Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heart Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

The Improvement Cycle: Analyzing Our Experience

NASA's Software Engineering Laboratory (SEL), one of the earliest pioneers in the areas of software process improvement and measurement, has had a significant impact on the software business at NASA Goddard. At the heart of the SEL's improvement program is a belief that software products can be improved by optimizing the software engineering process used to develop them and a long-term improvement strategy that facilitates small incremental improvements that accumulate into significant gains. As a result of its efforts, the SEL has incrementally reduced development costs by 60%, decreased error rates by 85%, and reduced cycle time by 25%. In this paper, we analyze the SEL's experiences on three major improvement initiatives to better understand the cyclic nature of the improvement process and to understand why some improvements take much longer than others.

Pajerski, Rose↗

TU-G-BRD-05: Results From Multi-Institutional Measurements with An Anthropomorphic Spine Phantom

Purpose: To analyze the results from an anthropomorphic spine phantom used for credentialing institutions for National Cancer Institute (NCI) sponsored clinical trial. Methods: An anthropomorphic phantom that contains left and right lungs, a heart, an esophagus, spinal cord, bony material and a PTV was sent to institutions wishing to be credentialed for NCI trials. The PTV holds 4 TLD and radiochromic film in the axial and sagittal planes. The heart holds one TLD. Institutions created IMRT plans to cover ≥90% of the PTV with 6 Gy and limit the cord dose to <0.35cc receiving 3.75 Gy and <1.2cc receiving 2.63 Gy. They were instructed to treat the phantom as they would a patient, including making plan specific IMRT/SBRT QA measurements before treatment. The TLD results in the PTV were required to be within ±7% of the plan dose. A gamma calculation was performed using the film results and the submitted DICOM plan. ≥85% of the analyzed region was required to pass a 5%/3 mm criteria. Results: 176 institutions irradiated the spine phantom for a total of 255 results. The pass rate was 73% (187 irradiations) overall. 44 irradiations failed only the gamma criteria, 2 failed only the dose criteria and 22 failed both. The most used planning systems were Eclipse (116) and Pinnacle (52) and they had pass rates of 76% and 71%, respectively. The AAA algorithm had a pass rate of 77% while superposition type algorithms had a 71% pass rate. The average TLD measurement to institution calculation ratio was 0.99 (0.04 std dev.). The average percent pixels passing the gamma criteria for films was 89% (12% std dev.) Conclusion: Results show that this phantom is an important part of credentialing and that we have room for improvement in IMRT/SBRT spine treatments. This work was supported by PHS CA180803 and CA037422 awarded by NCI, DHHS.

60 APPLIED LIFE SCIENCES↗

Dimethadione embryotoxicity in the rat is neither correlated with maternal systemic drug concentrations nor embryonic tissue levels

Pregnant rats treated with dimethadione (DMO), the N-demethylated metabolite of the anticonvulsant trimethadione, produce offspring having a 74% incidence of congenital heart defects (CHD); however, the incidence of CHD has high inter-litter variability (40–100%) that presents a challenge when studying the initiating events prior to the presentation of an abnormal phenotype. We hypothesized that the variability in CHD incidence was the result of differences in maternal systemic concentrations or embryonic tissue concentrations of DMO. To test this hypothesis, dams were administered 300 mg/kg DMO every 12 h from the evening of gestational day (GD) 8 until the morning of GD 11 (six total doses). Maternal serum levels of DMO were assessed on GD 11, 12, 13, 14, 15, 18 and 21. Embryonic tissue concentrations of DMO were assessed on GD 11, 12, 13 and 14. In a separate cohort of GD 12 embryos, DMO concentrations and parameters of growth and development were assessed to determine if tissue levels of DMO were correlated with these endpoints. Embryos were exposed directly to different concentrations of DMO with whole embryo culture (WEC) and their growth and development assessed. Key findings were that neither maternal systemic concentrations nor tissue concentrations of DMO identified embryos that were sensitive or resistant to DMO in vivo. Direct exposure of embryos to DMO via WEC also failed to show correlations between embryonic concentrations of DMO with developmental outcomes in vitro. We conclude that neither maternal serum nor embryonic tissue concentrations of DMO predict embryonic outcome. - Highlights: • Dimethadione (DMO) induces septation defects (VSD) in rat offspring. • Despite high rate of VSD defects inter-litter variability is 40–100%. • Maternal and embryonic concentrations of DMO were assessed. • Neither serum nor tissue levels of DMO were correlated with embryotoxicity.

