similar spatial resolution which is a very important characteristic for any imaging facility. The contrast variation of neuron radiographs for the test sample obtained at different energies indicated a potential advantage for using energy selective neutron imaging over the white beam. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Edge localized modes of cold neutrons in periodic condensed media

It is found that for certain energies of discreet cold neutrons, quasi-stationary eigen solutions of the corresponding Schrodinger equation, which are localized in the layer of a periodic medium, exist. The localization time of these solutions is strongly dependent on the layer thickness, being finite for a finite layer thickness and increasing indefinitely upon a infinite growth of the layer thickness as the third power of the layer thickness. The problem has been solved in the two-wave approximation of the dynamic diffraction theory for the neutron propagation direction coinciding with the periodicity axes (normal incidence of the neutron beam on the layer). The expressions for neutron eigenwave functions in a periodic medium, the reflection and transmission coefficients, and the neutron wavefunction in the layer as a function of the neutron energy incident on the layer have been determined. It turns out that for the certain discrete neutron energies, the amplitudes of the neutron wavefunction in the layer reach sharp maxima. The corresponding energies are just outside of the neutron stop band (energies forbidden for neutron propagation in the layer) and determine the energies of neutron edge modes (NEMs) localized in the layer, which are direct analogs of the optical edge modes for photonic crystals. The dispersion equation for the localized neutron edge modes has been obtained and analytically solved for the case of thick layers. A rough estimate for the localization length L is L ~(db N){sup –1}, where b is the neutron scattering length, d is the crystal period, and N is the density of nuclei in the crystal. The estimates of the localized thermal neutron lifetime show that acheaving of a lifetime close to the free neutron lifetime seems nonrealistic due to absorption of thermal neutrons and requires a perfect large size crystal. Nevertheless, acheaving the localized neutron lifetime exceeding by ~10{sup 4} times the neutron time of flight through the layer appears as experimentally attainable. The perspectives of the NEM observation are briefly discussed. It is proposed to use NEM for ultrahigh thermal neutron monochromatization by means of NEM excitation in perfect single crystals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of Large Neutron Detectors Containing Lithium-Gadolinium-Borate Scintillator

This paper describes the development and testing of a neutron counter, spectrometer, and dosimeter that is compact, efficient, and accurate. A self-contained neutron detection instrument has wide applications in health physics, scientific research, and programs to detect, monitor, and control strategic nuclear materials (SNM). The 1.3 liter detector head for this instrument is a composite detector with an organic scintillator containing uniformly distributed {sup 6}Li{sub 6}{sup nat}Gd{sup 10}B{sub 3}O{sub 9}:Ce (LGB:Ce) microcrystals. The plastic scintillator acts to slow impinging neutrons and emits light proportional to the energy lost by the neutrons as they moderate in the detector body. Moderating neutrons that have slowed sufficiently capture in one of the Lithium-6, Boron-10, or Gadolinium-157 atoms in the LGB:Ce scintillator, which then releases the capture energy in a characteristic cerium emission pulse. The measured captured pulses indicate the presence of neutrons. When a scintillating fluor is present in the plastic, the light pulse resulting from the neutron moderating in the plastic is paired with the LGB:Ce capture pulse to identify the energy of the neutron. About 2% of the impinging neutrons lose all of their energy in a single collision with the detector. There is a linear relationship between the pulse areas of this group of neutrons and energy. The other 98% of neutrons have a wide range of collision histories within the detector body. When these neutrons are 'binned' into energy groups, each group contains a distribution of pulse areas. This data was used to assist in the unfolding of the neutron spectra. The unfolded spectra were then validated with known spectra, at both neutron emitting isotopes and fission/accelerator facilities. Having validated spectra, the dose equivalent and dose rate are determined by applying standard, regulatory damage coefficients to the measured neutron counts for each energy bin of the spectra. Testing at the Los Alamos Neutron Science Center (LANSCE), Edwards Accelerator Laboratory (EAL) at Ohio University and the Radiation Center at University of Massachusetts-Lowell has demonstrated that the instrument can measure neutrons and their spectra over the range between 0.8 MeV and 150 MeV with an uncertainty of only ± 8%. An independent test of the LGB:Ce neutron spectrometer was conducted by a US Defense Threat Reduction Agency (DTRA) team at the Idaho National Laboratory (INL). The results of this evaluation showed that the neutron spectrometer accurately identified bare radioactive isotopes by their spectra. Further, masking and shielding materials alter those spectra in predictable ways that permit an extrapolation from the observed spectra back to the identity of the isotopic spectrum. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility Studies on a Hexagonal-Lattice Core for a World-Class Cold Neutron Source

