Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hydraulic Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

PORFLOW modeling of Vadose zone flow and transport for the E-area intermediate level vault

In support of the E-Area Performance Assessment, a two-dimensional model of water flow and radionuclide transport through the E-Area Intermediate Level Vault (ILV) and local vadose zone has been developed using the PORFLOWTM software. The purpose of the model is to calculate flux to the water table for radionuclides eluted from the ILV during its operational life, the period of institutional control, and times following site closure. Results of model calculations will be used by a three-dimensional PORFLOW model of transport through the aquifer to determine radionuclide concentrations at a hypothetical 100 meter well and at the site boundary where contaminated groundwater could be assessed by members of the public following site closure. While newly developed, the model structure closely follows that used in the 2008 PA while incorporating a refined computational mesh, updated material properties for the vadose zone soil and vault concrete, revised infiltration rates, and new solid-liquid distribution coefficients. The model also addresses degradation of concrete hydraulic properties by blending soil and concrete water retention curves over a 500 year period. That is, the hydraulic properties of ILV concrete start out as fresh concrete at the time of site closure and degrade to soil properties over a 500 year time period. This approach has not been used previously in E-Area PA’s. The model has been used to calculate water flow through the ILV vadose zone and, on a trial basis, transport of a limited number of radionuclides from the waste region inside the ILV to the water table. Figure ES-1 provides a view of the model and an example of water flow after the concrete has substantially degraded. Figure dimensions are in centimeters. The red area in the left hand side figure is the waste disposal region within the ILV. Colored bands in the figures indicate different soil and concrete regions. Figure ES-2 shows a calculation of flux to the water table (mol/yr) for U-234 and its one-year half-life decay chain (U-234 → Th-230 → Ra-226 → Pb-210). Pb-210 flux is too small to show on the same scale used for Th-230 and Ra-226 in Figure ES-2. The model has also been used to make a preliminary evaluation of the release of tritium from TPBAR disposal containers that will be place in the ILV. A separately calculated tritium release rate as a function of time was used as a source in the PORFLOW model. The TPBAR disposal schedule and tritium release rate differ from the values used in the 2008 PA. Results from these initial trial runs are compared to calculations made for the 2008 PA ILV analysis. In brief, a new PORFLOW model of flow and transport through the ILV vadose zone has been developed and tested. The model is ready to be used for PA calculations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diffusiophoresis in narrow channel flows

We report that flows containing suspended colloidal particles and dissolved solutes are found in a multitude of natural and man-made systems including hydraulic fractures, water filtration systems and microfluidic devices, e.g. those designed for biological or medical applications. In these types of systems, unexpected particle dynamics such as rapid particle transport and focusing has been observed in the presence of local solute gradients due to the cooperating or competing effects of fluid advection and particle diffusiophoresis, the latter driven by local chemical gradients. We develop analytical expressions for the fluid, solute and particle dynamics in long, narrow channels due to the combined influence of pressure-driven channel flow with diffusiophoretic and diffusioosmotic effects. The results confirm a rapid particle focusing effect that can be controlled by manipulating the particle, solute and flow properties, as well as the channel’s geometry and surface chemistry. Thus, we propose a new approach for performing microfluidic zeta potentiometry, as well as techniques for sorting, concentrating and/or capturing particles based on their sizes or zeta potentials. Lastly, we demonstrate that diffusioosmotic effects can be used to pump fluid against a pressure gradient.

42 ENGINEERING↗

In-situ neutron radiography of pore-water movement in portland cement mortar under subzero temperature exposure: Insights from D 2 O-H 2 O systems

