Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LLNL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Outcomes of WPEC SG47 on "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation"

The Working Party on International Nuclear Data Evaluation Co-operation Subgroup 47 (WPECSG47) entitled "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation" was organised from 2019 and 2022 with the objectives to promote more systematic and wider use of shielding benchmark experiments in nuclear data (ND) and transport code validation and development, to provide feedback on the Shielding Integral Benchmark Archive and Database (SINBAD), and to promote its further development in coordination with the Expert Group on Physics of Reactor Systems (EGPRS). Altogether 9 meetings, the large majority (8) held remotely, were organised during the past 3 years to discuss the experience on the use of SINBAD, evaluation of new benchmarks and improvements to be contributed to the database which was severely neglected and lacking maintenance over the past ← 10+ years. Several proposals for new or updated benchmark evaluation were presented and discussed, such as FNG copper, LLNL pulsed spheres, CIAE iron sphere, KFK 1977 gamma measurements, Rez Fe sphere, ASPIS, ORNL Oxygen broomstick, TIARA and others. Complementing the database with new features was also discussed, for example providing the nuclear data sensitivity profiles more systematically would facilitate and better guide the use of data. Information on the geometry, (radiation source) and materials available in CAD format is expected to allow an easier and less error prone reference for computational model preparation and a potential input to CAD based workflows. Inputs for various transport codes and other benchmark data from participants have been shared via the NEA GitLab which could hopefully in the future evolve and form a bases for critically checked and validated benchmark data. Future development of SINBAD will be monitored by EGPRS and the newly created SINBAD Task Force.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How can a diverse set of integral and semi-integral measurements inform identification of discrepant nuclear data?

Nuclear data are used for a variety of applications, including criticality safety, reactor performance, and material safeguards. Despite the breadth of use-cases, the effective neutron multiplication factor, keff, of ICSBEP critical assemblies are primarily used for nuclear data validation; these are sensitive to specific energy regions and nuclides and are unable to uniquely constrain nuclear data. As a consequence, general-purpose nuclear data libraries, such as ENDF/B-VIII.0, may have deficiencies that, while not apparent in criticality applications, negatively impact other applications, such as non-destructive analysis of special nuclear material and neutron diagnosed subcritical experiments. Recent work by the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project developed a machine learning tool, RAFIEKI, which uses random forests and the SHAP metric to determine which nuclear data contribute most to predicted bias between measured and simulated responses (e.g. keff). This paper contrasts RAFIEKI analysis applied to keff only against RAFIEKI analysis with keff paired with either LLNL pulsed sphere measurements or subcritical benchmarks. Two examples show that a) including pulsed sphere measurements substantially increases 9Be nuclear data importance to bias between 2 and 15 MeV, and b) including subcritical benchmarks has the potential for disentangling compensating errors between 240Pu (n,el) and (n,il) cross-sections between 0.1 and 10 MeV. These results show that RAFIEKI analysis applied to response sets that include, but go beyond, keff can aid nuclear data evaluators in identifying issues in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

Extreme ultraviolet spectroscopy of low-Z ion plasmas for fusion applications

The study of impurities is a key component of magnetic fusion research as it is directly related to plasma properties and steady-state operation. Two of the most important low-Z impurities are carbon and oxygen. The appropriate method of diagnosing these ions in plasmas is extreme ultraviolet (EUV) spectroscopy. In this work the results of two different sets of experiments are considered, and the spectra in a spectral region from 40 to 300 A are analyzed. The first set of experiments was carried out at the Sustained Spheromak Physics Experiment at LLNL, where EUV spectra of oxygen ions were recorded. The second set of experiments was performed at the compact laser-plasma x-ray/EUV facility 'Sparky' at UNR. In particular, Mylar and Teflon slabs were used as targets to produce carbon, oxygen, and fluorine ions of different ionization stages. Nonlocal thermodynamic equilibrium kinetic models of O, F, and C were applied to identify the most diagnostically important spectral features of low-Z ions between 40 to 300 A and to provide plasma parameters for both sets of experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of x-ray Thomson scattering using picosecond K-α x-ray sources in the characterization of dense heated matter

