Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Conceptual Design for SuperCDMS SNOLAB

Beyond the present dark matter direct detection experiment at the Soudan underground laboratory, the SuperCDMS Collaboration is engaged in R and D activities for a 100-kg scale germanium dark matter experiment nominally sited at SNOLAB (2070 m overburden of rock). The expected sensitivity after 3 years of running is 3 x 10{sup -46} cm{sup 2} for the spin-independent cross section, an order of magnitude improvement over present exclusion limits for WIMP masses {approx}80 GeV/c{sup 2}. At this depth, and appropriate design of shielding and cryostat, neutron backgrounds will be negligible. The baseline design is an expanded version of CDMS II with Ge substrates (100 x 33 mm discs) instrumented with the iZIP phonon sensor layout to achieve the electron surface-event rejection power required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of Phonon Physics in the CDMS Detector Monte Carlo

The SuperCDMS collaboration is a dark matter search effort aimed at detecting the scattering of WIMP dark matter from nuclei in cryogenic germanium targets. The CDMS Detector Monte Carlo (CDMS-DMC) is a simulation tool aimed at achieving a deeper understanding of the performance of the SuperCDMS detectors and aiding the dark matter search analysis. We present results from validation of the phonon physics described in the CDMS-DMC and outline work towards utilizing it in future WIMP search analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo Simulation of Massive Absorbers for Cryogenic Calorimeters

There is a growing interest in cryogenic calorimeters with macroscopic absorbers for applications such as dark matter direct detection and rare event search experiments. The physics of energy transport in calorimeters with absorber masses exceeding several grams is made complex by the anisotropic nature of the absorber crystals as well as the changing mean free paths as phonons decay to progressively lower energies. We present a Monte Carlo model capable of simulating anisotropic phonon transport in cryogenic crystals. We have initiated the validation process and discuss the level of agreement between our simulation and experimental results reported in the literature, focusing on heat pulse propagation in germanium. The simulation framework is implemented using Geant4, a toolkit originally developed for high-energy physics Monte Carlo simulations. Geant4 has also been used for nuclear and accelerator physics, and applications in medical and space sciences. We believe that our current work may open up new avenues for applications in material science and condensed matter physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SuperCDMS Cold Hardware Design

We discuss the current design of the cold hardware and cold electronics to be used in the upcoming SuperCDMS Soudan deployment. Engineering challenges associated with such concerns as thermal isolation, microphonics, radiopurity, and power dissipation are discussed, along with identifying the design changes necessary for SuperCDMS SNOLAB. The Cryogenic Dark Matter Search (CDMS) employs ultrapure 1-inch thick, 3-inch diameter germanium crystals operating below 50 mK in a dilution cryostat. These detectors give an ionization and phonon signal, which gives us rejection capabilities regarding background events versus dark matter signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Characterization of Space Charge in IZIP Detectors

Interleaved ionization electrode geometries offer the possibility of efficient rejection of near-surface events. The CDMS collaboration has recently implemented this interleaved approach for the charge and phonon readout for our germanium detectors. During a recent engineering run, the detectors were found to lose ionization stability quickly. This paper summarizes studies done in order to determine the underlying cause of the instability, as well as possible running modes that maintain stability without unacceptable loss of livetime. Additionally, results are shown for the new version IZIP mask which attempts to improve the overall stability of the detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NTD-Ge Production in the LUMINEU Experiment Using Cryogenic Detectors for Rare Event Searches and Other Applications

To cope with the future large demand on neutron-transmutation-doped germanium of (NTD) sensors, our groups in LUMINEU started a new production line for NTD-Ge. This paper contains details on the NTD-Ge production, resistance measurement and a comparison of the performance in terms of noise and signal-to-noise ratio with an existing sensor contacts. This demonstrates our ability to produce NTD sensors for the desired range of working temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Second Harmonics of Localized Shear Waves in an Anisotropic Layer Between Anisotropic Half Spaces Under the Conditions of Imperfect Contact