Neutron radiography was employed in this study to monitor real-time pore water movement in portland cement mortar exposed to subzero temperatures, providing novel insights into freeze-thaw (F-T) damage mechanisms. Deuterated water (D 2 O) was used to hydrate the cement in the mortar specimens, and the pore structure was saturated with water (H 2 O), allowing for a contrast that enabled detailed tracking of water movement predominantly in the pore structure. Furthermore, the mortar sample was placed on a chiller plate set to subzero temperatures, thereby providing a one-dimensional temperature gradient vertically in the sample. Neutron radiography revealed that unfrozen water migrated upward as the freezing front advanced, which can create hydraulic pressure within the mortar microstructure and may contribute to the initiation and propagation of microcracks during F-T cycles. Additional characterization of the concrete made with D 2 O showed a marked contrast to the samples made with H 2 O, including delayed hydration, diminished compressive strength, and greater porosity. Therefore, while mortar made with D 2 O allowed for greater neutron contrast to the pores filled with H 2 O, further study is required to produce mortars with similar properties to those made with H 2 O. In addition, further refinement is needed to the radiography experiment to allow for greater control of temperatures and potential quantification of the water concentration.

Air-void system↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Process Modeling of CO 2 Absorption with Monoethanolamine Aqueous Solutions Using Rotating Packed Beds

A first-principle process simulation model is presented for the chemical absorption of carbon dioxide (CO 2 ) with monoethanolamine (MEA) aqueous solutions using rotating packed beds (RPB). Built on a proven rate-based packed bed absorber model, the RPB model rigorously simulates the phase and chemical equilibria at the vapor-liquid interface, the heat and mass transfer across the gas and liquid films, the fast reactions between MEA and CO 2 in the liquid film, and the RPB hydraulics. Here, estimation of the mass transfer rate across the liquid film is central to accurate simulation of the CO 2 absorption process with MEA aqueous solutions. We show that the literature lab-scale RPB data for CO 2 removal efficiency can be satisfactorily correlated by introducing a correction factor for the effective packing surface area predicted by the Onda correlation. Given the validated RPB model, we further show that, among the gas-phase mass transfer coefficient, the liquid-phase mass transfer coefficient, and the reaction rate constant for the reaction between amine and CO 2 , the reaction rate constant is the controlling step with the highest potential to enhance the CO 2 absorption performance in RPB.

42 ENGINEERING↗

Application of NEAMS Multiphysics Framework for Species Tracking in Molten Salt Reactors

This report from Idaho National Laboratory (INL) summarizes the key modeling and simulation activities conducted under the Department of Energy (DOE) Molten Salt Reactor (MSR) Campaign during the Fiscal Year 2023 (FY23). The focus of the work was to leverage state-of-the-art modeling capabilities from the DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) codes to enable novel multiphysics and multiscale modeling and simulation of MSRs. Through collaboration with NEAMS code developers, advanced multiphysics analysis capabilities for MSR systems were demonstrated by coupling depletion, thermal-hydraulics, and thermochemistry into an innovative framework for chemical species transport in MSRs. As a result, the framework can track nuclides throughout their lifetimes in the core, from production (depletion) to advection throughout the salt volume (thermal-hydraulics) and off-gassing or precipitation outside of the salt (thermochemistry). This work supports the near-term deployment of MSRs by integrating the synergistic efforts between the DOE’s MSR Campaign and NEAMS program. The resulting framework will help better connect system design modelers with experimentalists to better understand and predict complex physical behaviors in MSRs. Researchers and MSR developers alike can now leverage these new modeling and simulation capabilities to perform novel analyses with applications including: • MSR dynamics during normal operational transients and accident scenarios • Off-gas system design and performance for fuel cycle and depletion analysis • Corrosion and active chemistry control for reactor component health and lifetime determination • Source term, decay heat and activity determination in accident scenarios • Special nuclear material accountancy and chemical forensic analysis for safeguards • Digital twin development of experiments and experimental reactor demonstrations • Measurement requirements for instrumentation and control design • Uncertainty and sensitivity analysis of missing data to inform future experimental data collection.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiphysics Design Optimization and Additive Manufacturing of Nuclear Components (Final CRADA Report - Executive Summary)