Here, we present K-α x-ray Thomson scattering from shock compressed matter for use as a diagnostic in determining the temperature, density, and ionization state with picosecond resolution. The development of this source as a diagnostic as well as stringent requirements for successful K-α x-ray Thomson scattering are addressed. Here, the first elastic and inelastic scattering measurements on a medium size laser facility have been observed. We present scattering data from solid density carbon plasmas with >1X 10 5 photons in the elastic peak that validate the capability of single shot characterization of warm dense matter and the ability to use this scattering source at future free electron lasers and for fusion experiments at the National Ignition Facility (NIF), LLNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of x-ray radiation from a laser wakefield accelerator

A Laser Wakefield Accelerator (LWFA) is under development at Lawrence Livermore National Laboratory (LLNL) to produce electron bunches with GeV class energy and energy spreads of a few-percent. The interaction of a high power (200 TW), short pulse (50 fs) laser with neutral He gas can generate quasi-monoenergetic electron beams at energies up to 1 GeV [1]. The laser pulse can be self-guided over 1 cm overcoming the limitation of vacuum diffraction. X-ray betatron radiation is emitted while the accelerated electrons undergo oscillations in the wakefield electrostatic field. Here we present electron spectra measurements with a two screen spectrometer allowing to measure both the electron energy and the transverse deflection at the plasma exit. We have measured monoenergetic electron beams above 300 MeV. Furthermore a forward directed x-ray beam is observed. Preliminary measurements of the spectrum are in reasonable agreement with the calculated betatron spectrum in the synchrotron asymptotic limit using the measured electron beam parameters.

43 PARTICLE ACCELERATORS↗

Nuclear Resonance Fluorescence and Isotopic Mapping of Containers

National security programs have expressed interest in developing systems to isotopically map shipping containers, fuel assemblies, and waste barrels for various materials including special nuclear material (SNM). Current radiographic systems offer little more than an ambiguous density silhouette of a container's contents. In this paper we will present a system being developed at LLNL to isotopically map containers using the nuclear resonance fluorescence (NRF) method. Recent experimental measurements on NRF strengths in SNM are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PLANS FOR IGNITION EXPERIMENTS ON THE NATIONAL IGNITION FACILITY

The National Ignition Facility (NIF) is a 192-beam Nd-glass laser facility presently under construction at Lawrence Livermore National Laboratory (LLNL) in support of inertial confinement fusion (ICF) and high-energy-density (HED) science. NIF will produce 1.8 MJ, 500 TW of ultraviolet light, making it the world's largest and most powerful laser system. NIF will be the world's preeminent facility for the study of matter at extreme temperatures and densities and for producing and developing ICF. The ignition studies will be the next important step in developing inertial fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of High Intensity Thermal Positron Beams Using a 20 MeV Electron Linac

We present an update on the development of a positron-facility at Argonne National Laboratory. We discuss the advantages of using a low energy electron accelerator, present our latest results on slow positron production simulations, and describe our plans for further development of the facility. We have installed a new converter/moderator assembly that is appropriate for our electron energy and increases the yield about an order of magnitude. We have obtained a Penning trap and buncher from Lawrence Livermore National Laboratory (LLNL) that we plan to install. We have simulated the relative yields of thermalized positrons as a function of incident positron energy on the moderator. We use these data to calculate positron yields that we compare with our experimental data as well as with available literature data. We will discuss the new design of the next generation positron front end utilizing reflection moderation geometry.

43 PARTICLE ACCELERATORS↗

Experimental Results and Modeling of Low-Heat-Capacity TES Microcalorimeters for Soft-X-ray Spectroscopy

Transition-edge-sensor (TES) X-ray microcalorimeters have mostly been targeted at mid-band energies from 0.05-10 keV and high energies to above 100 keV. However, many other optimizations are possible. Here we present results from devices optimized for soft X-ray applications. For spectroscopy below 1 keV, the X-ray stopping power and heat capacity (C) of the TES itself are high enough that we can omit a separate absorber. The resulting devices have low C and the best-achievable energy resolution should be under 1 eV. We are interested in pursuing such devices primarily for astrophysical applications and laboratory astrophysics at LLNL's Electron-Beam Ion Trap. To this end, we have studied arrays in which 'bare' TESs are interspersed with broad-band pixels that have absorbers. By extending the absorbers to cover the area where the leads contact the low-energy pixels, we have eliminated a significant source of non-Gaussian detector response. The bare devices are in a different regime from our typical devices in that C is ten times lower and the conductance to the bath is four times lower. We have explored this regime through simultaneous fitting of noise and impedance data. These data cannot be fit by the simple model we employ to describe our typical broad-band devices. In this contribution we present X-ray spectra and the results from modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADMX Phase II : Relocation and Millikelvin Cooling

