Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Infrared”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Far-infrared observations of the Carina I and II H II regions

Far-infrared (35-175 microns) mapping and photometry are presented of the Carina I and II H II regions in the Carina Nebula (NGC 3372). The far-infrared source associated with Carina I has a half-power width of 2.7 arcmin and has no compact high-surface-brightness condensations, unlike many northern H II regions such as W51 or W49. The peak emission region is offset from the radio continuum peak in the direction of a dust lane to the west. It is proposed that the H II regions and far-IR source are both powered by the O-star cluster Tr 14 about 4 arcmin to the east. The H II region then represents an ionization front at the boundary of the dense cloud west of Tr 14, and the far-infrared emission is due to thermal radiation from the heated dust in the dark cloud. A similar model may also be applicable to the Carina II region.

Harvey, P. M.↗

Analysis techniques for two-dimensional infrared data

In order to evaluate infrared detection and remote sensing systems, it is necessary to know the characteristics of the observational environment. For both scanning and staring sensors, the spatial characteristics of the background may be more of a limitation to the performance of a remote sensor than system noise. This limitation is the so-called spatial clutter limit and may be important for systems design of many earth application and surveillance sensors. The data used in this study is two dimensional radiometric data obtained as part of the continuing NASA remote sensing programs. Typical data sources are the Landsat multi-spectral scanner (1.1 micrometers), the airborne heat capacity mapping radiometer (10.5 - 12.5 micrometers) and various infrared data sets acquired by low altitude aircraft. Techniques used for the statistical analysis of one dimensional infrared data, such as power spectral density (PSD), exceedance statistics, etc. are investigated for two dimensional applicability. Also treated are two dimensional extensions of these techniques (2D PSD, etc.), and special techniques developed for the analysis of 2D data.

Winter, E. M.↗

Development of the Equatorial Infrared Catalogue from satellite data

More than 40,000 infrared measurements of stellar sources have been obtained since November, 1976 during the ongoing process of compiling an Equatorial Infrared Catalogue. Because of the problem of eliminating spurious sources, which has affected earlier space surveys, an extensive effort is being made to verify the sources by means of (1) repetitive observations by satellite sensors, (2) cross correlation with a large data base developed from ground-based and space surveys at other wavelengths, and (3) investigation of a significant subset of the sources with a ground-based infrared telescope. As sources are verified, they are transferred from a working list to a screened preliminary version of the catalogue. The catalogue comprises the only survey of a significant area of the sky that has been accomplished (or is presently planned) with positional accuracies of a few arc seconds at a wavelength of not less than 2 microns.

Heinsheimer, T. F.↗

Compact H II regions in the far-infrared

Far-infrared (40-150 microns) observations of W51 (G49.5-0.4), K3-50, DR 21, NGC 7538, and W3(OH) are presented and discussed. At these wavelengths each source is dominated by a small bright component closely associated with a compact H II region. Their spectra can be explained as emission by dust at temperatures of 30-50 K. Some of the objects appear to be optically thick out to wavelengths of about 60 microns. Of the 10 source components in the five regions, at least four may be powered by pre-main-sequence stars. The far-infrared data are consistent with depletion of volatile components of the dust within compact H II regions, but do not clearly require destruction or expulsion of refractory grains. The bulk of the dust which emits primarily in the far-infrared must lie in a dense shell immediately outside the ionized zone. The sources are possible precursers to open clusters with stellar masses in the range from 1,000 to 10,000 solar masses.

Thronson, H. A., Jr.↗

A small helium-cooled infrared telescope for Spacelab 2

A helium cooled telescope of 15 cm aperture is being designed and constructed jointly by the University of Arizona, the Smithsonian Astrophysical Observatory and the Marshall Space Flight Center for high sensitivity infrared astronomical observations from Spacelab 2. A focal plane array of ten detectors provide a total field of view of 3 deg and cover the wavelength regions 4.5-8.5, 6-7, 9-16, 18-30 and 80-120 microns. A highly redundant all sky survey will be conducted by repeated scanning of the sky during many orbits of the spacecraft. High redundancy will allow discrimination among variable and constant celestial sources and several types of variable nearby sources. The principal astronomical result of the survey will be the absolute flux measurement of low surface brightness, large scale celestial infrared emissions but it will also extend existing IR sky surveys by a factor of 10 in point source sensitivity. The experiment will also make significant engineering measurements of contaminants in the Shuttle environment, test the technology of storage and utilization of large quantities of superfluid helium in space and test mechanical designs for future infrared telescopes for the Space Shuttle.