Westinghouse Electric Company (WEC) actively participated in the advancement of the nuclear fuel and reactor design space and requested the help of Oak Ridge National Laboratory (ORNL) in the creation of a new design tool set. This report details the creation of a collection of software tool sets that are linked together to collectively assist WEC design engineers in developing novel ideas outside the normal scope of traditional nuclear fuel and reactor design formulas. Specifically, Siemens HEEDS, a design space exploration and parametric optimization software, monitored and changed parameters in a collection of softwares to meet the team’s objective. The HEEDS parametric optimization method, SHERPA, was developed to control the Siemens NX CAD platform to adjust the native CAD of a hexahedral spacer grid. This new geometry can be used to execute a topological design optimization by the NX Topology software add-in. The resulting geometry is additively manufacturable. This topological optimization occurred twice—once on the spacer grid’s spring, and once on the dimple geometry. These new geometries were imported by Siemens’ STAR-CCM+, a multiphysics structural and fluid dynamic computational solver in which the spring geometry is deflected to match the rod insertion configuration. Along with the dimple geometry, this new deflected spring was used to complete a hydraulic assessment of a single-unit cell comprising one rod, one spring, and two dimples. The HEEDS SHERPA algorithm ranks the design based on the final mass of the unit cell and the hydraulic pressure drop performance. The ORNL team demonstrated the ability to use this software and provided engineering judgement to apply modern aerospace aerodynamic design. The effort has been focused on thinking outside the conventional design space and redesigning a spacer grid to perform beyond the WEC set objectives. Furthermore, the ORNL team also demonstrated that the HEEDS optimization routine can independently develop a design that meets the WEC design goals. Although these designs were at a low technology readiness level, their demonstration confirmed the team’s capability to create novel advanced nuclear concepts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Titan/Centaur T/C-1 post flight evaluation report

The first Titan/Centaur launch vehicle, TC-1, was launched from the Eastern Test Range Complex 41 at 09:48:01.46 hours Eastern Daylight Time on February 11, 1974. The vehicle carried a dynamic mass model of the Viking spacecraft and a SPHINX spacecraft, intended to study high voltage interactions in space. This launch was a Proof Flight of a vehicle con- figuration integrating the Air Force Titan booster and the NASA Centaur upper stage. It also was the first flight of the Centaur Standard Shroud developed for the Titan/Centaur. The countdown for the launch proceeded normally except for an additional 45 minute hold which was required to resolve a question concerning interpretation of booster hydraulic system data. The launch window opened at 09:03:00 hours Eastern Daylight Time. The vehicle was launched o on a flight azimuth of 105°. The Titan boost phase of flight was satisfactory. Solid Motor operation, Stage I and Stage II operation were normal. Venting of the Centaur Standard Shroud during ascent was successful and shroud separation and jettison was accomplished without incident. At the completion of the Titan Stage II burn, the Centaur successfully separated from the Titan. At this time, the Centaur main engines were sequenced through the first planned starting cycle but failed to achieve steady state operation. The vehicle flight control system, not sensing vehicle acceleration, commanded engine shutdown, and recycled, as programmed, through a back-up engine start attempt. The second engine start attempt was also unsuccessful. The flight control system then placed the vehicle in a coast-phase mode and the vehicle continued downrange in free fall. The vehicle was destroyed by Range Safety when the impact point was approximately 2200 nautical miles downrange, 12 minutes, 28.5 seconds after liftoff.

S. V. Szabo, Jr.↗

Protection and enrichment: how two different carbonaceous biofilm supports improve methane yield from encapsulated anaerobic microorganisms

