Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

The AGN-201 Digital Twin: A test bed for remotely monitoring nuclear reactors

Research reactors have historically provided researchers and scientists with a means for testing and understanding the workings of nuclear phenomena. With the lack of new research reactors built in the past decades, it is important now more than ever to utilize and provide evidence for the usefulness of research reactors. Here, this work explores the use of the AGN-201 research reactor at Idaho State University as a test bed for developing a digital twin (named the AGN-201 DT) to realize remote monitoring for nuclear reactors. The goal of the AGN-201 DT is to monitor the AGN-201 reactor and detect when undeclared events take place to provide information for a monitoring agency. The AGN-201 DT was able to detect (without a priori knowledge) when multiple undeclared experiments were placed in the core using on-the-fly machine learning and reactor physics analysis. The AGN-201 reactor provided a test bed for developing, deploying, and testing a digital twin for monitoring nuclear reactors.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Insights from application of a hierarchical spatio-temporal model to an intensive urban black carbon monitoring dataset

Existing regulatory pollutant monitoring networks rely on a small number of centrally located measurement sites that are purposefully sited away from major emission sources. While informative of general air quality trends regionally, these networks often do not fully capture the local variability of air pollution exposure within a community. Recent technological advancements have reduced the cost of sensors, allowing air quality monitoring campaigns with high spatial resolution. The 100×100 black carbon (BC) monitoring network deployed 100 low-cost BC sensors across the 15 km 2 West Oakland, CA community for 100 days in the summer of 2017, producing a nearly continuous site-specific time series of BC concentrations which we aggregated to one-hour averages. Leveraging this dataset, we employed a hierarchical spatio-temporal model to accurately predict local spatio-temporal concentration patterns throughout West Oakland, at locations without monitors (average cross-validated hourly temporal R 2 =0.60). Using our model, we identified spatially varying temporal pollution patterns associated with small-scale geographic features and proximity to local sources. In a sub-sampling analysis, here we demonstrated that fine scale predictions of nearly comparable accuracy can be obtained with our modeling approach by using ~30% of the 100×100 BC network supplemented by a shorter-term high-density campaign.

54 ENVIRONMENTAL SCIENCES↗

An in-cell NMR study of monitoring stress-induced increase of cytosolic Ca{sup 2+} concentration in HeLa cells

Highlights: •We performed time-resolved NMR observations of calbindin D{sub 9k} in HeLa cells. •Stress-induced increase of cytosolic Ca{sup 2+} concentration was observed by in-cell NMR. •Calbindin D{sub 9k} showed the state-transition from Mg{sup 2+}- to Ca{sup 2+}-bound state in cells. •We provide a useful tool for in situ monitoring of the healthiness of the cells. -- Abstract: Recent developments in in-cell NMR techniques have allowed us to study proteins in detail inside living eukaryotic cells. The lifetime of in-cell NMR samples is however much shorter than that in culture media, presumably because of various stresses as well as the nutrient depletion in the anaerobic environment within the NMR tube. It is well known that Ca{sup 2+}-bursts occur in HeLa cells under various stresses, hence the cytosolic Ca{sup 2+} concentration can be regarded as a good indicator of the healthiness of cells in NMR tubes. In this study, aiming at monitoring the states of proteins resulting from the change of cytosolic Ca{sup 2+} concentration during experiments, human calbindin D{sub 9k} (P47M + C80) was used as the model protein and cultured HeLa cells as host cells. Time-resolved measurements of 2D {sup 1}H–{sup 15}N SOFAST–HMQC experiments of calbindin D{sub 9k} (P47M + C80) in HeLa cells showed time-dependent changes in the cross-peak patterns in the spectra. Comparison with in vitro assignments revealed that calbindin D{sub 9k} (P47M + C80) is initially in the Mg{sup 2+}-bound state, and then gradually converted to the Ca{sup 2+}-bound state. This conversion process initiates after NMR sample preparation. These results showed, for the first time, that cells inside the NMR tube were stressed, presumably because of cell precipitation, the lack of oxygen and nutrients, etc., thereby releasing Ca{sup 2+} into cytosol during the measurements. The results demonstrated that in-cell NMR can monitor the state transitions of stimulated cells through the observation of proteins involved in the intracellular signalling systems. Our method provides a very useful tool for in situ monitoring of the “healthiness” of the cells in various in-cell NMR studies.