We construct a numerical-analytic solution of the problem of generation of the nonlinear second harmonics in the course of propagation of elastic symmetric localized shear waves in the crystalline layer of cubic system of the m3m class located between the crystalline half spaces of the same type and the same class of anisotropy under the conditions of imperfect sliding contact of components of the waveguide. We determine the analytic form of the functions of wave motions for nonlinear anharmonic perturbations in the form of longitudinal-shear-type waves. We also perform the numerical investigations of the amplitude-frequency characteristics of the second harmonics for monochromatic localized waves in a layer of a single crystal of germanium between the half spaces from the single crystal of silicon.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Measurements of Short-Lived Fission Products from Uranium, Neptunium, Plutonium and Americium

Fission yields are especially well characterized for long-lived fission products. Modeling techniques incorporate numerous assumptions and can be used to deduce information about the distribution of short-lived fission products. This work is an attempt to gather experimental (model-independent) data on the short-lived fission products. Fissile isotopes of uranium, neptunium, plutonium and americium were irradiated under pulse conditions at the Washington State University 1 MW TRIGA reactor to achieve ~108 fissions. The samples were placed on a HPGe (high purity germanium) detector to begin counting in less than 3 minutes post irradiation. The samples were counted for various time intervals ranging from 5 minutes to 1 hour. The data was then analyzed to determine which radionuclides could be quantified and compared to the published fission yield data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Determining HPGe Total Detection Efficiency Using γ–γ Coincidence

Abstract Both the peak and total detection efficiencies are generally needed in order to calculate sample activity from a gamma spectroscopic measurement, except in the case of isotope specific calibration. This is particularly true when the sample is in close proximity to the detector and corrections for cascade summing effects are required to avoid significant inaccuracy in the result. These corrections use the total detection efficiency to correct for summing-in and summing-out events, and the extent of the correction depends on both the geometry and the gamma cascade for the isotope in question. Experimentally determining the total efficiency is a labor intensive endeavor requiring multiple measurements with a set of single-gamma-emitting standards. Modeling the total efficiency vs. energy may be less time consuming, but is also likely to produce less confidence in the final result. Pacific Northwest National Laboratory's Radiation Detection and Nuclear Sciences group has constructed a low background 14-crystal HPGe array for sample measurement; in all measurements, samples will be in close proximity to the germanium crystals. This close geometry and the sheer number efficiency calibrations required for the system have led us to investigate methods to simplify the efficiency calibration procedure. One method we are developing uses the Y-Y coincidence plane to isolate Compton scattering event populations, allowing experimental determination of total detection efficiency values from the measurement of a single mixed isotope standard. A description of the analysis and experimental results of this method are presented.

low background HPGe High Purity Germanium detector↗

Radioxenon detector calibration spike production and delivery systems

Abstract Beta-Gamma coincidence radioxenon detectors must be calibrated for each of the four-radioxenon isotopes (135Xe, 133Xe, 133mXe, and 131mXe). Without a proper calibration, there is potential for the misidentification of the amount of each isotope detected. It is important to accurately determine the amount of each radioxenon isotope, as the ratios can be used to distinguish between an anthropogenic source and a nuclear explosion. We have developed a xenon calibration system (XeCalS) that produces calibration spikes of known activity and pressure for field calibration of detectors. The activity concentrations of these calibration spikes are measured using a beta-gamma coincidence detector and a high purity germanium (HPGe) detector. We will present the results from the development and commissioning of XeCalS, along with the future plans for a portable spike implementation system.

beta-gamma coincidence detector↗

Parameters of Photo-Sensitive Structures Based on Ge/Si Nanogeterostructures

Infrared photodetectors with germanium quantum dots on silicon are considered. Some characteristics of such detectors are calculated, namely: dark current and detectivity in the modes of limitation by background and generation-recombination noises. A comparison is also made of the performance of quantum-dot infrared detectors with the performance of HgCdTe detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GeMini: A High-Resolution, Low-Resource, Gamma-Ray Spectrometer for Planetary Science Applications