Encapsulating anaerobic microorganisms allows for the separation of the solids retention time from the hydraulic retention time during anaerobic wastewater treatment. The harsh chemistries involved in the process of encapsulation can have adverse effects on microorganisms for anaerobic digestion, especially methanogens, and can lead to lower methane yields after encapsulation. Improving the survival and maintaining activity of anaerobic communities during encapsulation will likely be the key to improving methane yield. In this study, we investigated the encapsulation of biomass grown as biofilms on two carbonaceous materials, biochar and powdered activated carbon (PAC), to improve methane yield. Microorganisms grown as biofilms on biochar and PAC were encapsulated in polyethylene glycol (PEG) and incubated for 10 days. After 10 days, the unamended control capsules produced 81.6 ± 5.4 μmol of methane, while PAC-amended capsules produced 129.8 ± 1.9 μmol and biochar-amended capsules produced 432.96 ± 20.8 μmol methane, with the differences being statistically significant (p < 0.05). In biochar, a higher relative abundance of methanogens led to increased methane production capacity. The ratio of the methyl coenzyme M reductase (mcrA) genes to total 16S rRNA genes in the encapsulated biochar-supported biofilms was significantly higher than that in the encapsulated unsupported (p = 4.9 × 10 −5 ) and the PAC-supported biofilms (p = 0.012). Biochar-supported biofilms also had higher methane output per mcrA or 16S rRNA gene copy number. For the PAC, biofilms were protected from ammonium persulfate (APS), a powerful oxidant used in the encapsulation process. PAC removed 92% of dissolved APS, reducing exposure of the methanogens to this chemical. Unfortunately, this removal of APS compromised capsule stability, limiting the amount of PAC that could be added to the capsules. Furthermore, amendments that improve survival and activity of methanogens should be used in the capsules instead of those that protect methanogens by interfering with encapsulant polymerization chemistry.

Resource recovery↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 2: Component and system configuration screening analysis

The auxiliary power unit (APU) for the space shuttle is required to provide hydraulic and electrical power on board the booster and orbiter vehicles. Five systems and their associated components, which utilize hot gas turbines to supply horsepower at gearbox output pads, were studied. Hydrogen-oxygen and storable propellants were considered for the hot gas supply. All APU's were required to be self contained with respect to dissipating internally generated heat. These five systems were evaluated relative to a consistent criteria. The system supplied with high pressure gaseous hydrogen and oxygen was recommended as the best approach. It included a two-stage pressure-compounded partial-admission turbine, a propellant conditioning system with recuperation, a control system, and a gearbox. The gearbox output used was 240 HP. At the close of the study a 400 HP level was considered more appropriate for meeting the prime shuttle vehicle needs, and an in-depth analysis of the system at the 400 HP output level was recommended.

Burriss, W. L.↗

Preliminary design of an auxiliary power unit for the space shuttle: Component and system configuration screening analysis

The auxiliary power unit (APU) for the space shuttle is required to provide hydraulic and electrical power on board the booster and orbiter vehicles. Five systems and their associated components, which utilize hot gas turbines to supply horsepower at gearbox output pads, were studied. Hydrogen-oxygen and storable propellants were considered for the hot gas supply. All APU's were required to be self-contained with respect to dissipating internally generated heat. These five systems were evaluated relative to a consistent criteria. The system supplied with high pressure gaseous hydrogen and oxygen was recommended as the best approach. It included a two-stage pressure-compounded partial-admission turbine, a propellant conditioning system with recuperation, a control system, and a gearbox. The gearbox output used was 240 hp. At the close of the study a 400 hp level was considered more appropriate for meeting the prime shuttle vehicle needs, and an in-depth analysis of the system at the 400 hp output level was recommended.

Binsley, R. L.↗

MASS-REMOVAL AND MASS-FLUX-REDUCTION BEHAVIOR FOR IDEALIZED SOURCE ZONES WITH HYDRAULICALLY POORLY-ACCESSIBLE IMMISCIBLE LIQUID

A series of flow-cell experiments was conducted to investigate aqueous dissolution and mass-removal behavior for systems wherein immiscible liquid was non-uniformly distributed in physically heterogeneous source zones. The study focused specifically on characterizing the relationship between mass flux reduction and mass removal for systems for which immiscible liquid is poorly accessible to flowing water. Two idealized scenarios were examined, one wherein immiscible liquid at residual saturation exists within a lower-permeability unit residing in a higher-permeability matrix, and one wherein immiscible liquid at higher saturation (a pool) exists within a higher-permeability unit adjacent to a lower-permeability unit. The results showed that significant reductions in mass flux occurred at relatively moderate mass-removal fractions for all systems. Conversely, minimalmass flux reduction occurred until a relatively large fraction of mass (>80%) was removed for the control experiment, which was designed to exhibit ideal mass removal. In general, mass flux reduction was observed to follow an approximately one-to-one relationship with mass removal. Two methods for estimating mass-flux-reduction/mass-removal behavior, one based on system-indicator parameters (ganglia-to-pool ratio) and the other a simple mass-removal function, were used to evaluate the measured data. The results of this study illustrate the impact of poorly accessible immiscible liquid on mass-removal and mass-flux processes, and the difficulties posed for estimating mass-flux-reduction/mass-removal behavior.