Gautier, T. N., III↗

An orbiting infrared interferometer to search for nonsolar planets

This paper proposes an orbiting infrared interferometer with its fringe null centered on a nearby star at a distance of say 10 parsecs. A large planet ('Jupiter') would have an angular separation from the star of about 0.5 arcsec. To have a fringe crest on the planet, a fringe period of 1.0 arcsec is needed and at 40 microns the required baseline is 8 m. Spinning the interferometer about the line of sight to the star results, even with pointing errors, in a relatively slowly varying but strongly suppressed stellar output and a more rapidly varying fringe-like planetary signal rich in higher harmonics. For pointing errors up to .050 arcsec the planet's fourth harmonic greatly exceeds that from the star, thereby relaxing interferometer pointing tolerances. Indeed, it appears that the limiting factor is zodiacal infrared background radiation and not the intense localized stellar flux which can effectively be eliminated by the fringe null of the spinning infrared interferometer.

Macphie, R. H.↗

Infrared spectra of the Orgueil /C-1/ chondrite and serpentine minerals

Infrared spectroscopy of the Orgueil C-1 chondrite and polymorphs of serpentine was performed in order to further define the mineralogy of Orgueil. Spectra of the meteorite and a synthetic serpentine (Mg3(Si2O5)(OH)4) were obtained in the regions from 1400 to 200 and from 4000 to 2500 kayers using a double beam infrared spectrometer. The spectra of Orgueil are found to be incompatible with those of the chrysotile, antigorite and lizardite polymorphs of serpentine, indicating a very low abundance of these minerals in the meteorite. It is suggested that chamosite or minerals related to chamosites may prove to be compatible with the compositional, structural and infrared properties of Orgueil.

Zaikowski, A.↗

The TIROS-N high resolution infrared radiation sounder

The high-resolution infrared radiation sounder (HIRS/2) was developed and flown on the Television and Infrared Observation Satellite, N Series (TIROS-N) as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow spectral channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel, and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic performance of the instrument in test is described. Early orbital information from the TIROS-N launched on October 13, 1978 are given and some observations on system quality are made.

Koenig, E. W.↗

Fourier emission infrared microspectrophotometer for surface analysis. I - Application to lubrication problems

A far-infrared interferometer was converted into an emission microspectrophotometer for surface analysis. To cover the mid-infrared as well as the far-infrared the Mylar beamsplitter was made replaceable by a germanium-coated salt plate, and the Moire fringe counting system used to locate the moveable Michelson mirror was improved to read 0.5 micron of mirror displacement. Digital electronics and a dedicated minicomputer were installed for data collection and processing. The most critical element for the recording of weak emission spectra from small areas was, however, a reflecting microscope objective and phase-locked signal detection with simultaneous referencing to a blackbody source. An application of the technique to lubrication problems is shown.

Lauer, J. L.↗

Infrared scanner concept verification test report

The test results from a concept verification test conducted to assess the use of an infrared scanner as a remote temperature sensing device for the space shuttle program are presented. The temperature and geometric resolution limits, atmospheric attenuation effects including conditions with fog and rain, and the problem of surface emissivity variations are included. It is concluded that the basic concept of using an infrared scanner to determine near freezing surface temperatures is feasible. The major problem identified is concerned with infrared reflections which result in significant errors if not controlled. Action taken to manage these errors result in design and operational constraints to control the viewing angle and surface emissivity.

Bachtel, F. D.↗

Atmospheric studies and applications with infrared heterodyne detection techniques

With the advent of stable, cw infrared lasers with moderate output power capabilities in the mid 1960's came the idea of using heterodyne detection, a mature radio frequency technique, in the infrared. This technique was first applied in radar and communications applications; however, it became apparent that infrared lasers and heterodyne detection techniques would be useful in a number of atmospheric measurement applications. The level to which these techniques are being put to use in field measurements is shown using two developed flight instruments as examples.

Menzies, R. T.↗

Pioneer Venus infrared radiometer - Design, implementation and preliminary results

The paper discusses the Pioneer Venus infrared radiometer design and operation. Its main function is to measure the thermal emission from the atmosphere at seven pressure levels above the Venus clouds, allowing a determination of the vertical temperature structure. In addition to the temperature sounding channels, there are two channels operating in the visible and near infrared to study the structure of the upper clouds, and a far infrared channel sensitive to water vapor in and above the clouds. The instrument can operate in four modes including a calibration sequence; by utilizing the spinning action of the spacecraft and short integration times, a substantial portion of the planet can be mapped within a 90 min data taking period centered about periapsis time. Temperature profiles retrieved during the course of the mission will clarify the dynamical processes in the upper atmosphere.