60 APPLIED LIFE SCIENCES↗

EXPANDED SEARCH FOR z {approx} 10 GALAXIES FROM HUDF09, ERS, AND CANDELS DATA: EVIDENCE FOR ACCELERATED EVOLUTION AT z > 8?

We search for z {approx} 10 galaxies over {approx}160 arcmin{sup 2} of Wide-Field Camera 3 (WFC3)/IR data in the Chandra Deep Field South, using the public HUDF09, Early Release Science, and CANDELS surveys, that reach to 5{sigma} depths ranging from 26.9 to 29.4 in H{sub 160} AB mag. z {approx}> 9.5 galaxy candidates are identified via J{sub 125} - H{sub 160} > 1.2 colors and non-detections in any band blueward of J{sub 125}. Spitzer Infrared Array Camera (IRAC) photometry is key for separating the genuine high-z candidates from intermediate-redshift (z {approx} 2-4) galaxies with evolved or heavily dust obscured stellar populations. After removing 16 sources of intermediate brightness (H{sub 160} {approx} 24-26 mag) with strong IRAC detections, we only find one plausible z {approx} 10 galaxy candidate in the whole data set, previously reported in Bouwens et al.. The newer data cover a 3 Multiplication-Sign larger area and provide much stronger constraints on the evolution of the UV luminosity function (LF). If the evolution of the z {approx} 4-8 LFs is extrapolated to z {approx} 10, six z {approx} 10 galaxies are expected in our data. The detection of only one source suggests that the UV LF evolves at an accelerated rate before z {approx} 8. The luminosity density is found to increase by more than an order of magnitude in only 170 Myr from z {approx} 10 to z {approx} 8. This increase is {>=}4 Multiplication-Sign larger than expected from the lower redshift extrapolation of the UV LF. We are thus likely witnessing the first rapid buildup of galaxies in the heart of cosmic reionization. Future deep Hubble Space Telescope WFC3/IR data, reaching to well beyond 29 mag, can enable a more robust quantification of the accelerated evolution around z {approx} 10.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of an Image-Derived Input Function for Kinetic Modeling of Nicotinic Acetylcholine Receptor-Binding PET Ligands in Mice

Positron emission tomography (PET) radioligands that bind with high-affinity to α4β2-type nicotinic receptors (α4β2Rs) allow for in vivo investigations of the mechanisms underlying nicotine addiction and smoking cessation. Here, we investigate the use of an image-derived arterial input function and the cerebellum for kinetic analysis of radioligand binding in mice. Two radioligands were explored: 2-[ 18 F]FA85380 (2-FA), displaying similar pKa and binding affinity to the smoking cessation drug varenicline (Chantix), and [ 18 F]Nifene, displaying similar pKa and binding affinity to nicotine. Time–activity curves of the left ventricle of the heart displayed similar distribution across wild type mice, mice lacking the β2-subunit for ligand binding, and acute nicotine-treated mice, whereas reference tissue binding displayed high variation between groups. Binding potential estimated from a two-tissue compartment model fit of the data with the image-derived input function were higher than estimates from reference tissue-based estimations. Rate constants of radioligand dissociation were very slow for 2-FA and very fast for Nifene. We conclude that using an image-derived input function for kinetic modeling of nicotinic PET ligands provides suitable results compared to reference tissue-based methods and that the chemical properties of 2-FA and Nifene are suitable to study receptor response to nicotine addiction and smoking cessation therapies.

2-FA85380↗

Cardiolipin modulates allosterically peroxynitrite detoxification by horse heart cytochrome c