Cold neutrons have kinetic energies less than 5 meV and wavelengths greater than 4 Α. They can be transported over tens of meters through super-reflecting neutron guides with minimal losses. Cold neutrons are used to investigate the structure of larger molecular systems such as biological materials, polymers and aggregates, due to their preferential interaction with light elements and general ignorance towards heavy ones. Intense beams of cold neutrons are obtained from slowing down a source of thermal energy neutrons - which may be from either a research reactor or spallation neutron source - through some cryogenic moderator such as liquid hydrogen or deuterium. The present reactor at the NIST Center for Neutron Research (NCNR) - NBSR - is such a cold neutron source (CNS) facility which provides cold neutron beams for over 2,000 scientists performing various experiments annually. Feasibility studies on a replacement reactor for the NBSR are underway at NCNR with the primary purpose of optimized cold neutron production. Low enriched uranium (LEU) fuel is required for the new reactor to conform to nuclear non-proliferation agreements. The low thermal power rate of 20 MW is taken as a priority with a fuel cycle length designated as 30 days. A horizontal split compact core with a large D{sub 2}O reflector tank is currently proposed and studied, with the expectation of achieving much better cold neutron performance than the present NIST reactor (NBSR). A preliminary core design has been completed using MCNP6 modeling and simulation. The physics performance characteristics of the proposed new core indicate that the new design is competitive with the most notable existing advanced cold neutron sources. In previous studies, only rectangular shaped fuel elements were considered because they have similar external dimensions as the NBSR fuel elements. However, from a compact core standpoint, a square lattice is not the most effective geometry for a tight configuration. Moreover, the previous studies also showed that the square lattice of the fuel elements left little room to accommodate vertical insertion blade-type control elements. As a result, all control blades had to reside in the D{sub 2}O reflector, which made the design cumbersome (in that case the control blades must penetrate the reflector tank) and neutronically uneconomical. In this summary, a preliminary feasibility study on a hexagonal core lattice is performed to render an alternative geometry for the new reactor (HEX core) to provide sufficient space for the control elements. The identical LEU fuel (U{sub 3}Si{sub 2}/Al) with U-235 enrichment 19.75% is used in the new design. The maximum thermal power and fuel management scheme remain the same as the previous investigations (three 30-day cycled batches for each batch of three fuel elements). The horizontal split compact core concept is also applied in the hexagonal lattice core design, with the objective of creating maximum thermal flux traps between the split core halves. A detailed description of the model for the hexagonal lattice core is presented in the following section. The HEX core design achieves a number of successes over the previous split-core design. Given that much of the motivation of this work was based on implementation of control blades into a concept which lacked them, it is notable that neutron economy was well-preserved in the process of achieving conservatively effective reactivity control; start-up k{sub eff} was in fact increased by 0.23% and peak thermal flux increased by ∼25%. A useful metric in determining the efficacy of resources towards creating an environment for the production of cold neutrons - dubbed the 'quality factor' (QF) - is the ratio of peak thermal neutron flux in a system to the total thermal power produced. Because HEX core's objectives are very focused in comparison to existing research reactors, it is fitting to pursue a design which out-performs all others in terms of some specific performance metric, namely this QF term. While HFIR remains the greatest cold neutron source in the world, it does so through use of HEU fuel (which will be replaced with LEU in the near future), and suffers a greater level of fast neutron contamination that is expected from the HEX design. The new core design achieves these successes due to the hexagonal lattice fuel arrangement, a 13.5% reduction in cladding mass, and a 13.1% reduction in fuel element volume. In spite of a 5.5% reduction in fuel mass, no compromises in reactor performance were noted. Provided the favorable characteristics shown of the control blade design, refueling intervals longer than the prescribed 30 days may be considered. It can be speculated that with these quantitative benefits, the overall capital and continuous costs of the HEX core design will be less than the previously proposed split-core concept.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental validation of an integrated modelling approach to neutron emission studies at JET