60 APPLIED LIFE SCIENCES↗

Monitoring CO 2 Storage at Cranfield, Mississippi with Time-Lapse Offset VSP – Using Integration and Modeling to Reduce Uncertainty

A time-lapse Offset Vertical Seismic Profile (OVSP) data set was acquired as part of a subsurface monitoring program for geologic sequestration of CO 2 . The storage site at Cranfield, near Natchez, Mississippi, is part of a detailed area study (DAS) site for geologic carbon sequestration operated by the U.S. Dept. of Energy’s Southeast Regional Carbon Sequestration Partnership (SECARB). The DAS site includes three boreholes, an injection well and two monitoring wells. The project team selected the DAS site to examine CO 2 sequestration multiphase fluid flow and pressure at the interwell scale in a brine reservoir. The time-lapse (TL) OVSP was part of an integrated monitoring program that included well logs, crosswell seismic, electrical resistance tomography and 4D surface seismic. The goals of the OVSP were to detect the CO 2 induced change in seismic response, give information about the spatial distribution of CO 2 near the injection well and to help tie the high-resolution borehole monitoring to the 4D surface data. The VSP data were acquired in well CFU 31-F1, which is the ~3200 m deep CO 2 injection well at the DAS site. A preinjection survey was recorded in late 2009 with injection beginning in December 2009, and a post injection survey was conducted in Nov 2010 following injection of about 250 kT of CO 2 . The sensor array for both surveys was a 50-level, 3-component, Sercel MaxiWave system with 15 m (49 ft) spacing between levels. The source for both surveys was an accelerated weight drop, with different source trucks used for the two surveys. Consistent time-lapse processing was applied to both data sets. Time-lapse processing generated difference corridor stacks to investigate CO 2 induced reflection amplitude changes from each source point. Corridor stacks were used for amplitude analysis to maximize the signal-to-noise ratio (S/N) for each shot point. Spatial variation in reflectivity (used to ‘map’ the plume) was similar in magnitude to the corridor stacks but, due to relatively lower S/N, the results were less consistent and more sensitive to processing and therefore are not presented. We examined the overall time-lapse repeatability of the OVSP data using three methods, the NRMS and Predictability (Pred) measures of Kragh and Christie (2002) and the signal-to-distortion ratio (SDR) method of Cantillo (2011). Because time-lapse noise was comparable to the observed change, multiple methods were used to analyze data reliability. The reflections from the top and base reservoir were identified on the corridor stacks by correlation with a synthetic response generated from the well logs. A consistent change in the corridor stack amplitudes from pre- to post-CO 2 injection was found for both the top and base reservoir reflections on all ten shot locations analyzed. In addition to the well-log synthetic response, a finite-difference elastic wave propagation model was built based on rock/fluid properties obtained from well logs, with CO 2 induced changes guided by time-lapse crosswell seismic tomography (Ajo-Franklin, et al., 2013) acquired at the DAS site. Time-lapse seismic tomography indicated that two reservoir zones were affected by the flood. The modeling established that interpretation of the VSP trough and peak event amplitudes as reflectivity from the top and bottom of reservoir is appropriate even with possible tuning effects. Importantly, this top/base change gives confidence in an interpretation that these changes arise from within the reservoir, not from bounding lithology. The modeled time-lapse change and the observed field data change from 10 shotpoints are in agreement for both magnitude and polarity of amplitude change for top and base of reservoir. Therefore, we conclude the stored CO 2 has been successfully detected and, furthermore, the observed seismic reflection change can be applied to Cranfield’s 4D surface seismic for spatially delineating the CO 2 /brine interface.

54 ENVIRONMENTAL SCIENCES↗

Monitoring pipeline integrity of underground gas storage facilities using membrane-based electrochemical sensors

Effective monitoring of internal corrosion risk is crucial to ensuring the safety and longevity of natural gas pipeline infrastructure. While electrochemical sensors are commonly used to assess corrosion rates and corrosion indicators in aqueous fluids, they are rarely used in gas pipelines as these fluids lack the ionic conductivity needed for electrochemical measurements. The inclusion of ion-conductive membranes into electrochemical sensors can extend their functionality into humidified gas streams, providing critical information about emerging corrosion events that are common during withdrawal season in pipeline systems downstream from underground storage facilities. In parallel, new protective films, like those obtained through cold spray coating, are being developed to protect oil and gas pipelines and recover losses in structural integrity due to corrosion damage. Herein, we demonstrate how membrane-based electrochemical sensors (MBES) can be used to monitor fluid corrosivity by examining their response to changes in water content for a wide range of fluid compositions. It was found that MBES readings were highly sensitive to water content changes with membrane conductivity measurements varying from 10 –6 to 10 –1 S cm -1 , and corrosion rate measurements which varied from 10 –7 to 1 mm y -1 . Electron microscopy confirmed that the self-healing characteristics of metal coating films were still active despite their inclusion into an MBES probe. In conclusion, these findings indicate that membrane-based corrosion monitoring can be expanded to monitor coated-pipeline materials and provide early detection of emerging corrosion upsets relevant to underground gas storage facilities.