Research highlights: {yields} Cardiolipin binding to cytochrome c. {yields} Cardiolipin-dependent peroxynitrite isomerization by cytochrome c. {yields} Cardiolipin-cytochrome c complex plays pro-apoptotic effects. {yields} Cardiolipin-cytochrome c complex plays anti-apoptotic effects. -- Abstract: Upon interaction with bovine heart cardiolipin (CL), horse heart cytochrome c (cytc) changes its tertiary structure disrupting the heme-Fe-Met80 distal bond, reduces drastically the midpoint potential out of the range required for its physiological role, binds CO and NO with high affinity, and displays peroxidase activity. Here, the effect of CL on peroxynitrite isomerization by ferric cytc (cytc-Fe(III)) is reported. In the absence of CL, hexa-coordinated cytc does not catalyze peroxynitrite isomerization. In contrast, CL facilitates cytc-Fe(III)-mediated isomerization of peroxynitrite in a dose-dependent fashion inducing the penta-coordination of the heme-Fe(III)-atom. The value of the second order rate constant for CL-cytc-Fe(III)-mediated isomerization of peroxynitrite (k{sub on}) is (3.2 {+-} 0.4) x 10{sup 5} M{sup -1} s{sup -1}. The apparent dissociation equilibrium constant for CL binding to cytc-Fe(III) is (5.1 {+-} 0.8) x 10{sup -5} M. These results suggest that CL-cytc could play either pro-apoptotic or anti-apoptotic effects facilitating lipid peroxidation and scavenging of reactive nitrogen species, such as peroxynitrite, respectively.

60 APPLIED LIFE SCIENCES↗

Nonlinear transmission of an intense terahertz field through monolayer graphene

We report nonlinear terahertz (THz) effects in monolayer graphene, giving rise to transmission enhancement of a single-cycle THz pulse when the incident THz peak electric field is increased. This transmission enhancement is attributed to reduced photoconductivity, due to saturation effects in the field-induced current and increased intraband scattering rates arising from transient heating of electrons. We have developed a tight-binding model of the response using the length gauge interaction Hamiltonian that provides good qualitative agreement. The model fully accounts for the nonlinear response arising from the linear dispersion energy spectrum in graphene. The results reveal a strong dependence of the scattering time on the THz field, which is at the heart of the observed nonlinear response.

36 MATERIALS SCIENCE↗

Locoregional Treatment for Breast Carcinoma After Hodgkin's Lymphoma: The Breast Conservation Option

Purpose: To report clinical and pathologic characteristics and outcome of breast cancer (BC) after irradiation for Hodgkin's lymphoma (HL) in women treated at the Institut Curie, with a special focus on the breast-conserving option. Methods and Materials: Medical records of 72 women who developed either ductal carcinoma in situ or Stage I-III invasive carcinoma of the breast after HL between 1978 and 2009 were retrospectively reviewed. Results: Median age at HL diagnosis was 23 years (range, 14-53 years). Median total dose received by the mediastinum was 40 Gy, mostly by a mantle-field technique. Breast cancers occurred after a median interval of 21 years (range, 5-40 years). Ductal invasive carcinoma and ductal carcinoma in situ represented, respectively, 51 cases (71%) and 14 cases (19%). Invasive BCs consisted of 47 cT0-2 tumors (82%), 5 cN1-3 tumors (9%), and 20 Grade 3 tumors (35%). Locoregional treatment for BCs consisted of mastectomy with (3) or without (36) radiotherapy in 39 patients and lumpectomy with (30) or without (2) adjuvant radiotherapy in 32 patients. The isocentric lateral decubitus radiation technique was used in 17 patients after breast-conserving surgery (57%). With a median follow-up of 7 years, 5-year overall survival rate and locoregional control rate were, respectively, 74.5% (95% confidence interval [CI], 64-88%) and 82% (95% CI, 72-93%) for invasive carcinoma and 100% (95% CI, 100 -100%) and 92% (95% CI, 79-100%) for in situ carcinoma. In patients with invasive tumors, the 5-year distant disease-free survival rate was 79% (95% CI, 69-91%), and 13 patients died of progressive BC. Contralateral BC was diagnosed in 10 patients (14%). Conclusions: Breast-conserving treatment can be an option for BCs that occur after HL, despite prior thoracic irradiation. It should consist of lumpectomy and adjuvant breast radiotherapy with use of adequate techniques, such as the lateral decubitus isocentric position, to protect the underlying heart and lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Arterial Embolization and Chemoembolization in the Management of Patients with Large-Volume Liver Metastases

