Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High pressure instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Time-resolved particle image velocimetry

Time-resolved particle image velocimetry (TR-PIV) has become widespread in fluid dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well as spatial information, in contrast to conventional PIV offering only statistical ensembles of flow quantities. From these time series arise further analyses such as accelerometry, space-time correlations, frequency spectra of turbulence including spatial variability, and derivation of pressure fields and forces. The historical development of TR-PIV is chronicled, culminating in an assessment of the current state of technology in high-repetition-rate lasers and high-speed cameras. Commercialization of pulse-burst lasers has expanded TR-PIV into more flows, including the compressible regime, and has achieved MHz rates. Particle response times and peak locking during image interrogation require attention but generally are not impediments to success. Accuracy considerations are discussed, including the risks of noise and aliasing in spectral content. Oversampled TR-PIV measurements allow use of multi-frame image interrogation methods, which improve the precision of the correlation and raise the velocity dynamic range of PIV. In combination with volumetric methods and data assimilation, a full four-dimensional description of a flow is not only achievable but becoming standardized. Lastly, a survey of exemplary applications is followed by a few predictions concerning the future of TR-PIV.

47 OTHER INSTRUMENTATION↗

High Accuracy In-Flight Wavelength Calibration of Imaging Spectrometry Data

Accurate wavelength calibration of imaging spectrometer data is essential if proper atmospheric transmission corrections are to be made to obtain apparent surface reflectance. Accuracies of 0.1 nm are necessary for a 10 nm-sampling instrument in order to match the slopes of the deep atmospheric water vapor features that dominate the 0.7-2.3 micrometer regions. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is calibrated in the laboratory to determine the wavelength position and full-width-half-maximum (FWHM) response for each of the 224 channels. The accuracies are limited by the quality of the monochromator used as a source. The accuracies vary from plus or minus to plus or minus 1.5 nm depending on the wavelength region, in general decreasing with increasing wavelength. Green et al. make corrections to the wavelength calibrations by using the known positions of 14 atmospheric absorption features throughout the 0.4-2.5 micrometer wavelength region. These features, having varying width and intensity, were matched to the MODTRAN model with a non-linear least squares fitting algorithm. A complete calibration was developed for all 224 channels by interpolation. Instrument calibration cannot be assumed to be stable to 0.1 nm over a flight season given the rigors of thermal cycling and launch and landing loads. The upcoming sensor HYDICE will require a means for in-flight spectral calibration of each scene because the calibration is both temperature and pressure sensitive. In addition, any sensor using a two-dimensional array has the potential for systematic wavelength shifts as a function of cross-track position, commonly called 'smile'. Therefore, a rapid means for calibrating complete images will be required. The following describes a method for determining instrument wavelength calibration using atmospheric absorption features that is efficient enough to be used for entire images on workstations. This study shows the effect of the surface reflectance on the calibration accuracy and the calibration history for the AVIRIS B spectrometer over the 1992 flight season.

Goetz, Alexander F. H.↗

Simulating Virtual Terminal Area Weather Data Bases for Use in the Wake Vortex Avoidance System (Wake VAS) Prediction Algorithm

During the research project, sounding datasets were generated for the region surrounding 9 major airports, including Dallas, TX, Boston, MA, New York, NY, Chicago, IL, St. Louis, MO, Atlanta, GA, Miami, FL, San Francico, CA, and Los Angeles, CA. The numerical simulation of winter and summer environments during which no instrument flight rule impact was occurring at these 9 terminals was performed using the most contemporary version of the Terminal Area PBL Prediction System (TAPPS) model nested from 36 km to 6 km to 1 km horizontal resolution and very detailed vertical resolution in the planetary boundary layer. The soundings from the 1 km model were archived at 30 minute time intervals for a 24 hour period and the vertical dependent variables as well as derived quantities, i.e., 3-dimensional wind components, temperatures, pressures, mixing ratios, turbulence kinetic energy and eddy dissipation rates were then interpolated to 5 m vertical resolution up to 1000 m elevation above ground level. After partial validation against field experiment datasets for Dallas as well as larger scale and much coarser resolution observations at the other 8 airports, these sounding datasets were sent to NASA for use in the Virtual Air Space and Modeling program. The application of these datasets being to determine representative airport weather environments to diagnose the response of simulated wake vortices to realistic atmospheric environments. These virtual datasets are based on large scale observed atmospheric initial conditions that are dynamically interpolated in space and time. The 1 km nested-grid simulated datasets providing a very coarse and highly smoothed representation of airport environment meteorological conditions. Details concerning the airport surface forcing are virtually absent from these simulated datasets although the observed background atmospheric processes have been compared to the simulated fields and the fields were found to accurately replicate the flows surrounding the airport where coarse verification data were available as well as where airport scale datasets were available.