An integrated modelling methodology for the calculation of realistic plasma neutron sources for the JET tokamak has been developed. The computational chain comprises TRANSP plasma transport and DRESS neutron spectrum calculations, and their coupling to the MCNP neutron transport code, bridging plasma physics and neutronics. Here, we apply the developed methodology to the analysis of neutron emission properties of deuterium and helium plasmas at JET, and validate individual modelling steps against neutron diagnostic measurements. Two types of JET discharges are modelled—baseline-like and three-ion radio-frequency scenarios—due to their diversity in plasma heating, characteristics of the induced fast ion population, and the imprint of these on neutron emission properties. The neutron emission modelling results are quantitatively compared to the total neutron yield from fission chambers, neutron emissivity profiles from the neutron camera, neutron spectra from the time-of-flight spectrometer, and neutron activation measurements. The agreement between measured and calculated quantities is found to be satisfactory for all four diagnostic systems within the estimated experimental and computational uncertainties. Additionally, the effect of neutrons not originating from the dominating D(D, n) 3 He reactions is studied through modelling of triton burnup DT neutrons, and, in mixed D- 3 He plasmas, neutrons produced in the 9 Be(D, nγ) 10 B reaction on impurities. It is found that these reactions can contribute up to several percent to the total neutron yield and dominate the neutron activation of samples. Finally, the effect of MeV-range fast ions on the neutron activation of 115 In and 27 Al samples is measured and computationally validated.

integrated modelling↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-element Neutron Energy Spectrometer

In the area of nuclear radiological emergency response and preparedness applications, interest in neutron detection stems from several factors. Unlike gamma rays, which are abundant in nature and present serious difficulties in differentiating a signal from a changing background, whose values are location specific, neutrons are rare and nearly homogenous in spatial distribution. Additionally, many special nuclear materials (SNM) emit neutrons either directly by spontaneous fission or produce neutrons indirectly through (α, n) reactions in nearby light elements. Also of importance in detection scenarios is the fact that neutrons are not easily attenuated. Typically neutron detection is done by simply counting the low energy thermal neutrons by employing pressurized helium tubes operated at high voltages. Not much emphasis is put on determining the energy of the incident neutrons. However, critical information can be obtained by analyzing the neutron energy given off from radioactive materials. In the detection of an SNM, neutron energy information from an unknown source can be of paramount importance. We have modeled, designed, and prototyped multi-element neutron energy spectrometers that contain three to five pressurized helium tubes of dimensions 2" diam. x 10" in length. Each individual helium tube has a specific amount of high density plastic neutron moderators to slow down the incident energetic neutrons to an accurately estimated energy. A typical spectrometer is a set of moderator cylinders surrounding detectors that have high efficiency for detecting thermal neutrons. The larger the moderator, the higher the energy of incident neutrons for which the detector assembly has matched detection efficiency. If all the detectors are exposed to the same radiation field and the efficiency as a function of energy (response function) of each of the detectors is known, the neutron energy spectrum can be determined from the detector count rates. Monte Carlo simulation results of response function calculations for different arrays of helium tubes with varying amount of moderators will be shown. Experimental evidence of effectiveness of a set of moderated helium tubes to measure the hardness of the incident neutrons will be demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Multi-Step CADIS Parameter Sensitivity to Neutron Flux Spectrum in Shutdown Dose Rate Calculations