The purpose of this study was to assess the role of hepatic arterial embolization (HAE) and chemoembolization (HACE) in patients with large-volume liver metastases. Patients with metastatic neuroendocrine tumors, melanomas, or gastrointestinal stromal tumors (GISTs) with >75% liver involvement who underwent HAE or HACE were included in the study. Radiologic response, progression-free survival (PFS), overall survival (OS), and postprocedure complications were assessed. Sixty patients underwent 123 treatment sessions. Of the 48 patients for whom follow-up imaging was available, partial response was seen in 12 (25%) patients, minimal response in 6 (12%), stable disease in 22 (46%), and progressive disease in 8 (17%). Median OS and PFS were 9.3 and 4.9 months, respectively. Treatment resulted in radiologic response or disease stabilization in 82% and symptomatic response in 65% of patients with neuroendocrine tumors. Patients with neuroendocrine tumors had higher response rates (44% vs. 27% and 0%; p = 0.31) and longer PFS (9.2 vs. 2.0 and 2.3 months; p < 0.0001) and OS (17.9 vs. 2.4 and 2.3 months; p < 0.0001) compared to patients with melanomas and GISTs. Major complications occurred in 21 patients after 23 (19%) of the 123 sessions. Nine of the 12 patients who developed major complications resulting in death had additional risk factors-carcinoid heart disease, sepsis, rapidly worsening performance status, or anasarca. In conclusion, in patients with neuroendocrine tumors with >75% liver involvement, HAE/HACE resulted in symptom palliation and radiologic response or disease stabilization in the majority of patients. Patients with hepatic metastases from melanomas and GISTs, however, did not show any appreciable benefit from this procedure. Patients with massive liver tumor burden, who have additional risk factors, should not be subjected to HAE/HACE because of the high risk of procedure-related mortality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Vector Electric Field Investigation on the C/NOFS Satellite

We provide an overview of the Vector Electric Field Investigation (VEFI) on the Air Force Communication/Navigation Outage Forecasting System (C/NOFS) satellite, a mission designed to understand, model, and forecast the presence of equatorial ionospheric irregularities. VEFI is a NASA/GSFC instrument funded by the Air Force Research Laboratory whose main objectives are to: 1) investigate the role of the ambient electric fields in initiating nighttime ionospheric density depletions and turbulence; 2) determine the quasi-DC electric fields associated with abrupt, large amplitude, density depletions, and 3) quantify the spectrum of the wave electric fields and plasma densities (irregularities) associated with density depletions typically referred to as equatorial spread-F. The VEFI instrument includes a vector electric field double probe detector, a fixed-bias Langmuir probe operating in the ion saturation regime, a flux-gate magnetometer, an optical lightning detector, and associated electronics. The heart of the instrument is the set of detectors designed to measure DC and AC electric fields using 6 identical booms that provide 3 axis, 20-m tip-to-tip orthogonal double probes. Each probe extends a 10 cm diameter sphere containing an embedded preamplifier. VEFI also includes a burst memory that enables snapshots of data from 1-8 channels of selected instruments to be sampled at rates of up to 32 kHz each. The bursts may be triggered by the detection of density depletions, intense electric field wave activity in a given band, lightning detector pulses, or an event at a pre-determined time or location. All VEFI instrument components are working exceptionally well. A description of the instrument, its sensors, and their sampling frequencies and sensitivities will be presented. Representative measurements will be shown.

Pfaff, R.↗

Temperature equilibration rate with Fermi-Dirac statistics

We calculate analytically the electron-ion temperature equilibration rate in a fully ionized, weakly to moderately coupled plasma, using an exact treatment of the Fermi-Dirac electrons. The temperature is sufficiently high so that the quantum-mechanical Born approximation to the scattering is valid. It should be emphasized that we do not build a model of the energy exchange mechanism, but rather, we perform a systematic first principles calculation of the energy exchange. At the heart of this calculation lies the method of dimensional continuation, a technique that we borrow from quantum field theory and use in a different fashion to regulate the kinetic equations in a consistent manner. We can then perform a systematic perturbation expansion and thereby obtain a finite first-principles result to leading and next-to-leading order. Unlike model building, this systematic calculation yields an estimate of its own error and thus prescribes its domain of applicability. The calculational error is small for a weakly to moderately coupled plasma, for which our result is nearly exact. It should also be emphasized that our calculation becomes unreliable for a strongly coupled plasma, where the perturbative expansion that we employ breaks down, and one must then utilize model building and computer simulations. Besides providing different and potentially useful results, we use this calculation as an opportunity to explain the method of dimensional continuation in a pedagogical fashion. Interestingly, in the regime of relevance for many inertial confinement fusion experiments, the degeneracy corrections are comparable in size to the subleading quantum correction below the Born approximation. For consistency, we therefore present this subleading quantum-to-classical transition correction in addition to the degeneracy correction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mathematical modelling of flow distribution in the human cardiovascular system