Kaplan, Michael L.↗

Design of Experiments for Both Experimental and Analytical Study of Exhaust Plume Effects on Sonic Boom

Computational fluid dynamics (CFD) analysis has been performed to study the plume effects on sonic boom signature for isolated nozzle configurations. The objectives of these analyses were to provide comparison to past work using modern CFD analysis tools, to investigate the differences of high aspect ratio nozzles to circular (axisymmetric) nozzles, and to report the effects of under expanded nozzle operation on boom signature. CFD analysis was used to address the plume effects on sonic boom signature from a baseline exhaust nozzle. Nearfield pressure signatures were collected for nozzle pressure ratios (NPRs) between 6 and 10. A computer code was used to extrapolate these signatures to a ground-observed sonic boom N-wave. Trends show that there is a reduction in sonic boom N-wave signature as NPR is increased from 6 to 10. As low boom designs are developed and improved, there will be a need for understanding the interaction between the aircraft boat tail shocks and the exhaust nozzle plume. These CFD analyses will provide a baseline study for future analysis efforts. For further study, a design of experiments has been conducted to develop a hybrid method where both CFD and small scale wind tunnel testing will validate the observed trends. The CFD and testing will be used to screen a number of factors which are important to low boom propulsion integration, including boat tail angle, nozzle geometry, and the effect of spacing and stagger on nozzle pairs. To design the wind tunnel experiment, CFD was instrumental in developing a model which would provide adequate space to observe the nozzle and boat tail shock structure without interference from the wind tunnel walls.

Castner, Raymond S.↗

CFD Simulations of the IHF Arc-Jet Flow: 9-Inch Nozzle, Flow Surveys, LEAF Wedge Calibration Data

This paper reports computational analyses and flow characterization studies in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using a wedge model placed in a free jet downstream of new 9-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Both the nozzle and wedge model were specifically designed for testing in the new Laser-Enhanced Arc-jet Facility. Data were obtained using stagnation calorimeters and wedge models placed downstream of the nozzle exit. Two instrumented wedge calibration plates were used: one water-cooled and the other RCG-coated tile plate. Experimental surveys of arc-jet test flow with pitot and heat flux probes were also performed at three arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. By taking into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields, these simulations approximately reproduce the probe survey data and predict the wedge model surface pressure and heat flux measurements.

Arc-jets↗

Correlation of forebody pressures and aircraft yawing moments on the X-29A aircraft at high angles of attack

In-flight pressure distributions at four fuselage stations on the forebody of the X-29A aircraft have been reported at angles of attack from 15 to 66 deg and at Mach numbers from 0.22 to 0.60. At angles of attack of 20 deg and higher, vortices shed from the nose strake caused suction peaks in the pressure distributions that generally increased in magnitude with angle of attack. Above 30 deg-angle of attack, the forebody pressure distributions became asymmetrical at the most forward station, while they remained nearly symmetrical until 50 to 55 deg-angle of attack for the aft stations. Between 59 to 66 deg-angle of attack, the asymmetry of the pressure distributions changed direction. Yawing moments for the forebody alone were obtained by integrating the forebody pressure distributions. At 45 deg-angle of attack, the aircraft yaws to the right and at 50 deg and higher, the aircraft yaws to the left. The forebody yawing moments correlated well with the aircraft left yawing moment at an angle of attack of 50 deg or higher. At a 45 deg-angle of attack, the forebody yawing moments did not correlate well with the aircraft yawing moment, but it is suggested that this was due to asymmetric pressures on the cockpit region of the fuselage which was not instrumented. The forebody was also shown to provide a positive component of directional stability of the aircraft at angles of attack of 25 deg or higher. A Mach number effect was noted at angles of attack of 30 deg or higher at the station where the nose strake was present. At this station, the suction peaks in the pressure distributions at the highest Mach number were reduced and much more symmetrical as compared to the lower Mach number pressure distributions.

Fisher, David F.↗

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable of supporting the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid on The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121 deg Celcius was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The test provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has be carried out. The pressure decay with time has been indicated.

