Synergistic effects of iodine and silver ions co-implanted in 6H–SiC
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
In this paper, in situ transmission electron microscopy investigations were carried out to study the microstructural evolution of ferritic/martensitic steel T91 under 1 MeV Krypton ion irradiation up to 4.2 x 10(15) ions/cm(2) at 573 K, 673 K, and 773 K. At 573 K, grown-in defects are strongly modified by black dot loops, and dislocation networks together with black-dot loops were observed after irradiation. At 673 K and 773 K, grown-in defects are only partially modified by dislocation loops; isolated loops and dislocation segments were commonly found after irradiation. Post irradiation examination indicates that at 4.2 x 1015 ions/cm(2), about 51% of the loops were a(0)/2 < 111 > type for the 673 K irradiation, and the dominant loop type was a(0)< 100 > for the 773 K irradiation. Finally, a dispersed barrier hardening model was employed to estimate the change in yield strength, and the calculated ion data were found to follow the similar trend as the existing neutron data with an offset of 100-150 MPa. (C) 2017 Elsevier B.V. All rights reserved.
Not Available
Here in this paper, the structure degradation of commercial Lithium-ion battery (LIB) graphite anodes with different cycling numbers and charge rates was investigated by focused ion beam (FIB) and scanning electron microscopy (SEM). The cross-section image of graphite anode by FIB milling shows that cracks, resulted in the volume expansion of graphite electrode during long-term cycling, were formed in parallel with the current collector. The crack occurs in the bulk of graphite particles near the lithium insertion surface, which might derive from the stress induced during lithiation and de-lithiation cycles. Subsequently, crack takes place along grain boundaries of the polycrystalline graphite, but only in the direction parallel with the current collector. Furthermore, fast charge graphite electrodes are more prone to form cracks since the tensile strength of graphite is more likely to be surpassed at higher charge rates. Therefore, for LIBs long-term or high charge rate applications, the tensile strength of graphite anode should be taken into account.
Abstract not provided
Anion exchange m em branes (AEM )are prom ising solid polym er electrolytes utilized in alkalifuelcells and electrochem icalenergy conversion devices.AEM s m ust ef ciently conductions w hile m aintaining chem icaland m echanicalstability undera range ofoperating conditions.The ionicnature ofAEM sleads to stiffand brittle m em branesunderdry conditions w hile athigher hydrations,w ater sorption causes signi cant softening and w eakening of the m em brane.In this w ork,a new polyethylene-b-poly(vinylbenzyltrim ethylam m onium ) polym er (70 kg/m ol) w as cast into large (300 cm 2),thin (127 3 m ) m em branes.These m em branes exhibited im proved elasticity over previously tested AEM s,m inim aldim ensional sw elling,and m oderate ionic conductivity (57 2 m S/cm at 50 °C,95% RH in the brom ide form ).Extensional testing indicated a 95% reduction in Young's m odulus betw een dry and hydrated states.Furtherinvestigation ofthe com plex m odulusasa function ofhydration,by dynam ic m echanical analysis,revealed a sharp decrease in m odulusbetw een dry and hydrated states.M echanicalsoftening w as reversible,but the location ofthe transition displayed hysteresis betw een hum idi cation and dehum idi cation.Conductivity increased after m em brane softening;suggesting bulk m echanicalpropertiescan identify thehydration levelrequired forim proved ion transport.Understanding the relationship betw een ion conduction and m echanical properties w illhelp guide AEM developm ent and identify operating conditions for sustained perform ance.
Explore the source record for details and available documents.
Lithium-ion batteries are widely used throughout the world for portable electronic devices and mobile phones and show great potential for more demanding applications like electric vehicles. Unfortunately, lithium-ion batteries still lack the required level of energy storage to completely meet the demands of such applications as electric vehicles. Among advanced materials being studied, silicon nanoparticles have demonstrated great potential as an anode material to replace the commonly used graphite. Silicon has been shown to have a high theoretical gravimetric capacity, approximately 4200 mA h/g, compared to only 372 mA h/g for graphite. Though silicon nanoparticles have remarkably high capacity, they suffer from rapid degradation with each cycle due to electrode volume expansion of approximately 400% during lithiation, placing a large strain on the material. With each cycle that strain creates cracks in the electrode particles and causes them to break down into smaller particles, which create void spaces between the particles and lead to poor contact as reflected in poor conductivity. In this review, we discuss exciting new research on silicon-based anodes conducted during the past couple of years. Besides stressing the importance of well-designed nanostructures of Si, we focus on optimization of the Si electrode and resulting performance enhancement by properly selecting binders and synergistically integrating them with various carbon materials during electrode design and fabrication. Importantly, although each improvement strategy has its own advantage, appropriate combination of them will yield much higher anode performance. We summarize the core issues in developing the silicon anode and effective strategies in yielding more promising results. (C) 2016 Elsevier Ltd. All rights reserved.
The cracking phenomenon of Ni-rich NMC (LiNixMnyCo1-x-yO2, x = 0.6) secondary particles is frequently discovered and believed to be one of critical reasons deteriorating the long-term cycling stability of NMC cathode in lithium ion batteries (LIBs). However, the initiation and evolution of those cracks is still controversial due to the limited quantification especially by in situ monitoring, leading to the challenge of identifying an efficient approach to inhibit the formation of the fractures during repeated cycling. Herein, the irreversible, anisotropic cycling lattice and mesoscale expansion/shrinkage of nano-grain during the first cycle, as revealed by in situ X-ray diffraction (XRD) and in situ atomic force microscopy (AFM), have been quantified and confirmed to be the dominant driving forces of microcracks initiation at the grain boundaries. These microcracks preferentially nucleates at the core region with random oriented nano-grains in early stage. The further growth and aggregation of microcracks into macrocrack eventually results in microfracture propagation radially outward to the periphery region with more uniform nano-grain orientation. This mesoscale nano-grain architecture controlled cracking process highlight the importance of predictive synthesis of cathode materials with controllable multiscale crystalline architecture for high-performance LIBs.