The paper presents a detailed model of the entire human cardiovascular system which aims to study the changes in flow distribution caused by external stimuli, changes in internal parameters, or other factors. The arterial-venous network is represented by 325 interconnected elastic segments. The mathematical description of each segment is based on equations of hydrodynamics and those of stress/strain relationships in elastic materials. Appropriate input functions provide for the pumping of blood by the heart through the system. The analysis employs the finite-element technique which can accommodate any prescribed boundary conditions. Values of model parameters are from available data on physical and rheological properties of blood and blood vessels. As a representative example, simulation results on changes in flow distribution with changes in the elastic properties of blood vessels are discussed. They indicate that the errors in the calculated overall flow rates are not significant even in the extreme case of arteries and veins behaving as rigid tubes.

NASA Center JSC↗

Science Goals in Radiation Protection for Exploration

Space radiation presents major challenges to future missions to the Earth s moon or Mars. Health risks of concern include cancer, degenerative and performance risks to the central nervous system, heart and lens, and the acute radiation syndromes. The galactic cosmic rays (GCR) contain high energy and charge (HZE) nuclei, which have been shown to cause qualitatively distinct biological damage compared to terresterial radiation, such as X-rays or gamma-rays, causing risk estimates to be highly uncertain. The biological effects of solar particle events (SPE) are similar to terresterial radiation except for their biological dose-rate modifiers; however the onset and size of SPEs are difficult to predict. The high energies of GCR reduce the effectiveness of shielding, while SPE s can be shielded however the current gap in radiobiological knowledge hinders optimization. Methods used to project risks on Earth must be modified because of the large uncertainties in projecting health risks from space radiation, and thus impact mission requirements and costs. We describe NASA s unique approach to radiation safety that applies probabilistic risk assessments and uncertainty based criteria within the occupational health program for astronauts and to mission design. The two terrestrial criteria of a point estimate of maximum acceptable level of risk and application of the principle of As Low As Reasonably Achievable (ALARA) are supplemented by a third requirement that protects against risk projection uncertainties using the upper 95% confidence level (CL) in radiation risk projection models. Exploration science goals in radiation protection are centered on ground-based research to achieve the necessary biological knowledge, and in the development of new technologies to improve SPE monitoring and optimize shielding. Radiobiology research is centered on a ground based program investigating the radiobiology of high-energy protons and HZE nuclei at the NASA Space Radiation Laboratory (NSRL) located at DoE s Brookhaven National Laboratory in Upton, NY. We describe recent NSRL results that are closing the knowledge gap in HZE radiobiology and improving exploration risk estimates. Linking probabilistic risk assessment to research goals makes it possible to express risk management objectives in terms of quantitative metrics, which include the number of days in space without exceeding a given risk level within well defined confidence limits, and probabilistic assessments of the effectiveness of design trade spaces such as material type, mass, solar cycle, crew selection criteria, and biological countermeasures. New research in SPE alert and risk assessment, individual radiation sensitivity, and biological countermeasure development are described.

Cucinotta, Francs A.↗

Disruption of Z-Disc Function Promotes Mechanical Dysfunction in Human Myocardium: Evidence for a Dual Myofilament Modulatory Role by Alpha-Actinin 2

The ACTN2 gene encodes α-actinin 2, located in the Z-disc of the sarcomeres in striated muscle. In this study, we sought to investigate the effects of an ACTN2 missense variant of unknown significance (p.A868T) on cardiac muscle structure and function. Left ventricular free wall samples were obtained at the time of cardiac transplantation from a heart failure patient with the ACTN2 A868T heterozygous variant. This variant is in the EF 3–4 domain known to interact with titin and α-actinin. At the ultrastructural level, ACTN2 A868T cardiac samples presented small structural changes in cardiomyocytes when compared to healthy donor samples. However, contractile mechanics of permeabilized ACTN2 A868T variant cardiac tissue displayed higher myofilament Ca 2+ sensitivity of isometric force, reduced sinusoidal stiffness, and faster rates of tension redevelopment at all Ca 2+ levels. Small-angle X-ray diffraction indicated increased separation between thick and thin filaments, possibly contributing to changes in muscle kinetics. Molecular dynamics simulations indicated that while the mutation does not significantly impact the structure of α-actinin on its own, it likely alters the conformation associated with titin binding. Our results can be explained by two Z-disc mediated communication pathways: one pathway that involves α-actinin’s interaction with actin, affecting thin filament regulation, and the other pathway that involves α-actinin’s interaction with titin, affecting thick filament activation. This work establishes the role of α-actinin 2 in modulating cross-bridge kinetics and force development in the human myocardium as well as how it can be involved in the development of cardiac disease.