Electrochemical sensor↗

Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring

In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. - Highlights: Black-Right-Pointing-Triangle Lead carbonate concentrate. Black-Right-Pointing-Triangle Successful use of Pb isotopes in identifying sources of Pb arising from transport and shipping. Black-Right-Pointing-Triangle Use of Pb isotopes in legal proceedings and their use in cleanup of residences. Black-Right-Pointing-Triangle Use of Pb isotopes in cleanup of a residual 9000 tonnes of Pb carbonate and in ongoing monitoring.

54 ENVIRONMENTAL SCIENCES↗

Monitoring leaf phenology in moist tropical forests by applying a superpixel-based deep learning method to time-series images of tree canopies

Tropical leaf phenology-particularly its variability at the tree-crown scale-dominates the seasonality of carbon and water fluxes. However, given enormous species diversity, accurate means of monitoring leaf phenology in tropical forests is still lacking. Time series of the Green Chromatic Coordinate (GCC) metric derived from tower-based red-green-blue (RGB) phenocams have been widely used to monitor leaf phenology in temperate forests, but its application in the tropics remains problematic. To improve monitoring of tropical phenology, we explored the use of a deep learning model (i.e. superpixel-based Residual Networks 50, SP-ResNet50) to automatically differentiate leaves from non-leaves in phenocam images and to derive leaf fraction at the tree-crown scale. To evaluate our model, we used a year of data from six phenocams in two contrasting forests in Panama. Here, we first built a comprehensive library of leaf and non-leaf pixels across various acquisition times, exposure conditions and specific phenocams. We then divided this library into training and testing components. We evaluated the model at three levels: 1) superpixel level with a testing set, 2) crown level by comparing the model-derived leaf fractions with those derived using image-specific supervised classification, and 3) temporally using all daily images to assess the diurnal stability of the model-derived leaf fraction. Finally, we compared the model-derived leaf fraction phenology with leaf phenology derived from GCC. Our results show that: 1) the SP-ResNet50 model accurately differentiates leaves from non-leaves (overall accuracy of 93%) and is robust across all three levels of evaluations; 2) the model accurately quantifies leaf fraction phenology across tree-crowns and forest ecosystems; and 3) the combined use of leaf fraction and GCC helps infer the timing of leaf emergence, maturation and senescence, critical information for modeling photosynthetic seasonality of tropical forests. Collectively, this study offers an improved means for automated tropical phenology monitoring using phenocams.

54 ENVIRONMENTAL SCIENCES↗

Maximum Reasonable Radioxenon Releases from Medical Isotope Production Facilities and Their Effect on Monitoring Nuclear Explosions

Fission gases such as 133Xe are used extensively for monitoring the world for signs of nuclear testing in systems such as the International Monitoring System (IMS). These gases are also produced by nuclear reactors and by fission production of 99Mo for medical use. Recently, medical isotope production facilities have been identified as the major contributor to the background of radioactive xenon isotopes (radioxenon) in the atmosphere (Saey, et al., 2009). These releases pose a potential future problem for monitoring nuclear explosions if not addressed. As a starting point, a maximum acceptable daily xenon emission rate was calculated, that is both scientifically defendable as not adversely affecting the IMS, but also consistent with what is possible to achieve in an operational environment. This study concludes that an emission of 5×109 Bq/day from a medical isotope production facility would be both an acceptable upper limit from the perspective of minimal impact to monitoring stations, but also appears to be an achievable limit for large isotope producers.