Shutdown dose rate (SDDR) analysis requires (a) a neutron transport calculation to estimate neutron flux fields, (b) an activation calculation to compute radionuclide inventories and associated photon sources, and (c) a photon transport calculation to estimate final dose rate. In some applications, accurate full-scale Monte Carlo (MC) SDDR simulations are needed for very large systems with massive amounts of shielding materials. For example, SDDR assessments are required throughout the biological shield (bio-shield) of the ITER experimental facility to evaluate the required waiting period after the shutdown of ITER and to identify the locations where human accessibility should be prohibited. The bio-shield is a large cylindrical concrete structure (30 m tall and 34 m in diameter) surrounding the very complex tokamak machine. Determining the effects on SDDR of important factors, such as the cross talk (interactions) between the different ports of ITER, is possible only through full-scale simulations that involve all the complex inner details of the ITER tokamak machine. These simulations are impractical because calculation of space- and energy-dependent neutron fluxes throughout the structural materials is needed to estimate the distribution of radioisotopes causing the SDDR. Determining a good importance function that can be used in biasing a neutron MC calculation for SDDR is complicated because it is difficult to explicitly express the SDDR response function, which depends on subsequent computational steps. The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid MC/deterministic method was developed to speed up the SDDR MC neutron transport calculation using an importance function that represents the neutron importance to the final SDDR. The MS-CADIS method uses the CADIS method, which has been Notice: This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC0500OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for the United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan). successfully used for more than a decade in radiation shielding applications to generate consistent source biasing and weight window (WW) variance reduction parameters to accelerate continuous-energy MC simulations. However, because MS-CADIS focuses on multi-step shielding calculations such as SDDR calculations, it develops an importance function for the initial radiation transport calculation (e.g., the neutron calculations in SDDR simulations) that represents the importance of particles to the final response of the overall simulation. To develop this importance function, the MS-CADIS method uses an adjoint calculation with a specific neutron adjoint source that represents the neutron's contribution to the final SDDR. Brute force calculation of the MS-CADIS neutron adjoint source requires a deterministic neutron transport calculation coupled with activation calculations in each element of the deterministic mesh. These calculations are needed to determine the MS-CADIS parameter for the neutron interactions that produce radioisotopes contributing to the SDDR. The MS-CADIS parameter is the microscopic cross section of the radioisotope-producing interaction, multiplied by the mass of this radioisotope existing at the end of the irradiation and decay scenario, and divided by the steady-state rate of the interaction. Because the activation calculations are performed for each radionuclide in each mesh element, implementation of the MS-CADIS method can be computationally expensive. However, these neutron transport and activation calculations are not needed if we assume that the radioisotopes are created due to single neutron interactions and their concentrations do not change as a result of burnup by neutron irradiation. The use of this approximation, which renders the MS-CADIS parameter independent of the neutron flux, seems reasonable in calculating the MS-CADIS importance function because this function is needed only to speed up the MC calculation, not to calculate the final SDDR. In this work, we investigate the validity of this approximation by investigating the behavior of the MS-CADIS parameter as a function of the neutron flux spectra in the Fusion Evaluated Nuclear Data Library (FENDL) Neutronics and Shielding Benchmark problem that contains representative isotopes and flux environments of fusion energy systems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutrons in Structural Biology: Challenges and Opportunities (Workshop Report)