Low mass axions are an attractive candidate for making up dark matter. While there are several models for how the Axion couples with other matter, were they to be the majority of the local galactic dark matter halo, they would have a number density on the order of 10{sup 14} cm{sup -3}. The Axion Dark Matter eXperiment (ADMX) is a microwave cavity experiment searching for axion Dark Matter via the axion's electromagnetic coupling. While the original ADMX did not see evidence of axions, the experiment is planned to go through two phases of upgrades to expand its sensitivity and provide a definitive search for axion dark matter. The first phase established the use of a SQUID amplifier which can reduce the amplifier noise temperature to the 100 mK range. In the second phase we will first move the experiment from LLNL to CENPA at the University of Washington. Once the experiment has been moved successfully we will install a dilution refrigerator to cool the cavity to the 100 mK range thus increasing the sensititivity to the level required to scan the remainder of the allowed model space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Understanding of Enhanced Proton Energies from Laser-Cone Interactions

For the past ten years, the highest proton energies accelerated with high-intensity lasers was 58 MeV, observed in 2000 at the LLNL NOVA Petawatt laser, using flat foil targets. Recently, 67.5 MeV protons were observed in experiments at the Los Alamos National Laboratory (LANL) Trident laser, using one-fifth of the PW laser pulse energy, incident into novel conical targets. We present a focused study of new theoretical understanding of this measured enhancement from collisional Particle-in-Cell simulations, which shows that the hot electron temperature, number and maximum energy, responsible for the Target Normal Sheath Acceleration (TNSA) at the cone-top, are significantly increased when the laser grazes the cone wall. This is mainly due to the extraction of electrons from the cone wall by the laser electric field, and their boost in the forward direction by the vxB term of the Lorentz force. This result is in contrast to previous predictions of optical collection and wall-guiding of electrons in angled cones. This new wall-grazing mechanism offers the prospect to linearly increase the hot electron temperature, and thereby the TNSA proton energy, by extending the length over which the laser interacts in a grazing fashion in suitably optimized targets. This may allow achieving much higher proton energies for interesting future applications, with smaller, lower energy laser systems that allow for a high repetition rate.

43 PARTICLE ACCELERATORS↗

Simultaneous High-Resolution 2-Dimensional Spatial and 1-Dimensional Picosecond Streaked X-ray Pinhole Imaging

A Kentech x-ray streak camera was run at the LLNL Compact Multipulse Terawatt (COMET) laser to record simultaneous space- and time-resolved measurements of picosecond laser-produced plasmas. Four different x-ray energy channels were monitored using broad-band filters to record the time history of Cu targets heated at irradiances of 10{sup 16} - 10{sup 19} W/cm{sup 2}. Through the Cu filter channel, a time-resolution below 3ps was obtained. Additionally, an array of 10 {micro}m diameter pinholes was placed in front of the camera to produce multiple time-resolved x-ray images on the photocathode and time-integrated images on the phosphor with 10 and 15 times magnification, respectively, with spatial resolution of <13 {micro}m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray bang-time and fusion reaction history at picosecond resolution using RadOptic detection

We report recent progress in the development of RadOptic detectors, radiation to optical converters, that rely upon x-ray absorption induced modulation of the optical refractive index of a semiconductor sensor medium to amplitude modulate an optical probe beam. The sensor temporal response is determined by the dynamics of the electron-hole pair creation and subsequent relaxation in the sensor medium. Response times of a few ps have been demonstrated in a series of experiments conducted at the LLNL Jupiter Laser Facility (JLF). This technology will enable x-ray bang-time and fusion burn-history measurements with {approx} ps resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear photonics