Scialdone, John J.↗

An experimental, theoretical, and kinetic modeling study of post-flame oxidation of ammonia

The post -flame oxidation rate of ammonia was investigated in a novel atmospheric pressure flow reactor at temperatures of 1280 ± 16 K and as a function of residence time and mixture composition (1-10% O 2 , dry and moist). The experimental results, as well as selected data from literature, were analyzed using an updated detailed chemical kinetic model. The medium temperature, very lean conditions enhance the importance of reactions of the nitroxyl (HNO) intermediate. High-level theory was used to calculate the rate constant for HNO + NH 2 , indicating that this step is significantly faster than values used in literature. Furthermore, a trajectory based approach was used to determine collision efficiencies for selected bath gases for HNO + M. The experimental results show that the NH 3 oxidation rate increases with temperature and O 2 concentration, while the presence of water vapor slightly inhibits reaction. Formation of NO and N 2 O was strongly promoted at higher levels of O 2 . Modeling results agreed well with the measurements, except at the lowest level of O 2 . The predicted oxidation rate of NH 3 was shown to result from a delicate balance between chain branching and terminating steps involving NH 2 , H 2 NO, and HNO. Recent theoretical work on reactions of these species by Klippenstein and coworkers and Stagni et al. was instrumental in improving modeling predictions. After initiation, NO reached a pseudo -steady-state level, where the pathways to NO were largely balanced by the NH 2 + NO reaction. Nitric oxide was partly oxidized to NO 2 , with the NH 2 + NO 2 reaction responsible for most of the N 2 O formation. Novelty and significance statement: This study provides the first detailed kinetic analysis of the lean postflame oxidation of ammonia, based on time -resolved flow reactor data in a novel reactor. In addition to the post -flame oxidation rate of ammonia, data for formation of NO and N 2 O were compared with modeling predictions. The medium temperature, very lean conditions enhance the importance of reactions of the HNO and H 2 NO intermediates. Inclusion in the model of results from recent high-level theoretical work, including present calculations for HNO + NH 2 and HNO + M, was crucial for capturing the observed behavior. It is argued that the post -initiation steady-state NH 3 oxidation rates constitute important data for model validation, along with ignition delays and laminar flame speeds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sizing and Selection of Pressure Relief Valves for High-Pressure Thermal–Hydraulic Systems

This study covers the critical concerns related to the sizing, selection, installation, maintenance, and testing of pressure safety valves (PSVs). The aim is to ensure the safety of pressurized systems, hydrostatic transmission systems, and hydraulic plants, including process plants, thermal power plants, and nuclear reactor systems. PSVs are devices that ensure the safety and reliability of pressurized vessels, lines, and systems during overpressure events. The task of selecting which PSV features are of greatest value for a specific purpose is complex—especially in the design of a high-pressure experimental thermal–hydraulic facility for hydrostatic and transient testing of the reactor system—when the systems are in the design and development phases and require qualification and demonstration to prove that they have reached a given level of technological readiness. The present study highlights the required steps for users to follow the associated rules, guidelines, and recommendations. As a part of this research, case studies are presented to help readers better understand the applicable strategy and standards. A discussion and a review of PSV performance degradation and failure are summarized to provide a better understanding of varied process applications and conditions, including fluid flow dynamics, boundary-layer formation and pressure drops, gas bubble formation and collapse, geometric configurations, inlet/outlet piping, abrupt pressure fluctuations, and acoustic resonance. Moreover, this study discusses the servicing and testing of PSVs in a multiphase pressurized system. Overall, it provides a basic overview of how PSVs ensure the safety of pressurized systems, supported by case studies and industrial practices.

02 PETROLEUM↗

Preventing Damaging Pressure Gradients at the Walls of an Inflatable Space System

An inflatable structural system to deploy a space system such as a solar shield, an antenna or another similar instrument, requires a stiffening element after it is extended by the inflated gas pressure. The stiffening element has to be packaged in a folded configuration before the deployment. It must be relatively small, lightweight, non-damaging to the inflated system, and be able to become stiff in a short time. One stiffening method is to use a flexible material inserted in the deployable system, which, upon a temperature curing, can become stiff and is capable to support the entire structure. There are two conditions during the space operations when the inflated volume could be damaged: during the transonic region of the launch phase and when the curing of the rigidizing element occurs. In both cases, an excess of pressure within the volume containing the rigid element could burst the walls of the low-pressure gas inflated portion of the system. This paper investigates those two conditions and indicates the vents, which will prevent those damaging overpressures. Vent openings at the non-inflated volumes have been calculated for the conditions existing during the launch. Those vents allow the initially folded volume to exhaust the trapped atmospheric gas at approximately the same rate as the ambient pressure drops. That will prevent pressure gradients across the container walls which otherwise could be as high as 14.7 psi. The other condition occurring during the curing of the stiffening element has been investigated. This has required the testing of the element to obtain the gas generation during the curing and the transformation from a pliable material to a rigid one. The tested material is a composite graphite/epoxy weave. The outgassing of the uncured sample at 121C was carried with the Cahn Microbalance and with other outgassing facilities including the micro-CVCM ASTM E-595 facility. The tests provided the mass of gas evolved during the test. That data, including the chemical nature of the evolved gas, provided the data for the calculation of the pressure produced within the volume. The evaluation of the areas of the vents that would prevent excessive pressures and provide a rapid release of the gas away from contamination sensitive surfaces has been carried out. The pressure decay with time has been indicated.