59 BASIC BIOLOGICAL SCIENCES↗

SU-F-T-632: On the Use of Intensity Modulated Arc Therapy for Thoracic Vertebral Metastases SBRT Treatment

Purpose: To retrospectively evaluate quality, efficiency and delivery accuracy of intensity modulated arc therapy (IMAT) plans for thoracic-vertebral metastases using stereotactic body radiotherapy (SBRT). Methods: After obtaining approval of RPC-benchmark plan, seven previously treated thoracic-vertebral metastases patients with non-coplanar hybrid arcs(NC-HA)using 1–2 3D-dynamic conformal partial-arcs plus 7–9 IMRT-beams were re-optimized with IMAT using 3 full co-planar arcs. Tumors were located between T2–T7. T1/T2-weighted MRI images were co-registered with planning-CT. PTVs were between 24.3–240.1cc(median=48.1cc). Prescription was 30Gy in 5 fractions with 6-MV beams at Novalis-TX consisting of HD-MLC.Plans were compared for target coverage:conformality index(CI),homogeneity index(HI),PTVD90. Organs-at-risks(OARs)was evaluated for spinal cord(Dmax, D0.35cc, and D1.2cc), esophagus(Dmax and D5cc),heart(Dmax, D15cc)and lung(V5 and V10). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance(QA) plan. Beam-on time was recorded and a gamma index was used to compare agreement between planned and measured doses. Results: SBRT IMAT plans resulted in superior CI(1.02 vs. 1.36, p=0.05) and HI (0.14 vs. 0.27, p=0.01). PTVD90 was improved but statistically insignificant (31.0 vs. 30.4Gy, p=0.38). IMAT resulted in statistically significant improvements in OARs sparing: esophagus max(22.5 vs. 27.0Gy, p=0.03), esophagus 5cc (17.6 vs. 21.5Gy, p=0.02) and heart max(13.1 vs. 15.8Gy, p=0.03). Spinal cord,lung V5 and V10 were lower but statistically insignificant. Average total MU and beam-on time were 2598±354 vs. 3542±495 and 4.7±0.6 min vs. 7.1±1.0min for IMAT vs. NC-HA (without accounting for couch kicks time for NC-HA). IMAT plans demonstrated an accurate dose delivery of 95.5±1.0% for clinical gamma passing-rate of 2%/2mm criteria on MapCHECK, that was comparable to NC-HA plans. Conclusion: IMAT plans provided highly conformal and homogeneous dose distributions to target and reduced OARs doses compared to NC-HA. Total MU was reduced by a factor of 1.4 and subsequently decreased treatment times significantly - potentially minimizing intra-fraction motion error and owing to patient comfort. SBRT using IMAT planning for single fraction thoracic-vertebrae metastases will be investigated.

60 APPLIED LIFE SCIENCES↗

The Application of a Massively Parallel Computer to the Simulation of Electrical Wave Propagation Phenomena in the Heart Muscle Using Simplified Models

The simulation of heart arrhythmia and fibrillation are very important and challenging tasks. The solution of these problems using sophisticated mathematical models is beyond the capabilities of modern super computers. To overcome these difficulties it is proposed to break the whole simulation problem into two tightly coupled stages: generation of the action potential using sophisticated models. and propagation of the action potential using simplified models. The well known simplified models are compared and modified to bring the rate of depolarization and action potential duration restitution closer to reality. The modified method of lines is used to parallelize the computational process. The conditions for the appearance of 2D spiral waves after the application of a premature beat and the subsequent traveling of the spiral wave inside the simulated tissue are studied.