58 GEOSCIENCES↗

Description of the 3 MW SWT-3 wind turbine at San Gorgonio Pass, California

The SWT-3 wind turbine, a microprocessor controlled three bladed variable speed upwind machine with a 3MW rating that is presently operational and undergoing system testing, is discussed. The tower, a rigid triangular truss configuration, is rotated about its vertical axis to position the wind turbine into the prevailing wind. The blades rotate at variable speed in order to maintain an optimum 6 to 1 tip speed ratio between cut in and fated wind velocity, thereby maximizing power extraction from the wind. Rotor variable speed is implemented by the use of a hydrostatic transmission consisting of fourteen fixed displacement pumps operating in conjunction with eighteen variable displacement motors. Full blade pitch with on-off hydraulic actuation is used to maintain 3MW of output power.

Rybak, S. C.↗

Methane foam performance evaluation in water-wet unconsolidated porous media: A systematic experimental investigation at elevated pressure and temperature conditions

In the petroleum industry, enhanced oil recovery (EOR) techniques employ foam extensively to establish conformance control in heterogeneous and fractured reservoirs in order to increase the sweep efficiency. In such applications, foam performance evaluation under complex subsurface conditions is pivotal for the effective and optimized deployment of foam treatment. However, there is a scarcity of hydrocarbon gas foam generation and evaluation studies that examine the relationships between foam performance and the critical foam parameters at high-pressure and high-temperature conditions. Here, this study aims at methodically investigating the effects of several foam parameters on methane foam performance in water-wet proppant packs under harsh operating conditions. This is in relation to the technical needs of hydrocarbon foam injection into hydraulically-induced, propped fractures in unconventional oil reservoirs. To this end, a state-of-the-art experimental foam generation apparatus was designed, fabricated, and commissioned. We performed a large number of foam flow experiments on proppant packs using methane gas and different foaming agents at 3500 psi and 115°C. Anionic and amphoteric surfactants were employed to probe the effect of their ionic nature on foam performance. Foam performance sensitivities to various foam generation parameters and operating conditions, such as surfactant concentration, gas fraction, total injection rate, operating pressure, salinity, and proppant pack length were investigated. To this end, steady-state pressure drops across the proppant packs during foam generation and foam's apparent viscosity were measured to quantify the foam performance of surfactants. The results were then analyzed to determine optimum values of the foam parameters and the interplay between these parameters are discussed here. The systematic results achieved from this work are in agreement with the trends available in the literature and provide new insights into complexities of in situ foam generation in water-wet, unconsolidated porous media at extreme reservoir conditions.

03 NATURAL GAS↗

Overview of Loop Heat Pipe Operation

Loop heat pipes (LHP's) are two-phase heat transfer devices that utilize the evaporation and condensation of a working fluid to transfer heat, and the capillary forces developed in the porous wicks to circulate the fluid. The LHP was first developed in the former Soviet Union in the early 1980s, about the same time that the capillary pumped loop (CPL) was developed in the United States. The LHP is known for its high pumping capability and robust operation mainly due to the use of fine-pored metal wicks and an integral evaporator/hydro-accumulator design. The LHP technology is rapidly gaining acceptance in aerospace community. It is the baseline design for thermal control of several spacecraft, including NASA's GLAS and Chemistry, ESA's ATLID, CNES' STENTOR, RKA's OBZOR, and several commercial satellites. Numerous LHP papers have been published since the mid-1980's. Most papers presented test results and discussions on certain specific aspects of the LHP operation. LHP's and CPL's show many similarities in their operating principles and performance characteristics. However, they also display significant differences in many aspects of their operation. Some of the LHP behaviors may seem strange or mysterious, even to experienced CPL practitioners. The main purpose of this paper is to present a systematic description of the operating principles and thermal-hydraulic behaviors of LHP'S. LHP operating principles will be given first, followed by a description of the thermal-hydraulics involved in LHP operation. Operating characteristics and important parameters affecting the LHP operation will then be described in detail. Peculiar behaviors of the LHP, including temperature hysteresis and temperature overshoot during start-up, will be explained. For simplicity, most discussions will focus upon LHP's with a single evaporator and a single condenser, but devices with multiple evaporators and condensers will also be discussed. Similarities and differences between LHP's and CPL's will be addressed throughout the paper whenever appropriate.