Gaining a thorough understanding of biological systems requires building our knowledge about biological processes from the level of atoms and electrons, and up to whole organisms. Such comprehensive knowledge will allow for a predictive understanding of complex biological systems behavior. It will guide us in the design and development of novel therapeutics and vaccines to tackle existing health threats and to prepare for future pandemics, and it will provide information necessary to create new biomaterials and bio-inspired technologies through manipulation of biological macromolecules, their assemblies, single cells and even microorganisms. Reaching these goals will require a synergistic combination of multiple experimental techniques with molecular calculations and predictive simulations, and the design and development of new techniques and capabilities that bridge current knowledge and technology gaps. Neutron scattering provides unique information about the biomacromolecular structure and function and can play a major role in achieving these goals. A workshop was held to engage the scientific community in identifying pressing challenges in biochemistry, structural biology, enzymology and structure-guided drug design not solved with the current neutron scattering technologies or utilizing other structural biology techniques such as X-ray crystallography, NMR, and cryo-EM. The workshop brought together structural biology, biochemistry and computational experts, as well as early career researchers and students, creating a forum for discussing scientific advancement and collaboration. The workshop included a one-day satellite training workshop where graduate students and postdoctoral researchers were educated in the application of neutron crystallography and small-angle scattering in structural biology. Furthermore, the Instrument Scientific Advisory Board (ISAB) for the development of a macromolecular neutron diffractometer at ORNL’s Second Target Station was introduced at the workshop. The major outcome was that neutrons can provide atomic-level understanding of biomacromolecular structure, function and dynamics which is of paramount importance for addressing the identified challenges. Neutron crystallography, in particular, can resolve long-standing biochemical issues regarding enzyme function by delineating the underlying chemistry and can have a major impact on the design of small-molecule therapeutics, especially in combination with molecular computation (quantum chemistry and molecular dynamics simulations) and the emerging artificial intelligence (AI)-assisted drug design technologies. The unique properties of neutrons, including their high sensitivity to hydrogen and their non-destructive nature, make them ideal probes of biological matter. There is a palpable need in the scientific community to expand and enhance the impact of neutron sciences on biology. Neutron crystallography is the only structural biology method capable of determining positions of all hydrogen atoms in proteins, nucleic acids and their complexes at near-physiological temperatures and of unstable species at cryogenic temperatures. Moreover, neutron analysis is non-ionizing, non-destructive and does not perturb the structure or redox chemistry of active site metal centers and clusters in proteins, which can be invaluable for studying radiation-sensitive metalloprotein complexes. Further, neutron energies used in scattering applications are similar to atomic motions, permitting neutron spectroscopies to characterize the dynamics of biomacromolecules on the picosecond to microsecond timescales. The different sensitivities of neutrons to protium (H) and deuterium (D) isotopes of hydrogen allow enhanced visibility of specific parts of biological complexes through isotopic labeling. The impact of neutrons will be most powerful when neutron scattering is combined with complementary experimental techniques that use photons and electrons, and with high-performance computing. The interconnection and mutuality of the experimental and theoretical capabilities will drive discoveries in biological and health sciences to generate more complete picture of complex biological systems. The major limitation in the field of biological neutron crystallography has been signal-to-noise, demanding large samples that are difficult to produce for the majority of biomacromolecules and limiting the applicability of this technique in biological sciences. A neutron crystallography instrument at the Second Target Station will revolutionize biological science with neutrons by engaging a large scientific community of structural biologists, enabling successful neutron diffraction experiments from radically smaller biomacromolecular crystals, resolving unanswered biochemical questions, and meaningfully contributing to rational drug design. The meeting highlighted 10 grand challenges that will be addressed with this advanced capability over the next decade and beyond, and the recommendations required to help address them are given below.

