Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NCSP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

IER 516: Zirconium Test Assembly CED Phase-1: Preliminary Experiment Design

IER-516, Zirconium Test Assembly (ZTA), is a campaign to design, execute, and document a series of high-fidelity critical benchmark experiments to validate current and future zirconium (Zr) and zirconium hydride (ZrH x ) nuclear data evaluations. ZTA is a collaborative project between Los Alamos National Laboratory and the French Autoritè de Sûretè Nuclèaire et de Radioprotection. The experiments will be fueled with highly enriched uranium (HEU), and utilize the Comet critical assembly machine at the National Criticality Experiments Research Center. A total of ten preliminary critical experiments were designed and optimized for Zr and ZrHx nuclear data sensitivities using the MCNP-Particle Swarm Optimization methodology in the thermal, epithermal, intermediate, and fast neutron energy regions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Increased Fidelity and Associated Computational cost of Detailed Integral Experiment Benchmarks [Slides]

It does not seem like the system is significantly more sensitive to diameters of components near the center of the core. Intuitively it is, but was not detectable with simulations run to a Monte Carlo k eff uncertainty of 0.00002. The system is more sensitive to heights of components near the center of the core. Most (if not all) Zeus style benchmarks have perturbed core component heights individually.

42 ENGINEERING↗

FSEN Reaction Rate Calculations in MCNP [Slides]

FSEN provides an opportunity to quickly calculate sensitivities to orthogonal measurements during integral experiments. Toy problem has been deployed to expand on verification of FSEN for reaction rate ratios. While there is decent agreement, further investigation must be done on multiplication’s impact on sensitivity vector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R -matrix analysis of n + nat Cl reactions up to 1.2 MeV

The R -matrix analysis of neutron-induced reactions for two stable chlorine isotopes ( 35 Cl and 37 Cl) was performed in the energy range of thermal up to 1.2 MeV. Starting from the repository of the ENDF/B-VIII.0 library and following recent measurement series, this work represents a significant improvement, particularly in the evaluation of the ( n , p ) reaction channel. The evaluation methodology used the R -matrix code SAMMY to generate a set of Reich–Moore resonance parameters for both stable chlorine isotopes. Consistent with recently measured 35 Cl( n , p ) data, the presented evaluation features a dramatic increase in the magnitude of the ( n , p ) reaction channel over the ENDF/B-VIII.1 nuclear data library and previous ENDF/B libraries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Fluence and Kerma Responses to Bare, Steel-Reflected, and Lucite-Reflected Steady-State Operations of the ORNL Health Physics Research Reactor

The experiments evaluated in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the Fast Burst Reactor. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. In this evaluation, a total of 12 experiments were evaluated (6 shield configurations and two responses). Six of them are considered acceptable as benchmark experiments and are thoroughly described: the measurands are bare, steel-shielded and Lucite-shielded neutron fluences and neutron KERMA responses to steady-state operations of the HPRR. It is important to mention that there is a general lack of information in the experimental methodology and neutron spectrum unfolding, and in some cases, unexpected and unexplained discrepancies between calculation and experiment. The HPRR’s unique characteristics were that it is a fast reactor, the use of a Lucite shield as the shielding material, and the use of the neutron fluence as the main benchmark measurand. There are no known, significant correlations between benchmarks in this evaluation and benchmarks in other evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Functional Expansion Tallies Using MCNP6 PTRAC Files [Slides]

Accuracy is vital for many radiation transport applications. Monte Carlo (MC) codes are the most accurate, but they are expensive for fine meshes. Functional Expansion Tallies (FETs) yield smoother, lower-variance results with far fewer degrees of freedom.

97 MATHEMATICS AND COMPUTING↗

A Python Tool for Reconstructing MCNP6 Particle Histories from an HDF5 PTRAC File [Slides]

A Python tool for converting the MCNP6 HDF5 PTRAC file to a list of Python trees is presented. The particle trees store MCNP6 simulated events for each history using parent-child relationships, which ensures that branching processes are accurately reproduced. A variety of post-processing scripts are presented and used in conjunction with the Python particle trees to make special tallies that are currently not available in the MCNP6 software and visualize the particle tracks.

97 MATHEMATICS AND COMPUTING↗

NCERC-CL TREAT Free Field Characterization Foil Reaction Rate Results

This report summarizes the analysis and preliminary MCNP reaction rate modeling of free field characterization measurements performed in the Transient Reaction Test Facility (TREAT) at Idaho National Laboratory (INL) between 12/18/2023 and 2/22/2024. A series of seven irradiations were performed using the Big-BUSTER (Broad Use Specimen Transient Experiment Rig) core configuration. Foil sets including 19.5% LEU-Zr alloy wire, S, Au, Fe, Ni, Co, Ti, and Zr were deployed in each irradiation. Identical foil sets were supplied to Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and INL. All foils were supplied by INL. Additional details on the experiment can be found in [2]. The foil sets were shipped to the National Criticality Experiments Research Center Counting Laboratory (NCERC-CL) branch at LANL (NCERC-CL NISC) and were received on 3/25/2024. Additional details on receipt and counting are reported in [3]. All reactor dosimetry measurements were performed in adherence to the ASTM standards applicable to reactor dosimetry. Measured reaction rates from Au, Co, Fe, Ni, and Ti are reported. Select reaction rate ratios and simulated reaction rates and ratios are discussed. Reaction rates for all measured reaction products were modeled with MCNP 6.3.1 and a TREAT input deck supplied by Edward Lum. Neutron emission estimates calculated using the measured and simulated reaction rates show excellent agreement between the three fast-threshold n-p reactions with the percent differences being < 9% between the three reactions. The capture reactions had poorer, but still reasonable, agreement with < 20% percent differences between the neutron emission estimates of the three capture reactions. The percent difference between the fast-threshold and capture reactions is ∼ 100% for each reaction. This supports the TREAT model is not accurately modeling the neutron spectrum and additional measurements are required to characterize TREAT and match measurements to simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AMPX Status 2024 [Slides]

This presentation focus on AMPX development for 2024 it also touches on ENDF/B-VIII.1. The slides touches on Thermal Neutron Scattering Library, AMPX Development Highlights, and Transport libraries for SCALE 7.0.0.

ENDF/B-VIII.1↗

AMPX Developments in 2024 [Slides]

The priority for AMPX development for FY2024 has been to support processing the ENDF/B-VIII.1 library. This includes the development to support Thermal Neutron Scattering Library, GNDS-2.1 support and AMPX maintenance, and transport libraries for SCALE 7.0.0.

Nuclear Criticality Safety Program (NCSP)↗

AMPX Support for GNDS-2.1 [Slides]

This presentation is a review of AMPX strategy for GNDS. It includes a summary of point data comparison, Summary of covariance data comparison, and a preview of SAMMY GNDS I/O and other development.

ENDF↗