Ku, Jentung↗

Performance Validation and Scaling of a Capillary Membrane Solid-Liquid Separation System

Algaeventure Systems (AVS) has previously demonstrated an innovative technology for dewatering algae slurries that dramatically reduces energy consumption by utilizing surface physics and capillary action. Funded by a $6M ARPA-E award, transforming the original Harvesting, Dewatering and Drying (HDD) prototype machine into a commercially viable technology has required significant attention to material performance, integration of sensors and control systems, and especially addressing scaling issues that would allow processing extreme volumes of algal cultivation media/slurry. Decoupling the harvesting, dewatering and drying processes, and addressing the rate limiting steps for each of the individual steps has allowed for the development individual technologies that may be tailored to the specific needs of various cultivation systems. The primary performance metric used by AVS to assess the economic viability of its Solid-Liquid Separation (SLS) dewatering technology is algae mass production rate as a function of power consumption (cost), cake solids/moisture content, and solids capture efficiency. An associated secondary performance metric is algae mass loading rate which is dependent on hydraulic loading rate, area-specific hydraulic processing capacity (gpm/in2), filter:capillary belt contact area, and influent algae concentration. The system is capable of dewatering 4 g/L (0.4%) algae streams to solids concentrations up to 30% with capture efficiencies of 80+%, however mass production is highly dependent on average cell size (which determines filter mesh size and percent open area). This paper will present data detailing the scaling efforts to date. Characterization and performance data for novel membranes, as well as optimization of off-the-shelf filter materials will be examined. Third party validation from Ohio University on performance and operating cost, as well as design modification suggestions will be discussed. Extrapolation of current productivities will be used to suggest a design for integration into commercial-scale production.

09 BIOMASS FUELS↗

INDUCED MICROEARTHQUAKES AND SEISMICITY-PERMEABILITY RELATIONSHIPS IN FRACTURES

In the past several years, induced microearthquakes (MEQs) related to energy development projects have garnered public attention. Large-scale fluid injection in geoengineering activities, such as enhanced geothermal reservoir stimulation, geological storage of CO2, shale reservoir stimulation, and deep disposal of wastewater can generate significant fluid overpressures and induce microearthquakes by reactivating preexisting faults and fractures that are widely distributed throughout the upper crust. The monitoring of fluid-injection-induced microearthquakes can provide significant information (e.g., timing, special distribution, and moment magnitude) in evaluating reservoir development (e.g., fracture distribution and reservoir hydraulic conductivity evolution), in informing production strategies (e.g., accommodation of production wells), and in assessing the risks of fluid injection activities (e.g., caprock integrity of CO2 reservoir). The following questions are addressed in this study: (1) what are the mechanisms and implications of in-situ feedbacks (e.g., monitored fluid-injection-induced MEQs distribution, seismic moment magnitudes, and fracture behaviors) in geothermal stimulation? (2) What information can be derived from MEQs to inform geothermal reservoir stimulation strategies? (3) Are there any potential relationships between induced seismic or aseismic slip and permeability evolution of fractures in such unconventional reservoirs and caprocks? (4) What factors play an important role in controlling these relationships? These questions are addressed in the five individual chapters of this thesis.

58 GEOSCIENCES↗