Scialdone, John J.↗

Future Opportunities for LWR Irradiations in US Test Reactors

After several years of relatively low activity in the field of Light Water Reactor (LWR) fuel development, the Department of Energy again began to engage in developing new fuel technologies and irradiation performance data prompted by the Fukushima Daichi nuclear accidents. New competencies for irradiation testing in material test reactors in the United States began to be developed at this time using the Advanced Test Reactor (ATR), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), and the Transient Reactor Test Facility (TREAT). Capsules for testing fuel and cladding materials in ATR and HFIR were deployed, a Pressurized Water Reactor (PWR) condition loop for testing fuel rods was established in ATR, cladding corrosion studies were performed using a water loop in MITR, and TREAT pulse testing capabilities were commissioned for fuel rods in water capsules. The more recent and unexpected closure of the Halden Boiling Water Reactor (HBWR) also prompted further investments in Loss of Coolant Accident (LOCA) testing capabilities at TREAT. New configurations of these test devices show further potential in enhanced steam condition control and other investigations are building toward a flowing water loop for testing transient to dryout conditions. The closure of HBWR also prompted a major project currently underway to construct additional water loops in ATR where a novel approach is being pursued to enable Boiling Water Reactor (BWR) conditions. A meaningful collaborative project was awarded to MITR which, amidst an unexpected major overhaul of the reactor, has expanded cladding corrosion test capabilities at MITR. New explorations have led to methods for unique experiments at HFIR including channel box irradiations. New device developments are also bridging toward future potential for instrumented capsule irradiation tests in ATR and HFIR. Finally, a new project referred to as the System Physics Advanced Reactor Critical facility (SPARC) is gaining traction towards a large zero-power reactor able to produce physics validation data for LWR fuel bundle designs with increased enrichment and enhanced absorbers for 24-month operation cycles. This paper provides a brief summary of the status of these irradiation testbed capabilities with an emphasis on current efforts toward future capabilities to obtain new data and maximize the performance potential of LWR fuel technologies.

Woolstenhulme, Nicolas [Idaho National Laboratory ↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Development of Test Protocols for International Space Station Particulate Filters

Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing can be applied to conducting acceptance testing and inventory testing for future manned exploration programs with air revitalization filtration needs, possibly even for in-situ filter element integrity testing for extensively long-duration missions. We plan to address the unique needs for test protocols for crewed spacecraft particulate filters by preparing the initial version of a standard, to be documented as a NASA Technical Memorandum (TM).

Filtration↗

A Composite Analysis of Snowfall Modes from Four Winter Seasons in Marquette, Michigan

Presented are four winter seasons of data from an enhanced precipitation instrument suite based at the National Weather Service (NWS) Office in Marquette (MQT), Michigan (250–500 cm of annual snow accumulation). In 2014 the site was augmented with a Micro Rain Radar (MRR) and a Precipitation Imaging Package (PIP). MRR observations are utilized to partition large-scale synoptically driven (deep)and surface-forced (shallow) snow events. Coincident PIP and NWS MQT meteorological surface observations illustrate different characteristics with respect to snow event category. Shallow snow events are often extremely shallow, with MRR-indicated precipitation heights of less than 1500 m above ground level. Large vertical reflectivity gradients indicate efficient particle growth, and increased boundary layer turbulence inferred from observations of spectral width implies increased aggregation in shallow snow events. Shallow snow events occur 2 times as often as deep events; however, both categories contribute approximately equally to estimated annual accumulation. PIP measurements reveal distinct regime-dependent snow microphysical differences, with shallow snow events having broader particle size distributions and comparatively fewer small particles and deep snow events having narrower particle size distributions and comparatively more small particles. In addition, coincident surface meteorological measurements indicate that most shallow snow events are associated with surface winds originating from the northwest (over Lake Superior), cold temperatures, and relatively high surface pressures, which are characteristics that are consistent with cold-air outbreaks. Deep snow events have meteorologically distinct conditions that are accordant with midlatitude cyclones and frontal structures, with mostly southwest surface winds, warmer temperatures approaching freezing, and lower surface pressures.

