Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,225 records · Page 68

Al2O3 Atomic Layer Deposition on Nanostructured γ-Mg(BH4)2 for H2 Storage

In the context of the growing hydrogen (H 2 ) economy, the demand for H 2 storage materials is high, and metal borohydrides are of particular interest. Magnesium borohydride, Mg(BH 4 ) 2 , has one of the highest hydrogen capacities of all known metal hydrides (14.9 wt % H) but suffers from high operating temperatures, slow kinetics for (de)hydrogenation, and the loss of capacity upon cycling. Strategies to address these challenges include nanoencapsulation and the use of chemical additives. This work is the first to utilize these two strategies simultaneously by using atomic layer deposition (ALD). For this new approach to modify borohydrides, we chose the well-studied Al 2 O 3 ALD process using trimethylaluminum and water. Although there has been limited use of aluminum-based additives for Mg(BH 4 ) 2 , we demonstrate that the low-temperature H 2 capacity was doubled, desorption kinetics were increased by a factor of 3, and 100 cycles of Al 2 O 3 suppressed the release of diborane compared to the uncoated Mg(BH4)2. We identified that the use of trimethylaluminum and water in the ALD process affected the decomposition pathway and that the Al 2 O 3 film growth is dominated by infiltration due to the high porosity of the ..gamma..-phase Mg(BH 4 ) 2 . From these results, the potential of ALD as a method to functionalize solid-state H 2 storage materials is inferred, and recommendations for future ALD processes are presented.

08 HYDROGEN↗

Ligand efficacy shifts a nuclear receptor conformational ensemble between transcriptionally active and repressive states

Abstract Nuclear receptors (NRs) are thought to dynamically alternate between transcriptionally active and repressive conformations, which are stabilized upon ligand binding. Most NR ligand series exhibit limited bias, primarily consisting of transcriptionally active agonists or neutral antagonists, but not repressive inverse agonists—a limitation that restricts understanding of the functional NR conformational ensemble. Here, we report a NR ligand series for peroxisome proliferator-activated receptor gamma (PPARγ) that spans a pharmacological spectrum from repression (inverse agonism) to activation (agonism) where subtle structural modifications switch compound activity. While crystal structures provide snapshots of the fully repressive state, NMR spectroscopy and conformation-activity relationship analysis reveals that compounds within the series shift the PPARγ conformational ensemble between transcriptionally active and repressive conformations that are natively populated in the apo/ligand-free ensemble. Our findings reveal a molecular framework for minimal chemical modifications that enhance PPARγ inverse agonism and elucidate their influence on the dynamic PPARγ conformational ensemble.

Science & Technology - Other Topics↗

Parameterized Post-Newtonian Expansion of Scalar-Vector-Tensor Theory of Gravity

We investigate the weak-field, post-Newtonian expansion to the solution of the field equations in scalar-vector-tensor theory of gravity. In the calculation we restrict ourselves to the first post Newtonian. The parameterized post Newtonian (PPN) parameters are determined by expanding the modified field equations in the metric perturbation. Then, we compare the solution to the PPN formalism in first PN approximation proposed by Will and Nordtvedt and read of the coefficients (the PPN parameters) of post Newtonian potentials of the theory. We find that the values of {gamma}{sub PPN} and {beta}{sub PPN} are the same as in General Relativity but the coupling functions {beta}{sub 1}, {beta}{sub 2}, and {beta}{sub 3} are the effect of the preferred frame.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT Phantom{sup TM}), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the pinhole region-of-interest imaging. Conclusions: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy

Purpose: To test the feasibility of a dual detector concept for comprehensive verification of external beam radiotherapy. Specifically, the authors test the hypothesis that a portal imaging device coupled to a 2D dosimeter provides a system capable of simultaneous imaging and dose verification, and that the presence of each device does not significantly detract from the performance of the other. Methods: The dual detector configuration comprised of a standard radiotherapy electronic portal imaging device (EPID) positioned directly on top of an ionization-chamber array (ICA) with 2 cm solid water buildup material (between EPID and ICA) and 5 cm solid backscatter material. The dose response characteristics of the ICA and the imaging performance of the EPID in the dual detector configuration were compared to the performance in their respective reference clinical configurations. The reference clinical configurations were 6 cm solid water buildup material, an ICA, and 5 cm solid water backscatter material as the reference dosimetry configuration, and an EPID with no additional buildup or solid backscatter material as the reference imaging configuration. The dose response of the ICA was evaluated by measuring the detector’s response with respect to off-axis position, field size, and transit object thickness. Clinical dosimetry performance was evaluated by measuring a range of clinical intensity-modulated radiation therapy (IMRT) beams in transit and nontransit geometries. The imaging performance of the EPID was evaluated quantitatively by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of an anthropomorphic phantom were also used for qualitative assessment. Results: The measured off-axis and field size response with the ICA in both transit and nontransit geometries for both dual detector configuration and reference dosimetry configuration agreed to within 1%. Transit dose response as a function of object thickness agreed to within 0.5%. All IMRT test patterns and clinical IMRT beams had gamma pass rates of ≥98% at 2%/2 mm criteria. In terms of imaging performance, the measured CNR and spatial resolution (f{sub 50}) were 263.23 ± 24.85 and 0.4025 ± 1.25 × 10{sup −3} for dual detector configuration and 324 ± 26.65 and 0.4141 ± 1.14 × 10{sup −3} for reference imaging configuration, respectively. The CNR and spatial resolution were quantitatively worse in the dual detector configuration due to the additional backscatter. The difference in imaging performance was not visible in qualitative assessment of phantom images. Conclusions: Combining a commercially available ICA dosimetry device with a conventional EPID did not significantly detract from the performance of either device. Further improvements in imaging performance may be achieved with an optimized design. This study demonstrates the feasibility of a dual detector concept for simultaneous imaging and dosimetry in radiation therapy.

60 APPLIED LIFE SCIENCES↗

Identification of a diguanylate cyclase expressed in the presence of plants and its application for discovering candidate gene products involved in plant colonization by Pantoea sp. YR343

Microbial colonization of plant roots is a highly complex process that requires the coordination and regulation of many gene networks, yet the identities and functions of many of these gene products have yet to be discovered. Pantoea sp. YR343, a gamma-proteobacterium isolated from the rhizosphere of Populus deltoides , forms robust biofilms along the root surfaces of Populus and possesses plant growth-promoting characteristics. In this work, we identified three diguanylate cyclases in the plant-associated microbe Pantoea sp. YR343 that are expressed in the presence of plant roots. One of these diguanylate cyclases, DGC2884, localizes to discrete sites in the cells and its overexpression results in reduced motility and increased EPS production and biofilm formation. We performed a genetic screen by expressing this diguanylate cyclase from an inducible promoter in order to identify candidate gene products that may be involved in root colonization by Pantoea sp. YR343. Further, we demonstrate the importance of other domains in DGC2884 to its activity, which in combination with the genes identified by transposon mutagenesis, may yield insights into the mechanisms of plant association as well as the activity and regulation of homologous enzymes in medically and agriculturally relevant microbes.

59 BASIC BIOLOGICAL SCIENCES↗

Electromagnetic Radiation Effects on MgO-Based Magnetic Tunnel Junctions: A Review

Magnetic tunnel junctions (MTJs) have been widely utilized in sensitive sensors, magnetic memory, and logic gates due to their tunneling magnetoresistance. Moreover, these MTJ devices have promising potential for renewable energy generation and storage. Compared with Si-based devices, MTJs are more tolerant to electromagnetic radiation. In this review, we summarize the functionalities of MgO-based MTJ devices under different electromagnetic irradiation environments, with a focus on gamma-ray radiation. We explore the effects of these radiation exposures on the MgO tunnel barriers, magnetic layers, and interfaces to understand the origin of their tolerance. This review enhances our knowledge of the radiation tolerance of MgO-based MTJs, improves the design of these MgO-based MTJ devices with better tolerances, and provides information to minimize the risks of irradiation under various irradiation environments. This review starts with an introduction to MTJs and irradiation backgrounds, followed by the fundamental properties of MTJ materials, such as the MgO barrier and magnetic layers. Then, we review and discuss the MTJ materials and devices’ radiation tolerances under different irradiation environments, including high-energy cosmic radiation, gamma-ray radiation, and lower-energy electromagnetic radiation (X-ray, UV–vis, infrared, microwave, and radiofrequency electromagnetic radiation). In conclusion, we summarize the radiation effects based on the published literature, which might benefit material design and protection.

42 ENGINEERING↗

Solar cell radiation response near the interface of different atomic number materials

The response of cobalt 60 irradiated N/P silicon solar cells was measured as a function of the atomic number of the medium adjacent to the cell and the direction of the gamma ray beam. The interpositioning of various thicknesses of aluminum between the adjacent material and the cell had the effect of moving the cell to various locations in an approximate monatomic numbered medium. Using this technique the solar cell response was determined at various distances from the interface for gold and beryllium. The results were compared with predictions based upon ionization chamber measurements of dose perturbations in aluminum and found to agree within five percent. Ionization chamber data was then used to estimate the influence of various base contact materials.

Burke, E. A.↗

A quadratic pulse height analyzer for space applications.