GeMini is a high-resolution gamma-ray spectrometer designed for planetary-science exploration. GeMini serves as the basis for instruments being flown on three upcoming deep-space missions: NASA’s mission to the M-class asteroid (16) Psyche, the Japan Aerospace Exploration Agency sample-return mission to the moons of Mars, and NASA’s Dragonfly mission that will land on Saturn’s largest moon, Titan. These science missions require high-resolution spectroscopy in a low-power, low-mass, rugged design that can survive in a variety of environments. GeMini addresses these needs by providing a cryogenically cooled crystal of high-purity germanium that can operate with as little as 10 to 20 watts, depending on the implementation and mission, and has a mass of less than 2 kg. GeMini helps determine the elemental composition of planetary bodies by measuring gamma rays emitted from the surface. This paper describes the mechanical, thermal, and electrical design of GeMini as well as its performance. Further, it describes testing that was performed to validate the design with respect to launch loads and radiation damage. Although the basic design of GeMini is common to all three missions, each planetary body has unique environmental conditions and mission specifications. This paper concludes by describing these upcoming missions and how GeMini is customized for each.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic data and theoretical X-ray spectra of Ge-like through V-like W ions

The atomic structure and spectra of ten tungsten ions have been calculated using the Flexible Atomic Code. The calculations yield energy levels, radiative lifetimes, spectral line positions, transition probability rates, and oscillator strengths for the tungsten ions isoelectronic to germanium, W{sup 42+}, through vanadium, W{sup 51+}. Collisional–radiative models for high-temperature, low-density plasmas have been implemented to produce line emissivities for X-ray transitions in the 1–4 keV (3–12 Å) spectral interval. The Ge-like through V-like W ions are important in nuclear fusion research where their spectra may provide diagnostic information on magnetically confined plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Energy levels, lifetimes, and transition probabilities for Mn XII and Ge XIX

Energy levels, transition probabilities, oscillator strengths, line strengths, and lifetimes have been calculated for silicon-like manganese and germanium, Mn XII and Ge XIX. The configurations 3s{sup 2}3p{sup 2}, 3s3p{sup 3}, 3s{sup 2}3p3d, 3s3p{sup 2}3d, and 3p{sup 4} were used in the calculations and 88 fine-structure levels were obtained. The fully relativistic GRASP code has been adopted, and results are reported for all electric dipole, electric quadrupole, magnetic dipole, and magnetic quadrupole transitions among levels of Mn XII and Ge XIX. Comparisons have been made with available theoretical and experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 70 Ge( d , n ) 71 As cross section from 2.1 MeV to 10 MeV

This work reports experimental 70 Ge(d,n) 71 As cross sections producing Arsenic-71 (t 1/2 = 65.3 h, 28% β + ), a potentially useful diagnostic radionuclide. Target stacks containing two nat Ge foils, a nat Ni monitor foil, and an Al degrader were irradiated with 5.5–10 MeV deuterons using an FN Tandem Van de Graaff accelerator. 71 As and 61 Cu, 56 Co, and 58 Co (from nat Ni(d,x)) were quantified in the foils by high purity germanium gamma spectrometry. Furthermore, the measured cross sections are larger than previously reported and suitable for producing preclinical quantities of diagnostic radiopharmaceuticals.

07 ISOTOPE AND RADIATION SOURCES↗

127 Xe quantification method development and intercomparison exercise

Monitoring of the atmosphere for fission products ( 131m Xe, 133m Xe, 133 Xe, and 135 Xe) is performed by various laboratories to detect nuclear explosions. Quantification of 127 Xe is not routinely performed by laboratories measuring atmospheric radioxenon because it is not a fission product. 127 Xe was recently detected by a ground-based beta-gamma air monitoring system. When measured using beta-gamma coincidence detector systems, such as those in use on the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT), 127 Xe can interfere with the quantification of fission product radioxenon due to overlap of the 127 Xe beta-gamma coincidence signatures with those of fission product radioxenon. Here, this work demonstrates quantification of 127 Xe at different laboratories with different measurement techniques. Production and purification of 127 Xe was performed by neutron activation of enriched 126 Xe. The purified 127 Xe was then split between laboratories, and detection and quantification methods were developed. At Idaho National Laboratory, a quantification method involving high purity germanium detectors was devised that included self-attenuation correction. At AWE, a beta-gamma coincidence counting method, as used in support of the IMS, was modified to enable the measurement and analysis of the 127 Xe samples. Corrections were made for self-attenuation, which showed a strong xenon volume dependency, for some coincidence signatures. The gas sample activity concentration was used as the comparison metric and it showed excellent agreement between the methods.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Elemental Modes of Occurrence in an Illinois #6 Coal and Fractions Prepared by Physical Separation Techniques at a Coal Preparation Plant