07 ISOTOPE AND RADIATION SOURCES↗

Projected network performance for next generation aerosol monitoring systems

Aerosol monitoring for radioactivity is a mature and proven technology. However, by improving key specifications of aerosol monitoring equipment, more samples per day can be collected and analyzed with the same minimum detectable concentrations as current systems. This work models hypothetical releases of 140 Ba and 131 I over a range of magnitudes corresponding to the inventory produced from the fission of about 100 g to 1 kiloton TNT-equivalent of 235 U. The releases occur over an entire year to incorporate the natural variability in atmospheric transport. Sampling equipment located at the 79 locations for radionuclide stations identified in the Comprehensive Nuclear-Test-Ban Treaty (CTBT) for the International Monitoring System are used to determine the detections of the individual releases. Alternative collection schemes in next generation equipment that collect 2, 3, or 4 samples per day, rather than the current 1 sample per day, would result in detections in many more samples at more stations with detections for a given release level. The authors posit that next generation equipment will result in increased network resilience to outages and improved source-location capability for lower yield source releases. The application of dual-detector and coincidence measurements to these systems would significantly boost sensitivity for some isotopes and would further enhance the monitoring capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NuMI Primary Beam Monitoring

The position and intensity of the Fermilab Main Injector 128 GeV proton beam being delivered to NuMI have been monitored since the start of beam delivery in 2005. The results of this monitoring, and the monitoring of the performance of the instrumentation are discussed. Upgrades to and tests of improved SEM (multiwire Secondary Emission Monitors) are also discussed.

43 PARTICLE ACCELERATORS↗

Monitoring of human populations for early markers of cadmium toxicity: A review

Exposure of human populations to cadmium (Cd) from air, food and water may produce effects in organs such as the kidneys, liver, lungs, cardiovascular, immune and reproductive systems. Since Cd has been identified as a human carcinogen, biomarkers for early detection of susceptibility to cancer are of an importance to public health. The ability to document Cd exposure and uptake of this element through biological monitoring is a first step towards understanding its health effects. Interpretation and application of biological monitoring data for predicting human health outcomes require correlation with biological measures of organ system responses to the documented exposure. Essential to this understanding is the detection and linkage of early biological responses toxic effects in target cell populations. Fortunately, advances in cell biology have resulted in the development of pre-clinical biological markers (biomarkers) that demonstrate measurable and characteristic molecular changes in organ systems following chemical exposures that occur prior to the onset of overt clinical disease or development of cancer. Technical advances have rendered a number of these biomarkers practical for monitoring Cd-exposed human populations. Biomarkers will be increasingly important in relation to monitoring effects from the exposure to new Cd-based high technology materials. For example, cadmium-selenium (CdSe), nano-materials made from combinations of these elements have greatly altered cellular uptake characteristics due to particle size. These differences may greatly alter effects at the target cell level and hence risks for organ toxicities from such exposures. The value of validated biomarkers for early detection of systemic Cd-induced effects in humans cannot be underestimated due to the rapid expansion of nano-material technologies. This review will attempt to briefly summarize the applications, to date, of biomarker endpoints for assessing target organ system effects in humans and experimental systems from Cd exposure. Further, it will attempt to provide a prospective look at the possible future of biomarkers. The emphasis will be on the detection of early toxic effects from exposure to Cd in new products such as nano-materials and identification of populations at special risk for Cd toxicity.

60 APPLIED LIFE SCIENCES↗

Monitoring Cyp2b10 mRNA expression at cessation of 2-year carcinogenesis bioassay in mouse liver provides evidence for a carcinogenic mechanism devoid of human relevance: The dalcetrapib experience