Claire Pettersen↗

EUSO-SPB2 Fluorescence Telescope trigger test within the EUSO@TurLab Project

The second generation Extreme Universe Space Observatory on a Super-Pressure Balloon (EUSO-SPB2) mission is on track to be approved by NASA for a long duration flight (up to 100 days) in 2023 from Wanaka, New Zealand. EUSO-SPB2 will monitor the night atmosphere of the Southern hemisphere from 33 km altitude to detect Ultra-High Energy Cosmic Rays (UHECRs) and search for astrophysical and cosmogenic neutrinos. EUSO-SPB2 features two telescopes, a Cherenkov (CT) and a Fluorescence (FT) Telescope. The hardware implementation and performance of the FT trigger logic were tested at the TurLab facility, hosted at the University of Turin. In conclusion, the tests proved the correct hardware implementation of the trigger logic and its ability to detect μs timescale transient signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon kinetics in a natural indoor radon chamber

An unusual 180 m 3 storage room in the basement of a two-story laboratory building is unventilated, and separated from occupiable rooms by double steel doors. The space completely borders on soil through the concrete floor and two of its concrete walls. The room also contains a separate inner chamber with 1 m thick concrete walls designed to damp vibrations in the room above it. The space boasts a relatively high radon level, 1083 Bq m –3 , which varies with local outdoor environmental conditions. Measurements were made of radon concentrations at various locations and heights within the facility. More than a year of continuous radon concentration data corresponding to a single location are also available, along with measurements of indoor and outdoor pressure, temperature, and humidity. Data were also collected with as many as five fans placed in different locations and cycled on for variable time periods. First order linear kinetic models were created to explain the observed approaches to steady state due to changing conditions and wash-out resulting from intentional ventilation. Results demonstrate a good fit between changes in the radon concentration level and the developed compartmental models. Furthermore, no significant differences were observed between radon concentration at different locations or heights in the chamber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron density measurement using a partially covered hairpin resonator in an inductively coupled plasma

Hairpin probes are used to determine electron densities via measuring the shift of the resonant frequency of the probe structure when immersed in a plasma. This manuscript presents new developments in hairpin probe hardware and theory that have enabled measurements in a high electron density plasma, up to approximately 10 12 cm -3 , corresponding to a plasma frequency of about 9 GHz. Hardware developments include the use of both quarter-wavelength and three-quarter-wavelength partially covered hairpin probes in a transmission mode together with an easily reproducible implementation of the associated microwave electronics using commercial off-the-shelf components. The three-quarter-wavelength structure is operated at its second harmonic with the purpose of measuring higher electron densities. New theory developments for interpreting the probe measurements include the use of a transmission line model to find an accurate relationship between the resonant frequency of the probe and the electron density, including effects of partially covering the probes with epoxy. Measurements are taken in an inductively coupled plasma sustained in argon at pressures below 50 mTorr. Results are compared with Langmuir probe and interferometry measurements.

47 OTHER INSTRUMENTATION↗

Development and Testing of a Friction-Based Post-Installable Fiber-Optic Monitoring System for Subsea Applications

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system capable of measuring pressure, strain, and temperature that can be deployed on existing subsea structures. A summary is provided of the design concept, prototype development, prototype performance testing, and subsequent design refinements of the device. The results of laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are also included. Limitations of the initial concept were identified during testing and future design improvements were proposed and later implemented. These new features enhance the coupling of the sensor device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on flowlines, risers, and other subsea structures. The work described in this paper investigates the design and test of a friction-based coupling device (herein referred to as a friction clamp) which is suitable for pipelines and structures that are suspended in the water column as well as for those that are resting on the seabed. The monitoring elements consist of fiberoptic sensors that are bonded to a stainless steel clamshell assembly with a high-friction surface coating. The friction clamp incorporates a single hinge design to facilitate installation of the clamp and dual rows of opposing fasteners to distribute the clamping force along the structure. The friction clamp can be modified to be installed by commercial divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance technologies that will benefit the environment, the public, and commercial industries.

Bentley, Nicole L.↗