With the planned new {gamma}-beam facilities like MEGa-ray at LLNL (USA) or ELI-NP at Bucharest (Romania) with 10{sup 13}{gamma}/s and a band width of {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -3}, a new era of {gamma} beams with energies up to 20MeV comes into operation, compared to the present world-leading HI{gamma}S facility at Duke University (USA) with 10{sup 8}{gamma}/s and {Delta}E{gamma}/E{gamma} Almost-Equal-To 3 Dot-Operator 10{sup -2}. In the long run even a seeded quantum FEL for {gamma} beams may become possible, with much higher brilliance and spectral flux. At the same time new exciting possibilities open up for focused {gamma} beams. Here we describe a new experiment at the {gamma} beam of the ILL reactor (Grenoble, France), where we observed for the first time that the index of refraction for {gamma} beams is determined by virtual pair creation. Using a combination of refractive and reflective optics, efficient monochromators for {gamma} beams are being developed. Thus, we have to optimize the total system: the {gamma}-beam facility, the {gamma}-beam optics and {gamma} detectors. We can trade {gamma} intensity for band width, going down to {Delta}E{gamma}/E{gamma} Almost-Equal-To 10{sup -6} and address individual nuclear levels. The term 'nuclear photonics' stresses the importance of nuclear applications. We can address with {gamma}-beams individual nuclear isotopes and not just elements like with X-ray beams. Compared to X rays, {gamma} beams can penetrate much deeper into big samples like radioactive waste barrels, motors or batteries. We can perform tomography and microscopy studies by focusing down to {mu}m resolution using Nuclear Resonance Fluorescence (NRF) for detection with eV resolution and high spatial resolution at the same time. We discuss the dominating M1 and E1 excitations like the scissors mode, two-phonon quadrupole octupole excitations, pygmy dipole excitations or giant dipole excitations under the new facet of applications. We find many new applications in biomedicine, green energy, radioactive waste management or homeland security. Also more brilliant secondary beams of neutrons and positrons can be produced.

43 PARTICLE ACCELERATORS↗

Integrated x-ray reflectivity measurements of elliptically curved pentaerythritol crystals

The elliptically curved pentaerythritol (PET) crystals used in the Supersnout 2 x-ray spectrometer on the National Ignition Facility at Lawrence Livermore National Laboratory have been calibrated photometrically in the range of 5.5-16 keV. The elliptical geometry provides broad spectral coverage and minimizes the degradation of spectral resolution due to the finite source size. The reflectivity curve of the crystals was measured using a x-ray line source. The integrated reflectivity (R{sub I}) and width of its curve ({Delta}{Theta}) were the measurements of major interest. The former gives the spectrometer throughput, and the latter gives the spectrometer resolving power. Both parameters are found to vary considerably with the radius of curvature of the crystal and with spectral energy. The results are attributed to an enhanced mosaic effect due to the increase in curvature. There are also contributions from the crystal cleaving and gluing processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerator driven gamma and fast neutron radiography test-bed at Lawrence Livermore National Laboratory

Accelerator driven fusion gammas and fast neutrons could provide unique radiography capabilities due to their ability to produce both high and low energy mono-energetic gammas and neutrons compared with broadband bremsstrahlung based x-ray sources. The possibility of simultaneously obtaining both gamma and neutron radiographs using one source could allow complex objects composed of a large range of low to high Z materials to be imaged. In this paper we review a 4 MV RFQ accelerator driven radiography test-bed at LLNL designed to study the physics involved in applying these dual output fusion reactions for radiography applications. First experimental neutron images from a carbon target are presented.

43 PARTICLE ACCELERATORS↗

Development of a dual MCP framing camera for high energy x-rays

Recently developed diagnostic techniques at LLNL require recording backlit images of extremely dense imploded plasmas using hard x-rays, and demand the detector to be sensitive to photons with energies higher than 50 keV [R. Tommasini et al., Phys. Phys. Plasmas 18, 056309 (2011); G. N. Hall et al., “AXIS: An instrument for imaging Compton radiographs using ARC on the NIF,” Rev. Sci. Instrum. (these proceedings)]. To increase the sensitivity in the high energy region, we propose to use a combination of two MCPs. The first MCP is operated in a low gain regime and works as a thick photocathode, and the second MCP works as a high gain electron multiplier. We tested the concept of this dual MCP configuration and succeeded in obtaining a detective quantum efficiency of 4.5% for 59 keV x-rays, 3 times larger than with a single plate of the thickness typically used in NIF framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