Introduction: Dalcetrapib is a cholesteryl ester transfer protein (CETP) modulator in clinical assessment for cardiovascular outcome benefits. In compliance with regulatory requirements, dalcetrapib was evaluated in rodent 2-year carcinogenesis bioassays. In the mouse bioassay, male mice demonstrated increased liver weight and statistically increased incidences of hepatocellular adenoma/carcinoma. Hepatic cytochrome p450 (Cyp) 2b10 mRNA induction and increased Cyp2b10 enzyme activity signify activation of hepatic nuclear receptor constitutive androstane receptor (CAR), a widely established promoter of rodent-specific hepatic tumors. We therefore monitored hepatic Cyp2b10 mRNA and its enzyme activity in a subset of dalcetrapib-treated male mice from the bioassay. Methods: Liver samples were obtained from ∼ 1/3 of male mice from each dose group including vehicle-controls (mean and earliest study day of death 678 and 459 respectively). Quantitative real time PCR (qRT-PCR) was performed to determine Cyp2b10 mRNA expression and Cyp1a-, Cyp2b10- and Cyp3a-selective activities were monitored. Results: Cyp2b10 mRNA was strongly induced by dalcetrapib with an expected wide inter-individual variation (5–1421-fold). Group average fold-induction versus vehicle-controls showed a dose-related increase from 48-fold (250 mg/kg/day) to 160-fold (750 mg/kg/day), which declined slightly at 2000 mg/kg/day (97-fold). Cyp enzyme activities showed approximate doubling of total Cyp P450 content per milligram protein and a 9-fold increase in Cyp2b10-selective pentoxyresorufin O-dealkylase activity (750 mg/kg/day). Discussion: These data from hepatic Cyp2b10 monitoring are strongly suggestive of CAR activation by dalcetrapib, a mechanism devoid of relevance towards hepatocarcinogenesis in humans; results show feasibility of Cyp2b10 as a surrogate marker for this mechanism at cessation of a carcinogenesis bioassay. -- Highlights: ► Liver tumors were induced in male mice by dalcetrapib in a 2-y study (bioassay). ► Cyp2b10 induction typifies activation of nuclear receptor CAR in mouse liver. ► First report of hepatic Cyp2b10 monitoring at the end of a mouse bioassay. ► Cyp2b10 induction supports CAR activation by dalcetrapib in mouse bioassay. ► CAR activation is a mechanism of hepatic tumorigenesis of no relevance to humans.

60 APPLIED LIFE SCIENCES↗

In Situ Monitoring of Groundwater Contamination Using the Kalman Filter

This study presents a Kalman filter-based framework to establish a real-time in situ monitoring system for groundwater contamination based on in situ measurable water quality variables, such as specific conductance (SC) and pH. First, this framework uses principal component analysis (PCA) to identify correlations between the contaminant concentrations of interest and in situ measurable variables. It then applies the Kalman filter to estimate contaminant concentrations continuously and in real-time by coupling data-driven concentration-decay models with the previously identified data correlations. We demonstrate our approach with historical groundwater data from the Savannah River Site F-Area: We use SC and pH data to estimate tritium and uranium concentrations over time. Results show that the developed method can estimate these contaminant concentrations based on in situ measurable variables. The estimates remain reliable with less frequent or no direct measurements of the contaminant concentrations, while capturing the dynamics of short- and long-term contaminant concentration changes. In addition, we show that data mining, such as PCA, is useful to understand correlations in groundwater data and to design long-term monitoring systems. As a result, the developed in situ monitoring methodology is expected to improve long-term groundwater monitoring by continuously confirming the contaminant plume's stability and by providing an early warning system for unexpected changes in the plume's migration.

54 ENVIRONMENTAL SCIENCES↗

Spectrally monitoring the response of the biocrust moss Syntrichia caninervis to altered precipitation regimes

Climate change is expected to impact drylands worldwide by increasing temperatures and changing precipitation patterns. These effects have known feedbacks to the functional roles of dryland biological soil crust communities (biocrusts), which are expected to undergo significant climate-induced changes in community structure and function. Nevertheless, our ability to monitor the status and physiology of biocrusts with remote sensing is limited due to the heterogeneous nature of dryland landscapes and the desiccation tolerance of biocrusts, which leaves them frequently photosynthetically inactive and difficult to assess. To address this critical limitation, we subjected a dominant biocrust species Syntrichia caninervis to climate-induced stress in the form of small, frequent watering events, and spectrally monitored the dry mosses’ progression towards mortality. We found points of spectral sensitivity responding to experimentally-induced stress in desiccated mosses, indicating that spectral imaging is an effective tool to monitor photosynthetically inactive biocrusts. Comparing the Normalized Difference Vegetation Index (NDVI), the Simple Ratio (SR), and the Normalized Pigment Chlorophyll Index (NPCI), we found NDVI minimally effective at capturing stress in precipitation-stressed dry mosses, while the SR and NPCI were highly effective. Lastly, our results suggest the strong potential for utilizing spectroscopy and chlorophyll-derived indices to monitor biocrust ecophysiological status, even when biocrusts are dry, with important implications for improving our understanding of dryland functioning.