Martonchik, J. V.↗

Inference of the boundary layer structure over the oceans from satellite infrared measurements

Remote infrared spectral measurements in the 8-13 micron m window region, at a resolution about 3 cm/1, contain useful information about the water vapor and temperature stratification of the atmosphere within the first few kilometers above the water surface. Two pieces of information are retrieved from the spectral measurements: precipitable water vapor in the atmosphere, from the depth of the line structure between 8 and 9 micron m due to water vapor lines; and sea surface temperature, from the variation of brightness temperature between 11 and 13 micron m. Together, these two pieces of information can signify either the presence of a deep moist convective layer or the prevalence of stable conditions, such as caused by temperature inversions, which inhibit moist convection. A simple infrared radiative transfer model of the 9 micron m water vapor lines was developed to validate the method. With the help of this model and the Nimbus 4 infrared interferometer spectrometer data, a gross picture of the planetary boundary layer for different seasons over the global oceans is deduced. The important regions of the trade wind inversion and the intertropical convergence zones over all the oceans are clearly identified with this method. The derived information is in reasonable agreement with some observed climatological patterns over the oceans.

Prabhakara, C.↗

Infrared and radio observations of W51: Another Orion-KL at a distance of 7kpc

The bright infrared sources W51-IRS2 has at least three components with different physical and evolutionary properties. The spatial distribution and the near infrared spectra of the components in IRS2 are remarkably similar to, but more luminous than those found in Orion, where an H2 region of comparable linear size is also located close to a cluster of compact infrared sources. The characteristics of the nearby W51-NORTH H2O maser source, and the detection of 2 micro m H2 quadrupole emission in IRS2 indicate that the mass loss phenomena found in Orion-KL also exist in W51.

Genzel, R.↗

High angular resolution far-infrared observations of the W3 region

A 2 x 3 arcmin region surrounding the W3 cluster of near-infrared sources and compact H II regions has been mapped at 30, 50, and 100 microns with an angular resolution of about 30 arcsec. The data have been used to produce maps of the distribution of luminosity, color temperature, and opacity in the far-infrared which are used to analyze the properties and evolutionary states of the individual compact sources in the cluster and of the molecular cloud in which they are embedded. The total luminosity of the near-infrared source W3-IRS 5 is estimated on the basis of these observations to be 200,000 solar luminosities, and it is identified as a forming O star.

Werner, M. W.↗

Infrared Astronomical Satellite /IRAS/ Scientific Data Analysis System

The Infrared Astronomical Satellite (IRAS), to be launched in 1982, is discussed. It will systematically survey the entire sky over a large percentage of the infrared spectrum, in the wavelength region of 8 to 120 microns, at sensitivities a hundred times greater than previously achieved from high-altitude observatories, aircraft, balloons or sounding rockets. The Scientific Data Analysis System (SDAS), an off-line data processing facility, is examined. Its primary function is to produce a catalog of inertially fixed infrared-emitting point sources (mainly stars and galaxies) observed during the IRAS survey. Details for source detection and confirmation are given. It is estimated that the catalog will contain approximately a million objects having a brightness of 10 amtowatts per square centimeter or greater; 125,000 SDAS detections, if spurious events of signal-to-noise ratios greater than 2.5 are included, will be made every day.

Duxbury, J. H.↗

Far-infrared observations of the Cepheus OB3 molecular cloud

The molecular cloud accompanying the Cepheus OB3 association is observed in the infrared at wavelengths of 10-400 microns. Far-infrared emission at 55 microns and 125 microns from the two CO hot spots, Cep A and Cep B, is mapped with a resolution of approximately one arcmin. Cep A is also mapped at 400 microns with a resolution of approximately one arcmin, and both hot spots are searched for 20-micron sources. It is noted that the Cep A hot spot appears to be heated by energy sources internal to the molecular cloud. The dust temperatures are considered sufficient to explain the gas temperatures provided the dust heats the gas by collisions. In marked contrast, the Cep B region appears to be heated from outside the cloud, with the strongest far-infrared emission arising near the interface between the molecular cloud and the S155 H II region. It is thought that the gas heating rate through collisions with dust may be insufficient to achieve the gas temperature observed in Cep B.

Evans, N. J., II↗

Orbital operations with the Shuttle Infrared Telescope Facility /SIRTF/

The Shuttle Infrared Telescope Facility (SIRTF) is a cryogenically-cooled, 1-m-class telescope that will be operated from the Space Shuttle as an observatory for infrared astronomy. This paper discusses the scientific constraints on and the requirements for pointing and controlling SIRTF as well as several aspects of SIRTF orbital operations. The basic pointing requirement is for an rms stability of 0.25 arcsec, which is necessary to realize the full angular resolution of the 5-micron diffraction-limited SIRTF. Achieving this stability requires the use of hardware and software integral to SIRTF working interactively with the gyrostabilized Shuttle pointing-mount. The higher sensitivity of SIRTF, together with orbital and time constraints, puts a premium on rapid target acquisition and on efficient operational and observational procedures. Several possible acquisition modes are discussed, and the importance of source acquisition by maximizing the output of an infrared detector is emphasized.

Werner, M. W.↗