A flight-worthy pulse height analyzer that has a quadratic transfer function is described. This quadratic function permits optimum usage of the entire PHA dynamic range due to the quadratic nature of the gamma ray spectrometer's resolution vs energy. After the theoretical design discussion, the implementation of the design is examined and test results described. The analyzer is part of the University of New Hampshire gamma ray monitor for OSO-H.

Burtis, D. W.↗

Measurement of the positron-electron reaction which produces a gamma ray pair in the region psi/3684/

An experiment was conducted to measure gamma ray pairs produced in the electron-positron reaction in the region of psi(3684) resonance. The apparatus consisted of two identical spectrometers mounted in a collinear configuration about the beam interaction region. Graphs are presented for the coplanarity angle between reconstructed gamma ray directions, for the scattering and energy deposition of gamma rays in the two crystals used, and for the observed rate of annihilation reactions as a function of center of mass energy.

Hughes, E. B.↗

Proposed three-phase modeling of Be stars from combined UV and visual observations

Far ultraviolet observations of the behavior of wind velocity and superionization values as a function of the phase of the (Be, B shell, B normal) pattern established by visual observations for gamma Cas and 59 Cyg are translated into a crude atmospheric model for the Be phase and several kinds of mass flux variability across the three phases.

Doazan, V.↗

Test results and in-orbit operation of the Infrared Astronomical Satellite circumvention circuit

The IRAS circumvention circuit (CC) eliminates the unwanted charged-particle pulses from the IR signal. The operation of the CC along with preflight and in-orbit testing is described. Ground testing of the brassboard circuit using a simulated preamplifier output showed that the CC would perform the circumvention function as designed. When all flight detectors and preamplifiers became available, the CC was tested using a gamma source to simulate charged-particle sources; with the low energy deposited in the detectors (20 keV average) the noise was reduced by up to 5 times with the CC turned on. In-orbit results show that the CC decreases the unwanted charged-particle background noise by up to two orders of magnitude. The difference in the results with the CC on and off is so great that the science team has recommended that no data be taken with the CC off.

Long, E. C.↗

CCSDS telemetry systems experience at the Goddard Space Flight Center

NASA Goddard Space Flight Center (GSFC) designs, builds, manages, and operates science and applications spacecraft in near-earth orbit, and provides data capture, data processing, and flight control services for these spacecraft. In addition, GSFC has the responsibility of providing space-ground and ground-ground communications for near-earth orbiting spacecraft, including those of the manned spaceflight programs. The goal of reducing both the developmental and operating costs of the end-to-end information system has led the GSFC to support and participate in the standardization activities of the Consultative Committee for Space Data Systems (CCSDS), including those for packet telemetry. The environment in which such systems function is described, and the GSFC experience with CCSDS packet telemetry in the context of the Gamma-Ray Observatory project is discussed.

Carper, Richard D.↗

Neutron energy determination with a high-purity germanium detector

Two areas that are related to planetary gamma-ray spectrometry are investigated. The first task was the investigation of gamma rays produced by high-energy charged particles and their secondaries in planetary surfaces by means of thick target bombardments. The second task was the investigation of the effects of high-energy neutrons on gamma-ray spectral features obtained with high-purity Ge-detectors. For both tasks, as a function of the funding level, the experimental work was predominantly tied to that of other researchers, whenever there was an opportunity to participate in bombardment experiments at large or small accelerators for charged particles.

Beck, Gene A.↗

SU-F-SPS-06: Implementation of a Back-Projection Algorithm for 2D in Vivo Dosimetry with An EPID System

Purpose: To implement a back-projection algorithm for 2D dose reconstructions for in vivo dosimetry in radiation therapy using an Electronic Portal Imaging Device (EPID) based on amorphous silicon. Methods: An EPID system was used to calculate dose-response function, pixel sensitivity map, exponential scatter kernels and beam hardenig correction for the back-projection algorithm. All measurements were done with a 6 MV beam. A 2D dose reconstruction for an irradiated water phantom (30×30×30 cm{sup 3}) was done to verify the algorithm implementation. Gamma index evaluation between the 2D reconstructed dose and the calculated with a treatment planning system (TPS) was done. Results: A linear fit was found for the dose-response function. The pixel sensitivity map has a radial symmetry and was calculated with a profile of the pixel sensitivity variation. The parameters for the scatter kernels were determined only for a 6 MV beam. The primary dose was estimated applying the scatter kernel within EPID and scatter kernel within the patient. The beam hardening coefficient is σBH= 3.788×10{sup −4} cm{sup 2} and the effective linear attenuation coefficient is µAC= 0.06084 cm{sup −1}. The 95% of points evaluated had γ values not longer than the unity, with gamma criteria of ΔD = 3% and Δd = 3 mm, and within the 50% isodose surface. Conclusion: The use of EPID systems proved to be a fast tool for in vivo dosimetry, but the implementation is more complex that the elaborated for pre-treatment dose verification, therefore, a simplest method must be investigated. The accuracy of this method should be improved modifying the algorithm in order to compare lower isodose curves.