In order to gain better insight into elemental partitioning between clean coal and tailings, modes of occurrence have been determined for a number of major and trace elements (S, K, Ca, V, Cr, Mn, Fe, Zn, As, Se, Pb) in an Illinois No.6 coal and fractions prepared by physical separation methods at a commercial coal preparation plant. Elemental modes of occurrence were largely determined directly by XAFS or Moessbauer spectroscopic methods because the concentrations of major minerals and wt.% ash were found to be highly correlated for this coal and derived fractions, rendering correlations between individual elements and minerals ambiguous for inferring elemental modes of occurrence. Of the major elements investigated, iron and potassium are shown to be entirely inorganic in occurrence. Most (90%) of the iron is present as pyrite, with minor fractions in the form of clays and sulfates. All potassium is present in illitic clays. Calcium in the original coal is 80-90% inorganic and is divided between calcite, gypsum, and illite, with the remainder of the calcium present as carboxyl-bound calcium. In the clean coal fraction, organically associated Ca exceeds 50% of the total calcium. This organically-associated form of Ca explains the poorer separation of Ca relative to both K and ash. Among the trace elements, V and Cr are predominantly inorganically associated with illite, but minor amounts (5-15% Cr, 20-30% V) of these elements are also organically associated. Estimates of the V and Cr contents of illite are 420 ppm and 630 ppm, respectively, whereas these elements average 20 and 8 ppm in the macerals. Arsenic in the coal is almost entirely associated with pyrite, with an average As content of about 150 ppm, but some As ({approx} 10%) is present as arsenate due to minor oxidation of the pyrite. The mode of occurrence of Zn, although entirely inorganic, is more complex than normally noted for Illinois basin coals; about 2/3 is present in sphalerite, with lesser amounts associated with illite and a third form yet to be conclusively identified. The non-sulfide zinc forms are removed predominantly by the first stage of separation (rotary breaker), whereas the sphalerite is removed by the second stage (heavy media). Germanium is the only trace element determined to have a predominantly organic association.

01 COAL, LIGNITE, AND PEAT↗

Structure and thermal conductivity of Na{sub 1-x}Ge{sub 3+z}

Structural analyses as well as low temperature thermal conductivity is reported for the binary phase Na{sub 1-x}Ge{sub 3+z}. Specimens were characterized by thermal analysis, conventional and synchrotron powder X-ray diffraction, neutron powder diffraction, {sup 23}Na nuclear magnetic resonance spectroscopy, and electrical and thermal transport measurements. With structural characteristics qualitatively analogous to some aluminum-silicate zeolites, the crystal structure of this phase exhibits an unconventional covalently bonded tunnel-like Ge framework, accommodating Na in channels of two different sizes. Observed to be non-stochiometric, Na{sub 1-x}Ge{sub 3+z} concurrently exhibits substantial structural disorder in the large channels and a low lattice thermal conductivity, of interest in the context of identifying novel low thermal conductivity intermetallics for thermoelectric applications. - Graphical abstract: A zeolite-like intermetallic, Na{sub 1-x}Ge{sub 3+z}, is prepared by thermal decomposition of Na{sub 4}Ge{sub 4}. This binary phase exhibits an unusual crystal structure in which germanium forms large tunnels with significant disorder, and is found to possess a very low lattice thermal conductivity.

36 MATERIALS SCIENCE↗