Karpoukhin, Mikhii G.↗

French Innovative Thermal Treatment Processes for The Management Radioactive Organic Liquid Waste - 19017

The nuclear industry as well as hospitals or some research laboratories produce Radioactive Organic Liquid Waste (ROLW) such as scintillation cocktails for medical imaging, labeled molecules for medical research or liquids from former activities. In order to be compatible with disposal facilities requirements, this waste must be inerted and stabilized in solid matrix. The route generally used is incineration in the Centraco facilities at the Marcoule site (Gard, France), ashes produced being cemented downstream. However, liquids whose chemical or radiological characteristics are not compatible with the incinerator operating rules (high level of {sup 14}C or halogen content, corrosive gas production etc.) cannot follow this path. The purpose of the MILOR project is then to propose alternative paths to treat all kinds of ROLW. Initiated in September 2017, this project has the technical objective of developing, over a four-year period, two pilot-scale mineralization processes. Two variants of complementary plasma technologies are evaluated: aerial plasma with the 'IDOHL' process and submerged plasma with the 'ELIPSE' process. Compared with other methods, thermal plasmas have unique characteristics such as rapid decomposition with high throughput, fast startup and shutdown, and high-energy delivery. The process called IDOHL consists of a process involving an induction plasma in which the liquids are directly introduced. It has been designed for organic liquids without mineral load and for treatment rates less than 0.5 l/h. This type of plasma allows the destruction of liquid organohalogens without any prior evaporation or treatment. Specific gas treatment systems have been developed to direct the gas produced to a dry or wet gas treatment system. One aim of the project is to subsequently install the process in a radioactive zone at Saclay DRF. The second called ELIPSE consists of a breakthrough process involving a submerged plasma at the heart of which organic liquids are also introduced. Current research has demonstrated that such a technique may enable the instantaneous and complete destruction of liquids with a wide variety of constituents, such as chlorine, fluorine, or phosphorus. The submersion solution offers many advantages: quenching and cleaning of combustion gases; filtering of the particles they contain; and cooling maintained for the entire process, which guarantees excellent corrosion control. An advantage of this type of design is that the gas treatment system can be reduced to a demister-condenser followed by a simple safety filter, thereby offering the additional advantage of an extremely compact treatment system. This design also allows the ELIPSE process to become by this way an embeddable process if required. The MILOR project, financed by the French State through investment program is a tripartite project bringing together Andra, in charge of radioactive waste management, the CEA in charge of leading scientific and technological researches to propose effective ways of treatment and the company A3i whose role is to ensure the subsequent industrial development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-J-113: Multi-Atlas Based Automatic Organ Segmentation for Lung Radiotherapy Planning

Purpose: Normal organ segmentation is one time-consuming and labor-intensive step for lung radiotherapy treatment planning. The aim of this study is to evaluate the performance of a multi-atlas based segmentation approach for automatic organs at risk (OAR) delineation. Methods: Fifteen Lung stereotactic body radiation therapy patients were randomly selected. Planning CT images and OAR contours of the heart - HT, aorta - AO, vena cava - VC, pulmonary trunk - PT, and esophagus – ES were exported and used as reference and atlas sets. For automatic organ delineation for a given target CT, 1) all atlas sets were deformably warped to the target CT, 2) the deformed sets were accumulated and normalized to produce organ probability density (OPD) maps, and 3) the OPD maps were converted to contours via image thresholding. Optimal threshold for each organ was empirically determined by comparing the auto-segmented contours against their respective reference contours. The delineated results were evaluated by measuring contour similarity metrics: DICE, mean distance (MD), and true detection rate (TD), where DICE=(intersection volume/sum of two volumes) and TD = {1.0 - (false positive + false negative)/2.0}. Diffeomorphic Demons algorithm was employed for CT-CT deformable image registrations. Results: Optimal thresholds were determined to be 0.53 for HT, 0.38 for AO, 0.28 for PT, 0.43 for VC, and 0.31 for ES. The mean similarity metrics (DICE[%], MD[mm], TD[%]) were (88, 3.2, 89) for HT, (79, 3.2, 82) for AO, (75, 2.7, 77) for PT, (68, 3.4, 73) for VC, and (51,2.7, 60) for ES. Conclusion: The investigated multi-atlas based approach produced reliable segmentations for the organs with large and relatively clear boundaries (HT and AO). However, the detection of small and narrow organs with diffused boundaries (ES) were challenging. Sophisticated atlas selection and multi-atlas fusion algorithms may further improve the quality of segmentations.

60 APPLIED LIFE SCIENCES↗