60 APPLIED LIFE SCIENCES↗

Characterization of Surface and Bulk Nitrates of γ-Al2O3-Supported Alkaline Earth Oxides using Density Functional Theory

“Surface" and "bulk" nitrates formed on a series of alkaline earth oxides (AEOs), AE(NO3)2, were investigated using first-principles density functional theory calculations. The formation of these surface and bulk nitrates was modeled by the adsorption of NO2+NO3 pairs on gamma-Al2O3-supported monomeric AEOs (MgO, CaO, SrO, and BaO) and on the extended AEO(001) surfaces, respectively. The calculated vibrational frequencies of the surface and bulk nitrates based on our proposed models are in good agreement with experimental measurements of AEO/gamma-Al2O3 materials after prolonged NO2 exposure. This indicates that experimentally observed "surface" nitrates are most likely formed with isolated two dimensional (including monomeric) AEO clusters on the gamma-Al2O3 substrate, while the "bulk" nitrates are formed on exposed (including (001)) surfaces (and likely in the bulk as well) of large three dimensional AEO particles supported on the gamma-Al2O3 substrate. Also in line with the experiments, our calculations show that the low and high frequency components of the vibrations for both surface and bulk nitrates are systematically red shifted with the increasing basicity and cationic size of the AEOs. The adsorption strengths of NO2+NO3 pairs are nearly the same for the series of alumina-supported monomeric AEOs, while the adsorption strengths of NO2+NO3 pairs on the AEO surfaces increase in the order of MgO < CaO < SrO ~ BaO. Compared to the NO2+NO3 pair that only interacts with monomeric AEOs, the stability of NO2+NO3 pairs that interact with both the monomeric AEO and the gamma-Al2O3 substrate is enhanced by about 0.5 eV. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

36 MATERIALS SCIENCE↗

New routes for production of proton-rich Tc isotopes

Proton-rich Tc radionuclides have been identified as potential candidates for specific clinical and biological applications in the last decade. So far, these radionuclides have been produced either by proton-induced reaction on Mo targets or {alpha}-particle-induced reaction on Nb targets. This article lightens two heavy-ion-induced production routes of {sup 93,94,95,96}Tc radionuclides through {sup 7}Li+{sup nat}Zr and {sup 9}Be+{sup nat}Y reactions and provides important cross-sectional information in the projectile energy ranges 37-45 MeV and 30-48 MeV, respectively. Excitation functions of those reactions have been measured using the stacked-foil technique followed by the off-line {gamma}-spectrometric studies. Measured cross-sectional data have been interpreted comparing theoretical predictions of the two nuclear reaction model codes PACE-II and ALICE91. Experimental cross sections agreed with the theory. Measured production cross sections of {sup 94,95}Tc have been compared with those produced from the {alpha}+{sup 93}Nb reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-161: The Effect of Pencil Beam Scanning Gantry Angle Dependent Spot Size Variations On Plan Quality

Purpose: To investigate the effect of spot size variation as function of gantry angle on the quality of treatment plans for pencil beam scanning proton plans. Method: Three homogeneous 26×26×7cm dose volumes with different ranges and SOBPs were delivered on the matrixxPT 2D array at gantry angles of 0 and 270 degrees. The spot size sigma varies by 1.8, 7.8, and 1.4%, for nominal energies of 215, 183, and 103 MeV (Range 29, 22, and 8cm, respectively). The resulting dose planes are compared and evaluated with the gamma index for 2%/2mm and 1%/1mm criteria. Results: Patient specific QA is performed at a gantry angle of 0 degrees. However, beam sigmas vary as function of gantry angle because of the beam optics for each gantry. This will cause differences between the delivered and planned treatment plans. Delivered plans were compared and a gamma pass rate of 96.5% for criteria of 2%/2mm and 91.4% for 1%/1mm were seen for plans with a nominal energy of 183 MeV. For plans with a nominal energy of 103 MeV, gamma pass rates of 97.3% for 2%/2mm and 91.5% for 1%/1mm were seen. For plans with a nominal energy of 215 MeV the pass rate was 99.8% for 1%/1mm between the two gantry angles. Conclusion: Differences in beam sigma of up to 7.8% do not cause significant differences in the dose distribution of different spot size gammas.

60 APPLIED LIFE SCIENCES↗