59 BASIC BIOLOGICAL SCIENCES↗

Hydra: An AI-Based Framework for Interpretable and Portable Data Quality Monitoring

Hydra is an advanced framework designed for training and managing AI models for near real time data quality monitoring at Jefferson Lab. Deployed in all four experimental halls, Hydra has analyzed over 2 million images and has extended its capabilities to offline monitoring and validation. Hydra utilizes computer vision to continually analyze sets of images of monitoring plots generated 24/7 during experiments. Generally, these sets of images are produced at a rate and quantity that is exceedingly difficult for shift crews to effectively monitor. Significant effort has been devoted to enhancing Hydra’s user interface, to ensure that it provides clear, actionable insights for shift workers and other users. Gradient Weighted Class Activation Maps (GradCAM) provide added interpretability, allowing users to visualize important regions of the image for classification. Hydra has been containerized to enable the creation of portable demos and seamless integration with container-based technologies such as Kubernetes and Docker. With the user interface enhancements and containerization, Hydra can be rapidly deployed for new use cases and experiments. This talk will describe the Hydra framework, its user interface and experience, and the challenges inherent in its design and deployment.

Britton, Thomas [Thomas Jefferson National Acceler↗

Computer Vision-Enabled Smart Traffic Monitoring for Sustainable Transportation Management

Transportation accounts for a significant portion of total global energy consumption. Excessive energy consumption usually occurs in urban traffic environments with congestion and travel delays. With the advancement of remote sensing and computer vision technologies, real-time traffic conditions can be monitored. Therefore, sustainable transportation management strategies can be developed to optimize the overall energy and environment performance and reduce congestion and emissions. This work presents a smart traffic monitoring system based on remote camera sensors. Real-time and historical traffic conditions at the US Department of Energy’s Oak Ridge National Laboratory (ORNL) were monitored and analyzed to develop optimal transportation management strategies for sustainability. Computer vision algorithms were developed and applied to process the real-time camera data to obtain complete traffic information across the ORNL campus. Weeks of historical data were collected and processed to analyze the traffic and identify bottlenecks. The proposed traffic monitoring and management approach can be applied and extended to benefit other campuses or urban areas.

Shao, Yunli↗

Electron {sup 83}Rb/{sup 83m}Kr Source for the Energy Scale Monitoring in the KATRIN Experiment

The KATRIN (KArlsruhe TRItium Neutrino) experiment investigates the endpoint region of the tritium {beta}-spectrum aiming for the sensitivity on the neutrino mass of 0.2 eV (90% C.L.). A spectrometer of the MAC-E filter (Magnetic Adiabatic Collimation with an Electrostatic filter) type will be used for a total time of at least 5 years. An unrecognized shift of the filtering potential would directly influence the resulting neutrino mass. To continuously monitor the filtering potential the high voltage (HV) will be simultaneously applied to an additional MAC-E filter spectrometer. In this monitor spectrometer suitable electron sources based on atomic/nuclear standards will be utilized. As one of such monitoring tools the solid {sup 83}Rb/{sup 83m}Kr source is intended. It provides conversion electrons from {sup 83m}Kr(t{sub 1/2} = 1.83 h) which is continuously generated by {sup 83}Rb(t{sub 1/2}{approx_equal}86 d). The Calibration and Monitoring task of the KATRIN project demands the long-term energy stability {Delta}E/E of the K-32 conversion electron line (E = 17.8 keV, {Gamma} = 2.7 eV) of {+-}1.6 ppm/month.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring bacterial biofilms with a microfluidic flow chip designed for imaging with white-light interferometry

There is a need for imaging and sensing instrumentation that can monitor transitions in biofilm structure in order to better understand biofilm development and emergent properties such as anti-microbial resistance. Herein, we expanded on our previously reported technique for measuring and monitoring the thickness and topology of live biofilms using white-light interferometry (WLI). A flow cell designed for WLI enabled the use of this non-disruptive imaging method for the capture of high resolution three-dimensional profile images of biofilm growth over time. The fine axial resolution (3 nm) and wide field of view (>1 mm by 1 mm) enabled detection of biofilm formation as early as three hours after inoculation of the flow cell with a live bacterial culture ( Pseudomonas fluorescens ). Additionally, WLI imaging facilitated monitoring the early stages of biofilm development and subtle variations in the structure of mature biofilms. Minimally-invasive imaging enabled monitoring of biofilm structure with surface metrology metrics (e.g., surface roughness). The system was used to observe a transition in biofilm structure that occurred in response to expsoure to a common antiseptic. In the future, WLI and the biofilm imaging cell described herein may be used to test the effectiveness of biofilm-specific therapies to combat common diseases associated with biofilm formation such as cystic fibrosis and periodontitis.

36 MATERIALS SCIENCE↗