The ability to fabricate additively manufactured laser waveguides with sharp dopant concentration interfaces is limited by diffusion of the dopants at the temperatures required to fully densify the material. Compositional analysis of bilayer samples, where each layer was either undoped YAG or YAG doped with Yb, Lu, or Nd, were fabricated such that all combinations were available for testing. Samples were fabricated at both 1750°C and 1850°C to determine the diffusion behavior of each dopant alone and also in the presence of a second dopant. It was found that the experimental concentration profiles exhibited both intragranular (bulk) and grain boundary contributions, and thus fitting to a complementary error function equation required the use of two diffusion coefficients. Nd always diffused further along grain boundaries than the other dopants, due in part to its small segregation coefficient in YAG. It is shown that the presence of Nd as a counter dopant inhibits intragranular diffusion of other dopants while enhancing their grain boundary diffusion. All the observed trends were attributed to a combination of intragranular lattice strain due to: dopant ions replacing yttrium substitutionally, the relative driving forces for the segregation of dopant ions to grain boundaries, and the ability of one dopant to affect the diffusion of a different dopant in the other direction to maintain charge neutrality.
Direct recycling of lithium-ion is a promising method for manufacturing sustainability. It is more efficient than classical methods because it recovers the functional cathode particle without decomposition into substituent elements or dissolution and precipitation of the whole particle. This case study of cathode-healing™ applied to a battery recall demonstrates an industrial model for recycling of lithium-ion, be it consumer electronic or electric vehicle (EV) batteries. The comprehensive process includes extraction of electrolyte with carbon dioxide, industrial shredding, electrode harvesting, froth flotation, cathode-healing™ and finally, building new cells with recycled cathode and anode. The final products demonstrated useful capability in the first full cells made from direct recycled cathodes and anodes from an industrial source. The lessons learned on recycling the prototypical chemistry are preliminarily applied to EV relevant chemistries.
Ion mobility separations coupled to mass spectrometry (IM-MS) have received much attention for their ability to provide complementary structural information to solution-phase-based separations, as well as to aid in the identification of unknown compounds. While IM-MS is an increasingly powerful analytical technique, significant bottlenecks related to the resolution and sensitivity of measurements have kept it from becoming broadly applied for biological analyses. Structures for Lossless Ion Manipulations (SLIM)-based IM separations have successfully overcome these aforementioned bottlenecks, addressing issues associated with resolution and sensitivity in the omics, and potentially opening the door to broader application.
Mass spectrometry continues to develop as a valuable tool in the analysis of proteins and protein complexes. In protein complex mass spectrometry studies, surface-induced dissociation (SID) has been successfully applied in quadrupole time-of-flight (Q-TOF) instruments. SID provides structural information on non-covalent protein complexes that is complementary to other techniques. However, the mass resolution of Q-TOF instruments can limit the information that can be obtained for protein complexes by SID. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) provides ultrahigh resolution and ultrahigh mass accuracy measurements. In this study, an SID device was designed and successfully installed in a hybrid FT-ICR instrument in place of the standard gas collision cell. The SID-FT-ICR platform has been tested with several protein complex systems (homooligomers, a heterooligomer, and a protein-ligand complex, ranging from 53 kDa to 85 kDa), and the results are consistent with data previously acquired on Q-TOF platforms, matching predictions from known protein interface information. SID fragments with the same m/z but different charge states are well-resolved based on distinct spacing between adjacent isotope peaks, and the addition of metal cations and ligands can also be isotopically resolved with the ultrahigh mass resolution available in FT-ICR.
Lipids have been considered as key players in cell signaling and disease. Information on their location and distribution within a biological system, under varying conditions, is necessary to understand the contributions of different lipid species to an altered phenotype. Imaging mass spectrometry techniques, such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and matrix-assisted laser desorption/ionization (MALDI), are capable of revealing global lipid distributions in tissues in an untargeted fashion. Yet, to confidently identify the species present in a sample, orthogonal analyses like tandem MS (MS/MS) are often required. This can be accomplished by bulk sample analysis with liquid chromatography (LC)-MS/MS, which can provide confident lipid identifications, at the expense of losing location-specific information. Here, using planarian flatworms as a model system, we demonstrate that imaging gas cluster ion beam (GCIB)-ToF-SIMS has the unique capability to simultaneously detect, identify, and image lipid species with subcellular resolution in tissue sections. The parallel detection of both, intact lipids and their respective fragments, allows for unique identification of some species without the need of performing an additional orthogonal MS/MS analysis. This was accomplished by correlating intact lipid and associated fragment SIMS images. The lipid assignments, respective fragment identities, and locations gathered from ToF-SIMS data were confirmed via LC-MS/MS on lipid extracts and ultrahigh mass resolution MALDI-MS imaging. Together, these data show that the semidestructive nature of ToF-SIMS can be utilized advantageously to enable both confident molecular annotations and to determine the locations of species within a biological sample.
Na energy storage technology is strategically attractive for large scale applications such as grid energy storage. Here, we show that there is a clear relation between the Jahn-Teller activity of a transition metal ion at the end of charge and the mobility of Na in a cathode material. This is particularly important as mobility at the end of charge limits the capacity of current materials. Hence, by using this classical piece of physics in the battery world, it is possible to create higher capacity Na-cathode materials. Even more exciting is that the ideal element to impart this effect on cathodes is Fe, which is the least expensive of the transition metal oxides and can therefore enable low cost cathode materials.
Abstract not provided