59 BASIC BIOLOGICAL SCIENCES↗

2022 American Conference on Neutron Scattering (ACNS 2022)

The 11th American Conference on Neutron Scattering (ACNS 2022) will be held on June 5-9, 2022, in Boulder, CO. The Conference will provide essential information on the breadth and depth of current neutron-related research worldwide. Hosted by the Neutron Scattering Society of America, this year’s Conference will feature a combination of invited and contributed talks, poster sessions, and tutorials. Topics of the conference are: Advances in Neutron Facilities, Instrumentation and Software: Developments in sources, instrumentation, sample environments and control software. Hard Condensed Matter: Magnetism, correlated metals, quantum/topological materials, superconductors, ferroelectrics, multiferroics, glasses, and disorder phenomena. Submissions outlining examples of neutron scattering in industrial and engineering applications involving hard condensed matter systems are also encouraged. Soft Matter: Neutron studies of soft materials and related fields including in situ and in operando studies. Polymers, surfactants, emulsions, gels, nanoparticles, colloidal suspensions and more. Submissions of computational studies or applications of machine learning beneficial to neutron scattering experiments, as well as examples of neutron scattering in industrial and engineering applications are strongly encouraged. Biology, Biophysics and Biotechnology: Neutron studies of biological and biologically relevant systems. Proteins, bio membranes, biological assemblies, natural materials, nucleic acids, drug-delivery platforms and biomedical systems. Submissions of computational studies or applications of machine learning beneficial to biological neutron scattering experiments, as well as examples of neutron scattering in applied research involving biological systems, are strongly encouraged. Materials Chemistry and Energy: Neutron-based studies of functional materials and materials for energy applications. Examples include porous materials such as metal organic frameworks (MOFs), zeolites; phosphors; novel pigments; electrolytes; catalysts; ionic conductors/cathode materials; photovoltaic materials (hybrid perovskites); thermoelectrics; magnetocalorics/electrocalorics. Structural Materials and Engineering: Neutron scattering studies of materials and engineering processes including structural materials, concrete and metals, as well as engineering processes including combustion, corrosion, additive manufacturing, and others. Neutron Physics: Fundamental physical studies of the neutron and related areas. Emerging Applications in Neutron Scattering: Machine Learning and Data Science: Advances in computing power have contributed to rapidly evolving machine learning and data science fields that can be leveraged to the benefit of the neutron scattering community. The purpose of this session is to highlight recent advances in machine learning and data science and to serve as the foundation of a parallel data and computation track highlighting computation advances and applications in neutron scattering throughout the conference.

36 MATERIALS SCIENCE↗

The 14 MeV Neutron Irradiation Facility in MARIA Reactor

The MARIA reactor with thermal neutron flux density up to 3x10{sup 14} cm{sup -2} s{sup -1} and a number of vertical channels is well suited to material testing by thermal neutron treatment. Beside of that some fast neutron irradiation facilities are operated in MARIA reactor as well. One of them is thermal to 14 MeV neutron converter launched in 2014. It is especially devoted to fusion devices material testing irradiation. The ITER and DEMO research thermonuclear facilities are to be run using the deuterium - tritium fusion reaction. Fast neutrons (of energy approximately 14 MeV) resulting from the reaction are essential to carry away the released thermonuclear energy and to breed tritium. However, constructional materials of which thermonuclear reactors are to be built must be specially selected to survive intense fluxes of fast neutrons. Strong sources of 14 MeV neutrons are needed if research on resistance of candidate materials to such fluxes is to be carried out effectively. Nuclear reactor-based converter capable to convert thermal neutrons into 14 MeV fast neutrons may be used to that purpose. The converter based on two stage nuclear reaction on lithium-6 and deuterium compounds leading to 14 MeV neutron production. The reaction chain is begun by thermal neutron capture by lithium-6 nucleus resulted in triton release. The neutron and triton transport calculations have been therefore carried-out to estimate the thermal to 14 MeV neutron conversion efficiency and optimize converter construction. The usable irradiation space of ca. 60 cm{sup 3} has been obtained. The released energy have been calculated. Heat transport has been asses to ensure proper device cooling. A set of thermocouples has been installed in converter to monitor its temperature distribution on-line. Influence of converter on reactor operation has been studied. Safety analyses of steady states and transients have been done. Performed calculations and analyses allow designing the converter and formulate its operation limits and conditions. During first tested operation of the converter the 14 MeV neutron flux density was estimated to 10{sup 9} cm{sup -2} s{sup -1}, whereas fast fission neutrons inside converter achieved 10{sup 12} cm{sup -2} s{sup -1}, and thermal neutrons were reduced down to 109 cm-2 s-1. Taking into account the feasibility of almost incessant converter operation for a number of months, its arisen as one of the most powerful (in terms of fluence), currently available 14 MeV neutron source. Such a converter currently under operation in the MARIA reactor core will be presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts associated to each detector type will play a major role in the selection of the detector types used for the SINRD measurement. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